RAM Rail Mount Kit RAM 201UD 5 Arm RAM 2461U Base RAM 235U Base, Double U-Bolt

Similar documents
Clutch Control. PN: November 2013 Rev E 1

Ag Leader Technology InSight/Ag Leader Integra. OptRx OptRx Remote Sensor Kit

Instructions for 2-row monitoring only

Instructions for 2-row monitoring only

2-row and All-row systems included.

Rostselmash Torum 740

PFadvantage MF 6850/6855; Ideal 9080/9090

PFadvantage JD 3300/4400/6600/7700; 4420

Flow Sensor

Installation Instructions for John Deere cotton picker models: 9986 & 2-row and All-row systems included.

Part Name/Description Part Number Quantity Instruction Kit Metalfor Flow Sensor

CFX-750 Display with the Field-IQ System: Spraying /Strip Till/Anhydrous Application Quick Reference Card

PFadvantage Metalfor Araus 1360

MF 9520 / 9540 / 9560, Challenger 540C / 560C

Lexion 570R/575R, 580R/585R, 590R/595R

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

Quantity by Model an assembly listed above Early Models Late Models. Instruction Kit JD 9x00/9x

Reference Manual /12

Sprayer Control. Manual for SprayLink Cable Installations. Tank. Jet Agitator. Agitator Valve. Diaphragm Pump. Pressure Transducer.

GPS Steering System Installation Manual

Part Number Part Name/Description Instruction Kit JD 9x50/9x60/9x Flow Sensor

Endeavor Fertilizer Controler" Electric Pump Fertilizer System for John Deere GS2 with Servo Control

Instructions for Micro-Trak Seed Rate Control Systems Used with AgLeader INSIGHT, INTEGRA One, Two and Three Section

GPS AutoSteer System Installation Manual

Quick Setup Guide for IntelliAg Model YP40 20 Air Pro

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

MF 9690, 9790, Challenger 660, 670

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

GPS AutoSteer System Installation Manual

Installation Instructions ISOBUS Liquid ECU

Part Name/Description Part No. PF3000 PF 3000 Pro U-Bracket Short Bracket PF3000 Pro

ROGATOR B RAVEN RS1 ISO GUIDANCE AND STEERING INSTALLATION GUIDE

Planting. Press to Highlight Configuration. Gauge Wheel Load Alarm. Value must be entered for your specific planter and parallel arm combination

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

GPS AutoSteer System Installation Manual

Your Legal Fuel Tank Source.

Lower Adjuster Small Black Header Sensor Reversed

Quick Setup Guide for IntelliAg Model YP Air Pro

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Instruction Kit Gleaner K2, K3, F2, F Flow Sensor K2-F

DeltaForce System Operation

Fast Standard Control Installation Manual FT4

TRAIL CHARGER with EXTENDER and COMBO NOSE BOX

29048, 29049, 29050, 29051, 29052, 29053, 29054,

INSTALLATION INSTRUCTIONS ALL JOHN DEERE SYSTEMS

SharpShooter With Rate Sync for Turf

INSTALLATION MANUAL. Fendt VarioGuide Ready COM 3 Supported Models PN REV A

Universal Mounting Kit #0820

INSTALLATION INSTRUCTIONS

MASTER SALT SAND SPREADER WIRELESS CONTROL MANUAL

Module 13 Rate-controller functions and settings Getting the best out of the functions available

FOR New Electric Kit and Remote Control Installation

Open Center Compact Valve Custom Installation Guide Rev A

NOTE: Indented items indicate parts included in an assembly listed above. Early* Late** M3 M3 Part Name/Description Part No.

CHROME ALLEY CAT L.E.D. FUEL & BATTERY GAUGE 7381

Seed-Squirter. Installation Guide. APPLICATION SYSTEMS FOR PROFESSIONALS. How Can We Help?

29048, 29049, 29050, 29051, 29052, 29053, 29054,

SAC Liquid Manure Flow Meter

SPACESAVER EC-300 A ELECTRICS

GPS AutoSteer System Installation Manual

OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD. PART NUMBER Rev.

