S1 Series. 5-kV and 10-kV Insulation Resistance Testers. S1 Series 5-kV and 10-kV Insulation Resistance Testers

Similar documents
5 kv and 10 kv Insulation Resistance

MIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers

MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kv DC Insulation Resistance Testers

S1-568, S1-1068, S1-1568

MIT515, MIT525, MIT1025, MIT kv, 10 kv, 15 kv DC Insulation resistance testers

MIT515, MIT525, MIT1025, MIT1525

5 kv, 10 kv and 15 kv lead sets Insulation resistance testers

MJÖLNER 200 Microhmmeter

DELTA4000. Accessories

Digital Insulation Resistance Testers. you can depend on

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

DLRO-H200 Microhmmeter

TEST LEADS Digital Low Resistance Ohmmeters

BM kv Digital Insulation Tester USER MANUAL

MIT510/2 5kV Digital Insulation Tester USER MANUAL

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

DLRO TEST LEADS Digital Microhmmeter

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

DELTA4000 Accessories

PAT120, PAT150 and PAT150R

DLRO10HDX 10 Amp Digital Low Resistance

Advanced Test Equipment Rentals ATEC (2832)

5kV Digital Insulation Testers MEGGER

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

Digital Transformer Ratiometer

EUROPE S LARGEST SELECTION OF TEST & MEASUREMENT EQUIPMENT FOR HIRE INLEC.COM. Nationwide Low Call

MIT300 Series Insulation and Continuity testers USER MANUAL

MCE TM Product Information 5 kv Electric Motor Analyzer

MIT300 Series Insulation and Continuity Testers USER MANUAL

MIT515, MIT525, MIT1025, MIT kv, 10 kv & 15 kv Insulation Resistance Testers USER MANUAL

MIT300 Series Insulation and Continuity Testers

LRCD200 Series Combined Loop and RCD Tester USER MANUAL

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

RCDT300 Series Residual Current Device testers USER MANUAL

Multi-Function Ground Resistance Tester Model 6472

MEGGER BM15/MJ15 MEGGER. Insulation Testers. User Guide. MeterCenter (800)

DET3TA, DET3TC, DET3TD and DET4TD Earth Ground Electrode Testers USER MANUAL

USER MANUAL. Insulation Tester + DMM. Model MG320

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

User's Manual Digital High Voltage Insulation Tester Model

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

KMP Insulation-Continuity Tester. Users Manual

Stationary Battery Testing

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

MIT300 Series Insulation and Continuity testers USER MANUAL

MOM2 Handheld High Current Micro-ohmmeter

Baker PPX Power Packs

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes! Motor Circuit Analyzer

EM DC Multi-Function DC Energy Meter

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

MegOhmMeter. Users Manual

Technical Datasheet. Multi-channel support RTC with Data Storage RS485 Output Alarming & Protection Onsite Programmable Load Profile Analysis

Major MEGGER Insulation Testers MJ159, MJ160, MJ359, MJ459, MJ559. User Guide MEGGER

testo 338 Portable Soot and Particulate Meter Versatile, digital display of particulates

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

MOM2 Micro-ohmmeter APPLICATIONS DESCRIPTION. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

EU RO Mutual Recognition Technical Requirements

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Advanced Test Equipment Rentals ATEC (2832)

Model Insulation Tester / Megohmmeter. User Manual

MOM2 Micro-ohmmeter. MOM2 Micro-ohmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Surface mounting, flush mounting, and DIN track mounting

OPERATING INSTRUCTION

FINHRM FINHRM5 FINHRMA FINHRMAC

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Electronic Circuit Breaker ESS20-0..

