Features: Concealed installation. Compact design. Available in electric, LPHW or ambient.

Similar documents
Features: Available in horizontal and vertical units

Highline 260i EC Waterside Fan Coil Unit

IDENTIFICATION ACCESSORIES DESCRIPTION

Ocelot vertical fan coil unit

Hydropac. Waterside Control Fan Coil Units For Horizontal and Vertical Applications. June Hydropac. Features

Chassis Access Fans Motors Speed Control Coils The Condensate Tray Insulation Spigots Controls Enclosure Control Valves Filters Rev A

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSCOIL. Centrifugal fan coil units

ULTRA LOW ENERGY. VHR Void Series W/I/s TOTAL SFP Typical. Made in the UK. VHR Void Mounted Heat Recovery Units VHR PERFORMANCE OVERVIEW:

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

Chiller Close Control Water terminals SYSCASSETTE. Water cassette units

INHERENTLY QUIET AND POWERFUL 180 MM DEEP SLIMLINE HORIZONTAL WATERSIDE CONTROL IN CEILING

INSTALLATION, OPERATION & MAINTENANCE INSTRATIONS

Vent-Axia Roof Units Range Energy Recovery Ventilation (ERV) Range

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Residential comfort unit OperatiOn 2 models. new builds or existing properties. 5 operating modes COnfOrmity COmpOnents

Systempac. Fan Coil Unit / Acoustic Flex / Diffuser System Package. Systempac. January Features and Design Guide

The World Leading Air-conditioning Company

Sapphire Horizontal Waterside Control Fan Coil Units

CENTRIFUGAL FAN COIL UNIT VCE

PVHRU Max Quiet. Engineering Solutions. Packaged Void Heat Reclaim Unit. Acoustic Testing Laboratory College of Science & Technology

AHTW Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

Versatility. Features. By installing the SILENT MV, you will never experience the disturbance of noisy ventilation again. Benefits

Heat exchanger. Type WL. For the reheating of airflows in circular ducting PD WL 1. 03/2017 DE/en

BRIZA EC 12 HYBRID. World s slimmest fan coil HEATING AND COOLING

Innovative Engineering. Catalogue. Condenser. ECU, ECV and ECW Industrial Condenser Series. Technical Brochure

Warning. Document ref: A October 2015

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

COMFORT AIR CURTAIN. SensAir

AHPHX Compact. Heat Recovery Air Handling Unit. BIM & REVIT Engineering Solutions. Acoustic Testing Laboratory College of Science & Technology

SILENT MV Ultra Quiet In-line Fans

AHN 064 to 304 EHN/CHN 064 to 304


Engineering Data Manual. New : available with EC motor. High Static Pressure Ductable Fan Coil Unit. Models 07 to to 4650 m 3 /h

AIR VENT T E C H N O L O G Y. infinity. energy efficient - environmentally friendly - economical EC MOTORS - direct drive - CuSTOM built ErP Compliant

COMFORT AIR CURTAIN. SensAir

BRIZA 22 HYBRID HEATING & COOLING

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

COMFORT AIR CURTAIN. SensAir

ITEC High Efficiency EC Twin Fan for convenient fitting and full control. Casing constructed from 1.6mm Galvanised sheet steel

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CLIMA CANAL HYBRID HEATING AND COOLING CLIMA CANAL. Compact floor recessed fancoil unit HEATING

PRECISION UK Ltd DUPLEX AGSS PLANT

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Sentry. Door Curtain. Energy efficient EC motors Cased and concealed models LPHW and electric heating Comprehensive range of controls

LOW STATIC FAN COIL UNITS District Cooling Chilled Water Application

HTC. Air cooled Condensers. Capacities kw. Ripple Fin tubing Floating coil block suspension

TECHNICAL MANUAL ESTRO BLDC ESTRO BLDC FAN COILS - BRUSHLESS TECHNOLOGY. 1.5 kw kw

ECONOPLATE BV SERIES HOT WATER SERVICE PACKAGED HEAT EXCHANGERS WITH THERMAL STORES

ENR Incorporating

Standard: for ceiling grid dimensions 1200 x 1200 mm, 1200 x 900 mm, 1200 x 600 mm. Other dimensions are available on demand.

