DIESEL GENERATOR SETS

Similar documents
DIESEL GENERATOR SET. 60 Hz FEATURES

D I E S E L G E N E R A T O R S E T S

60 Hz FEATURES. Exclusively from your Caterpillar dealer

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Standby kw Prime kw

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

GEPH17SP (1-Phase) 50 HZ 17.5 kva / 17.5 kw FEATURES. Exclusively from your Caterpillar dealer

STANDBY kw PRIME kw

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

STANDBY 200 ekw 250 kva

STANDBY 200 ekw 250 kva

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

STANDBY 80 ekw 100 kva PRIME 72 ekw 90 kva

Generator Set Specifications 100 ekw (125 kva)

XQ80 RENTAL. 60 Hz FEATURES

Generator Set Specifications 60 ekw (75 kva)

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Specifications. 3406C Generator Set Electric Power

Bore mm 4.0 in Displacement 5.7 L 350 in³ Stroke 88.4 mm 3.48 in Compression Ratio 9.4:1

XQ60 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

DIESEL GENERATOR SET FEATURES

Voltage 208 to 600. Engine Specifications C27 ATAAC, V-12, 4-Stroke, Water-Cooled Diesel Compression Ratio 16.5:1 Aspiration

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

Voltage 220 to or 1800 RPM

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

XQ175 RENTAL. 60 Hz FEATURES EPA TIER 3 AND CARB CERTIFIED FOR NON-ROAD MOBILE APPLICATIONS

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

220 to volts. Electronic unit injection

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

Cat C32 Diesel Generator Sets

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

Continuous, Prime, Standby, Mission Critical

STANDBY 400 ekw 500 kva

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 225 ekw 281 kva

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

400 to 11,000 Volts. Standby, Prime, Continuous

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

Specifications. C13 Generator Set Electric Power

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Cat 3412 Diesel Generator Sets

Cat C32 Diesel Generator Sets

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

Cat C32 Diesel Generator Sets

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

DIESEL FEATURES GENERATOR SET

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

Enclosures. Options Caterpillar yellow or white paint Integral dual wall fuel tank base for total fluid containment (fuel, oil and coolant)

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

Package Performance Genset Power Rating with 0.8 Power Factor Genset Power Rating Aftercooler (Separate Circuit) N/A N/A

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

Transcription:

DIESEL GENERATOR SETS STANDBY Model Standby Prime kw (kva) kw (kva) D25-6 25 (31.3) 22.8 (28.5) D25-6S 25 (25) 22.5 (22.5) D30-8 30 (37.5) 27 (33.8) D30-6S 30 (30) 27 (27) Tier 2 EPA Approved, Emissions Certified FEATURES GENERATOR SET Complete system designed and built at ISO 9001 certified facilities Factory tested to design specifications at full load conditions ENGINE Governor, mechanical Electrical system, 12 VDC Cartridge type filters Battery rack and cables Coolant and lube drains piped to edge of base GENERATOR Insulation system, class H Drip proof generator air intake (NEMA 2, IP23) Electrical design in accordance with BS5000 Part 99, IEC60034-1, EN61000-6, NEMA MG-1.33 CONTROL SYSTEM EMCP 3.1 digital control panel Vibration isolated NEMA 1 enclosure with lockable hinged door DC and AC wiring harnesses Picture shown may not reflect actual package. MOUNTING ARRANGEMENT Heavy-duty fabricated steel base with lifting points Anti-vibration pads to ensure vibration isolation Complete OSHA guarding Stub-up pipe ready for connection to silencer pipework Flexible fuel lines terminated at skid base with NPT connections COOLING SYSTEM Radiator and cooling fan complete with protective guards Standard ambient temperatures up to 50 C (122 F) CIRCUIT BREAKER UL/CSA listed 3-pole with solid neutral NEMA 1 steel enclosure, vibration isolated Electrical stub-up area directly below circuit breaker AUTOMATIC VOLTAGE REGULATOR Voltage within ± 0.5% 3 phase and ± 1.0% single phase at steady state from no load to full load Provides fast recovery from transient load changes EQUIPMENT FINISH All electroplated hardware Anticorrosive paint protection High gloss polyurethane paint for durability and scuff resistance QUALITY STANDARDS BS4999, BS5000, BS5514, IEC60034, EN61000-6, NEMA MG-1.33, NFPA 110 (with optional equipment) DOCUMENTATION Operation and maintenance manuals provided Wiring diagrams included WARRANTY All equipment carries full manufacturer s warranty LEHE5533-00