Ag Leader Technology. Parts List for Combine MF , 8780, White 9700

Quick Setup Guide for IntelliAg Model 3PYP 12 Row Single Row Air Pro

INSTALLATION INSTRUCTIONS

edrive VSi Installation Guide

Installation Instruction for John Deere cotton picker models:

29048, 29049, 29050, 29051, 29052, 20953, 29054,

Y1. Troubleshooting / Service Guide for SureFire PWM Liquid Application Systems. SureFire Commander II Controller

Clutch Installation Case IH 1200 row unit

SKID MARK GARAGE. Axillary Fuel Supply

Installation Guide CLAAS Lexion Combines with 9 inch Elevators

Installation Instructions for John Deere cotton stripper models:

SlimRack Bed Lift System OEM INSTALLATION MANUAL

HARDI Economy EAGLE Installation Manual HD9

Installation Instructions

AutoGlideXR Installation Procedures for Bestway Sprayer (Can be used for universal fitment)

T2 Terminal Tractor Service Bulletin

INSTRUCTION, HALDEX PUMP LVS KIT P/N

Flow Sensor Gleaner N5-R Flow Sensor Gleaner R40, R

844-E Sprayer Control. Installation, Programming and Operating

Spray Height Controller

29048, 29049, 29050, 29051, 29052, 29053, 29054,

Installation Instructions for John Deere cotton picker models:

HARNESS KIT 3 PORT ISOLATION MODULE LIGHT SYSTEM. Parts List and Installation Instructions CAUTION

Rogator 854, 1054 & 1254 Series Installation Manual RG4

Vehicle Wiring Harness and Cab Control

STRESS-TEK, INC S. 194 th Street Kent, WA June 2011 Stress-Tek, Inc. Doc Rev A

AUXILIARY BATTERY BOX INSTALLATION INSTRUCTIONS

Automatic Roof Hatch Opener

INSTRUCTIONS. EZ-EFI FK In-Tank Fuel Kit

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

Quick Setup Guide for IntelliAg Model YP

Installation Guide. Electronic Entry Device. LA GARD Basic & Gard Series

Table Of Contents TABLE OF CONTENTS INTRODUCTION INSTALLATION OPERATING INSTRUCTIONS APPENDIX ABOUT THE JUICE... 3 SAFETY TERMS...3 INTRODUCTION...

Population pre-def ned Every Row Population. For other pre-def ned are made to the system or if options are added to the base planter.

ISOBUS Down Force Hydraulics Kinze

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

Transcription:

Note: Indented items indicate parts included in an assembly listed above. Part Name/Description Part Number Quantity Direct Command Kit 4100514 1 Installation Instructions 2005690 1 CAN Y-Splice 4000137 1 CAN Bus Terminator 4000141 1 Cable CAN Bus 1 ft. 4000218-1 1 Liquid Product Control Module 4000394-1 1 Cable CAN Bus Stub 8 in., 4000450-1 1 Cable OEM Switch Input 4000527-5 1 Quick Reference Guide- Liquid Application 2002831-38 1 Cable SPX A-Post 4000713-10 1 Cable Boost Module Replacement Cable 4001209-2 1 Cable Power (Guidance) Deutsch 2-Pin 4002093-14 1 RAM Rail Mount Kit 4100101 1 RAM 201UD 5 Arm 4000279 1 RAM 2461U Base 4000280 1 RAM 235U Base, Double U-Bolt 4000281 1 Auxiliary Input Module Kit 4100506 1 Dust Plug 12 pin 2002899-12N 1 CAN Bus Stub 1 ft. 4000219-1 1 Auxiliary Input Module 4000437 1 CAN Y-Splice 4000137 1 Cab Box Kit 4100513 1 Barbed Locking Retainer 2002267 2 Dome Plug 2002268 2 Cab Box 4000598 1 Cab Box Lid 4000599 1 PN: 2005690 Rev. E December 2013 Page 1 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 Important Notices You will save time and prevent wrong installation of components by closely following these step-by-step instructions. If you have questions, call at 515-232-5363 Ext 1. Direction words (LEFT and RIGHT) are commonly used when describing an installation procedure. Interpret direction words as if standing behind equipment and looking forward Signal words (CAUTION, IMPORTANT and NOTE) are provided to draw attention to information that is important for the safe/correct installation and operation of this product. CAUTION will alert you to situations that will impact the physical safety of you or others. IMPORTANT will alert you to the potential for damage to the product or loss of data. NOTE will provide you with additional information to simplify a procedure or clarify a process. This DirectCommand kit fits the following machines: CASE SPX Sprayers 3150, 3185, 3200, 3310, 4260, 4410 Read all instructions first to familiarize yourself with the installation procedures. Keep parts list and installation instructions for use as a reference after completing installation. Section Contents Section Heading Page Common Components 3 Component and Cable Layout 4 Safety Notices 5 Installing the Display 6 Installing the Control Modules 7 Installing the Display Cable and CAN Bus Harness 8 Installing the SPX Adapter Harness 9 Installing the Switch Input Cable 10 Installing the Boost Module Replacement Cable 12 Setting Up the Display 12 Page 2 of 15 December 2013 PN: 2005690 Rev. E

