Atlas Copco Generators

Similar documents
Atlas Copco Generators QAS kva 50 Hz dual frequency. For your peace of mind

Atlas Copco Portable Air compressors

Atlas Copco Portable Air compressors

Atlas Copco Portable Air compressors

THE POWER OF CONNECTIVITY QAS generators

WITHSTANDING THE ELEMENTS

XAS185 KD T4F Product Reference. Product Reference XAT(V)S 186 Jd Stage IV. Portable compressor. Standard Scope of Supply.

PRO Rental Product Range. PRO60-2 (R96 EUIIIa Equivalent) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR)

People. Passion. Performance. 60Hz Diesel Generators for Construction Applications

PRO Rental Product Range. PRO150-1 (Fuel Optimised) PRO150-2 (EUIIIa Compliant) KEY FEATURES. Alternator. Rental Ready Features

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

500 KW / 625 KVA POWERED by

Model name XATS 138 XAHS 108 Normal effective Working Pressure Bar(g) 7 8, Psi (g)

70 KW / 90 KVA POWERED by

HILIGHT RANGE. Your site. Your light.

PowerSource Generators. Product Range

THE VERSATILITY RANGE. Products for every site. Options for everyone. 5,2-23 m 3 /min (7-14 bar)

Rental Power. Power Modules up to 1250 kva can be customised to meet rental customer s exact requirements.

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

THE VERSATILITY RANGE. Products for every site. Options for everyone m 3 /min (7-14 bar)

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

KVAR POWERHOUSE RANGE 140 KVA 200 KVA

YOUR SITE. YOUR LIGHT

60 KW / 75 KVA POWERED by

1000 Series 1004G Diesel Engine ElectropaK Belt-Driven Coolant Pump

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

MORE THAN JUST POWER... FG WILSON INDIA KVA PRODUCT RANGE

THE READY TO GO RANGE. The 8 Series. What do you tow?

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

Alpha SERIES LWA 10(A)*, LWA 15(A), LWA 20(A), LWA 27(A) 50 Hz; 1500 r/min; power outputs: kva 60 Hz; 1800 r/min; power outputs:

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

400 Series 422TGM Marine Auxiliary Engine 30.3 kw (40.6 hp) gross prime 1800 rpm

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

28 KW / 28 KVA POWERED by

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

REOZM SERIES GENERATORS. for Industrial Power Systems 835 kva 2500 kva 668 kw 2000 kw

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

1100 Series 1103A-33TG2 Diesel Engine ElectropaK 67.5 kwm / rpm

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

KVA POWERHOUSE RANGE 1250 KVA 1700 KVA

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

57 KW / 71 KVA POWERED by

55 KW / 69 KVA POWERED by

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Voltage kva kw kva kw Amp 400/ ,00 388,00 425,00 340,00 613,00 OTHER ACCESSORIES

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

1100 Series 1104A-44TG1 Diesel Engine ElectropaK 75.5 kwm / rpm

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

ATLAS COPCO WEDA RANGE PUMPS. Pumps for professionals 50Hz

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

POWER WITHOUT COMPROMISE

Better Soundproof, Better Life!

Atlas Copco WEDA Line Pumps (50 Hz) Pumps for professionals

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

JCB Diesel Generator Technical Specifications G31RX. Electrical. Prime

LWALR LIQUID COOLED LONG RUNNING GENSETS

Your site. Your light

JCB Diesel Generator Technical Specifications G331QX. Electrical. Prime

C14 -C30. Portable Air Compressors. Intelligent Air Technology

1000 KW / 1250 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DRILLAIR Y35 / X28. for geothermal, waterwell and foundation drilling

4000 Series TAG3 ElectropaK rpm net standby power

Atlas Copco WEDA Line Pumps (50 Hz) Pumps for professionals

Power Factor Factor Cos = 0.8. Prime Power Standby Power Rated Current Fuel Consumption (PRP) (ESP) Amps

80 KW / 100 KVA POWERED by

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

power moving forward KVA RANGE Performance I Durability I Serviceability

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

Designed for Today s World

Designed for Today s World

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Reliable fuel effi cient engines. Energy effi cient compressor rotor design built to close engineering tolerances.

45 KW / 55 KVA POWERED by

RENTAL DIESEL GENERATOR SET

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

1800 KW / 2250 KVA POWERED by

1100 Series 4.4TW2GM Marine Auxiliary Engine kw (143.2 hp) gross prime 1800 rpm

C160TS-12 C230TS -9. Portable Air Compressors. Intelligent Air Technology

ELECTRIC SUBMERSIBLE DEWATERING PUMPS

Super Silent, Superior Life!

