For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

Similar documents
Manually or pneumatically actuated Piston pumps

Compact Units. For fluid grease, NLGI grades 000, 00 Group MKF 0.1 or 0.2 l/min EN

Manually or pneumatically actuated piston pumps

Accessories for Minimal Quantity Metering

" " (495) For oil For continuous monitored lubrication with minimum quantities from 0,5 to 5 mm³/min

Product series DSA, DSB, DSC, DSD

Injection oilers, micro pumps for minimal quantity metering

Motor-driven pump unit GSJB

Flow Monitors and Sensors

Single-Line Centralized Lubrication Systems

Inexpensive solution for the lubrication of linear guides and rolling bearings

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

For grease For application in SKF DuoFlex dual-line centralized lubrication systems

Grease Pump Units. For progressive and multiline systems, manually, pneumatically or hydraulically actuated. Please note!

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

SKF Multilube pumping unit

Injection oilers, micro pumps

Electric Plug-and-Socket Connectors

Block feeder SPVS Used in oil or grease lubrication systems

Block feeder SPVS Used in oil or grease lubrication systems

Directional Valves for oil or grease

Metering Units and Piston Distributors with Quick Connector System

for SKF DuoFlex dual-line lubrication systems

Chain lubrication, accessories Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication EN

SGA and SG-dosers. for SKF DuoFlex dual-line lubrication systems

Piston Distributors, Metering Units

Linear actuator CAR 32. Benefits. Industrial reliable and robust actuator Wide range of components Right- and left-hand version

Piston Pumps with Reservoir

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

SKF Maxilube pumping centre. for SKF DuoFlex, dual-line lubrication systems

Injection Oilers, Micro Pumps

Chain lubrication, accessories

Grease Lubrication Pump FK

P653S Centro-Matic oil pump

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Gear pump unit with reservoir for use in centralized lubrication systems

SKF Multilube pumping unit. for single-, dual-line and progressive lubrication systems

SP/SMT 1 Flow Divider

Linear actuator CAT 33. Benefits. Small Robust Highly efficient Lubricated for service life Digital encoder feedback

SKF VectoLub, accessories Accessories for the minimal quantity lubrication systems VTEC and VE1B EN

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

UD and UC Gear pump unit

SKF Belt Tension System. The SKF way to support transmission Easy Quick Repeatable

Lubrication System CLU4

Lubrication System CLU4

Flow limiter SP/SMB3 Flow limiter SP/SMB6

SKF VectoLub, VE1B units

SKF Energy Efficient double row angular contact ball bearings. Reduced friction for reduced energy use

SKF Oil+Air Lubrication Units and Mixing Valves Product Series OLA, MV and 161

SKF Explorer cylindrical roller bearings. Extended range for large, heavy industrial applications

SKF Grease injection system

Product Series OLA, MV and 161

Single- and Multicircuit Pumps

Flow limiter SP/SMB10 Dual flow series

Flow limiter SP/SMB9 for mounting plates

For reliable control of small, large or multi-system-type lubrication systems

Reservoir pump units of the KGF series (S) (C) for use in vehicles in automatic oil or grease lubrication systems

JM Oil Lubrication Pump SKF MultiFlex multi-line pump units for total loss oil lubrication systems on compressors

lubrication systems CME Electric pump for oil and soft grease volumetric

Grease-lubricating pump FF... DSK US (05.05)

Fittings and Accessories. For oil and grease. For Centralized Lubrication Systems and General Use

SKF Flowline. for circulating oil lubrication systems

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

Maximizing performance. Radial shaft seals HMS5 and HMSA10 Longer service life Improved sealing performance Excellent oil compatibility

Lubrication systems for agricultural machines

KFG; KFGS; KFGL; KFGC (CAN bus) for vehicle lubrication

Bearing designs. Spherical roller bearings. Extract from the Railway technical handbook, volume 1, chapter 4, page 96 to 98

SKF, the market leader for gas spring seals

SKF Super-precision Bearing Lubrication Unit. Improved reliability, profitability and reduced environmental impact

SKF ConCentra roller bearing units. The fast, easy, error-free way to install and remove plummer blocks

Electronic lube meter

Air-oil centralized lubrication systems

SKF fan upgrade services. One source for a full range of solutions, from unique bearing systems to circulating oil lubrication systems

Special industrial solutions. SKF custom-engineered bearings and bearing units

Application List for SKF Linear Ball Bearings

Product series DigitalSuper

Oil + Air-Lubrication System for lubrication of spindles, linear guides, rack pinions, chains and assembly processes

