Annex I Tested by (name + signature)...: Approved by (name + signature)...: Date of issue... : 22/11/2012. TUV RHEINLAND ITALIA S.r.l.

Similar documents
Testing Laboratory...: TÜV Rheinland Taiwan Ltd., Taichung Laboratory. Address...: 10F, No.219, Min Chuan Road, Taichung 403, Taiwan.

L7486R Cromwell Word Distribution 8 Inch Bench Grinder KOBE GB 200 December 2009 MD

ZHEJIANG MAXGE ELECTRIC TECHNOLOGY CO., LTD. Address... :

TEST REPORT ENVIRONMENTAL EN 60529:1991+A1:2000

Page 2 of 6. Summary of testing The clause 17 and clause 29 are considered and check on the appliance.

TEST REPORT IEC Degrees of protection provided by enclosures ( Partially for IP65 test )

Installation Couplers intended for permanent connection in fixed installation

Test Result No.1. Lead (Pb) % ND See comment if > % Cadmium (Cd) % ND Mercury (Hg) % ND

AS/NZS AS/NZS

Test Report issued under the responsibility of: Report Number... : CB131104C Date of issue... : Total number of pages...

VEM motors Thurm GmbH

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test Report issued under the responsibility of: Report Number...:

TEST REPORT IEC Luminaires Part 2: Particular requirements: Section Two Recessed luminaires

Page 3 of 32 Report No Summary of testing:

Test Report issued under the responsibility of: Report Reference No... : AS9-7 Date of issue... : Total number of pages...

ENEC LICENCE. Licence No. ENEC Page 1/3 Date of Issue

Amendment to Test Report

TEST REPORT IEC Connectors Safety requirements and tests

APPLICATION FOR IEC REPORT On Behalf of HENAN ESHOW ELECTRONIC COMMERCE CO., LTD Li-ion Battery Model: RT82

List of Attachments (including a total number of pages in each attachment):

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

TEST REPORT. IEC 62133: 2012 (Second Edition)

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

COVER PAGE FOR TEST REPORT

TEST REPORT IEC Switches for household and similar fixed-electrical installations Part 2-1: Particular requirements - Electronic switches

TEST REPORT IEC Safety of household and similar electrical appliances Part 2 : Particular requirements for fans

TEST REPORT. NO.: A001T Date: Jul 29, 2014 Page 1 of 7

Quick Engineering Facts Decimal Metric

TEST REPORT IEC Connectors Safety requirements and tests

Test report for mechanical switches according to IEC Switches for appliances Part 1: General requirements

Doc:TED 11(794)W Dec Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification

TEST REPORT DIN V VDE V

TEST REPORT IEC Low-voltage switchgear and control gear Part 7-4: Ancillary equipment PCB terminal blocks for copper conductors

TEST REPORT DIN V VDE V

34-SDMS-02 SPECIFICATIONS FOR

TEST REPORT IEC and/or EN Self-ballasted lamps for general lighting services Safety requirements

Doc:TED 11(794)W 1 September 2012 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification

TEST REPORT IEC Plugs and socket-outlets for household and similar purposes Part 1: General requirements

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Amendment to Test Report

TEST REPORT IEC 61427:2005 Secondary cells and batteries for photovoltaic energy systems (PVES) General requirements and methods of test

Intertek Testing Services Shanghai Address... : Building No.86, 1198 Qinzhou Road (North), Shanghai , China Applicant s name... : GlobTek, Inc.

Page 2 of 23 UNT150420C11

Installation Couplers intended for permanent connection in fixed installation

Test Report issued under the responsibility of:

The use of batteries in hazardous areas. 1. Type of batteries and technical evolution. March 2018

E/ECE/324/Rev.2/Add.104/Rev.2 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2

General Information Product Overview

APPLICATION FOR CONSTRUCTION PRODUCTS DIRECTIVE. On Behalf of Shenzhen Changen Industry Co.,Ltd. 2 interactive pins 5 color cylinder.

