FM, CSA, ATEX, IECEx CERTIFIED

Similar documents
INTERNATIONAL METAL ENGINEERING

INTERNATIONAL METAL ENGINEERING

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

Spring loaded resistance thermometer

Thermocouples Model TC10-B, for Additional Thermowell

RTD PT100 Insert With Solid Drilled Flanged Thermowell

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

Resistance thermometer with digital indicator Model TR75, battery operation

Thermocouple Model TC10-E, for additional thermowell

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Thermocouple For additional thermowell Model TC10-B

Mid-West Instrument. Piston Type Model 220. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Metal tube variable area flowmeter for gases, liquids and steam

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Thermocouples Model TC10-E, for Additional Thermowell

JUMO safetym TB/TW Temperature limiter, temperature monitor according DIN EN

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Thermocouples TE Measuring Insert. rigid Model TC 001 flexible Model TC 002. Electronic Temperature Measurement

Resistance thermometer with digital display Model TR75, battery operation

Point level measurement Capacitance switches

Resistance thermometer Without thermowell Model TR10-H

Resistance thermometer Model TR10-E, for additional thermowell

Flanged resistance thermometer Model TR10-F, with fabricated thermowell model TW40

General Information... Temperature/Resistance Table... Part Numbering Examples for RTD s. High Temperature MgO Elements (RA)...

Mid-West Instrument. Diaphragm Type Model 240. Hazardous Locations. Indicating / Non-Indicating Differential Pressure Switch or Transmitter

Omnigrad TA20, TA21. Technical Information. Temperature Measuring Technology Terminal heads for mounting on thermowells of resistance thermometers

Thermocouple Without thermowell Model TC10-H

Process controller. for pneumatic and electric actuators. Process controller V. Process controller

Threaded resistance thermometer Model TR10-C, with fabricated thermowell model TW35

Measuring insert For thermocouple with flameproof enclosure (TC10-L) Model TC10-K

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Surface thermocouple Model TC50

Thermocouple Model TC10-H without thermowell

Analog input module. Brief description. Page 1/8. Data Sheet

SPRING LOADED RESISTANCE THERMOMETER CONFIGURATIONS

Resistance thermometer Model TR10-B, for additional thermowell

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

JUMO dtrans p20 DELTA

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Accord DS/DM Series UltraSwitch Switch box

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Turbine flowmeters Series TM

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

POSITIONERS and Controls for Complete Valve Automation

Armstrong In-Line and Insertion Vortex Flow Meters

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Temperature Switch Gauges

Industrial Pt100 RTD's

Technical specification

Transmitter Housing Model: CET5000-G CET5000-P CET5000-P. Optional Extended cable For Remote Mounting. (6 or 12 feet length)

Compact temperature switch Model TCS

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

Direct immersion resistance thermometer

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Ø 68 mm to ø 115 mm. Material: Weight: Bearing Life: Shaft Loads: Operating Temp.: Storage Temp.: Shock: Vibration: Bump: Humidity: Enclosure Rating:

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Description. Fieldbus Optimized Through Junction Boxes

Certificate of Conformity

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

PROCESS INSTRUMENTATION

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

General spare parts. Accessories & Spare parts. Ordering information. SPB03: Battery with retrofit battery clamp (XX) Lithium 3xAA-Cell batteries

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

Gas-actuated thermometer with switch contacts Stainless steel version Model 73

Miniature pressure switch, flameproof enclosure Ex d For the process industry Model PXA

Cable thermocouple Model TC40

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Measuring insert for process resistance thermometer

Temperature Measurement Solutions. Dial Indicating Electronic Industrial RTDs Thermowells Accessories

Rosemount 214C Temperature Sensors

Cable resistance thermometer Model TR40

Magnetic-inductive flow meter for hazardous areas

Mini temperature switch Stainless steel switch enclosure Model TXS

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Electronic Monitoring Systems

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

OM004, OM006 & OM008 Oval Gear Meter

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Level limit switch Series RF 3000 Selection list

Series 3730 Electropneumatic Positioner Type

Compact differential pressure switch Models DC, DCC

Differential pressure gauge Model , copper alloy Model , stainless steel version

Tubeskin thermocouple assembly Model TC59-V

F-1500 SERIES INSERTION TURBINE FLOW METER

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

Field IT Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters Standard Model with Booster Stage

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Data Sheet SCHISCHEK EXCOS-P. Pressure sensor 20 Pa Pa. Supplied by. .com. Call us on +44 (0)

F-2700 SERIES INSERTION VORTEX FLOW METER

L(+) SV1 N(-) NC. Terminal Block Connections L (+) N (-) SV1 K2 K1. Refer to "General Notes Relating to Pepperl+Fuchs Product Information".

Transcription:

NOV 2014 FM, CSA, ATEX, IECEx CERTIFIED

COMPANY PROFILE E stablished in 1991 by a group of engineers with a wealth of experience in instrument and process control, IME has developed a complete line of supportive products for a wide range of industry needs, ranging from highly demanding off shore exploration to the basic needs of the food and beverage industries. Our products range from valves and manifolds available for OEM and private labeling agreements to junction boxes, custom designed enclosures as well as a full range of temperature measuring instruments and accessories. Our products are economically priced and designed to meet the needs of our OEM's worldwide as well as end users with no compromise in quality. In addition to and ISO 9001:2008 Quality award, IME has both a QAN (Quality Assurance Notification) and QAR (Quality Assurance Report) which allows us to design and manufacture products that meet the stringent requirements of the ATEX and IECEx directives. Fully equipped with state of the art manufacturing facilities and backed by a team of qualified and dedicated design and production engineers, IME is positioned to meet the ever

Table of Contents Page 108KNR Battery Operated Digital Temperature Indicator in Polycarbonate Enclosure 1 Digital Temperature Indicators 8080KN Battery Operated Digital Temperature Indicator (Explosion Proof) 3 8080PR Indicating Temperature Switch with Dual Relays (Explosion Proof) 4 Temperature Transmitters 8070HN Head Mounted Temperature Transmitter 6 8070HH Head Mounted Transmitter with HART 7 8080HT Field Mounted Indicating Transmitter with HART (Explosion Proof) 8 Mounting Brackets for Temperature Indicators and Transmitters 11 Thermocouple Heads 14 Temperature Sensor Accessories 20 Thermowell Threaded Thermowells 22 Flanged Thermowells 23 Temperature Sensor Assembly 92 Series Explosion Proof Nipple Union Temperature Assembly 24 93 Series Spring Loaded Stainless Steel Nipple 25 98 Series Temperature Assembly With Indicator / Transmitter 26 99 Series Explosion Proof Temperature Assembly 27

BATTERY OPERATED DIGITAL TEMPERATURE INDICATOR 108KNR INPUT Pt100 RTD 4 DIGIT LCD DISPLAY IN DEGREES C OR F POLYCARBONATE ENCLOSURE DESIGNED TO REPLACE BIMETALLIC SENSORS WALL OR PIPE MOUNTING Introduction IME Model 108KNR is a Battery Operated Digital Temperature Indicator which accepts a standard Pt100 RTD sensor and provides a crisp 4 digit LCD(approx height 12.5mm or 1/2"). When compared to the archaic Bimetallic indicators, operating costs are reduced since just one device covers the entire range of local temperature measurement(-200 C to +850 C) with higher accuracy. Model 108KNR is designed for use in process industries where vibration, inclement weather and corrosive atmospheres prevail. The electronics are enclosed in a low cost UV resistant polycarbonate housing, which meets NEMA 4X and IP66/68 requirements. Mounting The Model 8080KN can be either remotely mounted or mounted directly on the thermowell/nipple assembly. For mounting the unit on a wall or 2" pipe a wide choice of stainless steel brackets are also available.(see Page 2) Functional Specifications Sensor RTD Pt100 Indication Accuracy Better than ±0.1 C Display Height 12.5mm (½") high Display Units C or F, switch selectable Battery Life Approx. 24 Months using Lithium AA cells Calibration Single point calibration for enhanced accuracy Ambient Operating Temperature -20 C to +60 C Material of Construction of Enclosure UV Resistant Polycarbonate O Rings Hydrogenated Nitrile Optional Accessories Mounting Brackets (Model 175RC & 175PM) Ordering Information See page 2 for complete ordering information. POLYCARBONATE ENCLOSURE DIMENSIONS 100mm (3.9") 88mm (3.7") 86mm (3.4") Ø83mm (3.2") T1 Ø31mm (1.2") T1 5mm (0.2") 1