Common Components This section contains illustrations of components common to all Direct Command Installations. Their purpose is to ensure proper identification and installations in the sections that follow. CAN Bus Connectors 1. Terminator PN: 4000141 2. Plug (Not all applications) PN: 4000136 3. Y-Splice PN: 4000137 Modules 1. Auxiliary Input Module PN: 4000437 2. Liquid Product Control Module PN: 4000394 PN: 2005690 Rev. E December 2013 Page 3 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 Component and Cable Layout Page 4 of 15 December 2013 PN: 2005690 Rev. E

Safety Notices CAUTION: Sprayer booms should be lowered to the ground or on mechanical safety stops before starting work. Do not work under sprayer booms supported by hydraulic system only. Turn off machine and wait for all motion to stop before starting work. Set parking brake. CAUTION: Be sure to wear proper eye protection when using any power tools, such as when drilling any mounting holes. IMPORTANT: Check behind vehicle and implement panels for any holes, wiring or controls that could be damaged when drilling any holes. IMPORTANT: Disconnect the Display, DirectCommand components and flow meter from electrical system when welding on equipment or jump starting unit to prevent component damage due to power surges or excessive current. IMPORTANT: If using a non Ag Leader GPS receiver, make sure to install a Null Modem Cable, included in the Display Kit, to prevent damage to the Display or GPS receiver. IMPORTANT: Use Dielectric grease to coat the seals and terminals of each connector that will be exposed to weather or chemicals as you plug them in. NOTE: Be sure to follow the alignment keys on the plugs and the receptacles carefully. Do not use excessive force when mating connectors. PN: 2005690 Rev. E December 2013 Page 5 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 Installing the Display Parts required for procedure: (1) Ag Leader INTEGRA Display PN: 4002000 Or (1) EDGE Display PN: 4001500 Or (1) InSight Display PN: 4001000 From RAM Rail Mount Kit: (1) RAM 201UD 5 Arm PN: 4000279 (1) RAM 2461U Base PN: 4000280 (1) RAM 235U Base, Double U-Bolt PN: 4000281 Step-by-step instructions for installing the Display 1. Turn on the existing Rate Control Console, if equipped with one, and copy down boom section widths and flow meter calibration number. NOTE: The Raven flow meter calibration is in pulses per 10 gallons, the Ag Leader Display requires pulses per gallon for calibration. To calculate the appropriate values, divide the Raven calibration number by 10 before entering into the Ag Leader Display. NOTE: The Raven boom section widths are in inches; the Ag Leader Display requires boom widths in feet. Divide the Raven widths by 12 before entering the widths into the Ag Leader Display. 2. Run the sprayer one last time verifying all sprayer components are functioning. Verifying all sprayer components are working, will help with any potential troubleshooting required after DirectCommand Installation. 3. Shut down existing Rate Control Console, and remove Console and Cabling from the cab. 4. Lay the Display face down on a flat surface and align the four holes in the RAM Mount Base, PN: 4000280 with the mounting holes on the back of the Display. Using the four Phillips pan head screws and lock washers, secure the bracket to the Display. 5. Take the RAM Base, Double U-bolt, and PN: 4000281 from the RAM Rail Mount Kit. Use the two U-bolts, nuts and washers to fasten the mount to the rail where the previous console was installed. 6. Mount the Display in a convenient place for operation, but out of the operator s line of sight while driving sprayer. Page 6 of 15 December 2013 PN: 2005690 Rev. E

