HDE 4000-DM. Electrohydraulic high-pressure unit without pressure intensifier in modular design

Similar documents
HDE 4000-D. Electrohydraulic high-pressure unit without pressure intensifier in mobile design. HDE 4000-D /DM 4000 bar direct power in smallest space.

ExpaTen The ideal connecting bolt Free from backlash Powerful Reusable. ExpaTen more than just a bolt.

Cut-to-size saw fh6 430 / 160 Auto load

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

Application. Battery. Public Grid GS HYBRID INVERTER

Intelligent CST Drive System

HYDRUS ULTRASONIC METER

INTELLITROL. scully. Scully s Intellitrol System. Intellitrol is a state of the art microprocessor based system that provides:

RAY COMPACT ENERGY METER MECHANICAL

130 KW / 165 KVA POWERED by

PowerCommand 3300 Control Panel. Our Energy Is Working For You.

Hydraulic Deadweight Tester Model CPB5800

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01 MB-D(LE) 053 B01

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

WESAN WPV E ELECTRONIC METER WOLTMAN

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) 403 B01

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

IFOA Integral Flow Orifice Assembly

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function MB-ZRD(LE) B01

SCR Variable Speed Series Rotary Screw Compressor

STREAMLINE SL-VI 60,000psi/15hp

DOLI's STANDARD COMPRESSION FLEXOMETER (GOODRICH FLEXOMETER)

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function Integrated bypass valve MB-D(LE) B07

LOW VOLTAGE WIND CONVERTERS. ABB wind turbine converters ACS880, 800 kw to 8 MW

High-Tech Waterjet Cutting

GasMultiBloc Combined regulator and safety shut-off valves Single-stage function MB-D(LE) B01

HYDRUS ULTRASONIC METER

LAUDA Variocool. Numerous options, compact design, easy operation

CORONA E ELECTRONIC METER MULTI-JET

COMPRESSOR SYSTEMS MADE IN GERMANY COMBI SCREW COMPRESSORS

GasMultiBloc Combined regulator and safety shut-off valves Two-stage function Integrated bypass valve MB-ZRD(LE) B07

30 KW / 40 KVA POWERED by

55 KW / 70 KVA POWERED by

EP Series Electro-Pneumatic Preset Valve

Operating manual UPS - System

VariStroke II Electro hydraulic Actuator

Hydraulic Clamping Systems

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

General 4-stroke direct injected, turbocharged and aftercooled diesel engine

4/2 servo solenoid valves with on-board electronics (OBE), positive overlap and position feedback

VOLUMEC. Valve Position Indicator 02/04

SonoMeter 30 Energy Meters

FIXTURED APPLICATIONS

Uninterruptible Power System

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

80 KW / 100 KVA POWERED by

Simply intelligent: the new SintDOC diesel particulate filter. Continuous regeneration in top form

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

70 KW / 90 KVA POWERED by

Diesel Generator Set S3.8 Series Engine

Measuring capsule heat meter G54 / G55

Heating chamber with mechanical convection

PRELIMINARY. 92 kw. 16 t. Telescopic crawler crane. 24 m. Tier IV emission standards

Actual-position Feedback Unit. SISTO-SK-i. For Valves with Linear Actuators Stroke: 5-46 mm. Type Series Booklet

SAP E & C ADVANCED CUSTOMIZED ELECTRO PNEUMATIC TRAINER (FOR ITI) (PRODUCT CODE: SAP 20B-I)

60 KW / 75 KVA POWERED by

Industrial Diesel Generator Set KD3300-F 50 Hz Fuel Consumption Optimized

204 KW / 254 KVA POWERED by

Double solenoid valve Rp 3/8 - Rp 2 nominal diameters DMV-D/11 DMV-DLE/11

Compact hydraulic power unit Type BKA

Intelligent Mould Flow Monitoring

18 KW / 18 KVA POWERED by

Accessories for the measurement of tightening torque. Digital and electronics dynamometric wrenches

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

Section 5. Engine data. Engines for power generation. 12-series. Contents. Industrial & Marine Engines. Edition 2007:1

SonoMeter 30 Energy Meters

Technical data Demag D-SH SpeedHoist

Modular test system for diaphragm gas meters with critically operated Venturi nozzles

Diesel generator set B3.3 series engine 44 kva - 66 kva 50 Hz 40 kw - 60 kw 60 Hz

Heating chamber with mechanical convection

Servo solenoid valves with on-board electronics (OBE)

Industrial Diesel Generator Set KD2250-F 50 Hz Fuel Consumption Optimized

SPG-DIGI. Operating Instruction. Please read carefully before use!