ORDERING INFORMATION FOR TEMPERATURE INDICATOR INTERNATIONAL METAL ENGINEERING Model 108KNR 108KN Field Mounted Battery Powered Digital Temperature Indicator (RTD Pt100 only) Field Mounted Battery Powered Digital Temperature Indicator (RTD Pt100 or Thermocouple Type J / K) Code Instrument Connection (T1) Conduit Size (T2) 01 M16 x 2P(See Note 1) None 02 ½" NPT None 03 ½" BSP None XX OTHER(SPECIFY) OTHER(SPECIFY) Code Size of Thread & Cable(mm) for Nylon Cable Glands C00 No Cable Gland Required C01 ½" NPT, Cable Size 5-9mm dia, IME Model 108CG-N-01 C02 ½" NPT, Cable Size 6-12mm dia, IME Model 108CG-N-02 C03 ½" NPT, Cable Size 10-14mm dia, IME Model 108CG-N-03 C04 ¾" NPT, Cable Size 9-16mm dia, IME Model 108CG-N-04 C05 ¾" NPT, Cable Size 13-18mm dia, IME Model 108CG-N-05 C06 M20 x 1.5P, Cable Size 5-9mm dia, IME Model 108CG-N-06 C07 M20 x 1.5P, Cable Size 6-12mm dia, IME Model 108CG-N-07 C08 M20 x 1.5P, Cable Size 10-14mm dia, IME Model 108CG-N-08 Code Accessories RC Model 175RC Mounting Bracket PM Model 175PM Mounting Bracket Code 2 Inch "U" Bolt with Nuts and Washers 00 None 01 Model 17508, 1 Set (For Model 175RC) 02 Model 17508, 2 Sets (For Model 175PM) 108KNR 02 C02 RC 01 Typical Model Number Note: 1 Ports with M16 x 2P thread are not through holes, they are for Mounting only. STAINLESS STEEL MOUNTING BRACKET MODEL 175RC Introduction This simple hollow square mounting bracket constructed out of SS316 Stainless Steel, can be used to mount a variety of field devices, either on a wall or panel or a 2" Pipe. When mounting on a 2" pipe, a "U" Bolt is required, which can be supplied optionally. STAINLESS STEEL MOUNTING BRACKET MODEL 175PM Introduction This simple "L" Shape mounting bracket constructed out of SS316 Stainless Steel, can be used to mount a variety of field devices, either on a wall or panel or on a 2" pipe. When mounting on a 2" pipe, two "U" Bolts are required, which can be supplied optionally. Provision for M16 mounting bolt NYLON CABLE GLANDS MODEL 108CG THREAD SIZE CABLE SIZE(mm) MODEL NO 5-9 108CG-N-01 ½" NPT 6-12 108CG-N-02 10-14 108CG-N-03 9-16 108CG-N-04 ¾" NPT 13-18 108CG-N-05 5-9 108CG-N-06 M20 x 1.5P 6-12 108CG-N-07 10-14 108CG-N-08 2

DIGITAL TEMPERATURE INDICATORS MODEL 8080KN BATTERY OPERATED DIGITAL TEMPERATURE INDICATOR INPUT THERMOCOUPLE OR RTD 4 DIGIT LCD DISPLAY IN DEGREES C OR F RUGGED NEMA 4X, IP68 ENCLOSURE DESIGNED TO REPLACE BIMETALLIC SENSORS CHOICE OF COPPER-FREE ALUMINUM OR SS316 ENCLOSURE EXPLOSION PROOF CERTIFIED 3 YEAR WARRANTY Introduction IME Model 8080KN is a Battery Operated Digital Temperature Indicator which accepts an input from a standard Type J or K Thermocouple or RTD and provides local indication of temperature in degrees C or F. Designed specifically to replace Bimetallic Sensors, 8080KN becomes a universal instrument since only one instrument will indicate the entire useful range of the thermocouple or RTD. This eliminates having several bimetallic sensors where the dial range has to be predetermined. Operating costs are also drastically reduced since the temperature sensor can be easily replaced in case of failure, unlike a bimetallic sensor where the entire instrument has to be discarded. Furthermore thermocouples and RTDs are a lot more reliable, accurate and stable when compared to the archaic bimetallic sensor. Model 8080KN is designed for use in process industries where vibration, inclement weather and corrosive atmospheres prevail. The electronics are enclosed in a copper-free epoxy coated Aluminum housing and for more aggressive environments a SS316 housing is optionally available. The housing meets the requirements of NEMA 4X & IP68, and are also certified Explosion Proof by FM/CSA. Mounting A wide choice of stainless steel mounting brackets are also available for mounting the Model 8080KN on either a 2" pipe or wall. (See detailed information of mounting bracket on page 11, 12 & 13) Certification System C FM US APPROVED CLASS I, DIV I GROUPS B, C AND D CLASS II/III, DIV I GROUPS E, F AND G NEMA 4X, T6 Functional Specifications Sensor Thermocouple Type J / K or RTD Pt100 Indication Accuracy ±0.5 C Display Height 12.5mm (½") high Display Units C or F, switch selectable Battery Life Approx. 12 Months Calibration Single point calibration for enhanced accuracy Ambient Temperature -20 C to +60 C Weight 0.9kg (2 lbs) for Aluminum Unit and 1.4kg (3 lbs) for SS316 unit not including sensor O Rings Hydrogenated Nitrile Optional Accessories C US CLASS I, DIV I GROUPS B, C AND D CLASS II/III, DIV I GROUPS E, F AND G NEMA 4X, T6 Mounting Brackets (Model 175PM, 175RC, 175NR, 175MM) Refer to Page 11, 12 & 13 for detail. 3

DIGITAL TEMPERATURE INDICATORS MODEL 8080PR INDICATING TEMPERATURE SWITCH WITH DUAL RELAYS INPUT THERMOCOUPLE AND RTD 4 DIGIT LED DISPLAY IN DEGREES C OR F RUGGED NEMA4X, IP68 ENCLOSURE CHOICE OF COPPER-FREE ALUMINUM OR SS316 ENCLOSURE EXPLOSION PROOF CERTIFIED 3 YEAR WARRANTY Introduction Model 8080PR allows 2 independent alarms to be assigned over the temperature range of the sensor. The unit will accept an input from a Pt100 RTD or Type J or K thermocouple and provide an indication on a bright 4 digit LED. The unit serves a dual purpose since in addition to local indication of temperature, which is switch selectable to read C or F, it also serves as an accurate and repeatable temperature switch. Model 8080PR Temperature Indicators are designed for using in process industries where vibration, inclement weather and corrosive atmospheres prevail. The electronics are enclosed in a copper-free epoxy coated Aluminum housing. For more aggressive environments, a SS316 housing is also available. Housings meet the requirements of NEMA 4X & IP68, and are also certified Explosion Proof by FM/CSA/ATEX/IECEx. LED Meter The Model 8080PR has a 4 digit LED display and may be configured to read -999 to 9999. The decimal point location, choice of C or F, alarm settings etc can be adjusted via the Front Panel. Mounting The Model 8080PR can be either remotely mounted or mounted directly on the thermowell/nipple assembly. For mounting the unit on a wall or 2" pipe, a wide choice of stainless steel mounting brackets are also available. (See detailed information of mounting bracket on page 11, 12 & 13) Certification System C FM US APPROVED CLASS I, DIV I GROUPS B, C AND D CLASS II/III, DIV I GROUPS E, F AND G NEMA 4X, T6 CLASS I, DIV I GROUPS B, C AND D CLASS II/III, DIV I GROUPS E, F AND G NEMA 4X, T6 II 2G D Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C Functional Specifications Indication Accuracy 0.1% of Calibrated range ±1 digit Set Point Adjustment 10 to 100% of full scale, user selectable Reset Automatically when the input falls below the alarm set point by approximately ±0.5% of full scale. Alarm Set Point Accuracy ±0.5% of full scale. Alarm Status Indication LED on front panel Display Height 12.5mm (1/2") high Alarm Output 2 sets SPDT, 1 from C, rated 5A @ 250V AC, 50/60Hz Stability Over Time 0.1% of calibrated range ±1 digit over 6 months Over Range Indication Flashing of display Response Time Typically 75ms Supply Voltage 18 to 28V DC Operating Temperature -40 C to +60 o C Weight 0.9Kg (2 lbs) for Aluminum Unit and 1.4Kg (3 lbs) for SS316 unit O Rings Hydrogenated Nitrile Optional Accessories Mounting Brackets (Model 175PM, 175RC, 175NR, 175MM) Refer to Page 11, 12 & 13 for detail. Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C 4

