EU Regulation for Premium Efficiency IE3 motors 2, 4, 6 poles efficienza

Similar documents
Efficiency classes of single-speed three-phase, cage-induction motors

EU MEPS for low voltage electric motors

HIGH EFFICIENCY INDUCTION MOTORS COMBROHEF001_=

New efficiency standards and directives applicable to motors in Europe

High efficiency induction motors

COMBROIND001_= THREE PHASE SQUIRREL CAGE INDUCTION MOTORS. IE1 motors MAA - BAA Series IE2 motors MAQ - BAQ Series

COMMISSION REGULATION (EC)

Brochure EU MEPS Efficiency requirements for low voltage motors Updated for stage 3 requirements from January 1, 2017

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

الهيئة السعىدية للمىاصفبت والمقبييس والجىدة Saudi Standards, Metrology and Quality Org (SASO)

EFFICIENCY REGULATIONS FOR MOTORS AND MOTOR SYSTEMS

Five years ahead of the future...

How do you take the first step towards an energy efficient future?

SIMOTICS Frei verwendbar / Siemens AG Alle Rechte vorbehalten.

customized drive solutions

High Efficiency Induction Motors IE2. MarelliMotori MAQ - BAQ SERIES FRAME SIZES ASI.CT GB

NEW Explosion protection

Press information. Using energy-efficient electric Motors. Meeting the International Energy Directives. October 2013

Synchronous motor & drive package Low Voltage motors and drives

Best Practice High Eff iciency Motors

Catalog June 2016 Low voltage General performance motors

Lenze ATEX-compliant gearboxes Gearboxes for use in potentially explosive atmospheres

WORLD Energy regulation guideline

Recent Development in Energy Efficiency Policy in the EU

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Motors at a Pump Manufacturer. Michael Meier-Wagner, Vice President Group Motors, Zürich, 21 November 2017

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

EuP & Electric Motor legislation. Chris Lawton CSO

From 16 June 2011, motors placed for the first-time on the market shall have a minimum efficiency class of IE2.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Energy savings in drive applications

Asynchronous, Low Voltage, Squirrel Cage, Three Phase Electric Motors

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

Hydro Generators Blue Powered Green Energy

Catalog. Variable Speed Gearmotors. Edition 08/2004 A3.D / EN

THREE PHASE ASYNCHRONOUS MOTORS. MS/S Series (frame Aluminum) TC Series (frame Cast iron) Y Series (frame Cast iron)

How to implement higher efficiency motors

The SINOCHRON Motor - The Energy saver amongst Electric Motors

Catalog March 2016 Low voltage Process performance motors

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS IE3 IE2

Powerful centrifugal fans for universal use: The product ranges TEM and REM

Table of contents. Three-phase asynchronous motors DA

INTRODUCTION L-CAGS-E-170. Elevated output

GOVERNMENT APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

UZB GENERAL DESCRIPTION 2. SHORT-FORM DATA 3. ORDER NUMBERS 4. MARKINGS BATTERY REPLACEMENT BATTERY REPLACEMENT 12V, 12AH 1/6.

SWE SERIES (IE3) WONDER ELECTRIC MOTOR (S) PTE LTD. Energy Saving Low Noise Environmental Friendly IEC Dimension Low Vibration European Design

THREE PHASE ASYNCHRONOUS MOTORS WITH SQUIRREL CAGE

Sarah Hatch, Senior Project Officer - Lighting and Equipment Energy Efficiency Team DEWHA October 2008

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Catalog January 2017 Standard low voltage motors Regional catalog for Middle-East and Africa

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

4 Project planning for drives

ASYNCHRONOUS MOTORS THREE-PHASE MOTORS SINGLE-PHASE MOTORS BRAKE MOTORS IE3 IE2

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

Standardmotoren Standard motors

Catalog October 2014 Low voltage General performance motors according to EU MEPS

IE3 RANGE PREMIUM EFFICIENCY THREE-PHASE MOTORS

Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

Including list of all affected Side Channel Blowers. Information about IE2, IE3 and NEMA motor changeover for blowers and side channel blowers

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

ABB Motors and Generators Training. Sharing knowledge and creating value

Factor 1) Modulating torque 4) [Nm] 200 F14 G1/2 GK : :

Three Phase Squirrel Cage Induction Motors

Motors- Basic principles. Expertise, performance, innovation

Modular Flameproof Brakes

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

APPLICATION GUIDE. ACH580 Alternative motor technologies in HVAC

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

High quality and washdown tolerant

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

AESV / AESU / AESV-LA Series Squirrel Cage Induction Motor AESV1S / AESU1S / AESV1S-LA (IE1) STANDARD EFFICIENCY

Powerful centrifugal fans for universal use: The product ranges TEM and REM

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

Explosion proof electric motor For Fuel dispensing application. Main characteristic

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Technical specifications

Table of contents. Three-phase asynchronous motors DA

Specifications. C13 Generator Set Electric Power

AC Synchronous Reluctance motors

Modular DR motor concept: Standard AC motors and energy-efficient motors of efficiency class IE

