Case No. 5 Sequential Motor Dynamic Acceleration Simulation ETAP TS V&V Case Number TCS-TS-181

Similar documents
Islanding of 24-bus IEEE Reliability Test System

Islanding of 24-bus IEEE Reliability Test System

The Effect Of Distributed Generation On Voltage Profile and Electrical Power Losses Muhammad Waqas 1, Zmarrak Wali Khan 2

Journal of American Science 2015;11(11) Integration of wind Power Plant on Electrical grid based on PSS/E

COMPARISON OF DIFFERENT SOFTWARE PACKAGES IN POWER FLOW AND SHORT-CIRCUIT SIMULATION STUDIES. A Project

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

Intentional Islanding Operation to Improve the Service Reliability of Thailand Electric Power System

Grid Stability Analysis for High Penetration Solar Photovoltaics

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

FAULT ANALYSIS OF AN ISLANDED MICRO-GRID WITH DOUBLY FED INDUCTION GENERATOR BASED WIND TURBINE

Impact of Islanding and Resynchroniza?on on Distribu?on Systems

Power Conditioning of Microgrids and Co-Generation Systems

Performance Analysis of Transient Stability on a Power System Network

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

GTG MW GTG MW STG 2 36 MW CB11 CB9 GEN TRAFO-4. GEN TRAFO-5 50 MVA 11/34.5 kv %Z. GEN TRAFO-2 50 MVA 11/34.5 kv 15.

Transient Stability Improvement of Squirrel Cage Induction Wind Turbine Generator using Plugging Mode

Electrical grid stability with high wind energy penetration

Targeted Application of STATCOM Technology in the Distribution Zone

Motor Protection Fundamentals. Motor Protection - Agenda

Power Systems Trainer

Voltage Sag Mitigation in IEEE 6 Bus System by using STATCOM and UPFC

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

CONTROL AND PERFORMANCE OF A DOUBLY-FED INDUCTION MACHINE FOR WIND TURBINE SYSTEMS

Brochure. Wind turbine generators Reliable technology for all turbine applications

Dynamic Study of Bonaire Island Power System: Model Validation and Project Experience

DETOUR GOLD CORPORATION SYSTEM IMPACT ASSESSMENT FOR DETOUR LAKE PROJECT

ENHANCEMENT OF TRANSIENT STABILITY OF SMART GRID

Unit-II Synchronous Motor

EXPERIMENT 2 THREE PHASE INDUCTION MOTOR, PART 1

IEEE T&D FACTS Panel Session Part II (08TD0140) Wednesday, April 23, 2008

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

GENERATOR INTERCONNECTION APPLICATION

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

PV Grid Integration Research in the U.S.

Generating Unit Model Validation Policy

OPTIMUM ALLOCATION OF DISTRIBUTED GENERATION BY LOAD FLOW ANALYSIS METHOD: A CASE STUDY

Transient Stability Analysis with PowerWorld Simulator

ECEN 667 Power System Stability Lecture 19: Load Models

Anupam *1, Prof. S.U Kulkarni 2 1 ABSTRACT I. INTRODUCTION II. MODELLING OF WIND SPEED

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

(by authors Jouko Niiranen, Slavomir Seman, Jari-Pekka Matsinen, Reijo Virtanen, and Antti Vilhunen)

EE 456 Design Project

NEWFOUNDLAND AND LABRADOR HYDRO GULL ISLAND TO SOLDIERS POND HVDC INTERCONNECTION DC SYSTEM STUDIES VOLUME 1

SPIDER Modeling Sub-Group DER Modeling, CAISO Experience

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Standby Power Systems

Renewable and Distributed Energy Resource Technologies

Transient Stability Analysis of IEEE 9 Bus System Using Power World Simulator

A Case Study on Aggregate Load Modeling in Transient Stability Studies

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

DYNAMIC BEHAVIOUR OF SINGLE-PHASE INDUCTION GENERATORS DURING DISCONNECTION AND RECONNECTION TO THE GRID

The North Carolina solar experience: high penetration of utility-scale DER on the distribution system

