EBF-550. Battery Powered Hand Washing Faucet

Similar documents
Electronic Hand Washing Faucet

Sloan Automatic Infrared Sensing Faucets

BASYS Infrared Sensor Activated

EBF-750 Deck-Mounted Battery Powered Sensor Operated Gooseneck Faucets

Optima ETF-600/ETF-610

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

ETF-600 Sensor Operated Lavatory Faucet

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

Battery Powered Sensor Operated Lavatory Faucets. Plug-in Transformer Powered Sensor Operated Lavatory Faucets PARTS LIST

SWITCH-RATED = + Plugs & Receptacles THE MAIN DIFFERENCES. DECONTACTOR TM Technology. Switch and Hp Ratings. Short Circuit Ratings

8110/8111. Model O P T I M A S Y S T E M S. Battery Powered Flushometers

PHASE MONITOR RELAYS Product Summary

INSTALLATION INSTRUCTIONS FOR SLOAN SF ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

Electronic Faucet - 591T Series

Plugs, Receptacles & Connectors

FOR USE WITH SLOAN S ORIGINAL OPTIMA PLUS FLUSHOMETER PRODUCED FROM AND REGAL PRO OPTIMA PLUS PRODUCED AFTER MAY, 2003

BASYS Infrared Sensor Activated

QS Motor Group Controller QSE-CI-4M-D 4-Output AC Motor Controller. Energi Savr NodeTM Unit. seetouchr QS Wallstation. Wireless Communication

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

TAG: Electronic Faucets EC Electronic Sensor Faucet. Architect/Engineering Specifications:

OPERATION & MAINTENANCE MANUAL 6700C Series Faucet

Operating Manual for Hands-Free Wall Mounted Scrub Sinks AC Models 504A and 504A-0.5 Battery Models 504B and 504B-0.5

Operating Manual for Three-Person Hands-Free Floor Mounted Wash Stations AC Models 56FAL and 56FAL-0.5 Battery Models 56FBL and 56FBL-0.

S-9100, S-9200, S-9300, S-9400, S-9700, S-9800

MT218

Energy Saving LED Lights Adding task and accent lighting to your kitchen design just got easier -

ERV SL, BR, GR & EV SERIES SINGLE/MULTI-FAMILY ERV CATALOG JANUARY 2019 RENEWAIRE.COM

Automatic Sensor Tap Installation Manual

Taking small steps together, always ahead, towards a better world. Filtrasept. HEPA filter housings for ceilings and walls

KOP3 Battery Charger. User's Manual

ACTIVE VOLTAGE STABILIZER

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED LAVATORY FAUCETS

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR-ACTIVATED LAVATORY FAUCETS

Columbia does not recommend use with harsh chemicals. NSF/ANSI Standard 2 - Food Equipment and NSF/ANSI 372 low-lead.

Wafer Style Silent Check Valves are designed to close

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Operating Manual for Hands-Free Floor Mounted Scrub Sink Models 532FA and 532FB

OPERATION & MAINTENANCE MANUAL 5000E Series Faucet

T&S BRASS AND BRONZE WORKS, INC.

Maintenance Guide. OPTIMA Components:

G lobe Style Check Valves are designed to close before the

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

HYDROTEK INTERNATIONAL, INC Forsyth Commerce Rd., Ste. 124, Orlando, FL Phone (800) / Fax (866)

Effective Date: May Rev. 1/9/2018- Void After: May Product: Lead Free Plumbing Products File No. 6905

MODULAR INTELLIGENT ACTIVE FILTERS

CRUSHING & SCREENING SOLUTIONS

Taking small steps together, always ahead, towards a better world. Optima CG / Optivent CG. Innovative Laminar Flow Solutions for Operating Theatres

Operating Instructions

Single Handle Faucet, 4 Plate, Ceramic Cartridge, Extended Lever Handle with Pop-Up