OPTIONAL EQUIPMENT* ENCLOSURE B Series weather protective enclosure (includes internal silencer system) Sound attenuated enclosure (includes internal silencer system) Super sound attenuated enclosure (includes internal silencer system) Panel viewing window External emergency stop pushbutton SILENCER SYSTEM OPEN UNIT Level 1 silencer Level 2 silencer Level 3 silencer Mounting kit Through-wall installation kits ENGINE Electronic governor Battery heater Lube oil drain pump Lube oil sump heater CIRCUIT BREAKER Auxiliary voltfree contacts Shunt trip (100+ amp breakers) MOUNTING ACCESSORIES Seismic (Zone 4) vibration isolators GENERATOR Anti-condensation heater AREP excitation system (D25-6, D30-8) Generator upgrade 1 size (D25-6, D30-8) CONTROL SYSTEM No control system EMCP 3.2 digital control panel FUEL SYSTEM Single-walled steel fuel tank UL listed closed top-diked skid-mounted fuel tank base (24-hour capacity) with fuel alarm (low level/leak detected) Critical high fuel alarm Low fuel level alarm and shutdown REMOTE ANNUNCIATORS Remote annunciator panel (supplied loose) COOLING SYSTEM Coolant heater Low coolant temperature alarm Low coolant level shutdown Radiator transition flange MISCELLANEOUS ACCESSORIES Toolkit Additional operator s manual pack Special enclosure color UL listing CSA certification French or Spanish language labels EXTENDED SERVICE CONTRACTS Extended service coverage available * Some options may not be available on all models. Not all options are listed. GENERATOR SET DIMENSIONS AND WEIGHTS H L W Model Length mm (in) Width mm (in) Height mm (in) Weight kg (lb)* D25-6 1770 (69.7) 714 (28.1) 1360 (53.5) 780 (1,720) D25-6S 1770 (69.7) 714 (28.1) 1360 (53.5) 780 (1,720) D30-8 1770 (69.7) 714 (28.1) 1360 (53.5) 790 (1,742) D30-6S 1770 (69.7) 714 (28.1) 1360 (53.5) 790 (1,742) NOTE: General configuration not to be used for installation. See specific dimensional drawings for detail. Dimensions and weights shown are for the open skid configuration. *Includes oil and coolant LEHE5533-00 2 2

SPECIFICATIONS GENERATOR Voltage regulation...±0.5% 3 PH and ± 1% Single PH at steady state from no load to full load Frequency... ± 0.8% for constant load, no load to full load Waveform distortion...thd < 4%, at no load Radio interference...compliance with EN61000-6 Telephone interference... TIF < 50, THF < 2% Overspeed limit...2250 rpm Insulation... Class H Temperature rise... Within Class H limits Available voltages... 1-phase 120/240, 115/230, 110/220 3-phase 277/480, 120/240, 127/220, 120/208 Deration... Consult factory for available outputs Ratings... At 30 C (86 F), 152.4 m (500 ft), 60% humidity, 1.0 pf (1-phase), 0.8 pf (3-phase) ENGINE Manufacturer... Caterpillar Type... 4-cycle Aspiration... Natural Stroke mm (in)... 127 (5.0) Piston speed m/sec (ft/sec)... 7.62 (25.0) Engine speed rpm... 1800 Air cleaner type... Dry, replaceable paper element type with restriction indicator D25-6, D25-6S, D30-8, D30-6S C3.3 Cylinder configuration...in-line 3 Displacement L (cu in)... 3.3 (202) Bore mm(in)... 105 (4.13) Compression ratio... 19.3:1 Governor Type... Mechanical and electrical Class...G2 and G3 Max power at rated rpm kw (hp) Standby...35(46.9) Prime...31.5 (42.2) BMEP kpa (psi) Standby...735 (106.6) Prime...660 (95.7) Regenerative power kw (hp)... 9.0 (12.0) CONTROL PANEL Heavy duty sheet steel enclosure with lockable hinged door Vibration isolated from generating set LCD display AC metering DC metering Fail to start shutdown Low oil pressure shutdown High engine temperature Low/high battery voltage Underspeed/overspeed Loss of engine speed detection 2 spare fault channels 20 event fault log 2 LED status indicators Lockdown emergency stop push button RATING DEFINITIONS AND CONDITIONS Standby Applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The generator is peak rated (as defined in ISO8528-3). Prime Applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and the generator set can supply 10 percent overload power for 1 hour in 12 hours. LEHE5533-00 3