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX TRANSMISSION AND FACILITIES STUDY. Short Circuit Analysis

EE 742 Chap. 7: Wind Power Generation. Y. Baghzouz Fall 2011

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

Cascading Fault in AC/DC Hybrid Power Grid Xinzhou Dong

ECE 5671/6671 Lab 5 Squirrel-Cage Induction Generator (SCIG)

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

Experiences with Wind Power Plants with Low SCR

Power System Stability Analysis on System Connected to Wind Power Generation with Solid State Fault Current Limiter

Spec Information. Reactances Per Unit Ohms

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

Development of Electrical Power System Simulator.

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Short Circuit Analysis with New Generation Proposed by XXXXXXXXXXXXXXXXXXXXXX Pursuant to a Transmission and Facilities Study

Electric Machines CHARLES A. GROSS. Aubum University Auburn, Alabama, U.S.A. LßP) CRC Press Vv* / Taylor & Francis Croup. Boca Raton London New York

OPENDSS SIMULATIONS ON KAUPINRINNE LV-NETWORK

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

GRID CONNECTION ISSUES FOR DISTRIBUTED GENERATION REVIEW & STANDARDS

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

DC Microgrids and Distribution Systems for Residences

Impact of Photovoltaic Power Plant on the Transient Stability Compared With Synchronous Generator.

SIGENTICS HV Series S-modyn

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Frequency Control of Isolated Network with Wind and Diesel Generators by Using Frequency Regulator

Synchronous Generators I. Spring 2013

GENERATOR DATA MAY 10, 2018

This webinar brought to you by the Relion product family Advanced protection and control IEDs from ABB

Electric Utility Contact Information Indiana Michigan Power

Synchronous Motor Drives

EPE97 OPTIMIZED DESIGN OF VARIABLE-SPEED DRIVES BASED ON NUMERICAL SIMULATION

J.-J.Simond*, A.Sapin**, B.Kawkabani*, D.Schafer***, M.Tu Xuan*, B.Willy***

Composite Load Model Sensitivity Study

EL PASO ELECTRIC COMPANY SHORT CIRCUIT ANALYSIS FOR XXX S PROPOSED GENERATION INTERCONNECTION

Computer Aided Transient Stability Analysis

GENERATOR DATA SEPTEMBER 29, 2015

Evaluation of the Performance of Back-to-Back HVDC Converter and Variable Frequency Transformer for Power Flow Control in a Weak Interconnection

CHAPTER 4 : RESISTANCE TO PROGRESS OF A VEHICLE - MEASUREMENT METHOD ON THE ROAD - SIMULATION ON A CHASSIS DYNAMOMETER

Power Technology Issue 104

Generator Interconnection System Impact Study For

POWER QUALITY ISSUES IN WIND DIESEL HYBRID POWER GENERATION SYSTEMS

Real-Time Simulation of A Modular Multilevel Converter Based Hybrid Energy Storage System

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

Simulation and Analysis of a DFIG Wind Energy Conversion System with Genetic Fuzzy Controller

Synchronous Generators I. EE 340 Spring 2011

Experiences in a Motor Protection Retrofit

Electric Power System Under-Voltage Load Shedding Protection Can Become a Trap

Transcription:

ETAP Transient Stability Validation Cases and Comparison Results Case No. 5 Sequential Motor Dynamic Acceleration Simulation ETAP TS V&V Case Number TCS-TS-181 Comparison with PTI PSS/E Simulation Results Highlights: Comparison of simulation results between the ETAP Transient Stability simulation results and PTI PSS/E program Sequential motor dynamic acceleration study involving six motors An islanded system with no power grid support ETAP built-in salient-pole subtransient synchronous generator model ETAP built-in IEEE ST2 excitation/avr model ETAP User-Defined Dynamic Model (UDM) for Woodward Diesel engine/governor model ETAP built-in double-cage induction machine model ETAP Transient Stability program simulation results compared to the PSS/E results Comparison includes generator real, reactive and mechanical power, exciter voltage, generator speed, and induction motor terminal voltage and slip Nearly identical results from ETAP and PSS/E 1. System Description The system includes a generator and a group of induction motors as shown in Figure 1. The diesel unit generator is rated in 1.87 MW, and modeled in ETAP with Subtransient salient-pole type. Exciter/AVR is modeled with ETAP built-in IEEE Standard ST2 type, and Turbine/Governor is modeled with ETAP User-Defined Dynamic Model (UDM) Woodward Diesel type, shown in Figure 2. The induction motors ratings are ranged from 225 to 400 HP, and dynamically modeled with ETAP double-cage integrated bars type. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 1 of 8

