FPT Series Poke-Through: Power and Communications Four 20A, two circuits, six 2 AWG wires, prewired, pigtail ends in junction box (can be wired as isolated, labels provided) Keystone Communications Device Plate with four Keystone Category 5e Data Jacks see page C65 for optional Communications Device Plates for Integral in. threaded conduit hub for communication wiring (cast iron) 9 in. FPT-P-C-TBRS FPT-P-C-TALM FPT-P-C-TBLK FPT-P-C Brass Cover Aluminum Cover Black Cover Poke-Through Base (cover purchased separately) in. Threaded Hub for Communications /2 in. Threaded Hub for Power FPT Series Poke-Through: Covers Brushed-Metal Finishes Powder-Coat Finishes 7-/2 in. Brass Black FPT-CVR-TBRS Brushed Brass FPT-CVR-TALM Brushed Aluminum FPT-CVR-TBLK Aluminum with Black Powder Coat Finish FPT-CVR-TBGE Aluminum with Beige Powder Coat Finish FPT-CVR-TBRN Aluminum with Brown Powder Coat Finish Forged solid brass and aluminum covers. Patented latching lid closes easily without the need for locking screws Aluminum Beige Brown FPT Series Poke-Through: 2 Power and 6 Communications Four 20A, two circuits, six 2 AWG wires, prewired, pigtail ends in junction box (can be wired as isolated, labels provided) Includes Keystone Communications Device Plate with six Keystone in. Threaded Hub Category 5e Data Jacks see page C65 for optional Communications Device Plates for and FPT-2P-6C FPT-CCH-6C Poke-Through Base Unit Only (cover purchased separately) Optional in. Threaded Conduit Hub for communications Wiring (cast iron) FPT-CCH-6C /2 in. Threaded Hub for Power Two 3/ in. Thru-Holes for Communications 9 in. C63
FPT Series Poke-Through: 8 Communications (Left) (Right) (Center) Three 3/ in. Thru-Holes for Communications Keystone Communications Device Plates with eight Keystone Category 5e Data Jacks see page C65 for optional Communications Device Plates for and No Junction Box FPT-CCH-8C (Cover purchased separately) 3-/ in. -/ in. Threaded Hub FPT-8C FPT-CCH-8C Poke-Through Base (cover purchased separately) Optional -/ in. Threaded Conduit Hub for communications Wiring (cast iron) FPT Series Poke-Through: Locking Receptacle and 2 Communications 20A Receptacle: pre-wired, three 2 AWG wires, pigtail ends in junction box 30A Receptacle: pre-wired, three 0 AWG wires, pigtail ends in junction box Cover purchased separately Includes Keystone Communications Device Plates with two Keystone Category 5e Data Jacks see page C65 for optional Communications Device Plates for 9-3/ in. /2 in. Threaded Hub for Power FPT-TL2-2C Poke-Through Base, NEMA L5-20R, 20A/25V 3/ in. Thru Hole for Communications FPT-TL22-2C FPT-TL3-2C Poke-Through Base, NEMA L6-20R, 20A/250V Poke-Through Base, NEMA L5-30R, 30A/25V FPT-CCH-2P FPT-TL32-2C FPT-CCH-2P Poke-Through Base, NEMA L6-30R, 30A/250V Optional /2 in. Threaded Conduit Hub for communications Wiring (cast iron) /2 in. Threaded Hub (Cover purchased separately) C6
FPT Series Optional Communications Device Plates Plates Plates FPT-CPA-SYS FPT-CPB-2SYS FPT-CPA-3PAN** FPT-CPB-2PAN** FPT-CPA-KEY FPT-CPB-2KEY FPT-CPA-MAAP FPT-CPA-ORT FPT-CPA-BLANK Compartment A-B Plate*** FPT-CPB-MAAP FPT-CPB-2ORT FPT-CPB-BLANK FPT-CPAB-2MAAP FPT-CPA-KEY For Keystone Jacks * FPT-CPA-SYS For Systemax Jacks FPT-CPA-3PAN ** For 3 PANDUIT Jacks ** FPT-CPA-MAAP For Extron MAAP Plate, Single Space FPT-CPA-0RT For Ortronics Jacks FPT-CPA-BLANK Blank FPT-CPB-2KEY For 2 Keystone Jacks * FPT-CPB-2SYS For 2 Systemax Jacks FPT-CPB-2PAN ** For 2 PANDUIT Jacks ** FPT-CPB-MAAP For Extron MAAP Plate, Single Space FPT-CPB-20RT For 2 Ortronics Jacks FPT-CPB-BLANK Blank FPT-CPAB-2MAAP For Extron MAAP Plate, Double Space -B CSA not applicable Device Plate Only no jacks included * Keystone plates also accept Leviton and Hubbell devices ** Requires CMNZABL-X adapter from PANDUIT to mount PANDUIT MiniCom jacks *** For use with FPT-2P-6C and FPT-8C Series only; replaces one plate and one plate Listed trademarks are owned by their respective companies. FPT Series Replacement Power Insert 2 For use with FPT-P-C and FPT-2P-6C Series Poke-Through Systems FPT-2P-RPL Replacement Power Insert with 8 in. Wire Whip Two 20A C65