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

42CET/ 42CED Series Chilled Water Fan Coil Unit Furred-in Ceiling Model 300 to 1400 cfm Electric heater option

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Sabre Plate Mounted Sickle Fans (VSP)

ACR RECESSED AIRCURTAIN ELECTRICALLY HEATED, AMBIENT & LPHW INSTALLATION AND OPERATING MANUAL

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Air-Cooled Liquid Chiller with integrated hydraulic module

Fan coil units. HFCE, HFXE, VFCE, VFXE series Sizes 03 to to 3400 m3/h UNT-PRC007-E4

VAV TERMINAL BOXES TYPE: BA BT

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK

HIGH EFFICIENCY ROTARY WHEEL - HELPING TO SAVE ENERGY AND REDUCE CARBON EMISSIONS.

BOX BLB Centrifugal Box Fan

MAJOR 2 NCH. Ductable units. High pressure and high capacity ductable units RANGE NCH Y NCH NCH I COADIS COMBI. Motor optional

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

UTA STANDARD. Ductable units. Range. Air handling unit with high available static pressure. NEW Eco-Design Filter. V3000 control Fresh air management

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Trench Heating/Cooling. Katherm HK. Tested acc. to: BS EN 16430

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

HEATING & COOLING COIL PRODUCTS AIR COOLED CONDENSERS

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

Sentinel D-Box Single Fan

ALC-PRM-VFC. Ceiling Mounted Photocell. Product Guide. Overview. Features

ifan Copford Box Range

AIR CURTAIN DESIGNER C RANGE Horizontal and Vertical

something new in the air Technical Bulletin

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

LINEAR BAR GRILLES T SERIES. Quality and e!ciency without compromise

Aerocourse Fan Assisted Trench Heating

Ductable Modular Fan Coil Unit VPX. Technical Brochure TM VPX-W.2GB Date : May 2004 Supersedes : TM VPX-W.1GB/08.03

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Technical Catalogue. Cassette Fan Coils Climmy Comfort 3

Low Air Process Room. Chiller Series. EPC - High & Medium Temperature Application Capacity: 2.2kW to 19.2kW

FCVC Series VERTICAL FAN COILS

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

Homepage > Products > Chilled Beams and Multi Service Chilled Beams > Active Chilled Beams > SMART BEAM > Type SMART BEAM SMART BEAM

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

PHV V NT VERTICAL AIR CURTAINS INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Chilled Water Vertical Fan Coils

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

@Perkins. Technical Data Series 1103C-33TG3. Performance. Basic technical data. Test conditions. Total weight (fan to flywheel)) Sound level

@Perkins. Technical Data Series 1104C-44G2. 52, rev/min. Electropak. Basic technical data. Performance

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

NEW Slimpak EC Box Fan (SLPT EC)

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

Transcription:

Features: Concealed installation. Compact design. Available in electric, LPHW or ambient. Grille can be supplied in a large range of colours. Energy saving controls option available.

