PET Phantom - NEMA IEC/2001

Similar documents
NUCLEAR MEDICINE, PET PRODUCTS & CALIBRATORS

System Specifications

INSPECTION TECHNIQUE FOR BWR CORE SPRAY THERMAL SLEEVE WELD

@CapintecInc PET SHIELDING AND ACCESSORIES SPRING ARMED DOSE DRAWING STATION

PHILIPS Gemini GXL Site Planning Guide PETCT23

Created: 4/23/2003 Page: 1 of 12. Abstract

PET SHIELDING & ACCESSORIES LIST OF CONTENTS:

DEFECT DISTRIBUTION IN WELDS OF INCOLOY 908

ISO INTERNATIONAL STANDARD

511 Spring Armed Dose Drawing Station

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

Heating oven with mechanical control

Model ED 720 Drying and heating chambers Classic.Line with natural convection

Rugged steel cabinet construction ensures quiet operation and long term reliability.

Schematic design of the cryogenic baffles

ULTRASONIC TESTING OF RAILWAY AXLES WITH PHASED ARRAY TECHNIQUE EXPERIENCES DURING OPERATION

Model ED 400 Drying and heating chambers Classic.Line with natural convection

MOS Section Ken McCracken

ph fax Deming Way Middleton WI USA

Heating oven with natural convection

LTX RF LEVEL SENSOR. Instruction Manual

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

Metallic materials Rockwell hardness test. Part 2: Verification and calibration of testing machines and indenters

Optical Fusion Splicer

Model ED 400 Drying and heating chambers Classic.Line with natural convection

ISO 8754 INTERNATIONAL STANDARD. Petroleum products Determination of sulfur content Energy-dispersive X-ray fluorescence spectrometry

SPEC No.: ZP REVISION: 1.1 ZP ELECTRON CO.,INC. Designer. Division. Approver

DUST ALERT BinMaster Price Book binmaster.com Subject to change without notice 1

Electrostatics Revision 4.0b

Incubators. Incubators

ISO 5700 INTERNATIONAL STANDARD

Vertex Plus, Vertex V60, Solus & Cardio Camera Site Planning Document

AVL Particle Measurement System Aviation

1' to 10' deep and 1' to 25' deep

Heating chamber with mechanical convection

Accu-Cut CT. Automated Tubing Cutter with Caterpillar Drive

Heating chamber with mechanical convection

N-03 STEERING GEAR CONTROL SYSTEMS

ISO INTERNATIONAL STANDARD. Mechanical vibration Rotor balancing Part 21: Description and evaluation of balancing machines

Permanent Multipath Clamp-On Transit Time Flow Meter

ISO-9001:2008 CENTRIFUGES CATALOG. Phone: Fax: Web: expotechusa.com

Climate chamber with illumination

MKT 240 (E3) - Environmental simulation chamber for complex temperature profiles in the low temperature range

Elemental Analysis Advanced

ISO INTERNATIONAL STANDARD. Wheelchair seating Part 4: Seating systems for use in motor vehicles

Heating chamber with mechanical convection

Heating chamber with mechanical convection

Reli-a-Flex TM Reliance

Refrigerated incubator with Peltier technology

Climate chambers with illumination

Quindos the Ultimate Software package for Gears, Gear Tools and other Special Applications

1998 Addendum to the 1995 STANDARD FOR PROTECTIVE HEADGEAR. For Use With Bicycles. and to the 1994 STANDARD FOR PROTECTIVE HEADGEAR

Heating oven with mechanical convection

DMT PERFORMING UNDER PRESSURE DMT. Pressure Scanner Features. Applications. Description 1/7

Slim-Line Pipette Tips

WNTE: A regulatory tool for the EU? GRPE Meeting of the Off-Cycle Emissions Working Group. Geneva, June 2006

ISO INTERNATIONAL STANDARD. Road vehicles Test methods for electrical disturbances from electrostatic discharge

8 Breast Biopsy. 8.1 SENSE Breast 7 coil. Breast biopsy can be performed using the SENSE Breast 7 coil.

RoaDyn S635 System 2000

Ultra Series: Crossed Roller Ultra Precision Stages

NOTE: THESE PROCEDURES ARE THE SAME AS BEING IN THE SERVICE MODE. NOTE: ONCE THE UNIT IS POWERED DOWN THE VALUES FOR C4 WILL BE GONE.

