Similar documents
TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

TC-RHH/RHW-2 USE-2 Copper

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

MTW/TEW UL STYLE MTW/TEW UL STYLES 1028/1283/ UL STYLES 1007/ UL STYLE SWITCHBOARD WIRE (SIS)...

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

THHN10STBRCP1250 THHN 10 STR Brown 1250 CP

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

MC, THHN/THWN-2 Copper

PVC Insulation with Nylon Jacket. Solid or Stranded Soft-annealed Uncoated Copper

Section 8. Portable Cordage & Power Cable

Omni Cable is a master distributor of specialty wire and cable selling

Variable Frequency Drive (VFD) Cable Solutions

Control Cable Type P 600/1000 volts DRILMAR 125-XE Crosslinked Polyolefin Insulated Drilling Rig and Marine Cable

IEEE 1580 TYPE T/N CABLE

MC or MV-105 Copper, TR-XLPE Insulated

Introduction. Phone (888) Fax (800) Int l Phone Int l Fax

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

UNSHIELDED MULTI CONDUCTOR

TUNNELING POWER CABLES

UF103WG250 10/3 WG Uf Cable-250' Features. Material, Color, and Finish. Dimensions and Weight

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

C-L-X Aluminum Sheath Type IEC

ULTROL Still ahead of its time after 30 years Class 1E nuclear rated cable

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

Easier! Faster! Safer!

MEDIUM VOLTAGE

Southwire Company. Current Rating 70 AMPERE (60 DEG C), 85 AMPERE (75 DEG C), 95 AMPERE (90 DEG C) Ground Conductor Size

Type P Drilmar 125-XE Signal & Instrumentation

NEC 2014 Code Changes

Type P Drilmar 125-XE Signal & Instrumentation

STABILOY BRAND FeeDeR SOLuTIONS

Automotive Cables. The Global Cable Solutions Company

WIRE & CABLE OVER A HALF CENTURY OF EXPERTISE

Type P Drilmar 125-XE Power/Distribution Cable Multiconductor

INDUSTRIAL GRADE HIGHLY DURABLE, EASY STRIPPING PORTABLE POWER CABLES

DLO. Mining Cable. Mining Cable. 2 kv

Section 11 Mining Cable

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company

Detailed Specifications & Technical Data

High Voltage Copper, Smooth Aluminum Shield/Sheath

KALAS ENTERTAINMENT CABLE

Armorlite Type MC APPLICATIONS STANDARDS & REFERENCES CONSTRUCTION

Mecklenburg County Common Code Defects

Okoguard -Okoseal Type IEC

Primary, Secondary, Post-Secondary Education Facilities

HOSPITAL AND HEALTHCARE

Variable Frequency Drive (VFD) Cable Solutions

ÖLFLEX VFD 2XL - screened VFD cable for fixed installation or occasional flexing with UL TC-ER.

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

INDUSTRIAL

STABILOY BRAND FEEDER SOLUTIONS INDUSTRIAL FACILITIES AND FACTORIES

ATHLETIC STADIUMS AND SPORTS ARENAS

CABLED TWISTED PAIRS CONDUCTORS

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

CABLED SINGLE CONDUCTORS

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

Electrical Design/Build Guide

E R C. R E R C ; ; W T E C

The Reliable Choice. Field Pocket Guide

PART A General Conductor Requirements

BRONCO PHILATRON. Brand. Premium Flexible Power Cable WIRE AND CABLE * USA MANUFACTURER

SHIELD-FLEX EMI / RFI Shielded Conduit

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Type MMV-WP Medium Voltage Wind Power Cable

Hook-Up Wire Alpha Wire ALPHA 373

CABLE SOLUTIONS. to meet the application needs of nuclear power plants TODAY AND INTO THE FUTURE

Medium Voltage Power Cables

SUBMERSIBLE SECONDARY CONNECTORS SSBC350-4LI. Cond. Range H W L

Medium Voltage Cables for PermaLife Nuclear Utility Applications

Variable Frequency Drive (VFD) Cable Solutions

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

Electronic Instrumentation

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

ALUMINUM UNDERGROUND ALHIDE 600 VOLT SINGLE LAYER RUGGEDIZED CABLES. grounded in service wired to innovate TM. Black Crosslinked.