PORTABLE PRODUCTS for Field Testing High Voltage High Current High Power Test Systems and Components

COMPONENT-TESTER INSTRUCTION MANUAL

Simple Pressure Level Setting. The threshold level is able to adjust simply. Just set the pointer suitable for the displayed pressure level.

engineered to order solutions

EPS/ELA-Series User Manual EPS/ELA 250W

150 WATT HEW SINGLE SERIES DC/DC CONVERTERS

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Construction diagram Semiconductor transducer Silicone oil. Stainless steel SUS316 pressure port Hastelloy C diaphragm.

8 Troubleshooting and Maintenance

Low and High Voltage Power Supplies

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Heavy-Duty Battery and Electrical System Diagnostic Tester

CPU-95EVS Enhanced VariSpark Digital Ignition System for Industrial Engines

KEY FEATURES TEST CAPABILITIES STANDARDS COMPLIANCE

ENGINEERED TO ORDER SOLUTIONS

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Autoranging Multimeter


OPERATING INSTRUCTION

Solid Dielectric, Three Phase Reclosers CATALOG VS11

DLRO10HD and DLRO10HDX. 10 A Digital Low Resistance Ohmmeter. User Guide

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

AC/DC Converter MBP250-2A13D13M

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Transcription:

S1 Series CAT IV 600 V safety rating Line supply or battery operated Noise rejection (2mA or 4mA rms@200v and above) for use in high voltage substations or switchyards 5mA output current provides fast charging and testing of capacitive loads Measurement range to 15 TΩ (5-kV models) and 35 TΩ (10-kV models) Automatic insulation resistance (IR), dielectric absorption ratio (DAR), polarization index (PI), step voltage (SV), and dielectric discharge (DD) tests RS232 or USB download of results On board memory for results storage DESCRIPTION The new Megger S1 Series of 5 kv and 10 kv insulation resistance testers are designed specifically to assist the user with the testing and maintenance of high voltage equipment. This series of testers includes the following models and distinct capabilities including voltage, test current and noise rejection: Model # Output Test Noise Voltage Current Rejection S1-552/2 5 kv 5 ma 2 ma S1-1052/2 10 kv 5 ma 2 ma S1-554/2 5 kv 5 ma 4 ma S1-1054/2 10 kv 5 ma 4 ma All four models are heavy duty and reliable with features that meet the most demanding testing applications in existence today. First, the user has a choice of 5 or 10 kv voltage output capability. The 10 kv option is particularly suitable for testing to the IEEE standards required for testing motors rated greater than 12 kv. Second, all four models provide 5 ma output current to provide fast charging and testing of high capacity loads such as long cables. Third, all four models feature extra noise rejection capability. The Models S1-554/2 and S1-1054/2 incorporate a hardware filter designed to tolerate a industry best 4 ma rms of noise current at 50Hz and above. This filter is enabled by default, but may be switched off in order to speed up the settling time when there is little noise current. The Insulation Resistance mode offers additional firmware filtering to average out slow variations during testing. This virtually eliminates the possibility of poor, unreliable or unstable readings being made in noisy 345-kV and above substations or switchyards. These instruments have been designed with expanded measurement ranges, up to 15TΩ for the 5kV models and up to 35TΩ for the 10kV models, in order to provide trending values for testing high quality insulating materials. A large, easy-to-read backlit LCD is provided on all models making them suitable for use in both bright sunlight and poorly lit environments. Information displayed includes resistance, voltage, leakage current, capacitance, battery status and time constant. In addition, the elapsed time is continuously displayed, removing the need for separate timers. Adjustable timers and limit alarms are included. A built-in, integral timer starts automatically at the beginning of a test, and displays minutes and seconds. At the end of any test, the load is automatically discharged and the decay voltage is displayed. The timer enables the performance of an automatic IR test, plus the capability of preprogrammed DAR, PI, SV and DD. They each include an alarm mode, which allows the operator to preset a specific resistance level. The unit will beep until the limit is exceeded. In addition to the preprogrammed automated testing routines, the units are equally suited for simple insulation testing. The controls of the instruments are clear and unambiguous, and a quick start guide is included in the lid as a permanent refresher for the operator. A guard terminal is provided with each model to allow greater accuracy when testing complex insulation systems with multiple terminals. A guard test lead is included as standard with each instrument.