DIGITAL TEMPERATURE INDICATORS Ordering Information Model 8080KN 8080PR Battery Powered Digital Temperature Indicator Indicating Temperature Switch with Dual Relays Code Options, Housing A Die cast Aluminum, Epoxy Coated T SS316, Electro Polished Code Instrument Connection (T1) Conduit Size (T2) 01 M16 x 2P (See note 1) ¾" NPT 02 M16 x 2P (See note 1) ½" NPT 03 M16 x 2P (See note 1) M20 x 1.5P 04 ½" NPT ¾" NPT 05 ½" NPT ½" NPT 06 ½" NPT M20 x 1.5P 07 ¾" NPT ¾" NPT 08 ¾" NPT ½" NPT 09 ¾" NPT M20 x 1.5P 10 ½" BSP ¾" NPT 11 ½" BSP ½" NPT 12 ½" BSP M20 x 1.5P 13 ¾" NPT None 14 M20 x 1.5P None 16 ½" BSP None 17 ½" NPT None Code Certification NN None E1 FM / CSA / ATEX / IECEx Explosion Proof Certified, NEMA 4X, IP68 Code Accessories (See Page 13) RC Model 175RC Mounting Bracket PM Model 175PM Mounting Bracket NR Model 175NR Mounting Bracket MM Model 175MM Mounting Bracket Code 00 01 02 2 Inch "U" Bolt with Nuts and Washers None Model 17508, 1 Set (For Model 175RC) Model 17508, 2 Sets (For Model 175PM & 175NR) 8080PR A 17 E1 NR 02 Typical Model Number Note: 1) Ports with M16 x 2P thread are not through holes, they are for Mounting only. 2) M20 X 1.5P Threads are not approved by CSA 3) 1/2" BSP Threads are not approved by FM and CSA Enclosure Dimensions 5

TEMPERATURE TRANSMITTER SERIES HEAD MOUNTED TRANSMITTER 2 WIRE, 4 TO 20mA ANALOG OUTPUT 8070HN HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE RANGE AN INTERNAL TEMPERATURE SENSOR FOR ACTIVE TEMPERATURE COMPENSATION (FOR T/C) 3 YEAR WARRANTY INPUT Resistance Thermometer (RTD) Pt 100, Cu 50, Cu 100 Resistance Transmitter 0 to 400 Ω Votage Transmitter (mv) -10 to 75mV Thermocouple Types B,E,J,K,N,R,S and T TYPE OUTPUT Output Signal 4 to 20 ma Under Range Linear Drop to 3.8mA Over Range Linear Rise to 20.8mA Sensor Breakage < 3.8mA Load Max. (V power supply - 7.5 V) / 0.0208A Supply Voltage POWER SUPPLY 7.5 to 45 VDC, Polarity Protected SPECIFICATION Response time 1s Reference Operation Conditions Calibration temperature: 23 C (75 F) Long Term Stability 0.05% / Year Infuence of ambient Temperature Negligible Load Influence Negligible Power Supply Influence Negligible Ambient Temperature Limits -40 C to 85 C Ingress Protection IP 68 when installed in a 1080 or 8080 Enclosure Dimensions Dia. 44mm x 22.5 mm Mounting Fits in any standard thermocouple head Ordering Information Model 8070HN Head Mounted Temperature Transmitter TEMPERATURE TRANSMITTER ENCLOSURE Optional Explosion Proof Thermocouple Heads that can be used to mount the 8070HN Temperature Transmitter inside is optionally available. The electronics can be enclosed in a copper-free epoxy coated Aluminum housing and for more aggressive environments, a SS316 housing is optionally available. The housing meets the requirements of NEMA 4X / IP68, and are certified Explosion Proof by ATEX/IECEx. Refer to Page 14-18 for more detail. 8080HN IME Model 8080HN is an Explosion Proof Temperature Transmitter Enclosure with IME Model 8070HN Temperature Transmitter Unit inside. The housing comes with solid cover and it can be copper-free epoxy coated Aluminum or SS316 for more aggressive environments. The housing meets the requirements of NEMA 4X / IP68. The whole Assembly is certified Explosion Proof by ATEX / IECEx. Refer to Page 10 for complete ordering information. Certification System II 2G D Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C 6

TEMPERATURE TRANSMITTER SERIES HEAD MOUNTED TRANSMITTER WITH HART UNIVERSAL SETTINGS WITH HART - PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE, 4 TO 20mA ANALOG OUTPUT + HART HIGH ACCURACY OVER TOTAL AMBIENT TEMPERATURE RANGE GALVANIC ISOLATION AN INTERNAL TEMPERATURE SENSOR FOR ACTIVE TEMPERATURE COMPENSATION (FOR T/C) WIDE VOLTAGE SUPPLY RANGE 3 YEAR WARRANTY 8070HH INPUT Resistance Thermometer (RTD) Resistance Transmitter Range/ Min Range Thermocouple Types Voltage Transmitters (mv) / Min Range TYPE Pt100, Pt500, Pt1000, Cu50, Cu100, Ni100, Ni500, Ni1000 0 to 400Ω / 10Ω, 0 to 2000Ω / 20Ω, 0 to 1000Ω / 100Ω B,E,J,K,N,R,S and T -10 to 75mV / 5mV, -100 to 100mV / 5mV -100 to 500mV / 6mV, -100 to 2000mV / 20mV OUTPUT Output Signal 4 to 20 ma + Hart Under Range Linear Drop to 3.8mA Over Range Linear Rise to 20.8mA Load Max. (V power supply - 7.5 V) / 0.0208A Galvanic Isolation U=2KV AC (input/ output) Supply Voltage POWER SUPPLY 7.5 to 45 VDC/ Polarity Protected SPECIFICATION Programmable Easy programming with USB Response Time 1s Reference Operating Conditions Calibration Temperature:23 C ± 5K Long Term Stability 0.05% / year Switch On Delay 5s Self Stability Configuration 0 to 2% Filter Configuration 0 to 160 µa Input Current Required 3.8mA Current Limit 20.8mA Ambient Temperature Limits -40 to 85 C Degree of Protection IP 68 when installed in a 1080 or 8080 Enclosure Shock and Vibration Resistance As per IEC 60 068-26 Dimensions Mounting Ordering Information Model 8070HH Universal Temperature Transmitter With HART Optional Dia. 44mm x 22.5 mm TEMPERATURE TRANSMITTER ENCLOSURE WITH HART Fits in any standard thermocouple head Explosion Proof Thermocouple Heads that can be used to mount the 8070HH Temperature Transmitter inside is optionally available. The electronics can be enclosed in a copper-free epoxy coated Aluminum housing and for more aggressive environments, a SS316 housing is optionally available. The housing meets the requirements of NEMA 4X / IP68, and are certified Explosion Proof by ATEX/IECEx. Refer to Page 14-18 for more detail. 8080HH IME Model 8080HH is an Explosion Proof Temperature Transmitter Enclosure with IME Model 8070HH Temperature Transmitter Unit inside. The housing comes with solid cover and it can be copper-free epoxy coated Aluminum or SS316 for more aggressive environments. The housing meets the requirements of NEMA 4X / IP68. The whole Assembly is certified Explosion Proof by ATEX / IECEx. Refer to Page 10 for complete ordering information. Certification System 7 II 2G D Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C