Chain lubrication, accessories

DUOFLEX lubrication pumps

Compact Units for Oil

Fittings and Accessories. for Centralized Lubrication Systems and General Use

Lubrication equipment solutions for vehicle service professionals. Helping maintain and sustain vehicle service facilities

Lubrication solutions for the rail industry

PRA Centrifugal pumps

SKF solutions for CNC turning centres

Air-oil centralized lubrication systems

Wall mount PMV pump with suction kits and hoses

SKF Energy Efficient deep groove ball bearings. Reduced friction for reduced energy use

Electric pump EP-1. Electric pump with 1.9 kg reservoir:

Centralized Lubrication Systems for Commercial Vehicles

SKF SEAL JET. NG 025 / NG 040 / NG 060 machines

SKF EasyRail. Intelligent mobile centralized lubrication systems for wheel flange lubrication and top of rail conditioning

SKF hub units. Equipped with tapered roller bearings

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

Relubrication-free solutions for industrial air handling units. Easy to install Long service life Relubrication-free Reduced power consumption

KFG; KFGS; KFGC (CAN bus) for vehicle lubrication

PS/PSL Centrifugal pumps

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

Transcription:

Gear pump unit roduct series KFB For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems SKF gear pump units of the KFB product series are used to supply lubricant to SKF MonoFlex single-line systems. They are designed for use on commercial vehicles, systems, and machines. The commercial vehicle version has type approval pursuant to ECE-R 10. SKF gear pump units of the KFB product series are designed for the supply of fluid grease of NLGI grades 000 and 00. They include a pressure-relief valve and a pressure-limiting valve for the operation of intermittently operated MonoFlex single-line systems. The distribution and metering of the lubricant to the lubrication point can be accomplished using SKF MonoFlex singleline distributors. The gear pump units are designed for supply voltages of 1 V DC and V DC. They are controlled either by a built-in electronic control unit or externally, via the machine control system. An optional fill level switch can be selected to monitor the fill level. Depending on the design, the gear pump units are filled via a filler socket or an attached filler coupling. Their compact design makes gear pump units of the KFB product series the ideal solution for the assembly of small centralized lubrication systems on commercial vehicles and machines with few lubrication points.

roduct series KFB roduct overview KFB1 KFBS1 with integrated control KFBS1-6-S1 with VN relubrication distributor KFB1-M-W KFBS1-M-W with integrated control KFB1-M-W-S1 SKF gear pump units of the KFB product series differ principally in their options for electrical connection and in control and function monitoring. The pump casing contains the mounting flange, the mounting plate for the hydraulic connections, the electrical connection, and in the case of controlled models, also the display screen of the electronic control unit built into the pump casing. Gear pump units of the KFB1 group are not controlled and therefore do not contain a built-in control unit. Gear pump units of the KFBS1 group contain an integrated electronic control unit that can be programmed via the display screen on the front of the pump casing. The electronic control unit regulates the functions of the gear pump unit and monitors the fill level. If available, an external pressure switch can also be integrated into the monitoring system. The mounting plate for the hydraulic connections includes the pressure-limiting valve, the pressure-relief valve, and the lubrication line connection. For models with a follower piston, there is always a filler coupling fitted on the mounting plate for filling the lubricant reservoir. With models without a follower piston, the lubricant reservoir can also be filled directly through a filler socket on the reservoir surface. The lubricant reservoir is mounted on the pump casing and is made of transparent plastic with markings for visual monitoring of the fill level. Models with automatic fill level monitoring contain a fill level switch as well, which is either separate in the lubricant reservoir or acts together with the follower piston to issue a signal when the lubricant level is too low. Gear pump units in the KFB1 group are fitted with a pushbutton on the pump casing for triggering interim lubrication. On gear pump units of the KFBS1 group (controlled), interim lubrication is triggered via the electronic control unit's display screen. UB LS/ 1658 EN 1-106-EN