MBC-300-SE MBC-700-SE MBC-1200-SE MBC-300-N MBC-700-N

LAUDA Integral. Process thermostats for professional external thermostating across a wide temperature range from -90 up to 320 C

2/2-way Globe Valve for media up to +180 C, DN

Voltage adjusting range % Transient voltage deviation(100% load sudden reduce) +20% Transient voltage deviation(load impact)

LiDAT. Data transmission and tracking system for crawler cranes, duty cycle crawler cranes and deep foundation machines GPS / GLONASS GSM / GPRS

original operating manual Operating manual Manual flow meter FMOGne Translation of the Item-No.: ,

57 KW / 71 KVA POWERED by

Driver Board User Manual

NEW. Large range of models, customizable performance output Flexible equipment options Easy and clear operation. LAUDA Variocool. Circulation chillers

1.4 SCT Temperature sensor

Immersion chillers E 01

640 KW / 800 KVA POWERED by

FUNCTION LINE HEATING AND DRYING OVENS

LAUDA Variocool. Numerous options, compact design, easy operation

The Right Solution for Every Application

Pocket Quick. Reference Guide. On the TOSHIBA. R410A - VRF Range of equipment. Addressing / Commissioning

SimpliPhi Power PHI Battery

OFFLINE SERIES GLOBAL STANDARD COOLER

PowerScale kva Technical Specifications

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

SO 61 to SO 126 Oil-free screw compressors (air or water cooled)

Transcription:

HDE 4000-DM Electrohydraulic high-pressure unit without pressure intensifier in modular design HDE 4000-D /DM 4000 bar direct power in smallest space.

Required type code Please only check one value per box. Max. pump pressure (pmax) 100 1000 bar / 100 MPa (14.500psi) 160 1600 bar / 160 MPa (23.200psi) 250 2500 bar / 250 MPa (36.250psi) 300 3000 bar / 300 MPa (43.500psi) 400 4000 bar / 400 MPa (58.000psi) Specify different pressures in bar Output ratio High-Pressure Pump 075 Output ca. 0,03 0,3 Litres/min. (pmax 4000 bar) 100 Output ca. 0,10 0,5 Litres/min. (pmax 4000 bar) 125 Output ca. 0,15 0,7 Litres/min. (pmax 4000 bar) 150 Output ca. 0,18 0,8 Litres/min. (pmax 4000 bar) 185 Output ca. 0,33 0,9 Litres/min. (pmax 3000 bar) Motor size 107 Drive motor 0.75 kw, 1 phase 230V 50Hz 111 Drive motor 1.1 kw, 1 phase 230V 50Hz 115 Drive motor 1.5 kw, 1 phase 230V 50Hz (Standard design) 120 Drive motor 2.0 kw, 1 phase 230V 50Hz 122 Drive motor 2.2 kw, 1 phase 230V 50Hz 315 Drive motor 1.5 kw, 3 phase 400V 50Hz 322 Drive motor 2.2 kw, 3 phase 400V 50Hz 330 Drive motor 3.0 kw, 3 phase 400V 50Hz Oil tank size 01 Filling and effective capacities: ca. 2 / 1 Litre 04 Filling and effective capacities: ca. 4.5 / 3.5 Litre 10 Filling and effective capacities: ca. 11 / 10 Litre XX Special oil tank according to customer s specification High-Pressure connections 01X 1 High-Pressure connection 02X 2 High-Pressure connections XXX Special manifold according to customer s specification Pressure in bar Motor size High-Pressure connection coupling C6 /... pcs Coupling Socket CVK16 (pmax 1600 bar) KA /... pcs Adapter M14 x 1,5 AG 60 DK (Screwed connection for high pressure hose, pmax 1600 bar) C2 /... pcs Coupling Socket CVK25-2 (pmax 2500 bar) MA /... pcs Adapter G 1/4" AG 60 DK (Screwed connection for high pressure hose, pmax 3000 bar) S4 /... pcs Coupling Socket SVK40 (pmax 4000 bar) XXX /... pcs Special connections according to customer s specification Language of pump labelling, software and documentation DE Monolingual - German GB Monolingual - English Other languages (enter ISO code)