JCB Diesel Generator Technical Specifications G45QX. Electrical. Prime

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

Ingersoll Rand PowerSource Specification. Engine data. Alternator data. Fuel consumption. Ingersoll Rand

Atlas Copco. Oil-injected rotary screw compressors G ( kw / hp)

Sound Proof Diesel Generator. Welders

Atlas Copco Oil-injected Rotary Screw Compressors. G kw / hp

Atlas Copco WEDA Line Pumps (60 Hz) Pumps for professionals

NORTHSTAR. Power Systems NSPS 100 ENGINE KEY FEATURE GENERATOR CONTROLS STANDBY RATING: ALTERNATOR TYPE:

TPD2250H6.3 TECHNICAL DATA

4000 Series TAG4 Diesel Engine ElectropaK rpm net standby power

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

2800 Series 2806C-E18TAG1A Diesel Engine ElectropaK 598 kwm at 1800 rpm

Transcription:

Atlas Copco Generators QAS 14-100 Environmental friendly package purpose built to go anywhere Team-up for Total Solutions

QAS Generators A complete range comprising the QAS 14, QAS 20, QAS 30, QAS 45, QAS 60, QAS 80 and QAS 100 models. The QAS range is powered by the Perkins 400 and 1100 Series engines and are equipped with Newage-Stamford alternators. A wide range of available options allow you to customize your QAS generator according to your needs. The Products and Features you asked for As part of a continual product developing process, our designers and engineers have talked with and visited many of our customers. Their findings have been turned into a product concept that is uniquely super-silenced, smooth running, and clean to operate. Protect your investment A new design, excellent build quality, new safety features and the introduction of state-of-the-art technology allowing remote control and monitoring will guarantee that your investment is well protected. Our environmental approach to design and manufacturing resulted in a super-silenced canopy, effectively reducing noise levels to well below actual and future requirements of European regulations. QAS generators are designed with reliability, durability, seviceability and low-cost of ownership as main design drivers, ensuring your QAS generator retains a high residual value, even after many years of heavy duty. Durability The canopy is zincor treated, with a powder coat paint finish for durability and excellent resistance to corrosion. The generator canopy is extremely robust and solid and is directly mounted on the base frame. QAS generators are purpose designed and built to withstand the rough on-site handling and are suitable for use in demanding environments and conditions. The canopy is fully lockable with a common key for extra safety and security. The QAS generator looks good for longer.

offering everything you asked for High capacity fuel filter/waterseparator is installed as standard which protects the engine and extend the life-time of the generator. An adjustable earth leakage detection will protect the operator and the downstream equipment. The two stage heavy duty air filter with safety cartridge is located within the generator enclosure. A filter indicator will inform when the air filter should be cleaned or replaced. QAS generators are well balanced so the units can be safely lifted by crane. Benefits for our environment Respect for the environment is of paramount importance to Atlas Copco. Our design and manufacturing approach, and the different features attest to this fact. There is a standard sealed spillage free base frame, ensuring that any spills are contained inside the enclosure. The Perkins engines fully comply with the EPA Tier II, EC Stage 2 and TA Luft exhaust emission legislations. Our super silenced canopies offer better than current (and future OND 2006) EU regulations with sound levels between 60-68 db(a).

The QAS generators are powered by the 400 and 1100 Series Perkins engines. These engines are designed with the demanding customer in mind: they are compact, powerful, reliable, cost effective, quiet and clean in operation. Designed with the operator in mind QAS generators are easy and safe to manoeuvre. The robust steel skid incorporates two forklift slots and tie down points. The wider skid protect the canopy while moving the unit with a forklift. The generator can also be safely lifted by means of the lifting beam. Wide opening doors and easy removable panels offer excellent accessibility to all components. All components which need to be serviced are centralized at one side of the generator. All key operating functions can be supervised without opening the canopy. The comprehensive control panel is covered by a tough transparent cover that provides protection from humidity and unauthorized access. The lockable fuel filler cap is recessed and can be easily reached to top up the generator. Cost of Ownership The cost of ownership has been pushed as low as possible. Fuel and oil consumption has been significantly improved. Service intervals have doubled to 500 hours and the time taken to complete a service has also been reduced with the single side servicing. Trouble-free operation is guaranteed with the standard fit high capacity fuel filter/water separator. The two -stage heavy-duty air filter extends the life of the filter and is equipped with a safety cartridge to allow air filter change or cleaning even whilst the generator is running. The QAS generators are equipped with the synchronous brushless type Newage-Stamford alternators. The BC alternators are equipped with auxiliary windings and the UC are equipped with PMG, both offer excellent start up and good short circuit capability. Safety An adjustable earth leakage protection protects the operator and the downstream equipment. The design of the quick fix electrical connections eliminates the risk of accidental contact. Sockets, door handles and the fuel filler are recessed to avoid damage and injuries to third parties. The emergency stop push button is recessed to prevent damage, but is in easy reach without opening the main unit door.