Application The Diffusion Eclipse recessed air curtain has been designed for a vertical concealed application where the client does not want see a unit within area. The unit shall be vertical mounted within a recess/ bulkhead construction thus only showing the discharge & return air grilles. The unit can be supplied in water heating, electric heating or ambient. The unit comes in standard lengths of 1700, 2100, 2600 & 3000mm, however we do offer a bespoke service allowing us to adjust the unit size to fit any building application. Chassis The chassis shall be manufactured from heavy gauge galvanised mild steel sheet, with burr free edges and a natural finish, formed and strengthened to provide a rigid and distortion free construction. Maintenance access shall be via the removable return air filter. Fans assembly The unit shall be fitted with a high output permanent spilt phase capacitor, continuously rated and complete with a built in thermal overload protection, complying with BS 2048 1961 part 1 and BS5000. The fans shall be double inlet, double width centrifugal type dynamically balanced in two planes according to DIN standards BS ISO 1940. The motors shall be insulated to BS 2757 (class B). Heat Exchanger (LPHW Version) Heat exchanger matrixes shall be manufactured from solid drawn copper tubes; mechanically expanded into accurately pre-formed collars in rippled plate type aluminium fins. Multi circuit designs shall be incorporated ensuring maximum thermal performance efficiency, headers unifying the circuits shall terminate in plain tail connections on 40mm centres. Heating exchanger headers shall incorporate manually operated key pattern air vents and drains. Heat exchangers shall be suitable for operating at system pressures up to 12 bar, tested to 30 bar dry air / nitrogen at manufacture, and subsequently leak tested again when fitted with valve sets at our works. Electric Elements Electric heating elements shall be manufactured from 8mm fully sheathed stainless steel rods, with spiral fin on a 4mm pitch. A manual re-set high temperature cut-out shall be fitted in accordance with standard safety requirements. The element construction shall comply with BS7351 1990. Filters Fitted as standard the Diffusion eco filter shall be made of a fine woven mesh manufactured from galvanised steel wire, welded to a rigid galvanised steel support frame; retained on the unit via thumb screws. The eco filter shall be capable of being vacuum cleaned whilst fitted to the unit and removable for cleaning elsewhere if required. Quality testing When fully assembled each unit shall be subjected to thorough mechanical examination, be run tested and function tested where possible; and need to have passed a series of electrical compliance checks prior to being QC approved in accordance with our BS EN ISO 9001:2000 quality standards; ready for packing and dispatch. Function Tests Each unit shall be function tested at our factory to ensure correct operation. All electrical components shall be tested to ensure each unit and its associated wiring complies with the 17th edition of IEE. The unit shall be manufactured in accordance with BS EN ISO 9001:2000 quality standards. Controls Electric version: Supplied with a remote control plate housing on/ off, speed high/low, heat off, low and high, finished in satin chrome as standard, suitable for fitting onto a standard two gang, recessed or surface mount, electrical back box. The unit can be used in ambient mode, by using the fans only setting. LPHW version: Supplied with a remote control plate housing 4 speeds/ off, finished in satin chrome as standard, suitable for fitting onto a standard two gang, recessed or surface mount, electrical back box. Energy Controls (Optional) Our award winning energy saving controls system offers state of the art technology that allows the end user closer control of the equipment. The controls function by using an off coil sensor which will restrict the leaving air temperature (solid state relays on electric & 2 or 3 port valves on LPHW) to a set value (40ºC as standard but this is adjustable). Return and outside temperature sensors can be added into the system making it fully automatic, thus not needing manual changeover of summer/winter operation. The controller also offers as standard inputs for remote BMS monitoring, common fault signal, BMS on/off, BMS summer/winter, BMS speed control, occupancy sensor/door switch and high heat temperature trip. The LCD remote control plate houses speeds, on/off control, plus fault indications. Optional Extras Low water temperature cut out: Provides automatic shutdown of the fan/ motor when boilers have been switched off (standard controls only). Summer/Winter switch (manual): Used in conjunction with the room thermostat and/or low water temperature cut out, this will allow the fan only to run for air movement (standard controls only). Remote thermostat: Available in adjustable or tamperproof (standard & Energy saving controls). BMS interface relay: 24vac relay and base (standard controls only). Fault indication relay: current sensitive relay to indicate fault alarm from unit (standard controls only). 2 or 3 port valves (standard controls only). Return air sensor: Mounted integral to the unit (energy controls only). Outside temperature sensor: To detect outside conditions (energy controls only). PIR Sensor: To offer automatic on/off control of the unit (energy controls only). BMS Fault Signal Relay: 12VDC relay and base to indicate fault alarm from unit (energy controls only). *Please note that if our energy controller is utilized on our electric units, the above noise levels can be significantly reduced, as the air volumes can be lowered.