roduct series KFB roduct selection table Vehicle application 1) for 1 or V DC Lubricant Electrical connections Fluid grease Fill level Circular connector Circular connector Order No. NLGI grade 000, 00 Control unit switch AM, -pin AM, 7-pin Design age KFB1 ) Basic version KFB1-W ) Basic version KFBS1 ) Basic version KFBS1-W ) Basic version KFB1--S1 ) VN distributor KFBS1--S1 ) -port KFB1-6-S1 ) VN distributor KFBS1-6-S1 ) 6-port KFB1-W--S1 ) VN distributor KFBS1-W--S1 ) -port KFB1-W-6-S1 ) VN distributor 6-port KFBS1-W-6-S1 ) 1) All units for vehicle applications have type approval pursuant to ECE-R 10. ) When ordering, quote the code for voltage to be used 1 V DC: Order code +91 V DC: Order code +9 Industrial application for V DC Lubricant Oil Fluid grease Electrical connections Order No. Viscosity NLGI grade Fill level Square connector Circular connector 50 50000 mm²/s 000, 00 Control unit switch -pin +E M1 1, -pin Design age KFB1-M+9 Basic version 6 KFBS1-M+9 Basic version 6 KFB1-M-W+9 Basic version 6 KFBS1-M-W+9 Basic version 6 KFB1-M-W-S1+9 Basic version 8 UB LS/ 1658 EN 1-106-EN CAUTION The important information on product usage located on the back cover applies to all systems described in this brochure.

roduct series KFB(S)1 Commercial vehicle applications KFBS1 KFBS1-6-S1 Technical data Units KFB(S)1, KFB(S)1-W, KFB(S)1--S1, KFB(S)1-W--S1, KFB(S)1-6-S1, KFB(S)1-W-6-S1 Fill level switch (for KFB(S)1-W) (opens when fill level too low) Switching voltage range........ 10 to 6 V DC Reservoir capacity KFB(S)1-W....1 liter Switching current (resistive load) )... 0.5 A Reservoir capacity KFB(S)1......1. liters Switching capacity (resistive load) ).. 1 W Delivery rate 1)............50 cm³/min Max. operating pressure.......8 bar Relubrication distributor VN (KFB(S)1(-W)-S1, KFB(S)1(-W)-6-S1) Operating temperature........ 5 to +75 C Lubrication point connection.....ush-to-connect fitting for tube ø rotection class according to Metered quantity........... 0.1; 0.; 0. cm³ DIN 0050 T9............. I6K6K / I6K9K Feeder body.............. Die-cast zinc, black corrosion Number of outlets........... 1 protection Lubricant............... Fluid grease of NLGI grade 000 or 00 Control unit IG50--I (KFBS1) Interval, adjustable.......... 0.1... 99.9 h Connected load............ See diagram 1 ump run time, adjustable......0.1... 99.9 min Main line...............ø 10 1.5; max. 16 m see diagram Max. pump run time..........0 min ) Elapsed-hours counter........ 0... 99999.9 h DC motor Fault-hours counter.......... 0... 99999.9 h Rated voltage............. 1 V V Rated current..............8 A 1.7 A Additional input power for units with Rated output............. 6 W 1 W control unit (without output load)......... W Operating mode acc. to DIN EN 600-1 (VDE 050-1) )... S,.5% (10 to 10 min) 1) At back pressure of 10 bar and a temperature of +5 C. ) The operating mode S (periodic duty) describes the ratio of pump run time to subsequent down time. If the relative ON-time is.5% and the duty cycle time is 10 to 10 min., then the limit values are as follows: Min. duty cycle time: 10 min 0.05 = 0.5 min. pump run time with subsequent down time of 9.75 min. Max. duty cycle time: 10 min 0.05 = min. pump run time with subsequent down time of 117 min. ) When switching inductive loads, take appropriate measures to protect contacts. Diagram 1 Fixing diagram Max. connected load / max. main line length for fluid grease of NLGI grades 000, 00 Drilling template Main line [m] 16 1 1 10 8 6 1 Range of application max.-15 C max.-5 C 1 5 6 7 8 9 10 11 1 1 1 15 16 17 Connected load of distributor [cm³] ø0. M8 100 UB LS/ 1658 EN 1-106-EN