Technical Data Performance data (1) Type QAS 14 QAS 20 QAS 30 QAS 45 QAS 60 QAS 80 QAS 100 Rated speed r/min 1500 1500 1500 1500 1500 1500 1500 Rated power factor ( lagging ) 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Rated Prime power kva 13 20 30 45 60 80 100 Rated Standby power kva 14 22 33 50 66 88 110 Rated Voltage Line to line V 400 400 400 400 400 400 400 Rated Current A 18 28 43 65 87 116 144 Maximum sound power level (LWA) according to 2000/14/EC OND Maximum sound pressure level at 7m and 75% load db(a) 85 87 89 88 90 89 93 db(a) 60 62 64 63 65 64 68 Basic unit Fuel autonomy at full load h 13 9 21 14 11 10 8 Capacity fuel tank l 45 45 135 135 135 170 170 With optional skid fuel tank Fuel autonomy at full load h 93 66 51 47 37 35 29 Capacity fuel tank l 315 315 460 460 460 571 571 Fuel consumption 100% load l/h 3.2 4.7 6.4 9.7 12.5 16.4 21.8 75% load l/h 2.7 3.6 5.2 7.9 9.6 12.4 16.5 50% load l/h 1.9 2.7 3.7 5.9 6.8 8.8 11.9 Design data Alternator Make Newage Newage Newage Newage Newage Newage Newage Insulation ( rotor & stator ) class H H H H H H H Degree of protection IP 23 23 23 23 23 23 23 Engine Make Perkins Perkins Perkins Perkins Perkins Perkins Perkins Model 403C-15 404C-22 1103A-33G2 1103A-33TG1 1103A-33TG2 1104A-44TG2 1104C-44TAG2 Rated net power kw 12 18.5 27 41.3 59.3 71.9 89 Number of cylinders 3 4 3 3 3 4 4 Bore mm 84 84 105 105 105 105 105 Stroke mm 90 100 127 127 127 127 127 Displacement l 1.5 2.2 3.3 3.3 3.3 4.4 4.4 Unit dimensions ( Basic unit ) QAS 14 QAS 20 QAS 30 QAS 45 QAS 60 QAS 80 QAS 100 Length m 2.07 2.07 2.45 2.45 2.45 2.94 2.94 Width m 1.00 1.00 1.10 1.10 1.10 1.10 1.10 Height m 1.18 1.18 1.48 1.48 1.48 1.50 1.50 Weight ( dry ) kg 921 946 1352 1454 1456 1699 1810 Weight ( ready to operate ) kg 969 994 1460 1547 1566 1854 1960 Unit dimensions ( with Optional skid fuel tank ) Length m 2.07 2.07 2.45 2.45 2.45 2.94 2.94 Width m 1.00 1.00 1.10 1.10 1.10 1.10 1.10 Height m 1.47 1.47 1.77 1.77 1.77 1.78 1.78 Weight ( dry ) kg 1098 1123 1577 1679 1681 2129 2645 Weight ( ready to operate ) kg 1281 1306 1999 2086 2105 2240 2756 Unit dimensions ( with Optional undercarriage ) Length m 3.58/3.75 3.55/3.71 TBA TBA TBA TBA TBA Width m 1.41 1.41 TBA TBA TBA TBA TBA Height m 1.51 1.51 TBA TBA TBA TBA TBA Weight ( dry ) kg 1017 1042 TBA TBA TBA TBA TBA Weight ( ready to operate ) kg 1065 1090 TBA TBA TBA TBA TBA Built and tested to ISO 9001 quality assurance standards Atlas Copco s stringent manufacturing standards follow ISO 9001 quality assurance regulations. All components are produced and tested to exacting standards for optimum performance in the most demanding conditions. (1) Reference condition: For engine performance to ISO 3046/1-1995 Standard reference conditions are: 27 C air inlet temperature. 150m above sea level.

Options QAS generators can be supplied with external fuel tank connections. Fuel feed and returns pass through 3-way valves (operated by one handle) and allows to change over from the internal fuel tank to an external bulk tank. The QAS generator can be equipped with an over-speed shutdown valve. Spark arresting silencer can be installed inside the generator enclosure. Customised colour For other special colour configurations please contact your local Atlas Copco Customer Centre. QAS generators can be supplied with an optional skid fuel tank which can easily be fitted between the base frame and the skid. All fuel lines are internally and makes the generator tamperproof. The external fuel filler remains. This option results in a fuel autonomy of between 29 93 hours depending on the model.