Performance Details Eclipse LPHW Speed Setting / Airflow / db(a) / Guide NR Heating Performance Data A Heating Performance Data B Electrical & Mechanical Data Model Reference 1700W 1700W 2100W 2100W 2600W 2600W 3000W 3000W Fan Speed Setting Air Volume Noise level at 3 meters Individual Unit Acoustic Guide Heating Output LPHW Flow & Return Temperatures C Flow Rate Hydraulic Pressure Drop Heating Output L/M/H/B l/s db(a) NR kwatts F / R l/s kpa kwatts F / R l/s kpa V/ph/Hz Watts Amps Amps W/l/s kg LPHW Flow & Return Temperatures C Flow Rate Hydraulic Pressure Drop Low 280 33 40 8.6 82/71 0.19 3.1 7.0 80/60 0.09 0.7 Medium 360 41 47 10.3 82/71 0.23 4.2 8.5 80/60 0.10 1.0 200 2.7 0.9 0.56 460 47 52 12.1 82/71 0.27 5.8 9.9 80/60 0.12 1.3 298 4.0 1.3 0.65 Electrical Supply Motor Power Maximum Start Run Current Operating / Full Load Current Specific Fan Power 124 1.6 0.5 0.44 Boost 600 52 56 14.3 82/71 0.32 7.9 11.7 80/60 0.14 1.8 454 6.0 2.0 0.76 Low 280 33 40 5.6 70/50 0.07 0.4 2.5 60/40 0.03 0.1 124 1.6 0.5 0.44 Medium 360 41 47 6.9 70/50 0.08 0.6 2.8 60/40 0.03 0.2 200 2.7 0.9 0.56 460 47 52 8.4 70/50 0.10 0.9 3.0 60/40 0.04 0.2 298 4.0 1.3 0.65 Boost 600 52 56 10.0 70/50 0.12 1.2 3.3 60/40 0.04 0.2 454 6.0 2.0 0.76 Low 400 33 40 12.5 82/71 0.28 7.5 10.5 80/60 0.13 1.9 175 2.3 0.8 0.44 Medium 550 41 47 15.6 82/71 0.35 11.4 13.1 80/60 0.16 2.8 293 4.0 1.3 0.53 710 47 52 18.3 82/71 0.41 15.3 15.3 80/60 0.19 3.7 460 6.1 2.0 0.65 Boost 875 52 56 20.9 82/71 0.46 20.0 17.4 80/60 0.21 4.7 652 8.5 2.8 0.75 Low 400 33 40 9.1 70/50 0.11 1.2 3.6 60/40 0.04 0.3 175 2.3 0.8 0.44 Medium 550 41 47 11.6 70/50 0.14 1.9 6.4 60/40 0.08 0.7 293 4.0 1.3 0.53 710 47 52 13.6 70/50 0.17 2.5 8.1 60/40 0.10 1.0 460 6.1 2.0 0.65 Boost 875 52 56 15.5 70/50 0.19 3.2 9.5 60/40 0.12 1.3 652 8.5 2.8 0.75 Low 475 33 39 15.1 82/71 0.34 12.7 12.8 80/60 0.16 3.0 Medium 660 42 47 19.0 82/71 0.42 18.5 16.1 80/60 0.20 4.7 352 4.7 1.6 0.53 850 48 53.3 82/71 0.50 25.4 18.9 80/60 0.23 6.3 552 7.3 2.4 0.65 Boost 1050 53 57 25.5 82/71 0.57 32.0 21.5 80/60 0.26 7.9 783 10.2 3.4 0.75 Low 475 33 39 12.7 70/50 0.15 1.9 7.5 60/40 0.09 0.7 Medium 660 42 47 16.1 70/50 0.20 2.8 10.2 60/40 0.12 1.2 352 4.7 1.6 0.53 850 48 53 18.9 70/50 0.23 3.8 12.3 60/40 0.15 1.7 552 7.3 2.4 0.65 Boost 1050 53 57 21.7 70/50 0.26 4.9 14.3 60/40 0.17 2.4 783 10.2 3.4 0.75 Low 475 33 39 16.4 82/71 0.37 16.8 14.2 80/60 0.17 4.4 Medium 660 42 47 20.6 82/71 0.46 25.8 17.6 80/60 0. 6.6 352 4.7 1.6 0.53 850 48 53 24.6 82/71 0.55 36.0 21.1 80/60 0.26 9.2 552 7.3 2.4 0.65 Boost 1050 53 57 26.2 82/71 0.58 40.0 24.0 80/60 0.29 11.2 783 10.2 3.4 0.75 Low 475 33 39 14.0 70/50 0.17 2.6 9.1 60/40 0.11 1.2 Medium 660 42 47 17.6 70/50 0.21 4.0 11.8 60/40 0.14 1.9 352 4.7 1.6 0.53 850 48 53 21.2 70/50 0.26 5.6 14.4 60/40 0.17 2.8 552 7.3 2.4 0.65 Boost 1050 53 57 24.3 70/50 0.30 7.1 16.7 60/40 0.20 3.6 783 10.2 3.4 0.75 Unit Weight 91 91 106 106 127 127 142 142