roduct series KFB(S)1 Assembly drawing KFBS1 with control KFB1-W--S1 with pre-assembled VN relubrication distributor KFB1: X1 circular plug -pin for cable harness max ø9 10 5 Vent plug min 9 100 M16x1.5 1) 1 Filler socket ) 16 KFBS1: X1 circular plug, 7-pin for cable harness 1) Connection thread countersunk for solderless tube union for tube ø 10 mm. ) Coupling socket for filler socket, order no. 995-001-500 (must be ordered separately). KFB1: pushbutton 70 ~0 Metered quantity 1 ush-to-connect fitting connection for tube ø VN relubrication distributor, -port Hydraulic layout KFB1 1 Terminal diagram 1 X1 circular plug -pin Cable harness 997-000-706 (not included in delivery) KFB1, KFB1--S1, KFB1-6-S1 X1 1 F RD- 1) + M DK M1 BN ) K Not used Key to terminal diagrams 1 15 = + Supply voltage potential (ignition ON) 1 = Supply voltage potential (0 V, ground) X1 = lug-in connection -pin or 7-pin DK = ushbutton WS = Fill level switch, contacts shown for full reservoir DS = ressure switch (external) SL1 = Indicator light pump ON SL = Indicator light malfunction F = Fuse protection to ISO 880 for V DC: A for 1 V DC: 5 A 1) = External control, relay contact pump ON ) = in without internal connection 15 1 UB LS/ 1658 EN 1-106-EN Hydraulic layout KFBS1-W 5 6 1 7 X1 1 BN F 1) 1 15 + M DK M1 5 6 7 ) ) RD- BU Q WS K + OK VT-GN Not used X1 1 BN F RD- 1 15 Terminal diagram X1 circular plug7-pin Cable harness 997-000-90, cable harness with corrugated tube 997-000-60 or 997-000-650 (not included in delivery) KFB1-W KFB1-W--S1 KFB1-W-6-S1 KFBS1(-W) KFBS1(-W)--S1 KFBS1(-W)-6-S1 BU K 5 DK SL DS SL1 +.W.W 6 7 VT-GN 5

roduct series KFB(S)1-M (-W) Industrial applications KFB1-M-W KFBS1-M-W Technical data Units KFB1-M, KFB1-M-W, KFBS1-M, KFBS1-M-W Reservoir capacity KFB1-M...... 1. liters Fill level switch (KFB1-M-W) (changeover contact) Reservoir capacity KFB(S)1-M(-W). 1 liter Switching voltage range........ V DC ) Delivery rate 1)............. 50 cm³/min Switching current (resistive load) )... 0.5 A Max. operating pressure.......8 bar Switching capacity (resistive load) ).. 1 W Operating temperature........ 0 to +60 C rotection class according to Control unit IG50--I (KFBS1) DIN EN 6059 (VDE 070-1)..... I65 Interval, adjustable.......... 0.1... 99.9 h Operating mode acc. to ump run time, adjustable......0.1... 99.9 min DIN EN 600-1 (VDE 050-1) )... S, % (6.5 to 60 min) Max. pump run time.......... min Elapsed-hours counter........ 0... 99999.9 h Number of outlets........... 1 Fault-hours counter.......... 0... 99999.9 h Lubricant............... Fluid grease of NLGI grade 000 or 00 Main line...............ø 8 1.5; max. 16 m DC motor Rated voltage............. V DC ) Rated current............. 1.7 A Rated output............. 1 W Additional input power for units with control unit (without output load)......... W 1) At back pressure of 10 bar and a temperature of +5 C. ) The operating mode S (periodic duty) describes the ratio of pump run time to subsequent down time. If the relative ON-time is % and the duty cycle time is 6.5 to 60 min., then the limit values are as follows: Min. duty cycle time: 6.5 min 0.0 = 0.5 min. pump run time with subsequent down time of 6 min. Max. duty cycle time: 60 min 0.0 =. min. pump run time with subsequent down time of 57.6 min. ) Safety measures to be applied for correct operation: rotective extra-low voltage (ELV), standards: EN 600-1/IEC 600-1; HD 606--1/DIN EN 0100-10/IEC 606--1. ) When switching inductive loads, take appropriate measures to protect contacts. UB LS/ 1658 EN 1-106-EN 6