The S1-552/2 in use at an industrial complex substation With their higher voltage testing capability, the 10-kV models are the perfect tool for manufacturers and users of rotating machinery. Designed in accordance with the requirements of IEEE43-2000 they are ideal for measuring the insulation resistance of armature and field windings in rotating machines rated 1hp (750 W) or greater. The standard applies to synchronous, induction and dc machines as well as synchronous condensers. All models provide variable test voltages in 10V steps below 1kV and 25V steps above 1kV to enhance their flexibility, and to eliminate the need for multiple IR test sets to meet various applications. Fast, repeatable measurements are possible on large motors, generators and cables due to the 5mA of charging current provided by the instrument, the highest available on the market. Testing can be performed when the instrument is powered by AC mains or when powered by its internal rechargeable battery. Built-in safety features enhance the operation of the units. If connected to a live test specimen, the external voltage will be displayed and testing will not be allowed if above 50V with the 5kV models or above 80V with the 10kV models. At the conclusion of every test, the instruments display the voltage remaining on the connected equipment and automatically discharge the residual energy. APPLICATIONS The S1 Series of insulation resistance testers are designed for testing the insulation of high-voltage electric equipment. Their wide voltage range also allows applications for low-voltage equipment. Generators, motors, transformers, cables and switchgear all require effective maintenance. The test techniques on the instruments provide valuable diagnostic information. All models test the insulation resistance of: High-voltage power cables and high-voltage buses Large motor/generator windings Line and substation transformers They perform spot tests, step-voltage tests, and dielectric absorption tests for the following applications: Acceptance testing at an installation to check conformance to specifications. Routine preventive/predictive maintenance testing after installation. Quality assurance testing as part of the manufacturing process. Diagnostic testing to isolate faulty components for repair. Contamination testing of service aged insulation. FEATURES AND BENEFITS CAT IV 600 V safety rating allows for safe use in the widest range of applications. Improved operating flexibility provides the user with the choice of using these instruments via line or battery operation. Line operation also affords enhanced charging capabilities for high-capacitance test samples. High measurement range enables installation testing and long-term trending of higher value apparatus. 5 ma short circuit current allows for faster charging and testing of large capacitive and inductive loads Results storage and downloading enables state-of-the-art record keeping free of transposition errors. The S1-554/2 and S1-1054/2 provide the ultimate in noise rejection that will even cope in extreme conditions such as 345-kV to 500-kV substations and switchyards. Five industry-standard tests can be performed automatically, freeing operator from time-consuming manual operations. Backlit display enables ease of testing in poorly lit areas. Rugged, lightweight polypropylene case and IP65 rating make all of the instruments adaptable for all field conditions. A variety of measurements including applied test voltage, leakage current and capacitance, affords enhanced capabilities to diagnose insulation condition and problems. Redundant safety features includes automatic discharge of test item, test lockout in presence of external voltage, and design to EN61010. Models S1-1052/2 and S1-1054/2 incorporate the ability to apply test voltage up to 10 kv, making both fully conformable to the requirements of IEEE43-2000. A quick start guide is included in the lid, eliminating the need to carry bulky manuals to site locations. For greater ease of use and downloading, an RS232 or USB interface is available. Alarm limit mode allows for faster testing and less ambiguous result interpretation. Circuit breaker being tested with the S1-552/2

These unique features improve insulation testing efficiency and effectiveness Extra data storage and download capability Run more tests and save more test data. Download results using either an RS232 or USB style connection. Easier operation Use a Quick Start guide conveniently located in the lid, always there for easy reference. Improved enclosure It s virtually indestructible, yet ergonomic and lightweight. It features an oversized rubber handle and removable lid for effective use in tight places. A lid mounted lead storage bag is also included. Line or battery operation The operating flexibility you need when site conditions are unknown or long term testing is required.