TEMPERATURE TRANSMITTER SERIES FIELD MOUNTED INDICATING TRANSMITTER WITH HART 8080HT UNIVERSAL SETTINGS WITH HART PROTOCOL FOR VARIOUS INPUT SIGNALS 2 WIRE TECHNOLOGY, 4 TO 20mA ANALOG OUTPUT HIGH ACCURACY IN TOTAL AMBIENT TEMPERATURE RANGE GALVANIC ISOLATION AN INTERNAL TEMPERATURE SENSOR FOR ACTIVE TEMPERATURE COMPENSATION WIDE VOLTAGE SUPPLY CUSTOMER SPECIFIC MEASUREMENT RANGE SETTINGS SIMPLE AND USER FRIENDLY SOFTWARE MULTIPLE BACKLIGHT ROTATABLE LCD DISPLAY CHOICE OF COPPER-FREE ALUMINUM OR SS316 ENCLOSURE EXPLOSION PROOF CERTIFIED 3 YEAR WARRANTY Introduction Model 8080HT is a digital, PC/Hand-Held programmable, isolated 2-wire transmitter with HART protocol. The unit converts 8 types of thermocouples; 8 types of RTDs, configured as 2, 3 and 4 wires; potentiometer, resistor and millivolt inputs into process current loop. Mounting The Model 8080HT can be either remotely mounted or mounted directly on the thermowell/nipple assembly. For mounting the unit on a wall or 2" pipe, a wide choice of stainless steel mounting brackets are also available. (See detailed information of mounting bracket on page 11, 12 & 13) Model 8080HT Universal Input Transmitters are designed for use in process industries where vibration, inclement weather and corrosive atmospheres prevail. The electronics are enclosed in a copper-free epoxy coated Aluminum housing and for more aggressive environments, a SS316 housing is optionally available. The housings meet the requirements of NEMA 4X / IP68, and are certified Explosion Proof by ATEX/IECEx. Exceptional digital accuracy of typical ±0.1 C is provided for all the sensors regardless of the calibrated span. Extremely accurate cold-junction temperature measurement provides precise compensation throughout the entire ambient range. The unit also accurately measures and compensates the RTD sensor leads in the 3-wire connection. Ordering Information See Page 10 for complete ordering information. Certification System II 2G D Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 Ta = -40 C to +60 C Ex d IIC T6 Gb Ex tb IIIC T85 C Db IP68 The transmitter is fully configurable by connecting to a PC or a Hand-Held programmer.the configuration parameters are stored in a non volatile memory. Detection of sensor breakage or disconnection of input leads, forces the output to a pre-defined up/down scale value. The unit continuously monitors the sensor and automatically returns to normal operation mode when the sensor is recovered. In applications where no local indication is required, the tempered glass cover is replaced by a solid cover and no LCD indicator is provided. 8

TEMPERATURE TRANSMITTER SERIES FIELD MOUNTED INDICATING TRANSMITTER WITH HART Input 8080HT Resistance Thermocouple (RTD) ResistanceTransmitter Thermocouple (TC) VoltageTransmitters (mv) Pt100 Pt500 Pt1000 Cu50 Cu100 Ni100 Ni500 Ni1000 Type Resistance (Ω) B (PtRh30-PtRh6) E (NiCr-CuNi) J (Fe-CuNi) K (NiCr-Ni) N (NiCrSi-NiSi) R (PtRh13-Pt) S (PtRh10-Pt) T(Cu-CuNi) Millivolt transmitter(mv) Measurement Ranges Min. meas. Maximum Measured Ranges Error -200 C to 850 C (-328 F to 1562 F) 10K 0.2K or 0.08% -200 C to 850 C (-328 F to 1562 F) 10K 0.5K or 0.20% -200 C to 850 C (-328 F to 1562 F) 10K 0.3K or 0.12% -50 C to 150 C (-58 F to 302 F) 10K 0.2K or 0.08% -50 C to 150 C (-58 F to 302 F) 10K 0.3K or 0.12% -60 C to 180 C (-76 F to 356 F) 10K 0.2K or 0.08% -60 C to 180 C (-76 F to 356 F) 10K 0.5K or 0.20% -60 C to 180 C (-76 F to 356 F) 10K 0.3K or 0.12% 0 to 400 Ω 10 Ω ± 0.1Ω or 0.08% 0 to 2000 Ω 20 Ω ± 1.5Ω or 0.12% 0 to 10000 Ω 100 Ω ± 7.5Ω or 0.20% 0 to 1820 C (32 to 3308 F) 500K typ. 2.0K or 0.08% -270 to 1000 C (-454 to 1832 F) 50K typ. 0.5K or 0.08% -210 to 1200 C (-346 to 2192 F) 50K typ. 0.5K or 0.08% -270 to 1372 C (-454 to 2501 F) 50K typ. 0.5K or 0.08% -270 to 1300 C (-454 to 2372 F) 50K typ. 1.0K or 0.08% -50 to 1768 C (-58 to 3214.4 F) 500K typ. 2.0K or 0.08% -50 to 1768 C (-58 to 3214.4 F) 500K typ. 2.0K or 0.08% -270 to 400 C (-454 to 752 F) 50K typ. 0.5K or 0.08% -10 to 75 mv 5 mv ± 20 µv or 0.08% -100 to 100 mv 5 mv ± 20 µv or 0.08% -100 to 500 mv 6 mv ± 30 µv or 0.08% -100 to 2000 mv 20 mv ± 50 µv or 0.08% Output Output Signal 4 to 20 ma + Hart Signal On Alarm Underranging Linear drop to 3.8 ma Overranging Linear rise to 20.8 ma Sensor break; sensor open-circuit <3.8 ma Load Max. (V power supply - 7.5 V) / 0.0208A (without display) Linearization/Transmission Behavior Galvanic Isolation Power Supply Max. (V power supply - 10.5 V) / 0.0208A (with display) Temperature linear, resistance linear, voltage linear U = 2 KV AC (input/output) Supply Voltage (polarity protected) U b = 10.5 to 45 VDC (with display) Performance Characteristic Response Time 1s Reference Operating Calibration Temperature : 23 C (73.4 F) ± 5K Conditions Long Term Stability 0.05% / year Switch On Delay 5s Self Stability Configuration 0 to 2% Filter Configuration 0 to 160 µa Resolution 0.3 µa Environment Condition Ambient Temperature Limits -40 to 85 C (-40 F to 195 F) Without display -20 to 70 C (-4 F to 158 F) With display Storage Temperature -40 to 100 C (-40 F to 212 F) Condensation 100% Electromagnetic Interference immunity and interference emission according Compatibility (EMC) to GB/T17626.2-1998), compliance with IEC 61000-4-3:1995 9

TEMPERATURE TRANSMITTER SERIES Ordering Information For Temperature Transmitter INTERNATIONAL METAL ENGINEERING Model 8080HH 8080HN 8080HT Temperature Transmitter Enclosure With HART (Explosion Proof) (See Note 2 & 3) Temperature Transmitter Enclosure (Explosion Proof) (See Note 2 & 3) Field Mounted Indicating Transmitter with HART (Explosion Proof) (See Note 2) Code Options, Housing A Die cast Aluminum, Epoxy Coated T SS316, Electro Polished Code Instrument Connection (T1) Conduit Size (T2) 01 M16 x 2P (See note 1) ¾" NPT 02 M16 x 2P (See note 1) ½" NPT 03 M16 x 2P (See note 1) M20 x 1.5P 04 ½" NPT ¾" NPT 05 ½" NPT ½" NPT 06 ½" NPT M20 x 1.5P 07 ¾" NPT ¾" NPT 08 ¾" NPT ½" NPT 09 ¾" NPT M20 x 1.5P 10 ½" BSP ¾" NPT 11 ½" BSP ½" NPT 12 ½" BSP M20 x 1.5P 13 ¾" NPT None 14 M20 x 1.5P None 16 ½" BSP None 17 ½" NPT None Code Certification NN None E1 ATEX / IECEx Explosion Proof Certified, IP68, T6 Code Accessories RC Model 175RC Mounting Bracket PM Model 175PM Mounting Bracket NR Model 175NR Mounting Bracket MM Model 175MM Mounting Bracket Code 2 Inch "U" Bolt with Nuts and Washers 00 None 01 Model 17508, 1 Set (For Model 175RC) 02 Model 17508, 2 Sets (For Model 175PM & 175NR) 8080HT A 02 E1 PM 02 Typical Model Number Note: 1 Ports with M16 x 2P thread are not through holes, they are for Mounting only. 2 8080HH, 8080HN and 8080HT are certified ATEX and IECEx only. 3 8080HH and 8080HN are assembled in a Blind Enclosure. 110mm (4.3") 94mm (3.7") T2 T2 Ø30mm (1.2") 100mm (3.9") Ø82mm (3.2") T1 Ø30mm (1.2") 10