Example of motor selection The HDE 4000-DM has an air-cooled motor. So the unit can be operated at the specified performance limits for short duration. If longer durations are required, or if the downtime between pressure applications is very short in duration, then the motor should be selected one size larger. For severe applications or operation in hot conditions an oil cooler unit is recommended. Determine the performance requirement in 4 steps 1. Determine maximum pressure (bar) 2. Determine maximum pumping capacity in L/min 1,0 1,0 0,8 0,6 0,4 185 150 125 100 75 0,8 0,6 0,4 185 150 125 100 75 0,2 0,2 0,0 0 1000 2000 3000 4000 Pressure in bar 0,0 0 1000 2000 3000 4000 Pressure in bar 3. Determine output ratio 4. Select motor size 1,0 0,8 0,6 0,4 0,2 185 150 125 100 75 Output ratio 0,0 0 1000 2000 3000 4000 Pressure in bar Motor size Special fabrications Special designs are optional. Please specify your requirements

Optional type code A variant can be selected in each block. If no selection is made then the standard design will be supplied as described. Electronic pressure monitoring The standard design is an electronic pressure transducer, 0-4000 bar. The actual pressure is indicated on the (remote) controller and is further processed by the control system. A second identical pressure transducer with reciprocal monitoring (redundant system). The two pressure transducers monitor each other. Any deviation is automatically detected without delay. This means that the intervals between calibration of the pressure transducers can be DM2 lengthened or eliminated entirely. For critical applications maximum operational safety is achieved. Requires type T controller. Oil level monitoring The standard design has optical monitoring with a transparent oil sight glass. S Optical monitoring with additional electrical shutdown when the oil level falls to minimum. Requires type T controller. Oil temperature monitoring The standard design does not include oil temperature monitoring. O Continuous oil temperature monitoring at the pump intake with indication on the pump display. Requires type T controller. Motor temperature monitoring The standard design provides automatic shutdown of the pump if the maximum motor winding temperature is exceeded. P Continuous monitoring of motor winding temperature with indication on the pump display. Requires type T controller. Oil cooling The standard design does not include a cooler unit, nor provision for the connection of a cooler. Quick-coupling system for coupling of a separate cooler unit V (the oil cooler unit can then be post ordered separately if required). K Separate, removable oil cooler unit with quick-connector coupling system to allow connection when necessary. Oil filter monitoring The standard design does not include oil filter monitoring. Continuous monitoring of the pressure upstream of the bypass filter with indication of dirty filter condition on the pump display. Requires K type T controller. Supplementary fan for drive motor The standard design has a fan wheel on the main motor shaft. The drive motor is fitted with a separately driven fan which also provides cooling even when the pump is shut down. P Requires type P motor temperature monitoring. Supplementary function module The supplementary function module provides for more complex hydraulic control using the HDE4000D unit, such as for hydraulic torque wrenches, GripLoc couplings or lifting applications. The function module is simply plugged as necessary into a multiple quick coupling system fitted to the pump. The standard design does not include a quick-coupling system. The use of a supplementary function module strictly requires a type T electronic controller (electronic controller with touch panel). Separate removable control module for the control of single and double-acting hydraulic torque wrenches up to 700 bar, including quickconnector coupling system for coupling as necessary (requires supplementary software module S or A). HS Separate removable control module for manual control of 2k GripLoc couplings up to 3000 bar, including quick-connector coupling system G2 for coupling when necessary. VX Only quick-coupling system (hydraulic/electric) for coupling of a separate control module.