INSTALLATION INSTRUCTIONS FOR ELECTRONIC SENSOR ACTIVATED LAVATORY FAUCETS

G lobe Style Check Valves are designed to close before the

Pall Allegro 3D Biocontainers and Totes

INSTALLATION INSTRUCTIONS FOR ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

J-1160 J-1175 J JAW CRUSHERs

FIELD ADJUSTABLE REG-U-MATIC PRESSURE REGULATING VALVES

SPECIFICATION: OPERATION: (Dimensional drawing on following page)

Taking small steps together, always ahead, towards a better world. ScandDust. Dust collectors

INSTALLATION INSTRUCTIONS SINGLE, DOUBLE, TRIPLE AND QUADRUPLE STATION SENSOR OPERATED SOLID SURFACE AND BIO-DECK LAVATORY SYSTEMS ELC-41000

SPEAKMAN. SEF-1800-CA, SEF-1800-CA-TW, SEF-1800-CA-8, SEF-1800-CA-8-TW Installation, Maintenance & Operation Instructions EYESAVER FAUCET

LAR POWERED BIKE RACK SYSTEM. Daniel Adarme (E.E) The Pham (E.E) Christine Erwin (E.E) Nha Nguyen (E.E)

GKC1825L

Counter-Mount Touch-Free and Manual

Z x 17 Countertop Lavatory

Recoat / Proof Test. Fiber Recoaters and Proof Testers. Recoat. Capabilities

REQUEST FOR QUOTATION CITY OF PORT HURON 100 McMorran Boulevard Room 217 Port Huron Michigan Phone: (810) Fax: (810)

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED FLUSHOMETER WITH WALL BOX CONCEALED CLOSET & URINAL INSTALLATIONS

5,40,80. Vacuum Filter. AFJ Series. The bowl is covered with a transparent bowl guard! Max. washing them.

Series AL. Modular Type Lubricator AL10 AL20 AL30 AL40 AL40-06 AL50 AL60. Pages 50 through 54. Lubricator. Port size. Model. M5 x 0.

LIGATURE RESISTANT SENSOR FAUCET

SIRIUS 3RW5 Soft Starters

G2 Optima Plus Flushometer

B W S 4 FRIENDS KITCHEN ID9.1 DENVER, COLORADO N Roslyn Street D E S I G N G R O U P PROPOSED INTERIOR ELEVATIONS DINING ROOM WEST SCALE:

ADDENDA #1. Renovation and Construction of Boy s and Girl s Restroom Mountain View Alternative High School

INSTALLATION INSTRUCTIONS FOR EAF-350 SERIES ELECTRONIC, BATTERY-POWERED, SENSOR-ACTIVATED LAVATORY FAUCETS

T&S BRASS AND BRONZE WORKS, INC.

INSTALLATION INSTRUCTIONS FOR SLIMLINE BEDPAN WASHER WITH EXPOSED ROYAL FLUSHOMETER

MANUFACTURER AND DISTRIBUTOR OF QUALITY OILFIELD EQUIPMENT

Table of Contents. Description. Page. Introduction

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED URINAL INSTALLATIONS

J-1175 Dual Power Jaw Crusher

12.5 Mirror, Steering Column Adjustment, Heated Mirrors (MSC) Contents

Optima Flushometers Current style Royal (after 09/26/10)

SELECTION GUIDE. A broad selection of inlet and outlet configurations and choice of sizes. Easily Selectable Easily Serviceable

Model Z Sundara Reef Double Basin Hand Washing System

FIRE HOSE. NOTE: All Hose Normally Supplied With Couplings Attached.

Electronic Throttle Body

INSTALLATION AND MAINTENANCE GUIDE ELITE SERIES ELECTRONIC LAVATORY FAUCET

TBD 616. The Genset Engine.