STAINLESS STEEL MOUNTING BRACKET FOR FIELD DEVICES Mounting Bracket 175RC Introduction This simple hollow square mounting bracket constructed out of SS316 Stainless Steel, can be used to mount a variety of field devices, either on a wall or panel or a 2" Pipe. When mounting on a 2" pipe, a "U" Bolt is required, which can be supplied optionally. IME Model 17508 consists of a complete assembly of a 2" U bolt along with the nuts and washers required. Mounting Bracket 175PM Introduction This simple "L" Shape mounting bracket constructed out of SS316 Stainless Steel, can be used to mount a variety of field devices, either on a wall or panel or on a 2" pipe. When mounting on a 2" pipe, a "U" Bolt is required, which can be supplied optionally. IME Model 17508 consists of a complete assembly of a 2" U bolt along with the nuts and washers required. Mounting Bracket 175NR Introduction IME MODEL 175NR is Stainless Steel Mounting Brackets made exclusively for IME MODEL 8080 Instrument Enclosure to mount on a 2 " Pipe. This Bracket is available for customers who require all 3 ports on the enclosure for other purposes. The 175NR is symetrical, so it can be rotated 90 to suit the viewing position of the Indicator/Transmitter. Mounting Bracket 175MM Introduction IME MODEL 175MM is Stainless Steel Mounting Brackets made exclusively for IME MODEL 8080 Instrument Enclosure to mount on wall. This low cost Bracket is available for customers who require all 3 ports on the enclosure for other purposes. 11

MOUNTING BRACKETS FOR INDICATORS AND TRANSMITTERS Mounting Methods For Model 175RC Pipe Mounting 2" Pipe Indicator/Transmitter Wall / Panel Mounting Wall/Panel "U" Bolt (Optional Item) Mounting Adapter (Supplied with Mounting Bracket) 175RC Mounting Bracket 9mm or 5/16 Bolts (Not Supplied) Mounting Methods For Model 175PM Pipe Mounting 2" Pipe Indicator/Transmitter Wall / Panel Mounting Wall/Panel M16 Bolt (Supplied with Mounting Bracket) 175PM Mounting Bracket "U" Bolt (Optional Item) 9mm or 5/16 Bolts (Not Supplied) 12

MOUNTING BRACKETS FOR INDICATORS AND TRANSMITTERS Mounting Methods For Model 175NR Pipe Mounting "U" Bolts (Optional) 2" Pipe 175NR Mounting Bracket Vertical Pipe Indicator/Transmitter Horizontal Pipe Mounting Methods For Model 175MM Wall/Panel Mounting Wall 9mm or 5/16 Bolts (Not Supplied) 175MM Mounting Bracket Indicator/Transmitter 13

THERMOCOUPLE HEADS EXPLOSION PROOF CERTIFIED NEMA 4X AND IP66/68 CONSTRUCTION WIDE SELECTION OF CONDUIT SIZES OPTION FOR A CUSTOMIZED SS NAMEPLATE WIDE RANGE OF ACCESSORIES Introduction Material of Construction: Dimensions Assembly Drawing Copper-Free Die-cast Aluminum Certification: FM/CSA/ATEX/IECEx Explosion Proof Certified, NEMA 4X and IP66/68 Connections ½" NPT, ¾" NPT, ½" BSP, M20x1.5P Mounting Holes See attached drawing Surface Finishing Epoxy Coated "O" Ring Hydrogenated Nitrile Weight 0.5 KG (1.1 lbs) Accessories SS Ball Chain, Terminal Block(Ceramic/Bakelite, Optional) Custom Designed SS Nameplate Certification System M4 X 0.7 Mounting Hole Positions FM APPROVED CLASS I, DIV I GROUPS B, C AND D CLASS II, DIV I GROUPS E, F AND G NEMA 4X, IP66 CLASS I, DIV I GROUPS B, C AND D CLASS II, DIV I GROUPS E, F AND G NEMA 4X ATEX II 2GD Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 14

MODEL 1080 ALUMINUM EXPLOSION PROOF THERMOCOUPLE HEAD IME Model 1080 Series Aluminum Thermocouple Heads are designed specifically for explosion proof applications and constructed out of Die-Cast Copper-Free Aluminum to withstand applications where aggressive atmospheres prevail. This housing accommodates a terminal block or head mounted transmitter 50mm (2.0") in diameter that can be mounted using M4 screws as indicated in the attached drawing. Some units as indicated has a provision for a customer designed SS nameplate with information such as model number, company name, logo, and website etc. Ordering Information for Explosion Proof Heads Model 1080AE 1080AA 1080AT 1080AM 1080WE 1080WT 1080WM FM/CSA Ex-Proof Certified, NEMA 4, IP66, Aluminum Thermocouple Head, Grey Painted FM/CSA Ex-Proof Certified, NEMA 4, IP66, Aluminum Thermocouple Head with Provision for Name Plate, Grey Painted ATEX / IECEx Ex-Proof Certified, IP68, Aluminum Thermocouple Head with Provision for Name Plate, Grey Painted FM / CSA / ATEX / IECEx Ex-Proof Certified, NEMA 4, IP66/68, Aluminum Thermocouple Head with Provision for Name Plate, Grey Painted FM/CSA Ex-Proof Certified, NEMA 4X, IP66, Aluminum Thermocouple Head with Provision for Name Plate Blue Epoxy Painted ATEX / IECEx Ex-Proof Certified, IP68, Aluminum Thermocouple Head with Provision for Name Plate, Blue Epoxy Painted FM / CSA / ATEX / IECEx Ex-Proof Certified, NEMA 4X, IP66/68, Aluminum Thermocouple Head with Provision for Name Plate, Blue Epoxy Painted Code Conduit Size (T1) Instrument Connection (T2) 01 T1=¾" NPT T2=½"NPT 02 T1=½" NPT T2=½"NPT 05 T1=M20X1.5 (See Note 2) T2=½"BSP (See Note 1) 08 T1=M20X1.5 (See Note 2) T2=½"NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify 1080WM - 01 Typical Model Number Note : 1 BSP Thread is not Certified by FM & CSA 2 M20X1.5 is not Certified By CSA Ordering Information for General Purpose Heads Model 1080AN 1080WN 1080WG Aluminum Thermocouple Head with Provision for Name Plate, Grey Painted Aluminum Thermocouple Head with Provision for Name Plate, Blue Epoxy Painted Aluminum Thermocouple Head with Tempered Glass Window, Blue Epoxy Painted Code Conduit Size (T1) Instrument Connection (T2) 01 T1=¾" NPT T2=½"NPT 02 T1=½" NPT T2=½"NPT 05 T1=M20X1.5 T2=½"BSP 08 T1=M20X1.5 T2=½"NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify 1080AN - 01 Typical Model Number 15

MODEL 1080 STAINLESS STEEL EXPLOSION PROOF THERMOCOUPLE HEAD EXPLOSION PROOF CERTIFIED NEMA 4X AND IP66/68 CONSTRUCTION WIDE SELECTION OF CONDUIT SIZES OPTION FOR A CUSTOMIZED SS NAMEPLATE WIDE RANGE OF ACCESSORIES Introduction Material of Construction: Dimensions Assembly Drawing SS 316 Certification: FM/CSA/ATEX/IECEx Explosion Proof Certified, NEMA 4X and IP66/68 Connections ½" NPT, ¾" NPT, ½" BSP, M20x1.5P Mounting Holes See attached drawing Surface Finishing Electro-Polished "O" Ring Hydrogenated Nitrile Weight 1.0 KG (2.2 lbs) Accessories SS Ball Chain, Terminal Block(Ceramic/Bakelite, Optional) Custom Designed SS Nameplate Certification System M4 X 0.7 Mounting Hole Positions FM APPROVED CLASS I, DIV I GROUPS B, C AND D CLASS II, DIV I GROUPS E, F AND G NEMA 4X, IP66 CLASS I, DIV I GROUPS B, C AND D CLASS II, DIV I GROUPS E, F AND G NEMA 4X ATEX II 2GD Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 16