Installing the Control Modules Parts required for procedure: From the DirectCommand Kit: (1) Liquid Product Control Module PN: 4000394 From Auxiliary Input Module Kit: (1) Auxiliary Input Module PN: 4000437 From Cab Box Kit: (2) Barbed Locking Retainer PN: 2002267 (1) Dome Plug PN: 2002268 (1) Cab Box PN: 4000598 Step-by-step instructions for installing the Control Modules 1. Position the Cab Box, PN: 4000598 on the floor, underneath the right hand console. Make sure to leave room for cabling. 2. Decide which access hole to route the cables through. Install the corrugated cable protector in the chosen hole and plug the other hole with the Dome Plug, PN: 2002268. NOTE: The Cab Box may be secured to the cab floor mat using the included nylon retainers. The next 2 steps are for that purpose. You may leave the Cab Box unsecured for easier transport from vehicle to vehicle. 3. Mark the location of the holes in the bottom of the box on the floor mat. Remove the box and cut a half-inch slot in the floor mat on the marked locations. 4. Use the Barbed Locking Retainers, PN: 2002267 to secure the Cab Box to the floor by pressing them through the holes of the Cab Box and into the rubber floor mat below. 5. Use the Deutsch Dust Plug PN: 2002899-12N to seal the receptacle marked SWITCH B on the Auxiliary Input Module. 6. Mount the Auxiliary Input Module, PN: 4000437 and Liquid Control Module PN: 4000394 inside the Cab Box. Use the 1/4" nuts and flat washers to secure the modules inside the Cab Box. PN: 2005690 Rev. E December 2013 Page 7 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 Installing the CAN Bus Harness and Display Cable Parts required for procedure: From the DirectCommand Kit: (1) CAN Y-Splice PN: 4000137 (1) CAN Bus Terminator PN: 4000141 (1) CAN Bus Line 1 ft. PN: 4000218-1 (1) CAN Bus Stub 8 in. PN: 4000450-1 From The Display Kit or Display Cable Kit 4100814: (1) Power Control Relay PN: 4000708-1 (1) Display Cable 12 ft. PN: 4001608-12 From Auxiliary Input Module Kit: (1) CAN Bus Stub 1 ft. PN: 4000219-1 (1) CAN Y-Splice PN: 4000137 Step-by-step instructions for installing the CAN Bus Harness and Display Cable 1. Feed the smaller end of the Display Cable, PN: 4001608-12 through the access hole on the Cab Box, route the cable to the right front corner of the cab. 2. Connect the round 28-Pin connector on the Display Cable to the connector on the back of the InSight or EDGE Display, or the connector labeled MAIN on the back of the Ag Leader INTEGRA Display. 3. Plug the Power Control Relay, PN: 4000708-1 into the mating 4-pin Shroud on the Display Cable. Press together until the latch clicks, locking the two together. 4. Connect the single end of first Y-splice, PN: 4000137 to the Display Cable 5. Plug the 1 ft. CAN Bus Stub, PN: 4000219-1 into the gray connector of the Y-Splice. 6. Plug the opposite end of the CAN Bus Stub into the receptacle marked CAN BUS on the Auxiliary Input Module. 7. Connect the CAN Bus Extension Cable, PN: 4000218-1 into the black connection of the Y-Splice. 8. Connect the single end of the second Y-Splice to the opposite end of the CAN Bus Extension Harness. 9. Plug the 8 in. CAN Bus Stub, PN: 4000450-1 into the gray side of the Y-Splice. Page 8 of 15 December 2013 PN: 2005690 Rev. E

10. Plug the opposite end of the CAN Bus Stub into the receptacle marked CAN BUS on the Liquid Control Module. 11. Connect the CAN Bus Terminator, PN: 4000141 to the black side of the Y-Splice. Installing the SPX Adapter Harness Step-by-step instructions for installing the SPX Adapter Harness Parts required for procedure: From the DirectCommand Kit: (1) CASE SPX A-Post Adapter Harness PN: 4000713-10 1. Connect the large round, 24-pin connection of the SPX A-post Adapter Harness, PN: 4000713-10 to the mating connection on the front right corner post of the cab. 2. Connect the 9-pin connection to the mating connection on the same corner post. 3. Route the opposite end of the harness along the right side of the cab and into the Cab Box, feeding all the connectors through the open access hole. 4. Connect the 3 pin Weatherpack Tower of the Adapter Harness to the mating shroud of the Display Cable. 5. Plug the Gray 8-pin plug from the Adapter Harness into the mating receptacle on the Liquid Control Module labeled CHANNEL 1. 6. Plug the Gray 12-pin plug of the Adapter Harness into the mating receptacle on the Liquid Control Module labeled BOOM. 7. Plug the Black 12-pin plug of the Adapter Harness into the mating receptacle on the Liquid Control Module labeled AUXILIARY. 8. Connect the Gray 2-pin plug into the mating receptacle on the wires coming from the Liquid Control Module. 9. Plug the Gray 6-pin plug of the Adapter Harness into the mating receptacle on the Auxiliary Input Module marked RADAR. PN: 2005690 Rev. E December 2013 Page 9 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 Installing the Switch Input Cable Parts required for procedure: From the DirectCommand Kit: (1) Cable OEM Switch Input PN: 4000527-6 (1) Cab Box Lid PN: 4000599 (1) Voltmeter or Test Light Step-by-step instructions for installing the Switch Input Cable 1. Pull up on the armrest to the vertical position so that you can access the bottom of the console. Remove the plastic cover from the bottom of the armrest console. 2. Find the switch with a solid colored wire labeled BOOM 1. NOTE: Generally the first switch in the row of switches is used for a fencerow nozzle. Make sure to confirm this before hooking up the switches and skip over this switch when wiring. 3. Use a test light or voltmeter to verify that the solid colored wire labeled BOOM 1 connected to the switch is the Switched Power (12V) Signal. NOTE: The signal wire should be located next to the power wire for the switch. 4. Remove the plastic connector from the back of the switch. 5. Disconnect the identified wire from the plastic connector. Use a small screwdriver to bend the metal clip on the wire connector removing the signal wire terminal. Page 10 of 15 December 2013 PN: 2005690 Rev. E