NEMA Standards Publication MG Safety Standard and Guide for Selection, Installation, and Use of Electric Motors and Generators

Town, DongGuan City, Guangdong Test specification :

BATTERY CHARGERS NO. 3

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

Approval mark PL HCR 1a A

Test Result No.1. Lead (Pb) % ND See comment if > Cadmium (Cd) % ND Mercury (Hg) % ND

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Impeller Replacement

FAQ S. Main Switchboard Design Criteria. ENGINEERED SOLUTIONS FOR ALL YOUR SWITCHBOARD NEEDS

TEST REPORT IEC Part 1: General requirements for basic safety and essential performance

TEST REPORT IEC60884_1C. Plugs and socket-outlets for household and similar purposes Part 1: General requirements

Page 2 of 39 Report No. CTI PA Testing location:

TEST REPORT PN-EN Light and lighting. Measurement and presentation of photometric data of lamps and luminaires

Swing Piston Compressors and Vacuum Pumps

Medium Voltage Induction Motors. 21-L Series New High Efficiency Design for High Capacity Applications 450 kw 18,500 kw (600 HP 25,000 HP)

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Test Report issued under the responsibility of:

TEST REPORT EN LED modules for general lighting Safety specifications

Page 3 of 34 Report No Part I

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

APPLICATION REPORT. On Behalf of SHENZHEN LANGHENG ELECTRONIC CO., LTD. Li-ion Battery. Model: ARB-L16-700

Medium and high pressure pumps

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

LIA Laboratories Limited

Powered. chain hoists. Electric and pneumatic. chain hoists

INSTRUCTIONS INSTALLATION OF NEMA-3R KIT FOR 43, 44 & 52 FRAME AF-6 DRIVES INTO WELDED ENCLOSURES

General information about motor protection

Guangzhou Vkan Certification and Testing Institute (CVC former GTIHEA)

Test Report No EEC12-02/MLM dated 29 MAR 2012

TEST REPORT IEC Part 2: Particular requirements: Section Thirteen d.c. or a.c. supplied electronic controlgear for LED modules

Installation manual. Intake system and ventilation. Industrial engines DC09, DC13, DC16 OC16. 01:02 Issue 10 en-gb. Scania CV AB 2018, Sweden

Test Report. Apricus Solar Co., Ltd. Multi-function differential controller

BUREAU OF INDIAN STANDARDS DRAFT FOR COMMENTS ONLY. (Not to be reproduced without the permission of BIS or used as an AMENDMENT)

SEM.Test Compliance Service Co., Ltd

TEST REPORT IEC LED modules for general lighting Safety specifications

No , Vers.1

TEST REPORT IEC Safety of Hand-Held Motor-Operated Electric Tools

TEST REPORT. Low Voltage Directive 2006/95/EC. Report No.: STDGZ L

SCC(10) LVD HANGZHOU GRANDIX ELECTRONICS CO., LTD. R NEW YOUTH PLAZA, NO.8 JIASHAN RD., HANGZHOU

013 : 2009 CEB SPECIFICATION MOULDED CASE CIRCUIT BREAKERS

E/ECE/324/Rev.2/Add.104/Rev.2/Amend.3 E/ECE/TRANS/505/Rev.2/Add.104/Rev.2/Amend.3

N , Vers. 0

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

CE Marking. Number of poles. Core Length. Frame size

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

TEST REPORT IEC Information technology equipment Safety Part 1: General requirements

Transcription:

TEST REORT Rotating electrical machines art 5: Degrees of protection provided by the integral design of rotating electrical machines (I code) Classification Report Reference No....: 28105442 002 Annex I Tested by (name + signature)...: S. Orecchia Approved by (name + signature)...: F. Ceriani Date of issue... : 22/11/2012 Testing Laboratory... : TUV RHEINLAND ITALIA S.r.l. Address... : Via Mattei, 3 20010 ogliano Milanese (MI) Italy Testing location / address... : As above Applicant s name... : Bronzoni Motori Elettrici srl Address... : Via G. Baisi 20/A 42030 Raniseto (RE) - Italy Test specification: Standard... : Test procedure...: Non-standard test method..: :2000+A1:2006 Test Report Form No.... : TRF Originator... : Master TRF... : Test item description...: Trade Mark...: Manufacturer...: Model and/or Type reference...: Rating(s)... : Electric motor. Bronzoni Motori Elettrici srl Bronzoni Motori Elettrici srl Via G. Baisi 20/A 42030 Raniseto (RE) - Italy GR 100 (model with 3.0 mm gasket) I 56 (for additional information see annex rating plate)

age 2 of 12 Copy of marking plate Summary of testing: The item under test fulfilled all the test Test item particulars : - Classification of installation and use : Fixed installation - Supply Connection : ossible test case verdicts: - test case does not apply to the test object... : - test object does meet the requirement... : (ass) - test object does not meet the requirement... : F(Fail) Testing... : Date of receipt of test item... : 19/10/2012 Date(s) of performance of tests... : 08/11/2012 General remarks: The test results presented in this report relate only to the object tested. This report shall not be reproduced, except in full, without the written approval of the Issuing testing laboratory. "(see Enclosure #)" refers to additional information appended to the report. "(see appended table)" refers to a table appended to the report. Throughout this report a comma (point) is used as the decimal separator. General product information: Tested complete one samples of three and single-phase induction motors without power cable connected and with 3.0 mm gasket under the metal cover of terminal box. No open hole was made in the terminal box and no insert any cable glands.