MODEL 1080 STAINLESS STEEL EXPLOSION PROOF THERMOCOUPLE HEAD IME Model 1080 Series Stainless Steel Thermocouple Heads are designed specifically for explosion proof applications and constructed out of SS316 Stainless Steel to withstand applications where aggressive atmospheres prevail. This housing accommodates a terminal block or head mounted transmitter 50mm (2.0") in diameter that can be mounted using M4 screws as indicated in the attached drawing. Some units as indicated has a provision for a customer designed SS nameplate with information such as model number, company name, logo, and website etc. Ordering Information for Explosion Proof Heads Model 1080SE 1080SA 1080ST 1080SM FM/CSA Ex-Proof Certified, NEMA 4X, IP66, SS 316 Thermocouple Head, Electro-Polished FM/CSA Ex-Proof Certified, NEMA 4X, IP66, SS 316 Thermocouple Head with Provision for Name Plate, Electro-Polished ATEX / IECEx Ex-Proof Certified, IP68, SS 316 Thermocouple Head with Provision for Name Plate, Electro-Polished FM / CSA / ATEX / IECEx Ex-Proof Certified, NEMA 4X, IP66/68, SS 316 Thermocouple Head with Provision for Name Plate Electro-Polished Code Conduit Size (T1) Instrument Connection (T2) 01 T1=¾" NPT T2=½"NPT 02 T1=½" NPT T2=½"NPT 05 T1=M20X1.5 (See Note 2) T2=½"BSP (See Note 1) 08 T1=M20X1.5 (See Note 2) T2=½"NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify 1080SM - 01 Typical Model Number Note : 1 BSP Thread is not Certified by FM & CSA 2 M20X1.5 is not Certified By CSA Ordering Information for General Purpose Heads Model 1080SN 1080SF 1080SG SS 316 Thermocouple Head with Provision for Name Plate, Electro-Polished SS 316 Thermocouple Head, Electro-Polished (Clear Cover) SS 316 Thermocouple Head with Tempered Glass Window, Electro-Polished Code Conduit Size (T1) Instrument Connection (T2) 01 T1=¾" NPT T2=½"NPT 02 T1=½" NPT T2=½"NPT 05 T1=M20X1.5 T2=½"BSP 08 T1=M20X1.5 T2=½"NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify 1080SN - 01 Typical Model Number 17

MODEL 1088 STAINLESS STEEL EXPLOSION PROOF THERMOCOUPLE HEAD EXPLOSION PROOF CERTIFIED IP68 CONSTRUCTION WIDE SELECTION OF CONDUIT SIZES OPTION FOR A CUSTOMIZED SS NAMEPLATE WIDE RANGE OF ACCESSORIES SUITABLE FOR LARGE DEVICES 64MM(2.5") Specifications Material of Construction: Dimensions Assembly Drawing SS 316, Stainless Steel Certification: ATEX / IECEx Explosion Proof Certified, IP68 Connections ½" NPT, ¾" NPT, ½" BSP, M20x1.5P Mounting Holes See attached drawing Surface Finishing Electro Polish "O" Ring Hydrogenated Nitrile Weight 1.2 KG (2.7 lbs) Accessories SS Ball Chain, Terminal Block(Ceramic/Bakelite, Optional) Custom Designed SS Nameplate M4 X 0.7 Mounting Hole Positions Ordering Information for Explosion Proof Heads Model 1088ST ATEX/IECEx Ex-Proof Certified, IP68, SS 316 Thermocouple Head with Provision for Name Plate, Electro-Polished Code Thread Size 01 T1=¾" NPT T2=½" NPT 02 T1=½" NPT T2=½" NPT 05 T1=M20 x 1.5 T2=½" BSP 08 T1=M20 x 1.5 T2=½" NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify 1088ST - 01 Typical Model Number Ordering Information for General Purpose Heads Model Certification System (For Model 1088ST only) 1088SN SS 316 Thermocouple Head with Provision for Name Plate 1088SF Electro-Polished SS 316 Thermocouple Head, Electro-Polished (Clear Cover) Code Thread Size 01 T1=¾" NPT T2=½" NPT 02 T1=½" NPT T2=½" NPT 05 T1=M20 x 1.5 T2=½" BSP 08 T1=M20 x 1.5 T2=½" NPT 33 T1=¾" NPT T2=¾" NPT XX Specify Specify ATEX II 2GD Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 Ex d IIC Gb Ta = -40 C to 85 C Ex tb IIIC Db IP68 1088SN - 01 Typical Model Number 18

MODEL 1086 LOW COST THERMOCOUPLE HEAD CHOICE OF ALUMINUM OR SS316 CONSTRUCTION PROVISION FOR CUSTOM STAINLESS STEEL NAME PLATE STAINLESS STEEL BALL CHAIN WIDE SELECTION OF CONDUIT SIZES WIDE RANGE OF ACCESSORIES LOW COST Specifications Dimensions Material of Construction: Copper-Free Aluminum or SS316 as specified Certification: None Connections ½" NPT, ¾" NPT, ½" BSP, M20x1.5P Mounting Holes See attached drawing Surface Finishing Silver Paint for Aluminum and Electro-Polish for SS316 unit "O" Ring Nitrile Weight T1 T2 90mm (3.5") M4 X 0.7P Holes 78mm (3.1") 26mm (1.0") 0.25KG (0.55 LBS) for Aluminum Unit and 0.4Kg (0.88 LBS) for SS316 unit Accessories SS Ball Chain, Terminal Block (Ceramic / Bakelite, Optional) Custom Designed Nameplate 33mm (1.3") Order Information Model 1086SR 1086SJ 1086AR Low Cost Stainless Steel Thermocouple Head with Provision for SS Nameplate Low Cost Stainless Steel Thermocouple Head Low Cost Aluminum Thermocouple Head with Provision for SS Nameplate Code Thread Size 01 T1=¾" NPT T2=½"NPT 02 T1=½" NPT T2=½"NPT 05 T1=M20X1.5 T2=½"BSP 08 T1=M20X1.5 T2=½"NPT 33 T1=¾" NPT T2=¾" NPT XX T1=Specify T2=Specify 1086SR 01 Typical Model Number 40mm (1.6") 30mm (1.2") 40mm (1.6") 54mm (2.1") 32mm (1.3") TYPICAL SS NAMEPLATE SUPPLIED BBY IME BASED ON ARTWORK PROVIDED BY CUSTOMER 15mm (0.6") 19

TEMPERATURE SENSOR ACCESSORIES INTERNATIONAL METAL ENGINEERING Spring Loaded Nipple Model 3506 Constructed out of SS316 and suitable for spring loading ¼" sensors and MI cables. Complete assembly comes with self gripping SS spring and SS316 retainer screw which holds the spring in place. Ø=¼" 20mm Thermowell Plug Model 5560, 5563, 5566 51mm 20mm HEX: 22mm A/F Hexagonal solid plugs with 6.0" ball chain attached, suitable for plugging thermowells and other field devices. Choice of 3 different material. M4 x 0.7 Model 5560 5563 5566 Material SS316 Brass SS304 3mm ½" NPT 7m 18mm Compression Fitting Model 8662, 8663, 8664, 8665, 8666, 8667, 8668 This family of SS316 compression fittings is suitable for attaching sensors or MI cables in a variety of applications. Model Process Thread Fitting Diameter Length 8662 1/8-27 NPT 6.35mm(0.25") 33mm(1.3") 8663 1/4-18 NPT 6.35mm(0.25") 38mm(1.5") 8664 1/2-14 NPT 6.35mm(0.25") 45mm(1.75") 8665 1/2-14 NPT 9.5mm(0.375") 45mm(1.75") 8666 1/4-18 NPT 6.0mm(0.24") 38mm(1.5") 8667 1/2-14 NPT 6.0mm(0.24") 45mm(1.75") 8668 1/2-14 NPT 9.0mm(0.35") 45mm(1.75") Welding Nipple Model 3201 Machined from SS316 Bar Stock, this nipple can be welded directly on 1/4"diameter sensors. Process Thread Length 20