Removing signal wire from switch 6. Replace the removed wire with the OEM Switch Cable, PN: 4000527-5, making sure to hook the Boom 1 Wire to the Boom 1 Switch in the armrest. 7. The disconnected wire from the switch must be taped off with electrical tape to prevent the connection from grounding to any part of the console. 8. Fasten the plastic connector onto the back of the switch when finished with the wire transfer. 9. Repeat Steps 2-8 for each of the other boom switches. 10. The master connection needs to be made on the power wire to the switch. Disconnect the red wire from the Boom 6 switch. Plug the red master wire from the OEM Switch Cable into the plastic connector and then plug the power wire back into the mating pigtail on the master switch wire. 11. When finished with the switches, route the green plug on the opposite end of the OEM Switch Cable out the armrest through the back. 12. Secure the armrest cover back into place. 13. Route the 12-pin green plug on the OEM Switch Cable into the Cab Box, and connect it to the mating receptacle on the Auxiliary Input Module, labeled SWITCH A. PN: 2005690 Rev. E December 2013 Page 11 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 14. Install the Cab Box Lid, PN: 4000599 on the Cab Box and secure with the 1/4-turn thumbscrews. Installing the Boost Module Cable Step-by-step instructions for installing the Boost Module Replacement Cable NOTE: Boost Module Replacement Cable is required on SPX 3310 and SPX 4410 Sprayers only. On all other sprayers, this section can be skipped. Parts required for procedure: From DirectCommand Kit: (1) Cable Boost Module Replacement PN: 4001209-2 1. Locate the PWM Boost Module, connected to the PWM Solenoid Control Valve underneath the product tank. 2. Disconnect the Boost Module and remove from the machine. 3. Install the PWM Boost Module Replacement Cable, PN: 4001209-2 where the Boost Module was previously installed. Setting Up the Display 1. Refer to the Quick Reference Guide, PN: 2002831-38 for setting up the Display. 2. Enter the default settings from the following chart for the initial sprayer setup. NOTE: Pay attention to the titles above each table to ensure you are using the right configuration and settings for each application. 3. When necessary, two different machine configurations may be set up when switching between Conventional and AIM Command Spraying modes on sprayers that require different settings for Conventional and AIM Command. Page 12 of 15 December 2013 PN: 2005690 Rev. E

SPX 3200/4260 with KZKCO Control Valve Conventional Mode Only Setting Default Description Name Value Control Valve Configuration Valve Response 1 Valve Response 2 Bypass Servo 40 10 Rate control is achieved through actuating a butterfly or ball valve found in the return line to the solution tank. When the valve opens, the flow decreases and when the valve closes, the flow increases. Determines the speed of the servo valve when product control error exceeds the Response Threshold setting. Decreasing the value will cause the servo valve to run slower. Determines the speed of the servo valve when product control error is less than the Response Threshold setting. Decreasing the value will cause the servo valve to run slower. Response Threshold Allowable Error Flow Meter Cal*** 5 2% See Note Determines where the control system switches between using Valve Response 1 and Valve Response 2 speed settings. Decreasing this value will have the overall effect of speeding up servo valve response. Increasing this value will have the overall effect of slowing down servo valve response. NOTE: Leaving all other valve control settings at the default value and making a small adjustment to this setting is usually all that is required to fine-tune the control system. Determines the percent error that is allowed prior to the product control system making any flow rate corrections. 2-3% is the normal Allowable Error Range Too low of a setting will cause the system to continually hunt for the target application rate. Too high of a setting will cause excessive application error This is the pulses per gallon through the flow meter. Note: Raven flow meter calibration numbers are in pulses per 10 gallons of product flow. To calculate the appropriate values, divide the Raven calibration number by 10 before entering into the Ag Leader Display. ***Verify that the flow meter calibration number is correct by checking the information tag on the flow meter. PN: 2005690 Rev. E December 2013 Page 13 of 15