age 3 of 12 hotos: Dust Test I 5X

age 4 of 12 hotos: Water Test I X6

age 5 of 12 hotos.

age 6 of 12 hotos.

age 7 of 12 4 Degrees of protection First characteristic numeral 4.1 Indication of degree of protection The first characteristic numeral indicates the degree of protection provided by the enclosure to persons and to the parts of the machine inside the enclosure. Table 2 gives, in the third column, brief details of objects which will be excluded from the enclosure for each of the degrees of protection represented by the first characteristic numeral. The term excluded implies that a part of the body, a tool or a wire held by a person, either will not enter the machine or, if it enters, that adequate clearance will be maintained between it and the live parts or dangerous moving parts (smooth rotating shafts and the like are not considered dangerous). The third column of table 2 also indicates the minimum size of solid foreign objects which will be excluded. 4.2 Compliance to indicated degree of protection Compliance of an enclosure with an indicated degree of protection implies that the enclosure will also comply with all lower degrees of protection in table 2. In consequence, the tests establishing these lower degrees of protection are not required, except in case of doubt. 4.3 External fans The blades and spokes of fans external to the enclosure shall be protected against contact by means of guards complying with table 1. Table 1 Test requirements for guards rotection of machine For the test, the rotor shall be slowly rotated, for example by hand when possible. Smooth rotating shafts and similar parts are not considered dangerous. Finger test 4.4 Drain holes If the machine is provided with drain holes, the following shall apply: drain holes intended normally to be open on site shall be kept open during testing; drain holes intended normally to be closed on site shall be kept closed during testing; if machines with protection I3X or I4X are intended to be run with open drain holes, the drain holes may comply with protection I2X; if machines with protection I5X are intended to be run with open drain holes, the drain holes shall comply with protection I4X. No drain holes

age 8 of 12 Table 2 Degrees of protection indicated by the first characteristic numeral First Degree of protection characteristic numeral Brief description I5X 5 Degrees of protection Second characteristic numeral 5.1 The second characteristic numeral indicates the degree of protection provided by the enclosure with respect to harmful effects due to ingress of water. Table 3 gives, in the third column, details of the type of protection provided by the enclosure for IX6 each of the degrees of protection represented by the second characteristic numeral. An air-cooled open machine is weather-protected when its design reduces the ingress of rain, snow and airborne particles, under specified conditions, to an amount consistent with correct operation. This degree of protection is designated by the letter W placed after the second characteristic numeral. 5.2 For second characteristic numerals up to and including 6, compliance of an enclosure with an indicated degree of protection implies that the enclosure will also comply with all lower degrees of protection in table 3. In consequence, the tests establishing these lower degrees of protection are not required, except in case of doubt. For IX7 and IX8, it shall not be assumed that compliance of the enclosure implies that the enclosure will also comply with all lower degrees of protection in table 3 Table 3 Degrees of protection indicated by the second characteristic numeral Second Degree of protection characteristic numeral. Brief description 6 Marking It is recommended that the characteristic letters In the rating metal plate is and numerals be marked on the machine stamp I 56 preferably on the rating plate or, if this is not practicable, on the enclosure. When all parts of a machine do not have the same degree of protection, at least the designation of the lowest degree shall be shown, followed, if necessary, by the higher designation with clear reference to the part to which it applies.

age 9 of 12 NOTE Space limitations on the rating plate usually only allow the lowest I code to be marked. arts or components having a higher degree of protection should then be specified in the documentation and/or in the operating instructions. The lower degree of protection of: guards for external fans (as allowed in 4.3); drain holes (as allowed in 4.4); need not be specified on the rating plate or in the documentation. Where the mounting of the machine has an influence on the degree of protection, the intended mounting arrangements shall be indicated by the manufacturer on the rating plate or in the instructions for mounting. 7 General requirements for tests The tests specified in this standard are type tests. Test made on the complete They shall be carried out on standard product. products or models of them. Where this is not feasible, verification either by an alternative test or by examination of drawings shall be the subject of an agreement between manufacturer and user. Unless otherwise specified, the machine for each test shall be clean with all the parts in place and mounted in the manner stated by the manufacturer. In the case of both first and second characteristic numerals 1, 2, 3 and 4, a visual inspection may, in certain obvious cases, show that the intended degree of protection is obtained. In such cases, no test need be made. However, in case of doubt, tests shall be made as prescribed in clauses 8 and 9. 7.1 Adequate clearance For the purpose of the following test clauses in this standard, the term adequate clearance has the meaning given in 7.1.1 or 7.1.2. 7.1.1 Low-voltage machines (rated voltages not exceeding 1 000 V a.c. and 1 500 V d.c.) The test device (sphere, finger, wire, etc.) does not touch the live parts or moving parts other than non-dangerous parts such as smooth rotating shafts.