Connector couplings for function module (when a function module is ordered) Function module for double-acting consumers are always fitted with quick-connector coupling socket and nipple (stroke an return stroke of doubleacting hydraulic tools or cylinders). If you have difficulty making your selection you can also specify the type of hydraulic tools or coupling systems to be used (please enter under special requirements). C5 Coupling Socket/-nipple C15 (pmax 1000 bar) C6 Coupling Socket/-nipple C16 (pmax 1600 bar) KA Adapter M14 x 1,5 AG 60 DK (Screwed connection for High-Pressure hose, pmax 1600 bar) G4 Connection Bores G1/4 (pmax 1600 bar, for installation of site couplings) C2305 Coupling Socket/-nipple C230-5 (pmax 700 bar) 14 Connection Bores 1/4 NPT (pmax 700 bar, for installation of site couplings) C2307 Coupling Socket/-nipple C230-7 (pmax 700 bar) 38 Connection Bores 3/8 NPT (pmax 700 bar, for installation of site couplings) C2 Coupling Socket CVK25-2 (pmax 2500 bar) MA Adapter G 1/4" AG 60 DK (Screwed connection for High-Pressure hose, pmax 3000 bar) S4 Coupling Socket SVK40 (pmax 4000 bar) XX Special connections according to customer s specification (any special design available, please enter under special requirements). Electronic control hardware The standard design includes a single electronic controller with 2 status lamps and electronic pressure indication. T Electronic controller with 5.7 touch panel and multi-row text display in the remote controller TSI (Tool Service Indicator) for monitoring of the service lifetime and maintenance indication for the individual components H (series with type T electronic controller) The following options can only be used in conjunction with the type T electronic controller Universal data transfer interfaces (hardware) UX UE 1x USB interface including software module for USB data storage and transmission (excluding PC software, interface according to SCHAAF standard) 1x USB and 1x Ethernet interface including software module for data storage (excluding PC software, interface according to SCHAAF standard) Elongation measuring device interfaces Elongation measuring device interfaces (hardware) for detection of elongation with integral elongation measuring device on bolt tensioners (necessary for assembly documentation). The standard design does not include elongation measuring device interfaces. For elongation measuring device interface type X (please specify type of elongation measuring device on the bolt tensioners)/ X /... pcs quantity of elongation measuring device interface operating simultaneously Software The standard design of the type T controller includes a basic software package for simple clamping operations (clamping cylinders). BM Software package with mounting documentation for simple tensioning operations (bolt tensioners, requires interface hardware UX or UE and elongation measuring device interfaces) MS STG software package with documentation for oil press fit units (master pump, requires UE interface hardware and elongation measuring device interfaces) SS STG software package with documentation for oil press fit units (slave pump, requires UE interface hardware) XX Special software package (internal sequential number) Supplementary software module S A Software module for manual control of hydraulic torque wrenches (for controlling the function module for type HS hydraulic torque wrenches) Software module for automatic control of hydraulic torque wrenches

Special requirements Please state further special wishes here:

Technical data Further versions on request Standard Special version Operating voltage: One-phase 230 V at 50 Hz Assortment by performance chart Nominal output: Hand control housing (remote control), connection cable: 230 V / 50 Hz Motor drive power: 1.5 kw Length: 5 metres Assortment by performance chart, max. motor drive power: 3.0 kw Length: metres, radio remote control Electricity supply cable with CEE plug: Length: 5 metres Length: metres Tank content: 2 litres If required by customer up to max. 10 litres Useful volume: 1 litre Special oil tank or only tank connection possible Hydraulic oil: HLP ISO VG 32 Requirement by customer Oil-level indicator: Inspection Glass Visual monitoring with electric deactivation Oil temperature monitoring: No monitoring Permanent gauging of oil temperature in intake area Motor temperature monitoring: No monitoring (performance-related) Measuring of motor winding temperature with automatic deactivation on max. value Oil cooling: No cooler (performance-related) Separately demountable oil cooler unit Quick coupling system Output: 0.05 1.0 l/min Assortment by performance chart Set-up: Modular compact unit, decomposable Requirements by customer Weight (filled with oil, without Approx. 2 x 20 kg distributor, without mounting parts): Length: 335 mm Width: 397 mm Height: 726 mm Distributor: According to type key Distributor of various versions Pressure gauge: Packaging: Electronic pressure monitoring Class 0.15 (standard design) Second pressure transducer (redundant system) Additional mechanical pressure gauge Transport box, simple wood Assembly box with hinged and swivel lock Version according to customer s wishes

SCHAAF GmbH & Co. KG Bruesseler Allee 22 41812 Erkelenz - Germany Telephone: +49-24 31-9 77 70-0 Fax: +49-24 31-9 77 70-77 E-Mail: info@schaaf-gmbh.com Internet: www.schaaf-gmbh.com PG22.hde4000dm.en_0911_indd_online Errors excepted. Data will change as developments occur. Only the latest state of the art design is decisive. Copyright as per standard ISO 16016.