600/1000 V. 5. Flame Retardancy VDE , DIN EN , IEC

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

SOOW 90 C. Portable Cord. Portable Cord 10.2 SOOW 90 C

Industrial Cable SERVING INDUSTRIAL, SPECIALTY AND COMMERCIAL APPLICATIONS

Airfield Ground Lighting

Category # 1 - Overhead, Primary, & Secondary Conductors

INFORMATION. Hybrid cables. Description

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Detailed Specifications & Technical Data

SHIELD-FLEX EMI / RFI Shielded Conduit

VITALink Taped Splice Pigtail Crimp

Delivering Dependability for More Than a Half Century

SOUTHWEST LOUISIANA ELECTRIC MEMBERSHIP COORPORATION COMMERCIAL SERVICE REQUIREMENTS

Generator Fire Safety: Generator assemblies should be located outside the building.

LCT Shielded Primary UD EPR LCT Shielded Primary UD EPR Cable

Battery Cables. Wire & Cable

20 HUBER+SUHNER RADOX SOLAR

LCT Shielded Primary UD TRXLP LCT Shielded Primary UD TRXLP Cable

Medium Voltage Cable. marmonutility.com

Technical Data Sheet Unshielded (YY) PVC Control Cable

Transcription:

Manufacturing quality. Delivering service. Single Conductors DESCRIPTION: Single copper conductor, tinned stranded insulated with moisture and heat resistant, chemically cross-linked polyethylene insulation (VW-1). Temperature rating 90C in wet and dry location. Switchboard Wire UL Type SIS 600 Volt Copper STANDARDS: UL 44 C(UL) US: CSA/UL Listed Flame Rated: UL 1581 Vertical Flame (VW1) (#14 and larger) ROHS Compliant Dual Rated Type XHHW-2 (#14 & larger) (UL 66 Fixture Wire for #16 AWG) Per ICEA S-95-658 / NEMA WC-70 Gasoline and Oil Resistant II Sunlight Resistant Excellent crush and abrasion resistance -40 C rated Federal Spec AA-59544 Flex-Strand Catalog Number Size AWG or KCMIL Flex-Strand Stock Stranding Class B Stock Class C Stock Insulation Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30ºC Ambient) 90ºCWet/Dry SIS16KT 16 *** 26 7 19 30 0.121 14 8 SIS14KTVW 14 41 7 19 30 0.139 18 25 ** SIS12KTVW 12 65 7 19 30 0.158 26 30 ** SIS10KTVW 10 105 7 19 30 0.182 40 40 ** SIS8HTVW 8 133 7 19 45 0.238 69 55 SIS6HTVW 6 133 7 19 45 0.274 100 75 COLOR CHART Size Blue Black Brown Green Gray Orange Red White Yellow 16 X X 14 X X X X X X X X 12 X X X X X X X 10 X 8 X 6 X *Per NEC Table 310-16 ** The overcurrent protection for items marked ** shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-16 footnote. ***#16 AWG is not recognized as Type SIS or XHHW-2. This conductor will carry one or more of the following listings: FFH-2, RFH-2, RFFH-2, RFHH-3 NOTE: Copper Conductor available Non-Tinned. NOTE: The data shown is approximate and subject to standard industry tolerances. 2007 10 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. Available with tinned conductors. Description: Single conductor, stranded copper, insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type XHHW- 2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead jacket. EnviroPlusTM Power Cable 600 Volt Single Conductor Power Cable XHHW-2 Zero Halogen, Limited Smoke Jacket Standards: LS and CT Rated 1/0 and larger per UL1685 Conductors UL44 ICEA S-95-658/NEMA WC-70 IEEE 388 70,000 BTU flame test 1/0 and larger Federal spec A-A-59544 UL Listed construction Temperature Rating: 90 C Wet/Dry Sunlight resistant; superior water resistance Excellent crush and abrasion resistance Zero Halogen, Limited Smoke Jacket, -40 C Single Conductors Size AWG or MCM Strand (no.) Insulation Thickness (mils) Jacket Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Weight per 1000 feet (lbs.) Ampacity* 30 C Ambient 90 C Wet/Dry 14 7 30 30.20 29 25 12 7 30 30.22 38 30 10 7 30 30.24 53 40 8 7 45 30.30 83 55 6 7 45 30.34 118 75 4 7 45 30.39 173 95 2 7 45 30.45 258 130 1 19 55 45.53 334 150 1/0 19 55 45.60 416 170 2/0 19 55 45.65 509 195 3/0 19 55 45.70 625 225 4/0 19 55 45.75 770 260 250 37 65 65.88 959 290 350 37 65 65.98 1295 350 500 37 65 65 1.12 1793 430 750 61 80 65 1.33 2645 535 *Per NEC-Table 310-16. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG and 30 amps for 10 NOTE: The data shown is approximate and subject to standard industry tolerances. 2008 15 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. Single Conductors Description: Single conductor insulated with heat and moisture resistant, cross-linked polyethylene insulation, (Type USE-2), with an overall flame and sunlight resistant, Zero Halogen, Limited Smoke, Zero Lead jacket. Tinned conductors available. EnviroPlusTM Photovoltaic Cable 1000 Volt Single Conductor Power Cable USE-2 or RHH or RHW-2 Zero Halogen, Limited Smoke Jacket Standards: UL Listed as Type PV Cable Conductors UL854 (#16 per UL 66) ICEA S-95-658/NEMA WC-70 Flame Rated: VW-1 per UL 1685 Temperature Rating: 90 C Wet/Dry Sunlight resistant; superior water resistance Excellent crush and abrasion resistance -40º C Cold Bend and Cold Impact Zero Halogen, Limited Smoke Jacket Size AWG or MCM Strand (no.) Insulation Thickness (mils) Jacket Thickness (mils) Nominal Diameter Overall (inch) Approx. Net Weight per 1000 feet (lbs.) Ampacity* 30 C Ambient 90 C Wet/Dry 16 26 45 30.21 27 8 14 7 45 30.23 34 25 12 7 45 30.25 44 30 10 7 45 30.27 59 40 8 7 60 30.33 90 55 *Per NEC-Table 310-16. The overcurrent protection for items marked with an obelisk ( ) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG and 30 amps for 10. NOTE: The data shown is approximate and subject to standard industry tolerances. 2007 16 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