INSTALLATION INSTRUCTIONS OPTIMA SYSTEMS SENSOR OPERATED ROYAL FLUSHOMETER CONCEALED & EXPOSED CLOSET INSTALLATIONS

Column Loudspeakers. Communications Systems Column Loudspeakers. Good speech intelligibility and background music reproduction

SELECTION GUIDE. A broad selection of inlet and outlet configurations and choice of sizes. Easily Selectable Easily Serviceable

Model Z TAS TAG

Builders Faucets. c. Roman Tub Faucets i. Trim ii. Rough In iii. Roman Tub Filler Valves Only

AquaSpec Commercial Products

A Product Line from Acorn Engineering Company PRODUCTS. Acorn Controls for bather safety and comfort SHOWERING & TEMPERING

Sloan & Zurn Flush Valves

INSTALLATION AND MAINTENANCE GUIDE SF1596 B/E ELECTRONIC LAVATORY FAUCET

WORK POSITIONERS. u WIDE RANGE OF ACCESSORIES AND TOOLS u FASTEST LIFTING SPEED ON THE MARKET u SILENT AND EASY TO OPERATE

TempControl Thermostatic Water Controllers

INSTALLATION INSTRUCTIONS FOR BATTERY POWERED SENSOR ACTIVATED HAND WASHING FAUCETS

Transcription:

Battery Powered Hand Washing Facet EBF-550 Back Monted, Battery Powered, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head Specifications ADA Compliant, Battery Powered, Sensor Activated, Chrome Plated Brass Gooseneck Hand Washing Facet with the following featres: Splash-proof Circit Control Modle Isolated Latching Solenoid Operator, isolates magnetic components from water contact Sensor Range Adjstment Screw Low Battery LED Indicator Light User friendly Variable Time Ot Settings Serviceable Filtered Solenoid Valve Bak-Chek Tee for Hot/Cold Spply Spray Head with Pressre Compensating Flow Control Metal Jacketed Wire Protection for Sensor Lead Incldes for (4) AA-size Alkaline Batteries Appropriate Monting Hardware inclded Optional 6 VDC Plg-in Adapter available (Batteries act as backp when sing optional adaptor) Variations (Add sffix to Model Nmber for inclsion with Facet) Spot and Spray Head Variations H Shower Spray Head (2.2 gpm/8.3 Lpm) S Srgical Bend Spot Temperatre Mixing Valves (optional) BDM Below Deck Mechanical Mixing Valve BDT Below Deck Thermostatic Mixing Valve Bak-Chek Tee not reqired or provided when a Temperatre Mixing Valve is inclded with the facet. Conslt Factory for Finish Variations Accessories (Specify separately) Adapter SFP-6 110 VAC/6 VDC Plg-in Adapter Spray Head ETF-687 1.5 gpm/5.7 Lpm Laminar Flow Spray Head ETF-801 0.5 gpm/1.9 Lpm Spray Head Grid Strainer ETF-460-A Chrome Plated Brass Grid Strainer w/1¼ Otlet Tbe Atomatic The Sloan OPTIMA Pls EBF-550 Battery Powered Gooseneck Hand Washing Facet operates by means of an infrared sensor. Once the ser s hands enter the sensor s effective range, the Solenoid activates the water flow. Tempered water flows from the Facet ntil hands are moved away. The Facet then atomatically shts off. Hygienic The ltimate in sanitary protection there are no handles to trn or bttons to psh. Helps to control the spread of infectios diseases. Ideal for high traffic commercial installations. Economical Atomatic operation provides water sage savings over other facet devices. Redces maintenance and operation costs. Battery operation ideal for Retrofit installations. Optional plg-in adapter available. Warranty 3 year (limited) Compliant to: ASME A112.18.1-2005/CSA B125.1-05 ISO/IEC 17025 See OPTIMA Accessories Section of the Sloan Catalog for a complete listing of OPTIMA Facet Accessories and Variations. This prodct may contribte to LEED credits. See details on LEED calclation worksheet. This space for Architect/Engineer approval Job Name Model Specified Date Qantity Variations Specified Cstomer/Wholesaler Contractor Architect Optima Pls EBF-550 S.S. Rev. 3a (02/11) The information contained in this docment is sbject to change withot notice.