TEMPERATURE SENSOR ACCESSORIES Model 5100 3 Piece Female Union HEX: 42mm(1.6")AF 15mm (0.6") HEX: 26mm(1.0")AF This well designed 3 piece female union in SS316 comes with a conical metal seat and is used in conjunction with 2 nipples to provide thermal isolation to the thermocouple head ½"NPT(F) Both Sides 41mm (1.6") Model 5020 L = 2" (50mm) Nipple Model 5030 L = 3" (75mm) Model 5040 L = 4" (100mm) This standard SS316 Nipple comes in a variety of lengths and can be Model 5060 L = 6" (150mm) combined with the Model 5100 Union to meet all Nipple-Union-Nipple 16mm combinations. Pipe Schedule 80 (0.7") OD: Ø22mm(0.8") ½"NPT(M) Both Sides L Model 5330 L = 3" (75mm) Male Union Model 5340 L = 4" (100mm) Model 5350 L = 5" (125mm) This unique 3 piece design combination of union and nipple come in six Model 5360 L = 6" (150mm) different lengths. The inherent advantages of this design over the traditional Model 5370 L = 7" (175mm) Nipple-Union-Nipple design are: Model 5380 L = 8" (200mm) Two NPT connections instead of four Closer control of overall assembly length Pipe Schedule 80 OD: Ø22mm(0.8") Better control of sensor length for spring loading applications Sturdier construction (Schedule 80) ½"NPT(M) 16mm Both Sides Lower cost 0.7" HEX: 42mm(1.6")AF L Model 5200 16mm 0.7" ½"NPT(F) Female Union This Union comes with male thread on one end and a female thread on the other, allowing a variety of combinations and lengths. ½"NPT(M) 63mm (2.5") HEX: 42mm(1.6")AF 21

BAR STOCK THREADED THERMOWELLS MODEL 2080 TAPERED THERMOWELL WITH THREADED CONNECTION 1/2" NPSM 44.5mm(1.75")+"T" "Q" Dia "U" Ø15.9mm(0.625") "H" Bore=6.6mm(0.260") Process Connection "A" MODEL 2081 STEPPED THERMOWELL WITH THREADED CONNECTION 6.4mm(0.25") 44.5mm(1.75")+"T" "U" 1/2" NPSM "Q" Dia 63.5mm(2.5") Ø12.7mm(0.5") "H" Process Connection "A" Bore=6.6mm(0.260") 6.4mm(0.25") MODEL 2082 STRAIGHT THERMOWELL WITH THREADED CONNECTION 44.5mm(1.75")+"T" "U" 1/2" NPSM "Q" Dia "H" Process Connection "A" Bore=6.6mm(0.260") 6.4mm(0.25") Ordering Information Model 2080 2081 2082 Threaded Thermowell, 0.260"Bore, Tapered Stem Threaded Thermowell, 0.260"Bore, Stepped Stem Threaded Thermowell, 0.260"Bore, Straight Stem CODE Process Connection "H" HEX(A/F) "Q" Diameter P1 ½" NPT 1 1/8" 0.670" P2 ¾" NPT 1 1/8" 0.750" P3 1" NPT 1 3/8" 1.000" CODE "T" Lag length 00 None 30 3" 60 6" XX Other (Specify in inches) CODE Material S1 SS304 S2 SS316 BR Brass CS Carbon Steel MN Monel HA Hastelloy C 276 XX Other (Specify) CODE "U" Length L000 Specify in Inch (Example: U065=6.5") 2080 P1 00 S2 L675 TYPICAL MODEL NUMBER 22

FLANGED THERMOWELLS MODEL 2088 FLANGED THERMOWELL, TAPERED STEM 1/2" NPSM 57.2mm(2.25")+"T" "U" "Q" Dia Ø15.9mm(0.625") 32mm(1.25") Dia Bore=6.6mm(0.260") MODEL 2086 FLANGED THERMOWELL, STRAIGHT STEM 57.2mm(2.25")+"T" "U" 6.4mm(0.25") 1/2" NPSM "Q" Dia 32mm(1.25") Dia Bore=6.6mm(0.260") MODEL 2087 FLANGED THERMOWELL, STEPPED STEM 57.2mm(2.25")+"T" "U" 1/2" NPSM "Q" Dia 63.5mm(2.5") 6.4mm(0.25") Ø12.7mm(0.5") 32mm(1.25") Dia Bore=6.6mm(0.260") 6.4mm(0.25") Ordering Information Model 2088 2086 2087 Flanged Thermowell, 0.260"Bore, Tapered Stem, 1.000" Q Diameter Flange Thermowell, 0.260"Bore, Straight Stem, 1.000" Q Diameter Flanged Thermowell, 0.260"Bore, Stepped Stem, 1.000" Q Diameter CODE "P" Pipe Mounting Size P1 ½" P2 ¾" P3 1" P4 1½" P5 2" P6 2½" P7 3" CODE Flange Rating W1 150 LB W2 300 LB W3 600 LB W4 900 LB W5 1500 LB W6 2500 LB CODE "T" Lag length 00 None 30 3" 60 6" XX Other (Specify in inches) CODE Material S1 SS304 S2 SS316 BR Brass CS Carbon Steel MN Monel HA Hastelloy C 276 XX Other (Specify) CODE "U" Length L000 Specify in Inch (Example:065=6.5") 2088 P1 W2 00 S2 L675 TYPICAL MODEL NUMBER 23

INTERNATIONAL METAL ENGINEERING 92 SERIES EXPLOSION PROOF NIPPLE UNION TEMPERATURE ASSEMBLY The 92 series is an ATEX and IECEx approved spring loaded stainless steel Nipple Union Assemblies that can be used with any approved equipment or transmitter that offers at least the same level of protection as detailed at the bottom of this page. This allows the entire assemby to be ATEX and IECEx approved. The assembly has a 1/2" NPT thread at the probe end and a 1/2" NPT or M20 thread at the lead end (thread for flame lock). The probe end of the nipple union is threaded to accommodate an optional protection of the probe such as a thermowell. The 92 series comes with an option for customized stainless steel nameplate that can attached on the union. We can also provide these assemblies with a sensor from any manufacturer of your chioce. See below for ordering information "OAL" LENGTH Thread For Flame Lock "N" LENGTH "A" LENGTH Spring Loaded Nipple Union Nipple Assembly Plain Capsule Sensor Model Explosion Proof Nipple Union Nipple Temperature Assembly 91 General Purpose 92 ATEX & IECEx Approved (See Certification System Below For Details) Code Sensor 1/2" NPT TJ Type J Thermocouple, Class 1, DIN/EC 584-2-1992 TK Type K Thermocouple, Class 1, DIN/EC 584-2-1992 TT Type T Thermocouple, Class 1, DIN/EC 584-2-1992 TE Type E Thermocouple, Class 1, DIN/EC 584-2-1992 TR Type R Thermocouple, Class 1, DIN/EC 584-2-1992 TS Type S Thermocouple, Class 1, DIN/EC 584-2-1992 PA 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 3 Wire PB PF XX 100 Ohm Platinum Resistance Sensor, Class B, DIN/EC 751-1985, 3 Wire 100 Ohm To Platinu Be Specified Code Number of Elements S Single Element D Dual Element Code Nipple Union Nipple Assembly ("N" Length) 02 2 Inch (General Purpose Only) 03 3 Inch (General Purpose Only) 04 4 Inch 05 5 Inch 06 6 Inch 07 7 Inch Code Thread For Flame Lock 001 1/2" NPT 002 M20 x 1.5P Code Sensor Diameter EG 6.4mm MT 6.0mm Code L000 Sensor "A" Length SPECIFY "L" in mm 92 PA S 04 001 EG L120 --- Typical Model Number Certification System II 2G D Exd IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ex d IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C 24