roduct series KFB(S)1-M (-W) KFB1 without control KFBS1 with control ø9 X1 cable socket DIN EN 17501-80 A, can be pivoted 90 Vent plug 10 100 M1x1.5 1) 5 Filler socket ) 16 Control unit display screen M1x1 KFBS1-M(-W): X circular plug for pressure switch KFB1-M-W: X circular plug for fill level switch 1) Connection thread countersunk for solderless tube union for tube ø 8 mm. ) Coupling socket for filler socket, order no. 995-001-500 (must be ordered separately). For corresponding fixing diagram, see page. KFB1-M KFBS1-M-W Key to terminal diagrams L+ = Supply voltage potential (machine switch ON) M = Supply voltage potential (0 V) X1 = Supply voltage plug-in connection X = lug-in connection for pressure switch fill level switch M1 = ump motor WS = Fill level switch, contacts shown for full reservoir DS = ressure switch SL = Indicator light malfunction F = Fuse protection to DIN EN 6017- (VDE 080-) standard sheet for V DC: T.5 A 1) = External control, relay contact pump ON ) = in without internal connection Terminal diagram Terminal diagram X1 square connector -pin +E to DIN EN 17501-80 A KFB1-M, KFB1-M-W KFBS1-M, KFBS1-M-W X circular plug M1 1, -pin KFB1-M-W KFBS1-M, KFBS1-M-W UB LS/ 1658 EN 1-106-EN 1 + M M1 X1 1 ) ) 1) F L+ M (0V) X1 1 F L+ M (0V) ) SL.W 1 Q WS X 1 ) BN WH BU + Min. OK +V BN X 1 ) ) DS DS 7

roduct series KFB1-M-W-S1 Industrial applications KFB1-M-W-S1 Technical data KFB1-M-W-S1 unit Reservoir capacity..........1. liters Delivery rate 1)............. 1.6 cm³/min. Max. operating pressure.......8 bar Operating temperature........ 0 to +60 C rotection class according to DIN EN 6059 I65 (VDE 070-1)............. Operating mode acc. to DIN EN 600-1 S, 0% (1.5 to 50 min.) (VDE 050-1) )............ Number of outlets........... 1 Lubricant............... Oils n = 50 50000 mm²/s (cst) Fill level switch (opens when fill level too low) Switching voltage range........ 10 to 6 V DC ) Switching current (resistive load) ).. 0.5 A Switching capacity (resistive load) ).. 1 W DC motor Rated voltage............. V DC ) Rated current............. 0.5 A Starting current............ 1. A Rated output............. 11 W 1) At back pressure of 10 bar and a temperature of +5 C. ) The operating mode S (periodic duty) describes the ratio of pump run time to subsequent down time. If the relative ON-time is 0% and the duty cycle time is 1.5 to 50 min., then the limit values are as follows: Min. duty cycle time: 1.5 min. 0. = 0.5 min. pump run time with subsequent down time of 1 min. Max. duty cycle time: 50 min. 0. = 10 min. pump run time with subsequent down time of 0 min. ) Safety measures to be applied for correct operation: rotective extra-low voltage (ELV), standards: EN 600-1/IEC 600-1; HD 606--1/DIN EN 0100-10/IEC 606--1. ) When switching inductive loads, take appropriate measures to protect contacts. Terminal diagram 5 Key to terminal diagram 5 Square connector, -pin +E to DIN EN 17501-80 A X1 supply voltage X fill level monitoring 1 X1 1 ) F M M1 1) + ) Q WS X 1 ) + OK L+ = Supply voltage potential (machine switch ON) M = Supply voltage potential (0 V, GND) X1 = Supply voltage plug-in connection X = Fill level monitoring plug-in connection WS = Fill level switch: contacts shown for full reservoir F = Fuse protection to DIN EN 6017- (VDE 080-) standard sheet for V DC: T 0.6 A 1) = External control, relay contact pump ON ) = in without internal connection L+ M (0V) UB LS/ 1658 EN 1-106-EN 8

roduct series KFB1-M-W-S1 KFB1-M-W-S1 X square connector DIN EN 17501-80 A, can be pivoted 90 70 ø9 X1 cable socket DIN EN 17501-80 A, can be pivoted 90 10 Vent plug UB LS/ 1658 EN 1-106-EN 100 M1 1.5 1) 16 75 1) Connection thread countersunk for solderless tube union for tube ø 8 mm. For corresponding fixing diagram, see page. KFB1-M-W-S1 9