D25-6 (3-Phase) Materials and specifications are subject to change without notice. Generator Set Technical Data 1800 rpm/ Standby Prime Power Rating kva kw 31.3 25 28.5 22.8 Lubricating System Type: full pressure Oil filter: spin-on, full flow Oil cooler: Modine Oil type required: API CG-4 or CH-4 Total oil capacity L U.S. gal 8.3 2.19 8.3 2.19 Oil pan L U.S. gal 7.8 2.06 7.8 2.06 Fuel System Generator set fuel consumption 100% load L/hr gal/hr 8.4 2.2 7.7 2.0 75% load L/hr gal/hr 6.5 1.7 5.9 1.6 50% load L/hr gal/hr 4.5 1.2 4.2 1.1 Engine Electrical System Voltage/ground: 12/negative Battery charging generator ampere rating amps 65 65 Cooling System Water pump type: centrifugal Radiator system capacity incl. engine L U.S. gal 10.2 2.69 10.2 2.69 Maximum coolant static head m H 2 O ft H 2 O 10.2 33.2 10.2 33.2 Coolant flow rate L/hr U.S. gal/hr 9060 1,993 9060 1,993 Minimum temperature to engine C F 70 158 70 158 Temperature rise across engine C F 1.9 3.4 1.9 3.4 Heat rejected to coolant at rated power kw Btu/min 19.0 1,103 17.0 955 Total heat radiated to room at rated power kw Btu/min 9.0 500 8.0 427 Radiator fan load kw hp 0.5 0.7 0.5 0.7 Air Requirements Combustion air flow m 3 /min cfm 2.6 91.8 2.6 91.8 Maximum air cleaner restriction kpa in H 2 O 6.6 26.5 6.6 26.5 Radiator cooling air (zero restriction) m 3 /min cfm 109 3,856 109 3,856 Generator cooling air m 3 /min cfm 10.8 382 10.8 382 Allowable air flow restriction (after radiator) kpa in H 2 O 0.12 0.5 0.12 0.5 Cooling airflow (@ rated speed) Rate with restriction m 3 /min cfm 86.7 3,062 86.7 3,062 Exhaust System Maximum allowable backpressure kpa in Hg 15 4.43 15 4.43 Exhaust flow at rated kw m 3 /min cfm 6.52 230 6.1 215 Exhaust temperature at rated kw Dry exhaust C F 580 1,079 530 986 Generator Set Noise Rating* (without attenuation) at 1 m (3 ft) db(a) 92.4 92.1 Generator Technical Data 277/480V 120/240V 120/208V 127/220V 347/600V Motor Starting Capability: (kva) (30% voltage dip) Self excited 67 53 58 N/A AREP excited 81 64 70 128 Full Load Efficiencies: Standby 89.7 89.0 89.4 89.7 Prime 89.9 89.3 89.7 89.6 Reactances (per unit): X d 1.89 2.51 2.25 1.66 X' d 0.10 0.14 0.12 0.07 Reactances X" d 0.052 0.069 0.062 0.037 shown are X q 0.94 1.26 1.12 0.99 applicable to the X" q 0.073 0.098 0.087 0.046 standby rating. X 2 0.063 0.085 0.076 0.041 X 0 0.005 0.007 0.006 0.003 Time Constants: t'd t"d t'do ta 25 ms 2.5 ms 452 ms 4 ms * db(a) levels are for guidance only LEHE5533-00 4