DirectCommand Installation CASE SPX Sprayers Pre 2008 SPX 4260 with Standard Raven Butterfly Valve Conventional Mode SPX 3150/3185 Conventional Mode SPX 3200/4260/3150/3185/3310/4410 AIM Command Mode Setting Name Control Valve Configuration Valve Response 1 Valve Response 2 Response Threshold Allowable Error Flow Meter Cal*** Default Value Inline Servo 100 24 3 2% See Note Description Rate control is achieved through actuating a butterfly or ball valve found in the solution hose that goes to the booms. When the valve opens, the flow increases and when the valve closes, the flow decreases Determines the speed of the servo valve when product control error exceeds the Response Threshold setting. Decreasing the value will cause the servo valve to run slower. Determines the speed of the servo valve when product control error is less than the Response Threshold setting. Decreasing the value will cause the servo valve to run slower. Determines where the control system switches between using Valve Response 1 and Valve Response 2 speed settings. Decreasing this value will have the overall effect of speeding up servo valve response. Increasing this value will have the overall effect of slowing down servo valve response. NOTE: Leaving all other valve control settings at the default value and making a small adjustment to this setting is usually all that is required to fine-tune the control system. Determines the percent error that is allowed prior to the product control system making any flow rate corrections. 2-3% is the normal Allowable Error Range Too low of a setting will cause the system to continually hunt for the target application rate. Too high of a setting will cause excessive application error This is the pulses per gallon through the flow meter. Note: Raven flow meter calibration numbers are in pulses per 10 gallons of product flow. To calculate the appropriate values, divide the Raven calibration number by 10 before entering into the Ag Leader Display. ***Verify that the flow meter calibration number is correct by checking the information tag on the flow meter. Page 14 of 15 December 2013 PN: 2005690 Rev. E

Setting Name Control Valve Configuration PWM Frequency SPX 3310/4410 Conventional Mode Only Default Description Value PWM 12 Volt 122 Rate control is achieved through speed changes to the solution pump. The PWM pump setting is programmed to control an electric solenoid valve used to adjust the hydraulic flow to the pump. This valve adjusts the application rate indirectly. A constant ground is supplied to the electric solenoid valve and a variable 12 volt PWM signal is provided by the Liquid Control Module to provide rate control This setting is the frequency that the PWM control valve is pulsed at Gain* 700-900** This setting determines how aggressively the control valve responds when making rate change adjustments. The higher the value, the more aggressive the system response is. NOTE: Leaving all other valve control settings at the default value and making a small adjustment to the Gain is usually all that is required to fine-tune the control system. Zero Flow Offset Allowable Error Flow Meter Cal*** 30 2% See Note This setting represents the maximum duty cycle that is sent to the control valve without producing any hydraulic flow from the PWM valve. Using too high of a Zero Flow Offset value can cause the product control system to not properly shut off. Determines the percent error that is allowed prior to the product control system making any flow rate corrections. 2-3% is the normal Allowable Error Range Too low of a setting will cause the system to continually hunt for the target application rate. Too high of a setting will cause excessive application error This is the pulses per gallon through the flow meter. Note: Raven flow meter calibration numbers are in pulses per 10 gallons of product flow. To calculate the appropriate values, divide the Raven calibration number by 10 before entering into the Ag Leader Display. *InSight Displays must have firmware upgraded to version 5.0 or above and the Liquid Product Control Module must be upgraded to firmware version 1.8.00 or above for proper flow control operation using PWM Flow Control. Any Firmware version on EDGE or Ag Leader INTEGRA Displays will work with Liquid Control Module 1.8.00 firmware. **Different machines may vary in the PWM Gain required. Starting with a value in the middle of this range and making small adjustments may be necessary. Some control systems may also require a PWM Gain outside of this range. PN: 2005690 Rev. E December 2013 Page 15 of 15