Product Features and Benefits Guide FEATURES S1-552/2 S1-554/2 BENEFITS 5-kV max test voltage Industry standard Full conformity to IEEE43-2000 10-kV max test voltage Future proofs against new insulation technology 5 ma SC output current Ultimate fast charge of capacitance Maintain test voltage at lower MΩ CAT IV 600 V safety Ultimate in safety Full diagnostic test capability Provides full information on insulation quality (PI, DAR, SV, DD) Test result memory Essential for trending results S1-1052/2 S1-1054/2 2 ma noise immunity High noise immunity 4 ma noise immunity Ultimate noise immunity for locations such as 345-kV to 500-kV substations and switchyards Shielded leads supplied std. Additional noise protection S1-552/2 shown with included accessories S1-1052/2 shown with included accessories S1-554/2 shown with included accessories S1-1054/2 shown with included accessories

SPECIFICATIONS Models S1-552/2 Models S1-1052/2 and S1-554/2 and S1-1054/2 Battery Life 6 hours 4 hours continuous testing continuous testing at 5kV at 10kV Test Voltages 50V to 1 kv 50V to 1 kv in 10V steps in 10V steps 1 kv to 5 kv 1 kv to 10 kv in 25V steps in 25V steps Accuracy ±5% to 1 TΩ ±5% to 2 TΩ ±20% to 10 TΩ ±20% to 20 TΩ Display Range Digital Display (3 digit) 10 kω to 15 TΩ 10 kω to 35 TΩ Analog Display 100 kω to 1 TΩ 100 kω to 1 TΩ Capacitor Charge Time <1.5 seconds <3 seconds per µf per µf at 5mA to 5kV at 5mA to 10kV Capacitor <120ms per µf <250ms per µf Discharge Time to discharge from to discharge from 5000V to 50V 10000V to 50V Voltage input range: 95-240 V ±-10% rms 50/60Hz Guard: 2% error guarding 500 kω leakage with 100 MΩ load Short circuit/charge current: 5 ma Capacitance measurement: 10 nf to 50 µf (dependant on measurement voltage) Capacitance measurement accuracy (23 C): ±5% ±5 nf Voltage output accuracy (0 C to 30 C): +4% ±10 V of nominal test voltage at 1 GΩ load ±25 V for test voltages less than 500 V Current measurement range: 0.01 na to 5 ma Current measurement accuracy (23 C): ±5% ±0.2 na at all voltages 6 5 5kV Voltage Characteristic Display: Analog/digital 3 digits Interference rejection: 2 ma rms @ 200 V and above (S1-552/2 and S1-1052/2) 4 marms @ 200 V and above (S1-554/2 and S1-1054/2) Filter (models S1-554/2 and S1-1054/2 only 10, 30 and 100 second time constants (selectable) Timer range: Up to 99 minutes and 59 seconds from start of test Memory capacity: 32kB Pre Programmed Test Routines: Auto Insulation Resistance (IR) Polarization Index (PI) Dielectric Absorption Ratio (DAR) Step Voltage (SV) Dielectric Discharge (DD) Interface: RS232 and USB Data storage: Voltage, test time, leakage current, resistance, PI, DAR, DD, capacitance and time constant Real time output: Serial, once per second of test voltage, current and resistance Temperature Range: Operating: -4ºF to 122ºF (-20ºC to +50ºC) Storage: -13ºF to +149ºF (-25ºC to +65ºC) Ingress protection (lid closed): IP65 Humidity: 90% RH non-condensing at 40 C Safety: Meets the requirements of EN61010-1:2001 CATIV 600 V EMC Meets the requirements of EN61326-1:1998 for use in heavy industrial areas. Dimensions: 12.7 x 6 x 14.2 in. (305 x 194 x 360 mm) Weight: 16 lb (7.1 kg) approx. kv 4 3 2 5kV 2.5kV 1kV 500V 250V 1 0 0 1 2 3 4 5 6 7 8 9 10 M Ohms Test Voltage Output Characteristics Over Insulation Resistance Range