EBF-550 Back Monted, Battery Powered, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head EBF-550-S-H Srgical Bend ELECTRICAL SPECIFICATIONS Control Circit 6 VDC operates on for (4) alkaline AA-size batteries. Optional 6 VDC Plg-in Adapter. Battery Life 2 years at 8,000 cycles/month Indicator Lights Range Adjstment/Low Battery Solenoid Valve Filtered Solenoid Valve with serviceable Strainer Filter. Optima Sensor Range Factory Set: 4-5 (102 mm - 127 mm) Adjstable: 1-8 (25 mm - 203 mm) Time Ot Adjstment Settings 30 seconds The Facet Time Ot Setting determines the maximm time the facet will rn pon continos detection. The EBF-550 is factory set at the 30 second time ot. Max. Distance Control Modle may be Installed from Spot With Standard Cable: 15 (381 mm) Extension Cable (Optional) EBF-203-A-16 16 (406 mm) OPERATION 1. A continos invisible beam of light is emitted from the OPTIMA Sensor located at the base of the lavatory facet. ROUGH-IN 2. As the ser s hands enter the beam s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing tempered water to flow from the facet. Water will flow ntil the hands are removed or ntil the facet reaches its atomatic time ot limit setting. 3. When hands are moved away from the OPTIMA Sensor, the loss of reflected light initiates an electrical signal that deactivates the Solenoid Valve shtting off the water flow. The Circit then atomatically resets and is ready for the next ser. Rogh-in Dimensions (side view) EBF-550 Facet with Bak-Chek Tee for Hot and Cold Water Spply EBF-550 Facet with BDM and BDT Variation Mixing Valves for Hot and Cold Water Spply SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright 2011 Sloan Valve Company Optima Pls EBF-550 S.S. Rev. 3a (02/11)

Battery Powered Gooseneck Hand Washing Facet EBF-750 Battery Powered, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head Specifications ADA Compliant, Battery Powered, Sensor Activated, Chrome Plated Brass Gooseneck Hand Washing Facet with the following featres: Splash-proof Circit Control Modle Isolated Latching Solenoid Operator, isolates magnetic components from water contact Sensor Range Adjstment Screw Low Battery LED Indicator Light User friendly Variable Time Ot Settings Serviceable Filtered Solenoid Valve Bak-Chek Tee for Hot/Cold Spply Spray Head with Pressre Compensating Flow Control Metal Jacketed Wire Protection for Sensor Lead Incldes for (4) AA-size Alkaline Batteries Appropriate Monting Hardware inclded Optional 6 VDC Plg-in available (Batteries act as backp when sing optional adaptor) Variations (Add sffix to Model Nmber for inclsion with Facet) Spot and Spray Head Variations H Shower Spray Head (2.2 gpm/8.3 Lpm) S Srgical Bend Spot Trim Plate (mst be specified) -4 Trim Plate for 4 Centerset Sink -8 Trim Plate for 8 Centerset Sink Temperatre Mixing Valves (optional) ADM Above Deck Mechanical Mixing Valve (only available for installation on 8 centerset sinks) BDM Below Deck Mechanical Mixing Valve BDT Below Deck Thermostatic Mixing Valve Bak-Chek Tee not reqired or provided when a Temperatre Mixing Valve is inclded with the facet. Conslt Factory for Finish Variations Accessories (Specify separately) SFP-6 120 VAC/6 VDC Plg-in Spray Heads ETF-687 1.5 gpm/5.7 Lpm Laminar Flow Spray Head ETF-801 0.5 gpm/1.9 Lpm Spray Head Grid Strainer ETF-460-A Chrome Plated Brass Grid Strainer w/1¼ Otlet Tbe See OPTIMA Accessories Section of the Sloan Catalog for a complete listing of OPTIMA Facet Accessories and Variations. Job Name ADA Compliant Atomatic The Sloan OPTIMA Pls EBF-750 Battery Powered, Gooseneck Hand Washing Facet operates by means of an infrared sensor. Once the ser s hands enter the sensor s effective range, the Solenoid activates the water flow. Tempered water flows from the Facet ntil hands are moved away. The Facet then atomatically shts off. Hygienic The ltimate in sanitary protection there are no handles to trn or bttons to psh. Helps to control the spread of infectios diseases. Ideal for high traffic commercial installations. Economical Atomatic operation provides water sage savings over other facet devices. Redces maintenance and operation costs. Battery Operation ideal for Retrofit installations. Optional plg-in adaptor available. Warranty 3 year (limited) Compliant to: ASME A112.18.1 This space for Architect/Engineer approval Date Model Specified Qantity Variations Specified Cstomer/Wholesaler Contractor Architect Optima Pls EBF-750 S.S. Rev. 2b (02/11) The information contained in this docment is sbject to change withot notice.