This aesthetic, easy-to-use Poke-Through provides an ideal power and data solution great for new construction for upgrading existing 3 in. core installations. Capacity: duplex receptacle and 2 data jacks (included) Core Drill Size 3 in. Durable solid brass or aluminum covers protect devices from damage and debris when not in use no exposed plastic components Powder-coated aluminum covers are available in black, grey, brown and beige to match any décor the most colours in the industry Brushed brass and aluminum finishes provide superior aesthetics Slide latches enable tool-less access to individual receptacles eliminates the need for hard-to-use locking screws Accepts Keystone, Leviton or Hubbell data jacks Junction box features (3) /2 in. and () 3/ in. knockouts (3 cubic inch capacity) Includes () 20A duplex receptacle, pre-wired, pigtail ends in junction box Includes (2) Leviton CAT 5e data jacks FPT3 Series Poke-Through: 2 Power and 2 Communications 6-/ in. 7-/2 in. Slide latch to release or 2 flip lids Two 7/6 in. Thru-Hole for Communications 7/6 in. Conduit for Power Poke-Through Base Unit FPT3-2P-2C-BRS Brushed-Brass Cover FPT3-2P-2C-ALM Brushed-Aluminum Cover FPT3-2P-2C-BLK Black Powder-Coat Cover FPT3 Series Poke-Through Base Unit Only: FPT3-2P-2C (Cover purchased separately) Poke-Through Covers FPT3-CVR-BRS Solid Brass, Brushed Finish FPT3-CVR-ALM Solid Aluminum, Brushed Finish FPT3-CVR-BLK Aluminum with Black Powder-Coat Finish FPT3-CVR-GRY Aluminum with Grey Powder-Coat Finish FPT3-CVR-BGE Aluminum with Beige Powder-Coat Finish FPT3-CVR-BRN Aluminum with Brown Powder-Coat Finish See page C67 to view brushed metal and powder coat finishes Slide latch to release or 2 lids C66
RPT6 Series Recessed Poke-Through Given the limitations on the number of holes that can be drilled in a floor, it is important to maximize the capacity of each location. The RPT6 series offers a configurable solution that provides high capacity for both power wiring and communications cabling in a single-core drill location. Greater capacity than typical 3 in. and in. core poke-throughs Core drill size: 6 in. Solid brass, black and brushed aluminum finishes provide superior aesthetics and durability Customer can use off-the-shelf wiring devices Center compartment can accept GFCIs Recessed service conceals devices below floor level Configurable compartment bottom junction box includes a cover with -/ in., -/2 in. or 2 in. knockouts UL 263 2-hour fire test Center compartment can accept GFCIs The new interactive 3D view of the RPT6 is available online under Left compartment accept standard devices Right compartment accept standard devices RPT6-3G-BRS RPT6 series poke-through Assembly: Base unit with solid brass cover Shown without cover 3 gang recessed compartment Note: power and data devices are not furnished RPT6-3G-BLK RPT6-3G-ALM RPT6 series poke-through Assembly: Base unit with black cover RPT6 series poke-through Assembly: Base unit with brushed aluminum cover RPT6 Series Recessed Poke-Through Covers RPT6-CVR-BRS Solid brass cover RPT6-CVR-BLK Black cover RPT6-CVR-ALM Brushed aluminum cover Moptite covers meet UL scrub-water exclusion requirements for carpet, tile and wood. 8 in. -/2 in. Cover shown with cord exit closed Solid Brass Black Brushed Aluminum C67