3 11 2 2

Manufacturing quality. Delivering service. ServiceDrive ASD/VFD Shielded Tray Drive Cable PVC Jacket Overall Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black PVC jacket. Surface printed. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 May be used in ASD / VFD applications Standards: UL 1277 Flame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU) on 1/0 and larger IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial Oil Resistant II Jacket Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S-95-658 / NEMA WC-70 Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) THREE CONDUCTOR 14 7 45 3-#10 60.58 266 25+ 12 7 45 3-#10 60.60 297 30+ 10 7 45 3-#10 60.62 344 40+ 8 7 45 3-#10 60.65 426 55 6 7 45 3-#12 60.73 517 75 4 7 45 3-#10 80.87 772 95 3 7 45 3-#10 80.93 889 110 2 7 45 3-#8 80 1.00 1,118 130 1 19 55 3-#8 80 1.11 1,338 150 1/0 19 55 3-#6 80 1.20 1,671 170 2/0 19 55 3-#6 80 1.29 1,982 195 3/0 19 55 3-#4 80 1.40 2,501 225 4/0 19 55 3-#4 80 1.52 2,982 260 250 37 65 3-#4 110 1.76 3,606 290 350 37 65 3-#2 110 1.99 4,927 350 500 37 65 3-#1 110 2.28 6,712 430 600 61 80 3-1/0 110 2.51 8,028 475 750 61 80 3-2/0 110 2.79 10,113 535 *Per NEC Table 310-16. **Fillers used when required. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-16 footnote. Note: The data shown is approximate and subject to standard industry tolerances. August 2007 Made in the USA www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. ServiceDrive Plus ASD/VFD Shielded Tray Drive Cable Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free, Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with 5-mil helical copper tape shield, and overall flame and sunlight resistant black zero-halogen, limited smoke, zero lead jacket. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 May be used in ASD / VFD applications Standards: UL 1277 Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202 / CSA FT-4, UL 1685 LS Factory Mutual Group 1 Listed Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S-95-658 / NEMA WC-70 Zero Halogen, Limited Smoke, -40C Open wiring (Exposed Runs) 4 AWG and larger Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) THREE CONDUCTOR 14 7 45 3-#10 60.58 271 25+ 12 7 45 3-#10 60.60 301 30+ 10 7 45 3-#10 60.62 349 40+ 8 7 45 3-#10 60.65 431 55 6 7 45 3-#12 60.73 523 75 4 7 45 3-#10 80.87 782 95 3 7 45 3-#10 80.93 900 110 2 7 45 3-#8 80 1.00 1,129 130 1 19 55 3-#8 80 1.11 1,350 150 1/0 19 55 3-#6 80 1.20 1,684 170 2/0 19 55 3-#6 80 1.29 1,996 195 3/0 19 55 3-#4 80 1.40 2,517 225 4/0 19 55 3-#4 80 1.52 2,999 260 250 37 65 3-#4 110 1.76 3,633 290 350 37 65 3-#2 110 1.99 4,958 350 500 37 65 3-#1 110 2.28 6,747 430 600 61 80 3-1/0 110 2.51 8,067 475 750 61 80 3-2/0 110 2.79 10,169 535 *Per NEC Table 310-16. **Fillers used when required. ***Cables marked for open wiring / exposed runs must contain a ground wire + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-16 footnote. Note: The data shown is approximate and subject to standard industry tolerances. August 2007 Made in the USA www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. Description: 3 or 4 conductors, stranded, insulated with heat & moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** & green or bare ground conductor. Cable core covered with binder tape, aluminum