EBF-750 FAUCET DIMENSIONS Battery Powered, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head ELECTRICAL SPECIFICATIONS Control Circit 6 VDC operates on for (4) alkaline AA-size batteries. Optional 6 VDC plg-in. Battery Life 2 years at 8,000 cycles/month Indicator Lights Range Adjstment/Low Battery Optima Sensor Range Factory Set: 4-5 (102 mm - 127 mm) Adjstable: 2-7 (51 mm - 178 mm) Solenoid Valve Filtered Solenoid Valve with serviceable Strainer Filter. Time Ot Adjstment Settings 30 seconds The Facet Time Ot Setting determines the maximm time the facet will rn pon continos detection. The EBF-750 is factory set at the 30 second time ot. Max. Distance Control Modle may be Installed from Spot With Standard Cable: 15 (381 mm) Extension Cable (Optional) EBF-203-A-16 16 (406 mm) OPERATION 1. A continos invisible beam of light is emitted from the OPTIMA Sensor located at the base of the lavatory facet. EBF-750 Facet with Bak-Chek Tee for Hot and Cold Water Spply 2. As the ser s hands enter the beam s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing tempered water to flow from the facet. Water will flow ntil the hands are removed or ntil the facet reachesits atomatic time ot limit setting. EBF-750 Facet with ADM Variation Mixing Valve for Hot and Cold Water Spply (shown with 8 trim plate) 3. When hands are moved away from the Optima Sensor, the loss of reflected light initiates an electrical signal that deactivates the solenoid valve, shtting off the water flow. The circit then atomatically resets and is ready for the next ser. EBF-750 Facet with BDM and BDT Variation Mixing Valves for Hot and Cold Water Spply SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright 2011 Sloan Valve Company Optima Pls EBF-750 S.S. Rev. 2b (02/11)