S1-552/2 & S1-1052/2 DISPLAY EXAMPLE 1 15 14 13 12 11 2 3 10 4 4 5 9 6 7 8 1. Voltage at terminals Displays amount of voltage present at the terminal. 2. Battery level Indicates the level of battery operation available. 3. Breakdown indicator Indicates that breakdown mode is in operation. 4. High-voltage indicator Indicates the presence of high voltage during operation. 5. Digital display Displays the reading during a test. 6. Dielectric absorption ratio (DAR) 7. Polarization index (PI) 8. Time constant 6 through 8 Displays the ratio value or the resistance measured at the indicated time. 9. Capacitance display Indicates the capacitance of the test sample. 10. Analog display Unique, patented analog display shows test voltage with real-time pointer movement. 11. Timer Displays the elapsed time of test. Displayed constantly, eliminating the need for a separate timer. 12. Data recording Indicates if data is being recorded during the test. 13. Alarm Indicates that alarm has been set. 14. Burn indicator Indicates that burn mode is in operation. 15. Test modes Shows which pre-programmed test is being run. ORDERING INFORMATION Item Cat. No. S1-552/2 5 kv Insulation Resistance Tester 1000-384 S1-554/2 5 kv Insulation Resistance Tester 1000-390 S1-1052/2 10 kv Insulation Resistance Tester 1000-387 S1-1054/2 10 kv Insulation Resistance Tester 1000-393 Included Accessories for all instruments 3m lead set medium insulated clips 6220-820 RS232 cable 25955-025 USB cable 25970-041 User guide on CD-ROM 6172-988 Lid mounted pouch 6320-244 PowerDB LITE CD-ROM DB0001 S1-554/2 and S1-1054/2 also includes 10 m shielded lead set, compact clips 6220-861 Accessory carry bag 6420-143 S1-1052/2 and S1-1054/2 also includes 3 x 3 m, lead set large insulated clips 6220-811 Optional Accessories Item Cat. No. HV Lead Sets: 3 x 3m uninsulated compact clips 8101-181 3 x 8m uninsulated compact clips 8101-182 3 x 15m uninsulated compact clips 8101-183 3 x 10m medium insulated clips 1000-441 3 x 15m large insulated clips 1000-442 3 x 3m large insulated clips 6220-811 3 x 10m large insulated clips 1000-443 3 x 15m large insulated clips 1000-432 Control Circuit Test Lead Sets: 2 x 3m small insulated clips 6220-822 Shielded HV Test Lead Sets: 1 x 3m 5-kV, uninsulated compact clip 6220-835 1 x 15m, 5-kV, uninsulated compact clip 6311-080 1 x 3m, 10-kV, uninsulated compact clip 6220-834 1 x 10m, 10-kV, uninsulated compact clip 6220-861 1 x 15m, 10-kV, uninsulated compact clip 6220-833 UK Archcliffe Road, Dover CT17 9EN England T +44 (0) 1 304 502101 F +44 (0) 1 304 207342 UKsales@megger.com UNITED STATES 4271 Bronze Way Dallas, TX 75237-1019 USA T 1 800 723 2861 (USA only) T +1 214 333 3201 F +1 214 331 7399 USsales@megger.com OTHER TECHNICAL SALES OFFICES Täby SWEDEN, Norristown USA, Sydney AUSTRALIA, Toronto CANADA, Trappes FRANCE, Kingdom of BAHRAIN, Mumbai INDIA, Johannesburg SOUTH AFRICA, and Chonburi THAILAND ISO STATEMENT Registered to ISO 9001:2000 Reg no. Q 09250 Registered to ISO 14001 Reg no. EMS 61597 S1 SERIES/2_DS_USen_V02 www.megger.com Megger is a registered trademark