D25-6S (1-Phase) Materials and specifications are subject to change without notice. Generator Set Technical Data 1800 rpm/ Standby Prime Power Rating kva kw 25 25 22.5 22.5 Lubricating System Type: full pressure Oil filter: spin-on, full flow Oil cooler: Modine Oil type required: API CG-4 or CH-4 Total oil capacity L U.S. gal 8.3 2.19 8.3 2.19 Oil pan L U.S. gal 7.8 2.06 7.8 2.06 Fuel System Generator set fuel consumption 100% load L/hr gal/hr 8.5 2.2 7.7 2.0 75% load L/hr gal/hr 6.5 1.7 5.9 1.6 50% load L/hr gal/hr 4.5 1.2 4.2 1.1 Engine Electrical System Voltage/ground: 12/negative Battery charging generator ampere rating amps 65 65 Cooling System Water pump type: centrifugal Radiator system capacity incl. engine L U.S. gal 10.2 2.69 10.2 2.69 Maximum coolant static head m H 2 O ft H 2 O 10.2 33.2 10.2 33.2 Coolant flow rate L/hr U.S. gal/hr 9060 1,993 9060 1,993 Minimum temperature to engine C F 70 158 70 158 Temperature rise across engine C F 1.9 3.4 1.9 3.3 Heat rejected to coolant at rated power kw Btu/min 19.0 1,103 17.0 955 Total heat radiated to room at rated power kw Btu/min 9.0 500 8.0 427 Radiator fan load kw hp 0.5 0.7 0.5 0.7 Air Requirements Combustion air flow m 3 /min cfm 2.6 91.8 2.6 91.8 Maximum air cleaner restriction kpa in H 2 O 6.6 26.5 6.6 26.5 Radiator cooling air (zero restriction) m 3 /min cfm 109 3,856 109 3,856 Generator cooling air m 3 /min cfm 10.8 382 10.8 382 Allowable air flow restriction (after radiator) kpa in H 2 O 0.12 0.5 0.12 0.5 Cooling airflow (@ rated speed) Rate with restriction m 3 /min cfm 86.7 3,062 86.7 3,062 Exhaust System Maximum allowable backpressure kpa in Hg 15 4.43 15 4.43 Exhaust flow at rated kw m 3 /min cfm 6.52 230 6.1 215 Exhaust temperature at rated kw Dry exhaust C F 580 1,079 530 986 Generator Set Noise Rating* (without attenuation) at 1 m (3 ft) db(a) 92.4 92.1 Generator Technical Data 120/240V 115/230V 110/220V Motor Starting Capability: (kva) (30% voltage dip) Self excited 40 38 35 Full Load Efficiencies: Standby 88.0 87.2 86.5 Prime 88.5 87.9 87.3 Reactances (per unit): X d 2.08 2.27 2.48 X' d 0.25 0.27 0.30 Reactances shown X" d 0.125 0.136 0.149 are applicable to X q 1.04 1.13 1.24 the standby rating. X" q 0.176 0.192 0.210 Time Constants: * db(a) levels are for guidance only t'd t"d t'do ta 40 ms 6 ms 380 ms 8 ms LEHE5533-00 5

D30-8 (3-Phase) Materials and specifications are subject to change without notice. Generator Set Technical Data 1800 rpm/ Standby Prime Power Rating kva kw 37.5 30 33.8 27 Lubricating System Type: full pressure Oil filter: spin-on, full flow Oil cooler: Modine Oil type required: API CG-4 or CH-4 Total oil capacity L U.S. gal 8.3 2.19 8.3 2.19 Oil pan L U.S. gal 7.8 2.06 7.8 2.06 Fuel System Generator set fuel consumption 100% load L/hr gal/hr 9.9 2.6 9.0 2.4 75% load L/hr gal/hr 7.6 2.0 6.9 1.8 50% load L/hr gal/hr 5.3 1.4 4.8 1.3 Engine Electrical System Voltage/ground: 12/negative Battery charging generator ampere rating amps 65 65 Cooling System Water pump type: centrifugal Radiator system capacity incl. engine L U.S. gal 10.2 2.69 10.2 2.69 Maximum coolant static head m H 2 O ft H 2 O 10.2 33.2 10.2 33.2 Coolant flow rate L/hr U.S. gal/hr 9060 1,993 9060 1,993 Minimum temperature to engine C F 70 158 70 158 Temperature rise across engine C F 2.0 3.6 2.0 3.6 Heat rejected to coolant at rated power kw Btu/min 22.0 1,228 19.0 1,092 Total heat radiated to room at rated power kw Btu/min 10.00 552 8.0 478 Radiator fan load kw hp 0.5 0.7 0.5 0.7 Air Requirements Combustion air flow m 3 /min cfm 2.6 91.8 2.6 91.8 Maximum air cleaner restriction kpa in H 2 O 6.6 26.5 6.6 26.5 Radiator cooling air (zero restriction) m 3 /min cfm 109 3,856 109 3,856 Generator cooling air m 3 /min cfm 10.8 382 10.8 382 Allowable air flow restriction (after radiator) kpa in H 2 O 0.12 0.5 0.12 0.5 Cooling airflow (@ rated speed) Rate with restriction m 3 /min cfm 86.7 3,062 86.7 3,062 Exhaust System Maximum allowable backpressure kpa in Hg 15 4.43 15 4.43 Exhaust flow at rated kw m 3 /min cfm 9.58 338 8.80 311 Exhaust remperature at rated kw Dry exhaust C F 580 1,079 530 986 Generator Set Noise Rating* (without attenuation) at 1 m (3 ft) db(a) 93.1 92.6 Generator Technical Data 277/480V 120/240V 120/208V 127/220V 347/600V Motor Starting Capability: (kva) (30% voltage dip) Self excited 70 55 61 N/A AREP excited 84 66 73 128 Full Load Efficiencies: Standby 90.0 88.9 89.4 89.7 Prime 90.3 89.4 89.8 89.7 Reactances (per unit): X d 2.21 2.94 2.63 1.99 X' d 0.12 0.16 0.14 0.09 Reactances X" d 0.059 0.078 0.070 0.044 shown are X q 1.10 1.47 1.31 1.19 applicable to the X" q 0.082 0.109 0.098 0.055 standby rating. X 2 0.070 0.094 0.084 0.049 X 0 0.005 0.007 0.007 0.003 Time Constants: t'd t"d t'do ta 25 ms 2.5 ms 469 ms 4 ms * db(a) levels are for guidance only LEHE5533-00 6

