INSTRUCTION MANUAL MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

Similar documents
AUTO CHARGE 1200 PUMP PLUS

INSTRUCTION MANUAL AUTO CHARGE MODEL # OUTPUT: 15 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL REMOTE OUTPUT: 40 AMPERES 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

INSTRUCTION MANUAL ENGINE IDLER MODEL # VOLTGAE MONITOR MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

AUTO CHARGE 12 DV AUTOMATIC BATTERY CHARGER

SUPER 30 AUTO EJECT 30 AMP MODEL #: AUTOMATIC SHORE LINE DISCONNECT INSTRUCTION MANUAL

DUAL 12 Volt-10 Amp AUTOMATIC BATTERY CHARGER

INSTRUCTION MANUAL ENGINE IDLER MODEL # YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC.

AUTO CHARGE 11HO PIM AUTOMATIC BATTERY CHARGER

INDUSTRIAL CHARGER AUTOMATIC BATTERY CHARGER SERIES 150 KUSSMAUL ELECTRONICS CO., INC. MODEL # XX YEAR WARRANTY INSTRUCTION MANUAL

AUTO CHARGE LPC SERIES

INSTRUCTION MANUAL MODEL # NOTE : This charger is designed for vehicles with dual batteries and negative ground.

INSTRUCTION MANUAL AUTO-PUMP 220/240 VAC MODEL #091-9B-220. INPUT :220/240 volt, 50/60 Hz, 1.9/2.2 AMPS OUTPUT: 100 PSI MAXIMUM 1 YEAR WARRANTY

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

BATTERY SAVER LR HO with USB LOW RIPPLE POWER SUPPLY / AUTOMATIC LOAD SWITCH FOR 12VDC VEHICLE SYSTEMS

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

AUTO CHARGE 12HO-PIM AUTOMATIC BATTERY CHARGER

HIGH PRESSURE AIR COMPRESSOR SYSTEM MODEL #: 091-9HP-220 INPUT:

INSTRUCTION MANUAL CAUTION

AUTO-PUMP 120 VAC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. 170 Cherry Avenue West Sayville, NY

INSTRUCTION MANUAL. A battery protector for vehicles with equipment that Is operated with the engine not running. MODEL# INPUT: 12 Volts D.C.

AUTO PUMP 12V MODEL #: V 12 VOLT DC AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL. INPUT: Volts DC, 11 Amps OUTPUT: 100 PSI Max

AUTO-PUMP 12V HP-VER FOR VERTICAL MOUNT ONLY MODEL #: V-HP-VER 12VDC HIGH OUTPUT AIR COMPRESSOR SYSTEM INSTRUCTION MANUAL

AUTO PUMP STATUS CENTER

AUTO REEL -AS MODEL #: AS AUTOMATIC CORD REEL WITH AUTO SAFE INSTRUCTION MANUAL

SUPER AUTO EJECT DELUXE COVER WITH DIGITAL DISPLAY

AUTO EJECT WP MODEL #: WP-012 MODEL #: WP-120 MODEL #: WP-120 AUTOMATIC SHORELINE DISCONNECT INSTRUCTION MANUAL

AUTO CHARGE 12 HO MODEL #: MODEL #: MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE DUAL MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

AUTO CHARGE 4000 MODEL #: LOW PROFILE CHARGER AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE D PUMP PLUS

LPC 20 MODEL #: LOW PROFILE CHARGER AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

BATTERY SAVER LOW RIPPLE HO

Power Distribution System User s Manual. Model: PDS-100

PUMP PLUS 2000 PLC MODEL #: PP AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

PUMP PLUS 1000 PLC MODEL #: PP AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

LPC 40 MODEL #: LOW PROFILE CHARGER WITH PLC AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

SUPER 30 AUTO EJECT -AE

SUPER AUTO EJECT AUTOMATIC SHORELINE DISCONNECT 3 YEARS WARRANTY. Assembled in the UK by LUDO McGURK TRANSPORT EQUIPMENT LTD WILMSLOW - U.K.

THE SUPER 16 AUTO EJECT

MAXIGARD A2000 SPEED SWITCH. Introduction

PUMP PLUS 1200 MODEL #: AUTOMATIC SINGLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

A5000GEC-24VDC ZERO SPEED SWITCH

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

INSTALLATION & OWNER'S MANUAL

Operations Manual. Zero Speed Switch Sensor Model ZS09P

FAN-STOP INSTRUCTION MANUAL

FUSE PANEL Technical Practice FDP /20 GMT NEBS Level 3 Certified

RCL-7A. User s Guide. Battery Charging Station. Technology in Depth

# Traction Control Window Switch



THE 4481 ADJUSTABLE TIMED OUTPUT MACHINE CONTROL

Wiring Installation Instructions for : Pressure. Wiring Installation Instructions for : Temperature. 2 1/16 Spek Pro Professional Racing Gauge

Crossover WARRANTY AND DISCLAIMER

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

TRAILER AUXILIARY POWER SYSTEM (TAPS) INSTALLATION GUIDE V1.10

ELECTRICAL SYSTEM RP-7

Generator Start Control Module

SRC. An Outdoor Reset Control for Sub-Atmosphere Steam Systems OUTDOOR TEMPERATURE