Accessories Electrical plug-in connections Topping-up pump for fluid grease Cable socket, -pin +E DIN EN 17501-80-A A Cable socket M1 1, -pin B C D E Electrical plug-in connections Fig. Description Order No. Topping-up pump Description Order No. A B C D E Cable socket, cable diameter 6 10 mm, -pin +E; max. 1.5 mm² Cable socket M1 1 straight, cable diameter 6 mm, -pin, max. 0.75 mm² Cable socket M1 1 straight, -pin with integrally extruded cable; 5 m, 0.5 mm²) Cable socket M1 1 angled, cable diameter 6 mm, -pin, max. 0.75 mm² Cable socket M1 1 angled, with integrally extruded cable, 5 m, 0.5 mm² 179-990-0 179-990-71 179-990-600 179-990-7 179-990-601 With moving gear For 5 kg drum 169-000-0 For 50 kg drum 169-000-05 Without moving gear For 5 kg drum 169-000- Associated filler socket 995-000-705 Capacity: ~0 cm³/stroke See also leaflet 1-170-EN Filler ressure switch Cap G 1 /A 10.5 SW 5 79 9 M10 1 tap Filler ressure switch Description Order No. Description Order No. Filler socket 995-000-705 Sealing ring DIN 760-A1x18-CU Coupling socket 995-001-500 Hose socket: ø1 mm 857-760-007 ø16 mm 857-870-00 See also leaflet 1-010-EN ressure switch 0 bar, DSD1-A000N-NOA11 NO-contact Cap 898-0-001 See also leaflet 1-1701-EN UB LS/ 1658 EN 1-106-EN 10

Accessories Main line connections Figure 7 Main line connections Item Description Order No. For plastic tubing 1 For steel tubing 5 6 6 7 7 For plastic and steel tubing 9 8 1 Reinforcing socket, tube ø6 06-60 Reinforcing socket, tube ø8 08-60 Reinforcing socket, tube ø10 10-60 Socket union, tube ø6 06-61 Socket union, tube ø8 08-61 Socket union, tube ø10 10-61 Tapered sleeve, tube ø6 06-611 Tapered sleeve, tube ø8 08-611 Tapered sleeve, tube ø10 10-611 Socket union, tube ø6 06-00 Socket union, tube ø8 08-0 Socket union, tube ø10 10-00 5 Double tapered ring, tube ø6 06-001 Double tapered ring, tube ø8 08-001 Double tapered ring, tube ø10 10-001 6 Sealing ring DIN760-A1 18-CU 7 Adapter, tube ø6 01-005 Adapter, tube ø8 01-001 Adapter, tube ø10 10-16 8 ush-to-connect fitting, tube ø6, straight 06-00-VS 9 ush-to-connect fitting, tube ø6, pivoted 506-10-VS See also leaflet 1-010-EN UB LS/ 1658 EN 1-106-EN 11

Seals Mechatronics Bearings and units Services Lubrication systems The ower of Knowledge Engineering Drawing on five areas of competence and application-specific expertise amassed over more than 100 years, SKF brings innovative solutions to OEMs and production facilities in every major industry worldwide. These five competence areas include bearings and units, seals, lubrication systems, mechatronics (combining mechanics and electronics into intelligent systems), and a wide range of services, from -D computer modelling to advanced condition monitoring and reliability and asset management systems. A global presence provides SKF customers uniform quality standards and worldwide product availability. Important information on product usage! All products from SKF may be used only for their intended purpose as described in this brochure and the operating instructions. If operating instructions are supplied together with the products, they must be read and followed. Not all lubricants can be fed using centralized lubrication systems. SKF can, on request, inspect the feedability of the lubricant selected by the user in centralized lubrication systems. Lubrication systems and their components manufactured by SKF are not approved for use in conjunction with gases, liquefied gases, pressurized gases in solution, vapors or such fluids whose vapor pressure exceeds normal atmospheric pressure (1 01 mbar) by more than 0,5 bar at their maximum permissible temperature. In particular, we call your attention to the fact that hazardous materials of any kind, especially the materials classified as hazardous by EC Directive 67/58/EEC, Article, ara., may only be filled into SKF centralized lubrication systems and components and delivered and/or distributed with the same after consultation with and written approval from SKF. Further brochures: 1-010-EN 1-1701-EN 1-901-EN 1-90-EN Fittings and accessories ressure switches, product series DSA, DSB, DSC, DSD Feeding lubricants with centralized lubrication systems Single-line systems for commercial vehicles SKF Lubrication Systems Germany GmbH lant Berlin Motzener Str. 5/7 177 Berlin O Box 970 170 Berlin Germany This brochure was presented to you by: Tel. +9 (0)0 700-0 Fax +9 (0)0 700-111 SKF is a registered trademark of the SKF Group. SKF Group 01 The contents of this publication are the copyright of the publisher and may not be reproduced (even extracts) unless prior written permission is granted. Every care has been taken to ensure the accuracy of the information contained in this publication. However, no liability can be accepted for any loss or damage whether direct, indirect or consequential, arising out of use of the information contained herein. UB LS/ 1658 EN July 01 1-106-EN skf.com/lubrication