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

CJBD/ALF CJBX/ALS CJBX/ALF CJBD/ALS VENTILATION UNITS WITH ALUMINIUM PROFILES. According EU Regulation

ABB Motors and Generators Training. Sharing knowledge and creating value

like mission critical Backed by the worldwide l provide the reliabi Mission Critical LEHE1075

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

IEC : CONTENTS

Low voltage asynchronous motors IEC motors with squirrel-cage rotor

including r installations. Backed by the worldwide l provide the reliabi Prime LEHE1073

SINGLE PHASE TEFC CAGE MOTORS

PAB Atex-certified centrifugal pumps

STANDBY 2860 ekw 3575 kva 50 Hz 1000 rpm

A.C. Motor for Railway. Auxiliary Application

A product of Coel Motori Srl, Milano, Italy

General Purpose Energy Efficient Induction Motors series 2SIE

BROCHURE. IE4 SynRM motor-drive packages Super premium efficiency for industry

Transcription:

EU Regulation for Premium Efficiency IE3 motors 2, 4, 6 poles efficienza Regulations (EC) 640/2009 and 04/2014 establish the conditions for the conversion to the new energy-efficient technology as requested by the EU MEPS Directive (European Minimum Energy Performance Standard). Standard IEC 60034-30 defines the energy efficiency classes for asynchronous motors. From January 1, 2015: energy efficiency class IE3 is mandatory for single speed three phase induction motors in the range 7.5 kw to 375 kw, 2, 4, 6 poles, rated voltage up to 1000 V, continuous duty operation S1 that are connected direct online. IE2 motors can still be placed on the market but they need to be used with a VSD (variable speed drive). Which kind of motors are covered by the Regulation? Three phase asynchronous motors 7.5 kw - 375 kw / 2, 4, 6 poles, continuous duty operation S1 Three phase asynchronous motors with auxiliary devices (shaft seal, speed sensors, etc...) 7.5 kw - 375 kw / 2, 4, 6 poles, continuous duty operation S1 Motors with rated power below 7.5 kw Motors specially designed for operation in discontinuous duty operation (e.g.: S3 < 80%) Motors fed by a variable speed drive VSD - Inverter * Motors with servo-ventilation Motors for gearmotors, pumps, fans, compressors, where the motor s efficiency can be tested independently from the machine Motors that are fully integrated into a machine where the motor s efficiency cannot be tested independently from the machine Motors completely immersed in a liquid during operation Potentially explosive atmospheres ATEX motors Brake motors Motors specially designed for operation at altitudes not exceeding 4000 m ASL Motors specially designed for operation where ambient temperature is less than 60 C Motors specially designed for operation where maximum working temperature is less than 400 C Motors specially designed for operation where ambient air temperature exceedes -30 C for any motor or exceedes 0 C for a motor with water cooling Motors specially designed for operation where the water coolant temperature at the inlet of a product in the range 0 C to 32 C Other motor types (e.g.: permanent magnet motors, double pole motors, motors used with a frequency converter, ecc ) Rev.04 pag. 1

Placing of IE2 motors in the European market: IE2 motors still be placed on the European market after January 1, 2015 as long as they have been placed for the first time in the European market before December 31, 2014. In that case the final user can use IE2 motors as usual. From January 1, 2015 IE2 motors can be placed in the European market only if they are fed by a variable speed drive (VSD). Information about the obligation to use a VSD must be displayed on the rating plate or on an additional sticker/plate on the motor and in the motor s technical documentation. The final user is responsible to fit the IE2 motors with a VSD. * Note: motors fed by VSD placed on the European market must be IE2 or IE3. Exports out of the European market: The following are T case of placing products on the market in the sense of Directive 2009/125/EC and its implementing Regulations: If the product is exported from a manufacturer in a Member State to a third country outside the European market. If the product of a manufacturer is transferred to an exporter (dealer or manufacturer of machines) which then exports it outside the European market independently or as an integrated component. Rating plate marking: The Regulation allows marking of nominal efficiency at only 100% rated load in the case of small motors due to the limited size of their rating plates. The customer is responsible for ordering and start up the motor suitable to the conditions provided by the European Regulation. From January 1, 2017: energy efficiency class IE3 is mandatory for single speed three phase induction motors in the range 0.75 kw to 375 kw, 2, 4, 6 poles, rated voltage up to 1000 V, continuous duty operation S1 that are connected direct online. IE2 motors can still be placed on the market but they need to be used with a VSD (variable speed drive). Rev.04 pag. 2

HE3 motors: new range of IE3 motors Neri Motori offers a new range of motors, called HE3, efficiency class IE3 obtained by: Optimization of the winding design High performances material Reduction of the working temperature Loss reduction Friction reduction 6 poles motors available on request Rev.04 pag. 3

Dimensions: Rev.04 pag. 4

Rev.04 pag. 5 Sizes 180 / 200 available on request