Sensor Activated Electronic Gooseneck Hand Washing Facet Back Monted, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head Specifications ADA Compliant, Sensor Activated, 24 VAC, Chrome Plated Brass, Gooseneck Hand Washing Facet with the following featres: Splash-proof Circit Control Modle Sensor Range Adjstment Screw Trobleshooting LED Indicator Lights User friendly Variable Time Ot Settings Filtered Solenoid Valve with serviceable Strainer Filter Bak-Chek Tee for Hot/Cold Spply 120 VAC/24 VAC Transformer (specify Plg-in or Box Mont) Spray Head with Pressre Compensating Flow Control Metal Jacketed Wire Protection for Sensor and Solenoid Leads Modlar Qick-Release Sensor and Solenoid Connections Variations (Add sffix to Model Nmber for inclsion with Facet) Spot and Spray Head Variations H Shower Spray Head (2.2 gpm/8.3 Lpm) S Srgical Bend Spot Transformer Type (mst be specified) P Plg-in Transformer (frnished with ETF-233) B Box Mont (frnished with EL-248-40) LT Less Transformer (specify Transformer separately - See Accessories) Temperatre Mixing Valves (optional) BDM Below Deck Mechanical Mixing Valve BDT Below Deck Thermostatic Mixing Valve Bak-Chek Tee not reqired or provided when a Temperatre Mixing Valve is inclded with the facet. Conslt Factory for Finish Variations Accessories (Specify separately) Transformers ETF-233 120 VAC/24 VAC, 50/60 Hz (35 VA) - Plg-in (will operate p to 2 facets) EL-248-40 120 VAC/24 VAC, 50/60 HZ (40 VA) - Box Mont (will operate p to 2 facets) EL-154 120 VAC/24 VAC, 50/60 Hz (50 VA) - Box Mont (will operate p to 3 facets) EL-208 120 VAC/24 VAC, 50/60 Hz (100 VA) - Foot Mont (will operate p to 6 facets) EL-342 240 VAC/24 VAC, 50/60 Hz (50 VA) - Box Mont (will operate p to 3 facets) Spray Head ETF-687 1.5 gpm/5.7 Lpm Laminar Flow Spray Head ETF-801 0.5 gpm/1.9 Lpm Spray Head Grid Strainer ETF-460-A Chrome Plated Brass Grid Strainer w/1¼ Otlet Tbe See OPTIMA Accessories Section of the Sloan Catalog for a complete listing of OPTIMA Facet Accessories and Variations. Job Name ADA Compliant Atomatic The Sloan OPTIMA ETF-500 Electronic Gooseneck Hand Washing Facet operates by means of an infrared sensor. Once the ser s hands enter the sensor s effective range, the Solenoid activates the water flow. Tempered water flows from the Facet ntil hands are moved away. The Facet then atomatically shts off and resets for the next se. Hygienic The ltimate in sanitary protection there are no handles to trn or bttons to psh. Helps to control the spread of infectios diseases. Ideal for health care applications. Economical Atomatic operation provides water sage savings over other facet devices. Redces maintenance and operation costs. Warranty 3 year (limited) Compliant to: ASME A112.18.1 and CSA B125.1 Model Specified Variations Specified Cstomer/Wholesaler Contractor LISTED 376U This space for Architect/Engineer approval Date Qantity Optima ETF-500 S.S. Rev. 2b (05/11) Architect The information contained in this docment is sbject to change withot notice.

Back Monted, Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head ETF-500-S-H Srgical Bend ELECTRICAL SPECIFICATIONS Control Circit 24 VAC Inpt/Otpt, 50/60 Hz, Adjstable Range & Time Ot Settings, Modlar Plgs & Trobleshooting LED Indicators OPTIMA Sensor Range Factory Set: 6-8 (152 mm - 203 mm) Adjstable: 1-14 (25 mm - 356 mm) Solenoid Valve 24 VAC 50/60 Hz with Integral Strainer Filter & Compression Connection Inlet/Otlet. OPERATION 1. A continos invisible beam of light is emitted from the OPTIMA Sensor located at the base of the lavatory facet. ROUGH-IN ETF-500 Facet with Bak-Chek Tee for Hot and Cold Water Spply Time Ot Adjstment Settings 3, 6, 12, 30 & 45 seconds; 1, 3 & 20 mintes. The Facet Time Ot Setting determines the maximm time the facet will rn pon continos activation. This timing can be changed to meet individal application reqirements. Unless otherwise specified the ETF-500 is factory set at the 30 second time ot. 2. As the ser s hands enter the beam s effective range, the beam is reflected back into the sensor receiver and activates the solenoid valve allowing tempered water to flow from the facet. Water will flow ntil the hands are removed or ntil the facet reaches its atomatic time ot limit setting. Transformer All Sloan Transformers are 50/60 Hz. Mltiple facets can be powered by a single transformer, provided that the transformer has been properly sized. Allow a minimm of 15 VA of crrent rating for each facet being sed. Plg-in ETF-233 120 VAC/24 VAC - 35 VA (spplied with P variation) Box Mont EL-248-40 120 VAC/24 VAC - 40 VA (spplied with B variation) Box Mont EL-154 120 VAC/24 VAC - 50 VA Foot Mont EL-208 120 VAC/24 VAC - 100 VA Box Mont EL-342 240 VAC/24 VAC - 50 VA Max. Distance Control Modle may be Installed from Spot With Standard Cable: 12 (305 mm) Extension Cables (Optional) From Sensor to Control Modle: From Solenoid Valve to Control Modle: ETF-1005-26 26 (660 mm) ETF-1003-36 36 (914 mm) ETF-1005-36 36 (914 mm) ETF-1003-48 48 (1219 mm) ETF-1005-72 72 (1829 mm) ETF-1003-72 72 (1829 mm) ETF-1005-108 108 (2743 mm) ETF-1003-108 108 (2743 mm) ETF-500 Facet with BDM and BDT Variation Mixing Valves for Hot and Cold Water Spply 3. When hands are moved away from the OPTIMA Sensor, the loss of reflected light initiates an electrical signal that deactivates the Solenoid Valve shtting off the water flow. The Circit then atomatically resets and is ready for the next ser. Rogh-in Dimensions (side view) SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright 2011 Sloan Valve Company Optima ETF-500 S.S. Rev. 2b (05/11)