or galvanized steel interlocked armor. Jacket upon request. Standards: UL 1569, ICEA S-95-658/NEMA WC-70 NEC Article 330 Cable Tray Rated 600 Volt, 90 C rated dry locations (Wet/Dry with Jacket) Color coding: Black and Numbered with a Green Ground 1/0 AWG and larger: Black and Numbered with a Bare Ground Size AWG or MCM Strand (no.) Insulation Thickness (mils) Insulated Copper Grounding Conductor(s) (AWG) (Green) Feeder Size MC Cable 600V / UL Type MC Galvanized Steel or Aluminum Copper XHHW-2 Applications Service Wire s Feeder Size MC cable is designed to be a cost effective replacement for conduit & wire. Suitable for service, branch & feeder circuits. Ideal for use in commercial, industrial & utility applications. This flexible cable assembly offers: labor/time savings, an increased resistance to mechanical damage, system design flexibility & the reliability of a factory assembled & tested cable system. Features Suitable for use in NEC hazardous locations: Class I, Div. 2 Class II, Div. 2 Two-hour Firewall rated, (2/0 AWG and smaller) For use in Theatres (Article 520), Motion Picture & TV Studios (Article 530) & Places of Assembly with more than 100 people Can be messenger supported (Article 330) Diameter over Armor (inch) Approx. Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor Ampacity* (30 C Ambient Wet/Dry) 90 C Armor Cables TWO FOUR CONDUCTOR THREE CONDUCTOR 8 7 45 10.75 275 357 55 6 7 45 8.83 382 463 75 8 7 45 10.81 333 458 55 6 7 45 8.91 461 601 75 4 7 45 8 1.01 632 790 95 3 7 45 6 1.07 822 970 110 2 7 45 6 1.15 924 1109 130 1 19 55 6 1.31 1178 1341 150 1/0 19 55 6 *** 1.31 1397 1651 170 2/0 19 55 6 *** 1.41 1688 1948 195 3/0 19 55 4 *** 1.51 2097 2397 225 4/0 19 55 4 *** 1.63 2547 2875 260 250 37 65 4 *** 1.81 2983 3428 290 300 37 65 3 *** 1.93 3665 4054 320 350 37 65 3 *** 2.05 4013 4521 350 400 37 65 3 *** 2.17 4777 5213 380 500 37 65 2 *** 2.33 6004 6583 430 600 61 80 2 *** 2.57 6944 7489 475 750 61 80 1 *** 2.85 8617 9308 535 8 7 45 10.89 433 544 44 6 7 45 8.99 611 738 60 4 7 45 8 1.11 847 992 76 3 7 45 6 1.23 1019 1361 88 2 6 45 6 1.33 1262 1521 104 1 19 55 6 1.43 1518 1800 120 1/0 19 55 6 *** 1.43 1788 2069 136 2/0 19 55 6 *** 1.55 2173 2466 156 3/0 19 55 4 *** 1.67 2699 3028 180 4/0 19 55 4 *** 1.79 3293 3658 208 250 37 65 4 *** 1.99 4056 4466 232 300 37 65 3 *** 2.13 4732 5175 256 350 37 65 3 *** 2.25 5494 6964 280 400 37 65 3 *** 2.37 6190 6680 304 500 37 65 2 *** 2.57 7613 8157 344 600 61 80 2 *** 2.85 9035 9644 380 750 61 80 1 *** 3.09 11,250 11,915 428 *Per NEC Table 310-16. **Fillers used when required. *** Bare Copper Grounds. NOTE: The data shown is approximate and subject to standard industry tolerances. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 2007 42 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. Description: 3 or 4 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene (type XHHW-2), phase identified, cabled together with suitable fillers** and bare copper ground conductor(s). Cable core covered with binder tape, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant black PVC jacket. Jacket available under armor and in other colors. Features: Suitable for use in NEC Hazardous locations: Class I, Div. 2 Class II, Div. 2 THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) Interlocked