age 10 of 12 7.1.2 High-voltage machines (rated voltages exceeding 1 000 V a.c. and 1 500 V d.c.) When the test device is placed in the most unfavorable position, the machine shall be capable of withstanding the dielectric test applicable to the machine. This dielectric test requirement may be replaced by a specified clearance dimension in air which would ensure that this test would be satisfactory under the most unfavorable electrical field configuration. 8 Tests for first characteristic numeral Test and acceptance conditions for the first characteristic numeral are given in table 4. The dust test for numerals 5 and 6 shall be performed with the shaft stationary, provided that the difference in pressure between running and stationary (caused by fan effects) is lower than 2 ka. If the pressure difference is greater than 2 ka, the internal machine pressure during the dust test shall be depressed accordingly. Alternatively, the machine may be tested with the shaft rotating at rated speed. Table 4 Test and acceptance conditions for first characteristic numeral First characteristic numeral Test and acceptance conditions The test I 5X was made with air depression internal to the motor (see annex photos). No dust is present in the internal side of machine. 9 Tests for second characteristic numeral 9.1 Test conditions Test conditions for the second characteristic numeral are given in table 5. The test shall be conducted with fresh water. During the test, the moisture contained inside the enclosure may be partly condensed. The dew which may thus be deposited should not be mistaken for an ingress of water. For the purpose of the tests, the surface area of the machine shall be calculated with an accuracy of 10 %. When possible, the machine shall be run at rated speed. This can be achieved by mechanical means or by energization. If the machine is energized, adequate safety precautions shall be taken. Table 5 Test conditions for second characteristic numeral Second characteristic numeral Test conditions 9.2 Acceptance conditions After the test in accordance with table 5 has been carried out, the machine shall be inspected for ingress of water and subjected to the following verification and tests:

age 11 of 12 9.2.1 The amount of water which has entered the machine shall not be capable of interfering with its satisfactory operation. The windings and live parts not designed to operate when wet shall not be wet and no accumulation of water which could reach them shall occur inside the machine. It is, however, permissible for the blades of fans inside rotating machines to be wet and leakage along the shaft is allowable if provision is made for drainage of this water. 9.2.2 In the case of a test on a machine not running: a) the machine shall be operated under no-load conditions at rated voltage for 15 min, b) then be submitted to a withstand voltage test, the test voltage being 50 % of the test voltage for a new machine (but not less than 125 % of the rated voltage). In the case of a test on a running machine, only the withstand voltage test is made, in accordance with item b) above. The test is deemed satisfactory if these checks show no failure. No water has entered in the machine. 10 Requirements and tests for open weather-protected machines The degree of protection W is intended for aircooled open machines with open circuit cooling, that is, machines with cooling systems designated by IC0X to IC3X according to IEC 60034-6. Weather-protected machines shall be so designed that the ingress of rain, snow and airborne particles into the electrical parts is reduced. Other measures providing weather protection (such as encapsulated windings or total enclosure) are not designated by W. Machines with degree of protection W shall have ventilation passages constructed such that: a) at both intake and discharge, high-velocity air and airborne particles are prevented from entering the internal passages leading directly to the electrical parts of the machine; b) the air intake path, by baffling or use of separate housings, provides at least three abrupt changes in the direction of the air intake, each of which is at least 90 ; c) the air intake path provides an area of average velocity not exceeding 3 m/s, enabling any particles to settle. Removable or otherwise easy to clean filters or any other arrangement for the separation of particles may be provided instead of a settling chamber.

age 12 of 12 The protection of the machine against contact, foreign objects and water shall comply with the conditions and tests specified for the stated degree of protection. The design of the terminal box shall ensure a degree of protection of at least I54. If necessary, arrangements to provide protection against icing, moisture, corrosion or other abnormal conditions shall be made by agreement (e.g. by using anti-condensation heating). For the verification of weather protection W, a study of drawings is generally sufficient. END OF TEST REORT