Sensor Activated Electronic Gooseneck Hand Washing Facet Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head Specifications ADA Compliant, Sensor Activated, 24 VAC, Chrome Plated Brass, Gooseneck Hand Washing Facet with the following featres: Splash-proof Circit Control Modle Sensor Range Adjstment Screw Trobleshooting LED Indicator Lights User friendly Variable Time Ot Settings Filtered Solenoid Valve with serviceable Strainer Filter Bak-Chek Tee for Hot/Cold Spply 120 VAC/24 VAC Transformer (specify Plg-in or Box Mont) Spray Head with Pressre Compensating Flow Control Metal Jacketed Wire Protection for Sensor and Solenoid Leads Modlar Qick-Release Sensor and Solenoid Connections Variations (Add sffix to Model Nmber for inclsion with Facet) Spot and Spray Head Variations H Shower Spray Head (2.2 gpm/8.3 Lpm) S Srgical Bend Spot Trim Plate (mst be specified) -4 Trim Plate for 4 Centerset Sink -8 Trim Plate for 8 Centerset Sink Transformer Type (mst be specified) P Plg-in Transformer (frnished with ETF-233) B Box Mont (frnished with EL-248-40) LT Less Transformer (specify Transformer separately - See Accessories) Temperatre Mixing Valves (optional) ADM Above Deck Mechanical Mixing Valve (only available for installation on 8 centerset sinks) BDM Below Deck Mechanical Mixing Valve BDT Below Deck Thermostatic Mixing Valve Bak-Chek Tee not reqired or provided when a Temperatre Mixing Valve is inclded with the facet. Conslt Factory for Finish Variations Accessories (Specify separately) Transformers ETF-233 120 VAC/24 VAC, 50/60 Hz (35 VA) - Plg-in (will operate p to 2 facets) EL-248-40 120 VAC/24 VAC, 50/60 HZ (40 VA) - Box Mont (will operate p to 2 facets) EL-154 120 VAC/24 VAC, 50/60 Hz (50 VA) - Box Mont (will operate p to 3 facets) EL-208 120 VAC/24 VAC, 50/60 HZ (100 VA) - Foot Mont (will operate p to 6 facets) EL-342 240 VAC/24 VAC, 50/60 Hz (50 VA) - Box Mont (will operate p to 3 facets) Spray Heads ETF-687 1.5 gpm/5.7 Lpm Laminar Flow Spray Head ETF-801 0.5 gpm/1.9 Lpm Spray Head Grid Strainer ETF-460-A Chrome Plated Brass Grid Strainer w/1¼ Otlet Tbe See OPTIMA Accessories Section of the Sloan Catalog for a complete listing of OPTIMA Facet Accessories and Variations. Optima ETF-700 S.S. Rev. 2 (11/08) Job Name ADA Compliant Atomatic The Sloan OPTIMA ETF-700 Electronic Gooseneck Hand Washing Facet operates by means of an infrared sensor. Once the ser enters the sensor s effective range, the Solenoid activates the water flow. Tempered water flows from the Facet ntil hands are moved away. The Facet then atomatically shts off. Hygienic The ltimate in sanitary protection there are no handles to trn or bttons to psh. Helps to control the spread of infectios diseases. Ideal for health care applications. Economical Atomatic operation provides water sage savings over other facet devices. Redces maintenance and operation costs. Warranty 3 year (limited) Compliant to: ASME A112.18.1 and CSA B125.1 Model Specified Variations Specified Cstomer/Wholesaler Contractor Architect Model ETF-700-H Shown This space for Architect/Engineer approval Date Qantity The information contained in this docment is sbject to change withot notice.