D30-6S (1-Phase) Materials and specifications are subject to change without notice. Generator Set Technical Data 1800 rpm/ Standby Prime Power Rating kva kw 30 30 27 27 Lubricating System Type: full pressure Oil filter: spin-on, full flow Oil cooler: Modine Oil type required: API CG-4 or CH-4 Total oil capacity L U.S. gal 8.3 2.19 8.3 2.19 Oil pan L U.S. gal 7.8 2.06 7.8 2.06 Fuel System Generator set fuel consumption 100% load L/hr gal/hr 9.8 2.6 9.0 2.4 75% load L/hr gal/hr 7.6 2.0 6.9 1.8 50% load L/hr gal/hr 5.3 1.4 4.9 1.3 Engine Electrical System Voltage/ground: 12/negative Battery charging generator ampere rating amps 65 65 Cooling System Water pump type: centrifugal Radiator system capacity incl. engine L U.S. gal 10.2 2.69 10.2 2.69 Maximum coolant static head m H 2 O ft H 2 O 10.2 33.2 10.2 33.2 Coolant flow rate L/hr U.S. gal/hr 9060 1,993 9060 1,993 Minimum temperature to engine C F 70 158 70 158 Temperature rise across engine C F 2.0 3.6 2.0 3.6 Heat rejected to coolant at rated power kw Btu/min 22.0 1,228 19.0 1,092 Total heat radiated to room at rated power kw Btu/min 10.0 552 8.0 478 Radiator fan load kw hp 0.5 0.7 0.5 0.7 Air Requirements Combustion air flow m 3 /min cfm 2.6 91.8 2.6 91.8 Maximum air cleaner restriction kpa in H 2 O 6.6 26.5 6.6 26.5 Radiator cooling air (zero restriction) m 3 /min cfm 109 3,856 109 3,856 Generator cooling air m 3 /min cfm 10.8 382 10.8 382 Allowable air flow restriction (after radiator) kpa in H 2 O 0.12 0.5 0.12 0.5 Cooling airflow (@ rated speed) Rate with restriction m 3 /min cfm 86.7 3,062 86.7 3,062 Exhaust System Maximum allowable backpressure kpa in Hg 15 4.43 15 4.43 Exhaust flow at rated kw m 3 /min cfm 6.52 230 6.1 215 Exhaust temperature at rated kw Dry exhaust C F 580 1,079 530 986 Generator Set Noise Rating* (without attenuation) at 1 m (3 ft) db(a) 93.1 92.6 Generator Technical Data 120/240V 115/230V 110/220V Motor Starting Capability: (kva) (30% voltage dip) Self excited 61 58 54 Full Load Efficiencies: Standby 89.4 88.9 88.3 Prime 89.8 89.4 88.9 Reactances (per unit): X d 1.66 1.80 1.97 X' d 0.19 0.20 0.22 Reactances shown X" d 0.094 0.102 0.112 are applicable to X q 0.83 0.90 0.99 the standby rating. X" q 0.130 0.142 0.155 Time Constants: * db(a) levels are for guidance only t'd t"d t'do ta 40 ms 6 ms 400 ms 8 ms LEHE5533-00 7

This page intentionally left blank. Information contained in this publication may be considered confidential Market: N. America Discretion is recommended when distributing. Materials and specifications are subject to change without notice. 2006 Caterpillar LEHE5533-00 (01-06) CAT, CATERPILLAR, their respective logos and Caterpillar Yellow, as well as corporate and product All Rights Reserved. identity used herein, are trademarks of Caterpillar and may not be used without permission. Printed in U.S.A.