Eclipse ELECTRIC Speed Setting / Airflow / db(a) / Guide NR Electrical & Mechanical Data Model Reference 1700E 2100E 2600E 3000E Fan Speed Setting Air Volume Noise level at 3 meters Individual Unit Acoustic Guide Heating Output Electrical Supply Motor Power Maximum Start Run Current Fans Only / Full Load Current Heating Element / Full Load Current per Phase L/M/H/B l/s db(a) NR kwatts V/ph/Hz Watts Amps Amps Amps W/l/s kg Low 280 33 40 12 Specific Fan Power 124 1.6 0.5 17.2 0.44 Medium 360 41 47 12 200 2.7 0.9 17.6 0.56 460 47 52 12 298 4.0 1.3 18.0 0.65 Boost 600 52 56 12 454 6.0 2.0 18.7 0.76 Low 400 33 40 18 175 2.3 0.8 25.9 0.44 Medium 550 41 47 18 293 4.0 1.3 26.4 0.53 710 47 52 18 460 6.1 2.0 27.1 0.65 Boost 875 52 56 18 652 8.5 2.8 27.9 0.75 Low 475 33 39 18 210 2.7 0.9 26.0 0.44 Medium 660 42 47 18 352 4.7 1.6 26.7 0.53 850 48 53 18 552 7.3 2.4 27.5 0.65 Boost 1050 53 57 18 783 10.2 3.4 28.5 0.75 Low 475 33 39 24 210 2.7 0.9 34.3 0.44 Medium 660 42 47 24 352 4.7 1.6 35.0 0.53 850 48 53 24 552 7.3 2.4 35.8 0.65 Boost 1050 53 57 24 783 10.2 3.4 36.8 0.75 Unit Weight 91 106 127 142 db(a) Figure Qualification The db(a) figures quoted are calculated by applying the A-weighting adjustment to the sound power (LW) levels; at frequencies from 63Hz to 8kHz which have been determined by measurement in reverberant rooms, at each speed setting. The resultant figures are then adjusted for a distance of 3 meters to the listener:- db(a) at 3 meters.. NR Guide Qualification Calculations detailed in the CIBSE Guide for Sound Control are used to model the combined Inlet (and Case Radiated where applicable) sound power levels and Discharge sound power levels for each unit and speed setting; providing a Guide NR rating for the units when installed in a typical manner. Room size based on a heating load of: Room acoustic characteristics: Distance to listener: 100Watts per square metre. Medium Live. 1.5 metres. Please note that our NR figure should be considered as a guide only. There are many factors which influence the actual resultant NR level within a given space; thus we would recommend that for a more accurate prediction of the resultant NR level an independent acoustic specialist be employed. Please note with standard controls a two speed remote switch plate will be supplied and this will be wired to & Boost speeds. Should you require the lower noise ratings of Low or Medium speed then the optional energy saving controls will need to be purchased. Coils Tails: mm plain copper

Eclipse - LPHW, Electric and Ambient Recessed ECLIPSE Air Curtain General Arrangement Details LPHW, ELECTRIC AND AMBIENT RECESSED AIR CURTAIN GENERAL ARRANGEMENT DETAILS REAR ELEVATION. SIDE ELEVATION. FRONT ELEVATION. WALL MOUNTED CONTROL PLATE INLET FILTER CONTROLS ENCLOSURE A B DISCHARGE GRILLE INLET FILTER OPTIONAL HANDINGS FOR INLET FILTERS AND CONTROLS ENCLOSURE LH LEFT HAND INLET FILTERS AND CONTROLS ENCLOSURE. REAR REAR INLET FILTERS AND CONTROLS ENCLOSURE (STANDARD CONFIGURATION AS SHOWN ABOVE). 450 450 UNDERSIDE ELEVATION UNIT FIXING HOLES 4 PLACES SPIGOT GRILLE 75 86 AIRFLOW RH RIGHT HAND INLET FILTERS AND CONTROLS ENCLOSURE (AS SHOWN HERE). DISCHARGE GRILLE THE INLET FILTERS AND CONTROLS ENCLOSURE ARE FITTED ON THE REAR OF THE UNIT AS STANDARD, BUT CAN ALTERNATIVELY BE FITTED ON EITHER SIDE OF THE UNIT IF REQUESTED. THE HANDING OF THE INLET FILTERS AND THE CONTROLS ENCLOSURE IS DETERMINED BY LOOKING INTO THE DISCHARGE GRILLE AS SHOWN IN THE DETAIL ABOVE. LPHW COIL CONNECTIONS MODEL DIMENSIONS (ALL VARIANTS) LPHW COIL CONNECTIONS SIZE A B Htg. 1700 1710 1710 2100 2110 2104 2600 2610 2600 3000 3010 3000 ECLIPSE GA Catalogue r1 A1/32927

Established in 1960, Diffusion has over 50 years experience in producing environmental solutions via the manufacture of heating, air conditioning and ventilating products. Diffusion Environmental Systems 47 Central Avenue, West Molesey, Surrey KT8 2QZ Tel: (+44) 020 8783 0033 Fax: (+44) 020 8783 0140 Email: diffusion@etenv.co.uk www.diffusion-group.co.uk Diffusion Environmental Systems have a policy of continuous development. We therefore reserve the right to alter information contained in this leaflet, without prior notice.