Armor 600 Volt UL Type MC Galvanized Steel or Aluminum Copper XHHW-2 Standards: UL 1569 Flame Rated: IEEE-383 (70,000 BTU), ICEA T-29-520 (210,000 BTU), IEEE 1202/CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant for CT Use; Direct Burial 1, Oil Resistant II Jacket Color Code Black and Numbered / other color codes available Temperature rating at 90 C Wet/Dry ICEA S-95-658/NEMA WC-70 PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Alum. Armor Galv. Armor Ampacity* (30 C Ambient Wet/Dry) 8 7 45 1-#10.750 50.850 410 497 55 6 7 45 1- #8.830 50.930 551 659 75 4 7 45 1- #8.910 50 1.010 735 854 95 3 7 45 1 - #6.970 50 1.070 874 1010 110 2 7 45 1- #6 1.050 50 1.150 1050 1183 130 1 19 55 1- #6 1.230 50 1.330 1283 1445 150 1/0 19 55 1- #6 1.330 50 1.430 1553 1812 170 2/0 19 55 1- #6 1.430 50 1.530 1859 2137 195 3/0 19 55 1- #4 1.550 60 1.670 2314 2612 225 4/0 19 55 1- #4 1.670 60 1.790 2781 3108 260 250 37 65 1- #4 1.810 60 1.930 3356 3725 290 300 37 65 1- #3 1.720 60 2.050 3891 4278 320 350 37 65 1- #3 2.050 60 2.170 4485 4899 350 400 37 65 1- #3 1.960 60 2.290 5030 5461 380 500 37 65 1- #2 2.330 75 2.480 6204 6693 430 600 61 80 1- #2 2.57 75 2.720 7321 7854 475 750 61 80 1- #1 2.850 75 3.000 9062 9626 535 90 C Armor Cables FOUR CONDUCTOR 8 7 45 1-#10.830 50.930 501 598 44 6 7 45 1- #8.930 50 1.030 680 802 60 4 7 45 1- #8 1.010 50 1.110 915 1051 76 3 7 45 1- #6 1.110 50 1.210 1100 1243 88 2 7 45 1- #6 1.230 50 1.330 1323 1484 104 1 19 55 1- #6 1.350 50 1.450 1616 1869 120 1/0 19 55 1- #6 1.430 50 1.530 1928 2209 136 2/0 19 55 1- #6 1.550 60 1.670 2356 2644 156 3/0 19 55 1- #4 1.670 60 1.790 2896 3222 180 4/0 19 55 1- #4 1.790 60 1.910 3503 3868 208 250 37 65 1- #4 1.990 60 2.110 4289 4699 232 300 37 65 1- #3 1.920 60 2.250 4981 5424 256 350 37 65 1- #3 2.250 75 2.400 5824 6395 280 400 37 65 1- #3 2.160 75 2.520 6537 7025 304 500 37 65 1- #2 2.570 75 2.720 7988 8533 344 600 61 80 1- #2 2.850 75 3.000 9450 10060 380 750 61 80 1- #1 3.090 85 3.260 11761 12426 428 *Per NEC Table 310-16. 1 Includes encasement in concrete. **Fillers used when required. NOTE: The data shown is approximate and subject to standard industry tolerances. NOTE: 4-Conductor ampacity assumes all four conductors are hot. If three are hot and one is a neutral, use the three conductor ampacity. 2007 44 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. ServiceDrive ASD/VFD Shielded Interlocked Armor Drive Cable PVC Jacket Overall Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers** and 3 bare copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, galvanized steel interlocked armor, with flame and sunlight resistant PVC jacket overall. Jacket available in colors. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 Suitable for ASD / VFD applications Standards: UL 1569 Flame Rated: IEEE 383 (70,000 BTU), ICEA T-29-520 (210,000 BTU), IEEE 1202 / CSA FT-4 Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Oil Resistant II Jacket Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S-95-658 / NEMA WC-70 THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) (Galvanized) Ampacity* (30 C Ambient Wet/Dry) 14 7 45 3-#14.59 50 0.69 350 25+ 12 7 45 3-#14.63 50 0.73 399 30+ 10 7 45 3-#14.69 50 0.79 473 40+ 8 7 45 3-#14.75 50 0.85 561 55 6 7 45 3-#12.83 50 0.93 726 75 4 7 45 3-#10.93 50 1.03 974 95 3 7 45 3-#10.99 50 1.09 1101 110 2 7 45 3-#8 1.05 50 1.15 1342 130 1 19 55 3-#8 1.23 50 1.33 1586 150 1/0 19 55 3-#6 1.31 50 1.41 2040 170 2/0 19 55 3-#6 1.41 50 1.51 2372 195 3/0 19 55 3-#4 1.51 60 1.63 2915 225 4/0 19 55 3-#4 1.65 60 1.77 3466 260 250 37 65 3-#4 1.81 60 1.93 4113 290 350 37 65 3-#2 2.05 60 2.17 5505 350 500 37 65 3-#1 2.33 75 2.48 7430 430 600 61 80 3-1/0 2.57 75 2.72 8816 475 750 61 80 3-2/0 2.85 75 3.00 10837 535 90 C *Per NEC Table 310-16. 