Bussmann series Quik-Spec Power Module Switch elevator disconnect

Similar documents
BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

Effective December 2015 Supersedes September 2013

UL Recognized power distribution blocks

BH-1 modular fuse blocks, 700 V, 400 A

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Bussmann series Quik-Spec Coordination Panelboard

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Electric vehicle auxiliary fuses 500 Vdc, A

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Quik-Spec Electrical Gear

Compact Circuit Protector

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

6.3 mm reverse quick connect

BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Low-Peak 600V Class RK1

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

up to 30A limited by conductor size Operating and storage temperature:

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Class J modular ferrule and knifeblade fuse blocks

Quik-Spec. Section Contents

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Specification made simple for selective coordination in a compact size

PT Medium voltage fuses for potential and small power transformers

Compact Circuit Protector (CCP)

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Quik-Spec Coordination Panelboard A fusible panelboards

CUBEFuse. CUBEFuse catalog numbers (amps)

Quik-Spec Coordination Panelboard A fusible panelboards

Quik-Spec Coordination Panelboard Specifications

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

N0N A 250V One-Time Class H Fuse

Compact Circuit Protector (CCP)

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Selection and application guide

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

The easiest and fastest way to select and specify the right fuse

Assembly not available for new installations.

The easiest and fastest way to select and specify the right control circuit fuse

Now - Up To 400A Mains!

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Compact Circuit Protector

Industry s most comprehensive medium voltage circuit protection

footprint of traditional fusible switches

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Enclosures. See Section Typical Description

3. Coils shall be of molded construction

5 x 20mm Fuses S500 Series, Fast-Acting, Glass Tube

Operation and Maintenance manual. fusible shunt trip switch

Medium Voltage Metal-Enclosed Switches

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

A. Products shall be designed, manufactured, tested, and installed in compliance with the following standards:

C E R T I F I C A T E O F C O M P L I A N C E

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Engine Generator Circuit Breakers

PRE-ENGINEERED SOLUTIONS. LCP Series Fused Coordination Panel LPS Series Shunt Trip Disconnect Switch

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

NEMA Contactors & Starters (Freedom)

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Industrial Control Transformers

Definite Purpose Contactors and Starters

OTEC Transfer switch open transition

R-Rated medium voltage fuses for motor circuit protection

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

XMC0 Series DEFINITE PURPOSE CONTACTORS

Parts Manual. Transfer Switch. OTPCB (Spec A) 150/225/260 Amps. English Original Instructions (Issue 4)

Parts Manual. Transfer Switch. OTPCC (Spec A) 300/400/600 Amps. English Original Instructions (Issue 4)

IN2 Enclosed Switches and Circuit Breakers

Single-phase step voltage regulators

Class gg/gl, 690Vac, 2 to 500 Amps, Sizes 000 to 3 NH Series

Definite Purpose Contactors and Starters

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

ches UL File No. E101598

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Technical data OT16E3 OT160E3 UL & CSA

SECTION MOTOR CONTROL

1.2. Reduced Voltage Motor Starters. Contents Description Type S611, Solid-State Soft Starters... Type S801+, Soft Starters. Solid-State Starters

Instructions for A200, A210, A250 size 6, two- or three-pole non-reversing or reversing motor controllers

overvoltage solutions

SPEEDFAX TM 2011 Disconnect Switches Contents

SECTION PANELBOARDS

Certi 堵脝 cation Record

Multi-Pak Group Control

Transfer switch OTEC open or delayed transition

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Transcription:

Supersedes January 2016 Agency information UL 98 enclosed and dead-front switch - Guide WIAX, WIAX7 (Canada), File E182262 culus, NEMA 1, UL 50, Listed enclosure cul per Canadian Standards C22.2, No. 0-M91-CAN/ CSA C22.2, No. 4-M89 enclosed switch U.B.C. and C.B.C. seismic qualified, and I.B.C. approved Catalog symbol: PS_ Description: Eaton Bussmann series Quik-Spec Power Module Switch is an all-in-one switch available in configurations to meet virtually any single elevator shutdown and disconnect requirement. Specifications: Ratings Volts - 208, 240, 480, 600Vac Amps - 30, 60, 100, 200, 400 SCCR - 200kA RMS Features: 30-400 amp 600Vac 3-phase fused power switch 200kA RMS Short-Circuit Current Rating (SCCR) Shunt trip 120V Fire safety interface relay Fire alarm voltage monitoring relay (to monitor shunt trip voltage) Ground lug Class J fuse mounting only 1 Mechanically interlocked auxiliary contacts for hydraulic elevators with battery backup (5 amp 120Vac rated) Options: Control power transformer with fuses and blocks Key to test switch Pilot light ON Isolated neutral lug 2 NEMA 3R, 4, and 12 enclosures For added protection, use the Bussmann series SAMI fuse covers 3 to improve electrical safety [OSHA 1910.335(A)(2)(ii)]. See data sheet no. 1204. 1 Class J fuses not included. 2 Oversized 200% rated neutral option available where required by excessive non-linear loads. 3 Covers available up to 100A.