FPT Flush Series Poke-Through: 2 Power The Steel City FPT Poke-Through Series provides an economical solution for installing a duplex receptacle in an existing floor right where you need it. Capacity: duplex receptacle Core Drill Size 3 in. Brushed brass and aluminum covers provide superior aesthetics and durability Nonmetallic covers are available in black, grey, beige and brown Nonmetallic covers include openings for 3 communications cables Integral junction box features (5) /2 in. and (5) 3/ in. knockouts (27 cubic inch capacity) Assembled units include () 20A duplex receptacle, pre-wired with pigtail ends in junction box FPT-9 FPT-50 FPT-5-SW-BLK FPT-5-SW-GRY FPT-5-SW-BGE FPT-5-SW-BRN FPT-5-SW-BRS FPT-00B With Solid Brass Cover With Solid Aluminum Cover With Black Nonmetallic Cover With Grey Nonmetallic Cover With Beige Nonmetallic Cover With Brown Nonmetallic Cover With Brass Cover FPT Poke-Through Base Unit Only (no duplex) (Cover purchased separately) 5-3/ in. Opening for Communication (Equivalent to Two 3/ in. Conduits) Metallic Cover 7 in. Nonmetallic Cover Removable KOs for Communication Cables (Qty. = 3) Opening for Power (Equivalent to One /2 in. Conduit) 6 in. FPT Flush Series Poke-Through Covers Nonmetallic covers feature openings for 3 communication cables Brushed-Metal Finishes Nonmetallic Colours and Finishes FPT-CACP FPT-CACP-AL FPT--SW-BLK* FPT--SW-GRY* FPT--SW-BGE* FPT--SW-BRN* *Not CSA Certified Solid Brass, Brushed Finish, 5-3/ in. Diameter Solid Aluminum, Brushed Finish, 5-3/ in. Diameter Black, Nonmetallic, 7 in. Diameter Grey, Nonmetallic, 7 in. Diameter Beige, Nonmetallic, 7 in. Diameter Brown, Nonmetallic, 7 in. Diameter 0 FPT-CACP Solid Brass FPT-CACP-AL Solid Aluminum FPT--SW-BLK Black FPT--SW-BGE Beige FPT--SW-GRY Grey FPT--SW-BRN Brown C68
Technical Specifications Fire Rating and Concrete Thickness Min./Max. (all series) For use in -, -/2 and 2-hour rated floors -hour rated floor: 2-/ in. minimum concrete over steel decking 3 in. minimum concrete for reinforced slab 7-/2 in. maximum concrete thickness 2-hour rated floor: 3-/ in. minimum concrete over steel decking in. minimum concrete for reinforced slab 7-/2 in. maximum concrete thickness FPT Series FPT3 Series (Left) (Center) Poke-Through Series (Left) (Right) Maximum Allowable Copper Cross-Sectional Area for Communications Cabling (Left) (Center) (Center) (Right) FPT-P-C Power 0.0630 sq. in. Power FPT-2P-6C Power 0.0630 sq. in. 0.0536 sq. in. FPT-8C 0.0536 sq. in. 0.0630 sq. in. 0.0536 sq. in. FPT-TL-2C Power Power 0.0536 sq. in. FPT3-2P-2C 0.0032 sq. in. Power 0.0032 sq. in. Cross-Selectional Area for Common Copper Conductors 2 AWG 0.00032 sq. in. 22 AWG 0.00050 sq. in. AWG 0.00323 sq. in. 2 AWG 0.0052 sq. in. 0 AWG 0.0065 sq. in. 8 AWG 0.0296 sq. in. Solid or stranded wires (Right) RPT Series The RPT Series has been superseded by the FPT Series RPT Series FPT Series RPT-P-2RJ FPT-P-C RPT-2P-RJ FPT-2P-6C RPT-6RJ FPT-8C Maximum Allowable Copper Cross- Sectional Area for Communications Cabling Furniture Feed Poke-Through Systems FFPT Series: 3/ in. Hub for Power -/ in. Hub for Communications FFPT3 Series: 2 in. Hub for Power or Communications Materials FPT Series: Conduit Hubs: Cast Iron FPT3 Series: FPT Flush/Furniture Feed/Pedestal Series:, nonmetallic polycarbonate Base: Phenolic, galvanized steel & intumescent fire-stop FFPT Series: FFPT3 Series: Installation Spacing Minimum of 2-ft on center Not more than one Poke-Through per 65 sq. ft. of floor area in each span C7