STANDARD PNEUMATIC RAM TEST METHOD AND EQUIPMENT USED IN EVALUATING THE PERFORMANCE CHARACTERISTICS OF PROTECTIVE HEADGEAR AND FACE GUARDS

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

Water Treatment Pressure Vessel

M-11 MARINE DIESEL ENGINE FUEL INJECTOR

Penetration. Test Methods

Impulse Voltage Test System, Q Structure, kV

Drying ovens. ED 53 - Drying oven with natural convection. Performance features and equipment :

TBI /2012 TRAUMATIC BRAIN INJURY DEVICE

EXAMINATION OF NOZZLE INNER RADIUS AND PIPING FROM THE OUTER SURFACE

Thermocouples. General Applications Tube and Wire. Thermal Devices, Inc. Mount Airy, Maryland USA

Automated Driving: Design and Verify Perception Systems

Thermocouples. General Applications Tube and Wire. Performance Capabilities. Features and Benefits. Typical Applications. Construction and Tolerances

Part 1: Basic requirements

Design of a mount for a new generation X-ray detector board Final Report

Screw Driven automation tables

GOCI Yonsei aerosol retrievals during 2012 DRAGON-NE Asia and 2015 MAPS-Seoul campaigns

Extreme Environment For high pressure, low temperature, and high temperature applications

SFI SPECIFICATION 28.3 EFFECTIVE: APRIL 21, 2014 *

INTERNATIONAL STANDARD

POWER RAMPING AND CYCLING TESTING OF VVER FUEL RODS IN THE MIR REACTOR

ISO INTERNATIONAL STANDARD

Modeling Lithium-ion Batteries and Packs for Crash Safety. MIT Impact and Crashworthiness Lab

Programming of different charge methods with the BaSyTec Battery Test System

EE75. High-Precision Air / Gas Velocity Transmitter for Industrial Applications. Model A. Model B. Model C. Typical Applications.

Large Capacity, High-Speed Centrifuge

Dual Axis Magnetic Field (Axial and Radial) Sensor

Transmitted by the expert from the European Commission (EC) Informal Document No. GRRF (62nd GRRF, September 2007, agenda item 3(i))

~tl- $ --1Lrr-=- Couplings. Coupling BSW Coupling BSW Shaft Coupling with Smooth Adjustment BSW

FEATURES AND BENEFITS

Experimental Investigation of Hot Surface Ignition of Hydrocarbon-Air Mixtures

«CHARPY» Computerized Pendulum IMPACT TESTERS

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

Electromagnetic Flow Monitor magphant

Spatial and Temporal Analysis of Real-World Empirical Fuel Use and Emissions

Kaydon white paper. The importance of properly mounting thin section bearings. an SKF Group brand. by Rob Roos, Senior Product Engineer

DESCRIPTION OF THE DELPHI SUBCRITICAL ASSEMBLY AT DELFT UNIVERSITY OF TECHNOLOGY

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

Report, Test of HIFROST Longitudinal Holding Coil (7/19/6)

Module design and development for LHCb VELO Upgrade Project

Transcription:

PET Phantom - NEMA IEC/2001 2000 NEMA Standards, ideal for whole-body PET. Simulation of whole-body imaging using PET and camera-based coincidence imaging techniques Evaluation of reconstructed image quality in whole-body PET and camera-based coincidence imaging Determination of the coincidence count rate characteristics in brain and cardiac imaging Evaluation of the relationship between true coincidence count rate and radioactivity Determination of the address errors caused by address pile up Evaluation of the count loss correction scheme Performance Measurements of Positron Emission Tomographs, NEMA Standards Publication No. NU2, National Electrical Manufacturers Association (NEMA), Washington, DC, 2001 International Standard: Radionuclide imaging devices- Characteristics and test conditions - Part I: Positron Emission Tomographs, International Electrotechnical Commission (IEC), 61676-1, Geneva, Switzerland, 1998. Dimensions: 9.5" h x 12" w x 9.5 depth (24.1 x 30.5 x 24.1 cm) Interior Length of Phantom: 180 mm Fillable Spheres (six) Inner Diameter: 10 mm, 13 mm, 17 mm, 22 mm, 28 mm and 37 mm Distance From Sphere Plane to Inside Wall: 70 mm Volume of Empty D Shaped Cylinder: 9.7 L Cylindrical Insert Dimension: O.D.: 51 mm dia x 180 mm length Shipping Weight: 11 lb (4.9 kg) PET Scatter Phantom - NEMA Acceptance testing Determine the imaging systems relative sensitivity to scatter radiation Measure the effects of dead-time and the effects of random events generated at different levels of activity of the line source Performance Measurements of Positron Emission Tomographs, NEMA Standards Publication No. NU2, National Electrical Manufacturers Association (NEMA), Washington, DC - 2001