Catalog number system: PS 1 T48 R1 K G N1 B F1 U Prefix PS = Power Module Switch Control transformer* T20 = 208V T24 = 240V T48 = 480V T60 = 600V Key test switch (optional) Neutral lug (optional) K = Key N6 = 30-60A N1 = 100A N2 = 200A N4 = 400A Fire alarm voltage monitoring relay To monitor shunt trip voltage F1 = 1-Pole Relay F3 = 3-Pole Relay** Amp rating 3 = 30A 6 = 60A 1 = 100A 2 = 200A 4 = 400A Fire safety interface relay (3PDT, 10A, 12V) R1 = 120Vac Coil R2 = 24Vdc Coil Pilot light ON (optional) G = Green R = Red W = White Auxiliary contacts B = 2 NO/NC Enclosure = Type 1 U = Type 3R Z = Type 12 Y = Type 4 * 100VA with primary and secondary fusing (120V secondary). ** For use only with R1 option. Type 1 standard, no suffix designator required. Conductor data: Lineside molded case switch connection (Al-Cu) Loadside fuse block connection (Al-Cu) Torque Screw Torque Screw Cat. no. prefix Amps Conductor range Wire size lb-in (N m) head/ style Conductor range Wire size lb-in (N m) head/ style #8 40 (4.5) #8 40 (4.5) PS3 30 #14-1/0 Slot HD #14-2 Slot HD #6-4 45 (5.1) #6-2 45 (5.1) #3-1/0 50 (5.6) #8 40 (4.5) #8 40 (4.5) PS6 60 #14-1/0 Slot HD #14-2 Slot HD #6-4 45 (5.1) #6-2 45 (5.1) #3-1/0 50 (5.6) PS1 100 #14-1/0 #14-1/0 50 (5.6) Slot HD #14-1/0 #14-1/0 50 (5.6) Slot HD PS2 200 #4-4/0 #4-4/0 120 (13.5) 3/16 hex socket #4-300kcmil #4-300kcmil 275 (31.1) 5/16 hex socket PS4 1 400 (2) #2-500kcmil (2) #2-500kcmil 375 (42.4) 5/16 hex socket (2) 1/0-300kcmil or (1) 750kcmil (2) 1/0-300kcmil or (1) 750kcmil 500 (56.5) 3/8 hex socket 2

Technical Data 1145 Conductor data: Neutral mains connection (Al-Cu) Torque Cat. no. prefix Amps Conductor range Wire size lb-in (N m) Screw head/style PS3 30 #14-2 #8 40 (4.5) Slot HD #6-2 45 (5.1) PS6 60 #14-2 #8 40 (4.5) Slot HD #6-2 45 (5.1) PS1 100 #14-1/0 #14-1/0 50 (5.6) Slot HD PS2 200 #6-250kcmil #6-250kcmil 275 (31.1) 5/16 hex socket PS4 400 (2) 1/0-300kcmil or (1) 750kcmil (2) 1/0-300kcmil or (1) 750kcmil 500 (56.5) 3/8 hex socket Terminal block data: Torque Screw Catalog no. Wire range (Cu) lb-in (N m) head/style All #22-#10 5.3-7 (0.6-0.8) Slot Switch maximum horsepower ratings: Ratings are based on three-phase, motor type and time-delay fuses. Voltage (Vac) Switch amp rating 30A (PS3) 60A (PS6) 100A (PS1) 200A (PS2) 400A (PS4) 208 5 10 15 40 75 240 5 10 20 40 75 480 10 25 40 75 150 600 15 30 50 100 200 The above table can be used for estimating switch amp ratings for motor loads based upon the motor horsepower. For general applications, excluding wound rotor and DC motors, NEC 430.52 allows sizing at 175% of motor Full Load Amps (FLA) or the next standard size per NEC 240.6. If sizing at 175% will not allow the motor to start, NEC 430.52 will allow the fuses to be sized up to 225% of motor full load amps or the next size down. NOTE: In sizing the fuses, the motor FLA is per NEC table 430.250, not per motor nameplate information. Inrush currents of motors may vary, consult motor manufacturer data for correct sizing. On elevator applications, motor load plus auxiliary loads need to be considered. Follow elevator manufacturer s recommendation for correct fuse sizing. Standard shunt trip ratings: For 30-100A, 200A and 400A Power Module Switches. Momentary Voltage Max inrush Max ontime* inrush 120Vac, 60Hz 4 amps 1.5 cycles 140VA * Will handle up to 447VA inrush. 3

Dimensions in (mm): Catalog no. prefix Amps H W D1 D2 A B PS3 30 PS6 60 29.6 (752) 17.3 (439) 6.9 (165) 11.2 (284) 28.4 (721) 10 (254) PS1 100 PS2 200 32.6 (828) 21.3 (541) 7.0 (178) 11.3 (287) 31.1 (790) 17 (432) PS4* 400 54.6 (1387) 26.5 (673) 7.5 (190) 12.7 (323) 53.3 (1354) 22 (559) * PS4 dimensions shown are for NEMA 1 enclosure only. Contact factory for availability of other enclosure ratings. D2 B H A D1 W Power Module Switch shipping weights* Switch catalog number family Weight lbs. (kgs) PS1 58 (26.3) PS2 76 (34.5) PS3 58 (26.3) PS4 198 (89.8) PS6 58 (26.3) * Weights for each catalog number family are average. 4

Technical Data 1145 Power Module Switch wiring: 5

Power Module Switch wiring continued: 6

Technical Data 1145 Power Module Switch wiring continued: 7

The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 44122 Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 63021 United States 2016 Eaton All Rights Reserved Printed in USA Publication No. 1145 BU-SB14455 July 2016 Eaton, Bussmann, Quik-Spec and SAMI are valuable trademarks of Eaton in the US and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. NEC is a registered trademark of the National Fire Protection Association, Inc. NEMA is a registered trademark of the National Electrical Manufacturers Association. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton s Bussmann series product information, call 1-855-287-7626 or visit: Follow us on social media to get the latest product and support information.