DC Distribution Panel User Guide # S

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

ODY-19-1 AIR PRESSURE GAUGE

HLY-1111 HEAD TEMPERATURE GAUGE

INTERNATIONAL 3200 AND Freightliner MB

1200+ WITH TIMER V1.00 OWNERS MANUAL

1014-CTC WARRANTY AND DISCLAIMER

1014-SCR WARRANTY AND DISCLAIMER Fillmore Street Davenport, Ia

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

SHORT-STOP. Electronic Motor Brake Type G. Instructions and Setup Manual

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

AUTO CHARGE AMPS DELUXE AUTOMATIC BATTERY CHARGER. Section 1: Single Battery Systems

This document describes:

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

AIRSTREAM - BATTERY CONTROL CENTER - Diesel

INSTALLATION/OWNERS MANUAL

C3000 SIGNAL TRANSMITTER. Introduction

Noran Tel. a subsidiary of Westell Inc. Fuse Panel Technical Practice NPGMT /10 GMT NEBS Level 3 Verified

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

Application Engineering

Application Engineering

Battery Control Center - Diesel

BP1204 INSTALLATION/OWNER'S MANUAL

OWNERS MANUAL JANUARY 2007 ISO

Generator Start Control Module

50 AMP Smart Energy Management System Model 900 INSTALLATION & SERVICE MANUAL 50 AMP SMART EMS

For a proper and safe Installation Read the entire manual before Installation

ADI-125/750 ADI-125/1500 ADI-125/2500

Pay For Water System DU 1A046A

ICM 326HN/327HN Line Voltage Head Pressure Control Installation, Operation & Application Guide

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

MODEL 422 Submersible Pump Controller

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) V1.00 OWNERS MANUAL

Radian Research, Inc. makes no warranty on the accuracy of the information contained in this Operations Manual and accepts no liability for its use.

Transcription:

FILE: 091-84.pmd DATE: 9-21-07 INSTRUCTION MANUAL AUTO THROTTLE 1 MODEL #091-84 AN AUTOMATIC HIGH IDLE CONTROLLER 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO., INC. 170 CHERRY AVE., WEST SAYVILLE, N.Y. 11796 Telephone: 631-567-0314 Toll Free: 800-346-0857 Fax: 631-567-5826 Web: www.kussmaul.com E-Mail: sales@kussmaul.com

INTRODUCTION The 091-84 Auto Throttle 1 is a voltage sensor designed to detect when insuffecient alternator ouput causes the battery voltage to drop. Whenever the Auto Throttle 1 is selected the battery voltage is monitored. When this voltage drops below 12.5 volts for a period of 15 seconds, the Auto Throttle 1 relay will close. Once the Auto Throttle 1 relay is operated it will always remain closed for a period of 5 minutes or until the sensed voltage rises above 13.4 volts, whichever occurs later. If the sensed voltage rises above 13.4 volts before the end of the 5 minute interval, then the relay will drop out at the completion of the 5 minutes. However, if the voltage has not attained 13.4 volts when the timer times out, the relay will remain energized as long as required for the battery to reach 13.4 volts. Red and Green indicator lights are provided to indicate the status and assist at installation. The Green LED is lit whenever the Auto Throttle 1 is enabled. When low voltage is detected for more than 15 seconds, the relay is energized, the Red LED lights and the Green LED is extinguished. The Installer is cautioned that this device contains no interlocks. Safety Interlocks must be provided to assure that the Auto Throttle 1 does not inadvertently advance the throttle. It is suggested that the interlock interrupt the 12 volt DC. This will insure that all timing cicuits in the Auto Throttle 1 are reset when it is enabled. Typical installations appear in Figures 1, 2, and 3.

To +12 Volt Sensing Point Auto Throttle 1 Output Relay - N.O. Contact - 30 Amps Max. N. C. Contact - 20 Amps Max. N.C. N.O. COM. Red LED indicates Low Voltage has been Detected and illuminates when relay is energized 1 2 Green LED indicates Voltage is normal and illuminates when relay is de-energized Auto Throttle 1 Select Switch Interlock Switch Close to Enable Auto Throttle 1 Figure 1 - Auto Throttle 1 Typical Installation

To +12 Volt Sensing Point Solenoid Valve Auto Throttle 1 Output Relay - N.O. Contact - 30 Amps Max. N. C. Contact - 20 Amps Max. N.C. N.O. COM. +12 Volts Red LED indicates Low Voltage has been Detected and illuminates when relay is energized 1 2 Green LED indicates Voltage is normal and illuminates when relay is de-energized 30 87 Auto Throttle 1 Select Switch +12 Volts 85 REL0322 86 To Ground Through Neutral Safety Switch Figure 2 - Auto Throttle 1 Typical Installation with Isolation Relay and Neutral Safety Switch that Supplies +12 Volts

To +12 Volt Sensing Point Solenoid Valve Auto Throttle 1 Output Relay - N.O. Contact - 30 Amps Max. N. C. Contact - 20 Amps Max. N.C. N.O. COM. +12 Volts Red LED indicates Low Voltage has been Detected and illuminates when relay is energized 1 2 Green LED indicates Voltage is normal and illuminates when relay is de-energized 30 87 Auto Throttle 1 Select Switch 85 REL0322 86 To +12 Volts From Neutral Safety Switch Figure 3 - Auto Throttle 1 Typical Installation with Isolation Relay and Neutral Safety Switch that Supplies +12 Volts

INSTALLATION RECORD & WARRANTY Date Installed Installed By Vehicle Identification Vehicle Owner WARRANTY All products of Kussmaul Electronics Company Inc. are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects which become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. Kussmaul Electronics Company, Inc. shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. products. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others.