1 Includes encasement in concrete. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-16 footnote. Note: For VFD / ASD applications, galvanized armor should be preferred (for magnetic noise reduction). Note: The data shown is approximate and subject to standard industry tolerances. 2007 Made in the USA www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. ServiceDrive Plus ASD/VFD Shielded Interlocked Armor Drive Cable Factory Mutual Group 1 Listed, Zero Halogen, Limited Smoke, Lead Free Patent Pending Description: 3 conductors, stranded, insulated with heat and moisture resistant cross-linked polyethylene, phase identified, cabled together with suitable fillers and 3 bare copper ground conductors. Cable core covered with binder tape, 5-mil helical copper tape shield, aluminum or galvanized steel interlocked armor, with flame and sunlight resistant zero halogen, limited smoke, zero lead jacket overall. Features: Suitable for use in NEC Hazardous Locations: Class I - Div 2, Class II - Div 2, and Class III, Div 1 and 2 Designed exclusively for ASD / VFD applications. Standards: UL 1569 Flame Rated: IEEE 383 (70,000 BTU), IEEE 1202 / CSA FT-4, UL 1685 LS Factory Mutual Group 1 listed Two-hour Firewall rated, (2/0 AWG and smaller) Sunlight Resistant, for CT Use; Direct Burial 1 Color Code: Black and Numbered Temperature Rating: 90C Wet / Dry ICEA S-95-658 / NEMA WC-70 Zero Halogen, Limited Smoke Jacket, -40C THREE CONDUCTOR Size AWG or MCM Strand (no.) Insulation Thickness (mils) Copper Grounding Conductor(s) (AWG) Diameter over Armor (inch) PVC Jacket Thickness (mils) Approx. Diameter Overall (inch) Approx. Net Wt. per 1000 ft. (lbs.) Ampacity* (30 C Ambient Wet/Dry) 90 C 14 7 45 3-#14.59 50 0.69 355 25+ 12 7 45 3-#14.63 50 0.73 404 30+ 10 7 45 3-#14.69 50 0.79 479 40+ 8 7 45 3-#14.77 50 0.87 569 55 6 7 45 3-#12.85 50 0.95 735 75 4 7 45 3-#10.95 50 1.05 983 95 3 7 45 3-#10 1.01 50 1.11 1109 110 2 7 45 3-#8 1.07 50 1.17 1359 130 1 19 55 3-#8 1.23 50 1.33 1595 150 1/0 19 55 3-#6 1.35 50 1.45 2061 170 2/0 19 55 3-#6 1.43 50 1.51 2393 195 3/0 19 55 3-#4 1.55 60 1.63 2966 225 4/0 19 55 3-#4 1.67 60 1.77 3480 260 250 37 65 3-#4 1.85 60 1.93 4140 290 350 37 65 3-#2 2.09 60 2.17 5542 350 500 37 65 3-#1 2.37 75 2.48 7466 430 600 61 80 3-1/0 2.59 75 2.72 8853 475 750 61 80 3-2/0 2.85 75 3.00 10867 535 *Per NEC Table 310-16. 1 Includes encasement in concrete. + The overcurrent protection for items marked with an obelisk (+) shall not exceed 15 amps for 14 AWG, 20 amps for 12 AWG, and 30 amps for 10 AWG per NEC 310-16 footnote. Note: For VFD / ASD applications, galvanized armor should be preferred (for magnetic noise reduction). Note: The data shown is approximate and subject to standard industry tolerances 2007 Made in the USA www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473