93 SERIES SPRING LOADED STAINLESS STEEL NIPPLE The 93 series are variation of the 92 series where these are the ATEX and IECEx approved spring loaded stainless steel nipple assemblies. This assembly can also be used with any approved equipment or tranmitter that offers at least the same level of protection as detailed at the bottom of the page. This allows the entire assembies to be Atex and IECEx approved. The assembly has a 1/2" NPT thread at the probe end and a 1/2" NPT or M20 thread at the lead end. The probe end of the nipple union is threaded to accommodate an optional protection of the probe such as a thermowell. See below for ordering information. "OAL" LENGTH Thread For Flame Lock "N" LENGTH "A" LENGTH Model Explosion Proof Nipple Union Nipple Temperature Assembly 90 General Purpose 93 Atex & IECEx Approved (See Certification System Below For Details) Code Sensor TJ Type J Thermocouple, Class 1, DIN/EC 584-2-1992 TK Type K Thermocouple, Class 1, DIN/EC 584-2-1992 TT Type T Thermocouple, Class 1, DIN/EC 584-2-1992 Spring TE Type E Thermocouple, Class 1, DIN/EC 584-2-1992 Loaded TR Type R Thermocouple, Class 1, DIN/EC 584-2-1992 Nipple Assembly TS Type S Thermocouple, Class 1, DIN/EC 584-2-1992 PA 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 3 Wire 1/2" NPT Plain Capsule Sensor PB PF XX 100 Ohm Platinum Resistance Sensor, Class B, DIN/EC 751-1985, 3 Wire 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 4 Wire To Be Specified Code Number of Elements S Single Element D Dual Element Code Nipple Assembly ("N" Length) 02 2 Inch (General Purpose Only) 03 3 Inch (General Purpose Only) 04 4 Inch 05 5 Inch 06 6 Inch 07 7 Inch Code 001 002 Thread For Flame Lock 1/2" NPT M20 x 1.5P Code Sensor Diameter EG 6.4mm MT 6.0mm Code L000 Sensor "A" Length SPECIFY "L" in mm 93 PA S 04 001 EG L120 -- Typical Model Number Certification System II 2G D Exd IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ex d IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C 25

98 SERIES TEMPERATURE ASSEMBLY WITH INDICATOR / TRANSMITTER The 98 series are ATEX and IECEx approved temperature assemblies. These temperature assemblies encompasses our 8080KN Battery Operated Digital Temperature Indicator, 8080PR Indicating Temperature Temperature switch with Dual Relays, and our 8080HT Indicating Temperature Trasmitter with Hart. See below for ordering information. ENCLOSURE WITH TRANSMITTER / INDICATOR NIPPLE UNION / NIPPLE FLANGE THERMOWELL PLAIN CAPSULE SENSOR "N" LENGTH "A" LENGTH Model Temperature Assembly 94 General Purpose 98 ATEX & IECEx Approved Assembly (See Certification System Below For Details) Code Sensor TJ Type J Thermocouple, Class 1, DIN/EC 584-2-1992 TK Type K Thermocouple, Class 1, DIN/EC 584-2-1992 TT Type T Thermocouple, Class 1, DIN/EC 584-2-1992 TE Type E Thermocouple, Class 1, DIN/EC 584-2-1992 TR Type R Thermocouple, Class 1, DIN/EC 584-2-1992 TS Type S Thermocouple, Class 1, DIN/EC 584-2-1992 PA 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 3 Wire PB 100 Ohm Platinum Resistance Sensor, Class B, DIN/EC 751-1985, 3 Wire PF 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 4 Wire XX To Be Specified Code Number of Elements S Single Element D Dual Element Code "N" Length 02 2 Inch (General Purpose Only) 03 3 Inch (General Purpose Only) 04 4 Inch 05 5 Inch 06 6 Inch 07 7 Inch Code Transmitter / Indicator Option 8080KN Digital Temperature Indicator (See Page 3 For Details) 8080PR Indicating Temperature Switch with Dual Relays (See Page 4 For Details) 8080HT Indicating Temperature Transmitter with Hart (See Page 8 For Details) xxxxxxx Any Preferred Transmitter Model of Any Make Code Choice Of Enclosure A Die Cast Aluminum, Epoxy Painted T SS316, Electro Polished Code Conduit Entry 01 3/4" NPT 02 1/2" NPT 06 M20x1.5P 23 1/2" BSP Code Nipple Union N Nipple Only (See Model 93 Series) U Nipple Union Nipple Assembly (See Model 92 Series) Code Plain Capsule Sensor Diameter EG 6.4mm MT 6.0mm Code Sensor "A" Length L0000 SPECIFY "A" in mm 98 PA S 05 8080HT A 01 N EG L0120 Typical Model Number Certification System II 2G D Exd IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C Ex d IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C 26

99 SERIES EXPLOSION PROOF TEMPERATURE ASSEMBLY The 99 series ATEX and IECEx approved temperature assemblies incorporate a Thermocouple Head and a head mounted (hockey puck) temperature transmitter or a 6 post ceramic block.the sensor can be from any manufacturer and may include any thermowell (flanged or threaded). The nipple union assembly is then fitted to an IME Model 1080 Thermocouple Head (Aluminum or SS316).Any model head mounted (hockey puck) temperature transmitter that has less than 3 watts power dissipation or a 6 post terminal block is mounted in the Thermocouple Head to complete the approved temperature assembly. See below for ordering information. ENCLOSURE WITH TRANSMITTER OR TERMINAL BLOCK Spring Loaded Nipple Union Nipple Assembly Flange Thermowell Plain Capsule Sensor N" LENGTH "A" LENGTH Model Temperature Assembly 97 General Purpose 99 ATEX & IECEx Approved (See Certification System Below For Details) Code Sensor TJ Type J Thermocouple, Class 1, DIN/EC 584-2-1992 TK Type K Thermocouple, Class 1, DIN/EC 584-2-1992 TT Type T Thermocouple, Class 1, DIN/EC 584-2-1992 TE Type E Thermocouple, Class 1, DIN/EC 584-2-1992 TR Type R Thermocouple, Class 1, DIN/EC 584-2-1992 TS Type S Thermocouple, Class 1, DIN/EC 584-2-1992 PA PB PF XX 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 3 Wire 100 Ohm Platinum Resistance Sensor, Class B, DIN/EC 751-1985, 3 Wire 100 Ohm Platinum Resistance Sensor, Class A, DIN/EC 751-1985, 4 Wire To Be Specified Code S D Number of Elements Single Element Dual Element Code Nipple Union Nipple Assembly ("N" Length) 02 2 Inch (General Purpose Only) 03 3 Inch (General Purpose Only) 04 4 Inch 05 5 Inch 06 6 Inch 07 7 Inch Code Temperature Transmitter Or Terminal Block 8070HN Head Mounted Transmitter (See Page 6 For Details) Head Mounted Transmitter with Hart (See Page 7 For 8070HH Details) xxxxxxx Any Preferred Transmitter Model of Any Make 8070-06 Ceramic Teminal Block with 6 Dual Posts Code A T Choice Of Enclosure Die Cast Aluminum, Epoxy Painted SS316, Electro Polished Code Conduit Entry 01 3/4" NPT 02 1/2" NPT 08 M20x1.5P 37 1/2" BSP 38 3/4"BSP Code Choice of Thermowell Refer to Page 22 & 23 99 PA S 05 8070HN A 01 --- Typical Model Number Certification System II 2G D Exd IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C Ex d IIC T6 Gb Ex tb IIIC T85 C Db, IP68 Ta = -40 C to +70 C 27

NOTES

OUR OTHER PRODUCTS US Sales Office Singapore 11735, Laneview Dr Blk13, Toa Payoh Lorong 8 Houston, Texas 77070 #06-05 Braddell Tech Park Cell: 281-650-6091 Singapore 319261 website: www.intmet.com Tel: +65-63536506 Email: admin@intmet.com Fax: +65-63536281 website: www.intmet.com