1.87 MW DG31 CB20 BUS 2A 0.48 kv BUS 3A 0.48 kv CB6 CB5 CB1 CB7 CB8 CB10 CB9 Z8 Z7 Z5 Z9 Z10 Z11 Z6 MCC 36C 0.48 kv SIP32 CRF32 RHRP31 0.46 kv CRF34 SWP35 AFWP31 Load3 112 kva SIP 32 400 HP CRF 32 225 HP RHRP 31 400 HP CRF 34 225 HP SWP 35 350 HP AFWP 31 400 HP Fig. 1. Sequence Motor Dynamic Acceleration Simulation Study System Fig. 2. ETAP UDM Woodward Diesel Turbine/Governor Model 2. Simulation Events The simulation events on this system are scheduled to start-up one-by-one all six induction motors with 5 second intervals between each starting. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 2 of 8

3. Simulation Result Comparisons with PTI PSS/E In this study, the generator and motor simulation results, including generator real, reactive and mechanical power, generator speed deviation, exciter voltage, motor voltages and slips are compared with the results by PTI PSS/E. The following plots (Figures 3-10) show the result comparisons between ETAP and PSS/E. Fig. 3. Generator Real, Reactive, and Mechanical Power by PSS/E Fig. 4-1. Generator Real, Reactive, and Mechanical Power by ETAP Simulation results for generator real and reactive power outputs and mechanical power input in Figures 3 and 4-1 show a very close agreement between the two simulations in terms of their peak values, final values, rising time, and overall Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 3 of 8

response shapes. Note that the PSS/E results show a spike-like motor inrush in the generator reactive power curve at the beginning of each motor acceleration, which are not present in the ETAP results. In the ETAP simulation results, these motor inrush values are present for each individual motor reactive power demand (Figure 4-2), but not for the generator since the overall demand on the generator includes the combined effects of the starting motor inrush and the normal reactive power demand of all of the previously started motors, which are running. Fig. 4-2. Motor Reactive Power by ETAP Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 4 of 8

Fig. 5. Generator Exciter Voltage and Speed by PSS/E Fig. 6. Generator Exciter Voltage and Speed by ETAP Figures 5 and 6 show a comparison for generator exciter voltage and speed responses. No significant difference is noticed between the two simulation results. It is pointed out that the initial load flow condition is not stable in the PSS/E simulation results. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 5 of 8

Fig. 7. Induction Motor Terminal Voltages by PSS/E Fig. 8. Induction Motor Terminal Voltages by ETAP The motor terminal voltage responses for all six accelerating motor buses display the same patterns and values in both simulation, shown in Figures 7 and 8. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 6 of 8

Fig. 9. Induction Motor Speed Slips by PSS/E Fig. 10. Induction Motor Speed Slips by ETAP The motor slip response curve comparison in Figures 9 and 10 shows the motor acceleration time and final slips for all six accelerating motors are almost identical. Note that the motor slip is defined here as (ωmtr - ωsys)/ ωsys, which is normally defined as (ωsys - ωmtr)/ ωsys. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 7 of 8

4. Conclusions A comprehensive comparison between ETAP and PSS/E results clearly show that both programs provide almost identical results. Reference: ETAP Transient Stability V&V Documents, Test Case Number TCS-TS-181, 2005. Copyright 2005 Operation Technology, Inc. All Rights Reserved. Page 8 of 8