Manufacturing quality. Delivering service. Submersible Pump Cable TYPE THW-Heavy Duty FLAT BLACK JACKETED with Ground 75 C/600V Description & Features: UL listed Type THW heavy duty flat submersible pump cable is a multi-purpose cable with parallel, individually insulated, color coded conductors and an overall jacket. Construction provides flexible copper stranding insulated with Type THW (PVC) compound. A tough PVC jacket, with a non-penetrating web, is easily stripped to facilitate installation yet provide optimum flexibility, mechanical protection and crush resistance. UL listed as Type THW Submersible Pump Cable Acid, alkali, oil and grease resistant Weather, ozone and sunlight resistant jacket Abrasion and crush resistant Sequential footage marks Applications: For use within the well casing to supply power to the submersible pump Designed for use where extra mechanical protection and flexibility during installation and operation are required Construction: Conductors: Flexible stranded soft annealed copper Insulation: Thermoplastic polyvinyl chloride (PVC) Color coding: black, red, yellow, green (ground) Assembly: The insulated conductors, including the grounding conductor, are configured flat and parallel without fillers Jacket: Black thermoplastic polyvinyl chloride (PVC) applied directly over the conductors with a non-penetrating web Temperature: 75 C Voltage: 600 Volts Specifications & Standards: UL Standard 83 TWO OR THREE CONDUCTORS WITH GREEN INSULATED GROUNDING CONDUCTORS Conductor Size, AWG Dimensions (Inches) Standard Ampacity Weight Item Code Power Ground Insulation Jacket O.D. Packaging NEC (Lbs./Mft.) PMP12/2GGHD 12/2 (19 str) 12 (19 str).045.045.280 x.654 500 & 1000 20 152 PMP10/2GGHD 10/2 (19 str) 10 (19 str).045.045.305 x.729 500 & 1000 30 210 PMP14/3GGHD 14/3 (7 str) 14 (7 str).045.045.261 x.763 500 & 1000 15 145 PMP12/3GGHD 12/3 (19 str) 12 (19 str).045.045.280 x.840 500 & 1000 20 189 PMP10/3GGHD 10/3 (19 str) 10 (19 str).045.045.305 x.940 500 & 1000 30 255 PMP8/3GGHD 8/3 (19 str) 10 (19 str).060.045.364 x 1.120 500 & 1000 50 374 PMP6/3GGHD 6/3 (19 str) 8 (19 str).060.045.414 x 1.336 500 & 1000 65 522 PMP4/3GGHD 4/3 (19 str) 8 (19 str).060.045.465 x 1.489 500 & 1000 85 714 PMP2/3GGHD 2/3 (19 str) 6 (19 str).060.045.535 x 1.749 500 & 1000 115 1036 PMP1/03GGHD 1/03 (19 str) 6 (7 str).080.060.660 x 1.990 Bulk 150 1613 PMP2/03GGHD 2/03 (19 str) 6 (7 str).080.060.700 x 2.120 Bulk 175 1932 PMP3/03GGHD 3/03 (19 str) 4 (7 str).080.060 734 x 2.314 Bulk 200 2377 PMP4/03GGHD 4/03 (19 str) 4 (7 str).080.060.800 x 2.490 Bulk 230 2871 PMP250/3GGHD 250/3 (37 str) 4 (7 str).085.080.925 x 2.807 Bulk 235 3518 PMP350/3GGHD 350/3 (37 str) 3 (7 str).095.080 1.031 x 3.153 Bulk 310 4689 Pump and Irrigation Per Table 310-16 of the NEC All values are nominal; all weights are exclusive of packaging. All diameters and weights are subject to normal manufacturing tolerances. * Direct Burial rated in sizes 12 through 4/0 AWG, upon request All sales are subject to Standard Terms & Conditions of Sale. 2007 62 www.servicewire.com Phoenix, AZ Culloden, WV Houston, TX Pittsburgh, PA 877-623-9473 800-624-3572 800-231-9473 800-778-9473