Cylinder Outside Dimension: 20.3 cm dia x 70 cm long Cylinder Hole Size: 6.4 mm Cylinder Hole Offset: 4.5 cm Line Source Dimensions: 5 mm O.D. x 80 cm long Line Source Inside Diameter: 3.2 mm Shipping Weight: 52 lb (23.5 kg) PET Sensitivity Phantom - NEMA Ideal for PET camera sensitivity Performance Measurements of Positron Emission Tomographs, NEMA Standards Publications No. NU2, National Electrical Manufacturers Association (NEMA), Washington, DC, 2001 Five internally stacked concentric aluminum tubes all 700 mm in length 1st Tube - Inside Diameter: 3.9 mm - Outside Diameter: 6.4 mm 2nd Tube - Inside Diameter: 7.0 mm - Outside Diameter: 9.5 mm 3rd Tube - Inside Diameter: 10.2 mm - Outside Diameter: 12.7 mm 4th Tube - Inside Diameter: 13.4 mm - Outside Diameter: 15.9 mm 5th Tube - Inside Diameter: 16.6 mm - Outside Diameter: 19.1 mm 6th Innermost Tube (a fillable polyethylene tube) - Inside Diameter: 1 mm - Outside Diameter: 3 mm Shipping Weight: 3 lb (1.3 kg)

NEW PET-CT Phantom The PET-CT Phantom includes internal structures (three rods and six spheres) which, when imaged with both modalities, can demonstrate how accurately the two image sets are aligned. In addition, a single sample of radioactive water is attenuated by water, bone and CT contrast material (as well as air only) to determine how accurately the CT-based PET attenuation correction works. The Phantom is used for: Acceptance testing of PET/CT and SPECT/CT systems Routine quality evaluation of PET/CT and SPECT/CT systems Evaluation of new image fusion software Evaluation of new attenuation correction algorithms Aluminum tubes are for registration The outer 2" OD micro cylinder is for comparing attenuation region to non attenuation region The 6" ring is for contrast solution Research Main Cylinder: Interior length of phantom: 180 mm Fillable spheres (5) inner diameter: 10 mm, 13 mm, 17 mm, 22 mm, and 28 mm. Distance from sphere plane to inside wall: 70 mm Volume of empty cylinder: 9.7 liters Main Cylindrical insert dimension: Outside diameter: 51 mm Length: 180 mm Top Cylinder: Cylinder outside diameter: ~5.1 cm Cylinder inside diameter: ~4. cm Cylinder inside height: ~8.2 cm Cylinder outside height: ~12.0 cm Volume of empty cylinder: 408 cm2 Three Aluminum Tubes: One 5 inch long: ~1.7 cc Two 7 inch (ea): ~ 2.5 cc Stepped Bone Ring: Pre-filled with liquid bone composition, not to be opened The volumes for the bone ring are: Outer volume: 15.6 cu inch: ~256 cc Inner volume: 6.7 cu inch: ~110 cc Jaszczak SPECT Phantoms ECT phantoms for PET and SPECT, meets ACR requirements The flangeless SPECT Phantom and the flangeless PET Phantom meet the requirements set by ACR. The appropriate phantoms provide consistent performance information for any SPECT or PET system. The SPECT Phantom is the same as the Deluxe SPECT Phantom except that the flanges have been removed. Multiple performance characteristics of camera-based SPECT systems are evaluated from a single scan of the phantom. On-axis and off-axis transverse line spread function may be easily measured without removing the cover plate. Measurements of full-width-half (or tenth)

maximum can be readily determined, either in air or in water. The Phantom is used for: System performance valuation of: Collimator, Artifacts, Calibration, and Reconstruction Parameters Acceptance testing Routine quality, assurance and control Evaluation of center-of-rotation error Evaluation of non-uniformity artifact Evaluation of changes of radius-of-rotation on spatial resolution Evaluation of reconstruction filters on spatial resolution Evaluation of attenuation and scatter compensation Single slice volume sensitivity Total system volume sensitivity Lesion detectability The Flangeless SPECT Phantom is used for high resolution cameras, complying to the ACR requirements. Flangeless PET Phantom Lid Image of PET Phantom Lid PET Phantom Lid Containers SPECT and PET Phantoms: Cylinder Interior Dimensions: 8" dia x 7.32" h (20.4 x 18.6 cm) Cylinder Wall Thickness: 0.25" (6.4 mm) Volume: 6.4 L Volume With Inserts: 5.7 L Cold Rod Insert Height: 3.46" h (8.8 cm) Cold Rod Dimensions: 4.8 mm, 6.4 mm, 7.9 mm, 9.5 mm, 11.1 mm, 12.7 mm Height of Spheres From Base Plate: 5" h (12.7 cm) Solid Sphere Diameters: 9.5mm, 12.7 mm, 15.9 mm, 19.1 mm, 25.4 mm, 31.8 mm Flangeless Esser PET Phantom Lid Refillable thin-walled cylinders: 8,12,16,25 (x3)mm Solid cylinder (Teflon ): 25mm Cylinder height: 1.5 in