Options The Qc1001 is our basic control panel, it adjusts and monitors all operations and can be controlled from a remote distance. The Qc4001 is our advanced control panel, amongst other features it allows for synchronisation between multiple generators or with the mains. The terminal board allows customers to adapt the output to their specific requirements combined with a difference on sockets. QAS 14 20 with lighting tower. Essential light for professional players See also our separate Lighting tower sales leaflet.

Options - Matrix Electrical Options QAS 14 QAS 20 QAS 30 QAS 45 QAS 60 QAS 80 QAS 100 Adjustable earth leakage detection QAS generators can be supplied with a coolant heater to ensure that the generator will be available at any time when needed. Battery conditioner Battery isolator Coolant heater Dual frequency ( 50 & 60 Hz ) Electronic governor Insulation monitoring relay Qc1001 - Local & Remote start Qc3001 - Automatic start Qc4001 - Synchronising 230V 1-phase 230V 3-phase 400V 3-phase Multi-voltage with selector switch Sockets ( only ) Terminal board ( only ) Terminal board with EDF Neutral Terminal board with sockets Lighting towers ( road & off road ) Change over contactor kits Mechanical Options QAS 14 QAS 20 QAS 30 QAS 45 QAS 60 QAS 80 QAS 100 External fuel tank connections ( quick couplings ) A battery isolator switch allows to switch- off the battery when carrying out maintenance or when needed Overspeed valve Spark arrestor Refinery equipment ( overspeed valve & spark arrestor ) Road trailer ( adjustable with brakes ) Standard Option Not available 24 Volt adapter Ball coupling ( loose ) Different towing eyes Optional skid fuel tank Customised colour ( one canopy color & special color ) Additional literature set

We care about the environment BE C A U SE W E C A RE Atlas Copco believes in doing business in a manner that preserves the environment for future generations. So even as legislation for environmental protection gets tougher each and every year, Atlas Copco meets and often surpasses those benchmarks. The products are not only designed to operate with the environment in mind, but the way they are manufactured is as important: - to prevent any kind of oil, coolant or fuel pollution - spillage free frames are available on all models. - environmentally friendly materials are used that are not only less energy consuming to make, but recyclable as well. As a company, we take our engagements seriously, and to this end have obtained and maintained the ISO 14001 certification: - that proves that we implement, maintain and improve our own environmental management systems. - that ensures conformance to our own stated standards and policies in the matter. - that ensures compliance with environmental laws and regulations. The environment - today and for future generations - is a top priority for our company. We aim to set the standards by which others will be judged. And we aim to maintain those standards for many years to come. All QAS generators meet current European and US legal requirements, or are even better, relating to the working environment and regulations concerning safety, exhaust emissions and noise. The Super-silenced design makes QAS generators very suitable for operation in noise sensitive environments even during the night.

Safeguarding your investment and your peace of mind The availability, quality and maintenance of your generator has a direct effect on your production performance and ultimately affects your bottom line. Irregular, insufficient or unprofessional maintenance can result in expensive downtime with a subsequent loss of production, affecting your profitability and damaging your reputation. Atlas Copco carefully monitors the maintenance needs of all its generators. Service intervals are established to ensure optimum performance is maintained and operating costs reduced. Proper maintenance will ensure your generator runs as efficiently and economically as possible. Atlas Copco has compiled a portfolio of aftermarket services that guarantee the protection of your investment and provide the highest quality service, both locally and worldwide. Depending on your requirements, we can deliver parts kits, cover your individual service calls or provide a range of service plans, all tailored to suit your needs. Genuine Parts Atlas Copco makes no compromise on the quality of replacement parts: only genuine parts provide the longevity and reliability you require. Selected high quality Atlas Copco engine oils are also available. These meet the stringent quality specifications required to enable your unit to run smoothly, shift after shift. ServicePlan For complete peace of mind, Atlas Copco has a range of service agreements to suit your needs. Maintenance budgets are clear and simple, with prices fixed in advance. Operational costs come down and efficiency goes up. You choose the service options and the time period to suit your needs. Commitment The entire unit is guaranteed from any defects for a full 12 months from the date of start-up irrespective of number of hours of operation. In addition to that, the entire generator assembly, the voltage regulator and voltage changeover switch are guaranteed a full 24 months from the date of start-up. Some restrictions do apply as it relates to hours of operation, and specifics may vary for the different motors used. 2935 0622 30 - Subject to modifications without prior notice. Printed in Belgium. Copyright 2005, Atlas Copco Airpower n.v., Wilrijk, Belgium. Use only authorized parts. Warranty or Product Liability does not cover any damage or malfunction caused by the use of unauthorized parts. Visit our website: www.atlascopco.com