FAUCET DIMENSIONS Sensor Activated Electronic Gooseneck Hand Washing Facet for tempered or hot/cold water operation. 2.2 gpm/8.3 Lpm Laminar Flow Spray Head ELECTRICAL SPECIFICATIONS Control Circit 24 VAC Inpt/Otpt, 50/60 Hz, Adjstable Range & Time Ot Settings, Modlar Plgs & Trobleshooting LED Indicators. OPTIMA Sensor Range Factory Set: 8-10 (203 mm - 254 mm) Adjstable: 1-14 (25 mm - 356 mm) Solenoid Valve 24 VAC 50/60 Hz with integral strainer filter & 3/8 Compression Connection Inlet/Otlet. OPERATION 1. A continos invisible beam of light is emitted from the OPTIMA Sensor located at the base of the lavatory facet. Time Ot Adjstment Settings 3, 6, 12, 30 & 45 seconds; 1, 3 & 20 mintes. The Facet Time Ot Setting determines the maximm time the facet will rn pon continos activation. This timing can be changed to meet individal application reqirements. Unless otherwise specified the ETF-700 is factory set at the 30 second time ot. 2. As the ser s hands enter the beam s effective range, the beam is reflected back into the sensor receiver and activates the Solenoid Valve allowing tempered water to flow from the facet. Water will flow ntil the hands are removed or ntil the facet reaches its atomatic time ot limit setting. Transformer All Sloan Transformers are 50/60 Hz. Mltiple facets can be powered by a single transformer, provided that the transformer has been properly sized. Allow a minimm of 15 VA of crrent rating for each facet being sed. Plg-in ETF-233 120 VAC/24 VAC - 35 VA (spplied with P variation) Box Mont EL-248-40 120 VAC/24 VAC - 40 VA (spplied with B variation) Box Mont EL-154 120 VAC/24 VAC - 50 VA Foot Mont EL-208 120 VAC/24 VAC - 100 VA Box Mont EL-342 240 VAC/24 VAC - 50 VA Max. Distance Control Modle may be Installed from Spot With Standard Cable: 12 (305 mm) Extension Cables (Optional) From Sensor to Control Modle: From Solenoid Valve to Control Modle: ETF-1005-26 26 (660 mm) ETF-1003-36 36 (914 mm) ETF-1005-36 36 (914 mm) ETF-1003-48 48 (1219 mm) ETF-1005-72 72 (1829 mm) ETF-1003-72 72 (1829 mm) ETF-1005-108 108 (2743 mm) ETF-1003-108 108 (2743 mm) 3. When hands are moved away from the OPTIMA Sensor, the loss of reflected light initiates an electrical signal that deactivates the Solenoid Valve, shtting off the water flow. The Circit then atomatically resets and is ready for the next ser. ETF-700 Facet with Bak-Chek Tee for Hot and Cold Water Spply ETF-700 Facet with ADM Variation Mixing Valve for Hot and Cold Water Spply (shown with 8 trim plate) ETF-700 Facet with BDM and BDT Variation Mixing Valves for Hot and Cold Water Spply SLOAN VALVE COMPANY 10500 SEYMOUR AVENUE FRANKLIN PARK, IL 60131 Phone: 1-800-982-5839 or 1-847-671-4300 Fax: 1-800-447-8329 or 1-847-671-4380 www.sloanvalve.com Copyright 2008 Sloan Valve Company Optima ETF-700 S.S. Rev. 2 (11/08)