Wiring Diagrams DIAGRAM INDEX. POWER SCHEMATICS Figure Number. Label Diagram No. 30HX ALL ALL

Similar documents
Wiring Diagrams DIAGRAM INDEX

Wiring Diagrams (Including Accessories) (50/60 Hz)

30GX AIR-COOLED LIQUID CHILLER

30GX AIR-COOLED LIQUID CHILLER

Controls, Start-Up, Operation, Service, and Troubleshooting

wiring diagrams SINGLE PACKAGE ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

PRODUCT DRAWING WIRING DIAGRAM FIELD CONNECTIONS MILLENNIUM MODEL YT CHILLERS (STYLE J) WITH ELECTRO-MECHANICAL STARTER JOB DATA:

Wiring Diagrams DIAGRAM INDEX POWER SCHEMATICS

WIRING DIAGRAMS FB4C FE4A/FE5A FH4C FV4C FX4D FY5B PF4MA PF4MB LABEL

MODELS YCRL0064, 0074, 0084, 0096, 0118, 0126, 0156, 0177, 0198, 0200, 0230, 0260, 0300, 0345, 0385, 0445, 0530 and YCRL0610 STYLE "A"

WIRING DIAGRAM MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER

McQuay Air Cooled Chiller AWS280A, AWS300A, AWS320A, AWS350A PL

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

WIRING DIAGRAMS FA4C FY4A FC4D FX4C FH4C

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

Co m f o r t Li n k N A V I G A T O R F F

Product Data. Features/Benefits. 30HXA HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz. 75 to 265 Tons (264 to 931 kw)


McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

R-410A 50Hz & 60Hz. Renewal parts /3/ MODELS ONLY. Issue Date: September 07, 2011

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

WIRING DIAGRAM, MILLENNIUM TM MODEL YT (STYLE J) LIQUID CHILLERS GRAPHIC CONTROL CENTER WITH ELECTRO-MECHANICAL STARTER PRODUCT DRAWING JOB DATA:

ELEMENTARY DIAGRAM CONNECTION DIAGRAM CONTROL PANEL AND CONNECTION DIAGRAM SYSTEM WIRING FOR MODELS:

FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS

Installation Instructions

YCAS AIR-COOLED LIQUID CHILLERS YCAS0373 THROUGH YCAS0653 STYLE G (R22) (50 Hz)

Air-Cooled Scroll Compressor Chillers Models AGZ 010A to AGZ 034A Models AGZ 026B to AGZ 130B. Revised Electrical Data Tables.

CHILLER MODEL NO. YS SOLID STATE STARTER, MODEL NO. SSS, L B OPTIONAL FACTORY INSTALLED DISCONNECT SWITCH AMPS OR

Application Engineering

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

FIELD CONNECTIONS MODEL YK CHILLERS (STYLE F AND G) WITH VARIABLE SPEED DRIVE

WIRING DIAGRAMS MODEL YK (STYLE G) LIQUID CHILLERS OPTIVIEW CONTROL CENTER WITH SSS, LV VSD W/ MODBUS, & MV VSD

TON KW 60HZ

Application Engineering

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

YCAL0014E_ - YCAL0124E_ R-22 & HFC-407C STYLE C (60 Hz)

Installation Instructions

Centrifugal Chiller PE046, PE047, PE048, PE050 PEH PF083, PF096, PF105, PF116 PH PHH PL

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision C 06/2017

30HXC WATERCOOLED CONTROLS UPGRADE

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

MODELS YCWS0313, 0373, 0423, 0503, 0563, 0613 AND YCWS0663SC

30HXC WATERCOOLED CONTROLS UPGRADE

Centrifugal Chiller Single Compressor WSC087, TSC087, HSC087 PL

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

CONTROL PANEL OPERATING MANUAL

SPARE PARTS CATALOG OFFICE PRO 18. DocID: 00G00077EB

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Centrifugal Chiller Single Compressor WSC048, WSC050 TSC048, TSC050 HSC048, HSC050 PL

TON KW 60HZ

Vission 20/20 micro-controller. Operation and service manual

CWP-CO / CWP-RC / CWP-HP 02 to 35

Multi-Pak Group Control

SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

Nordson Airless Nozzle Tester

With Starter Information

Basics of Control Components

A WORD ABOUT PROPER GROUNDING

Vission 20/20 micro-controller. Operation and service manual Version 2.6

PRODUCTS: POWER SUPPLY

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

Installation and Start-Up Instructions

Softstarters Type PSS. Softstarters. General information

CORESENSE DIAGNOSTICS FOR STREAM REFRIGERATION COMPRESSORS

Product Data. Features/Benefits. 30GXN,R ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz. 80 to 450 Tons (267 to 1511 kw)

CWP. Cooling Only Version (CO) Condenserless Version (RC) Heat Pump Version (HP) Models 02 to 35. Engineering Data Manual. Water Cooled Water Chillers

Application Engineering Europe

SIGNAL WORDS QUALIFIED PERSON

SECTION MOTOR CONTROL

SPARE PARTS CATALOG OFFICE PRO 24

MODEL 422 Submersible Pump Controller

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

ISSUE DATE JANUARY 1st, 2008 SECTION 5C 240V 1PHASE W/TCU AND VFD

User s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual

A Compact, Liquid-Cooled Variable Speed Drive for High Horsepower Applications

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

McQuay Air-Cooled Reciprocating Chiller ALR

List price 2012 USD A Service manual, CA-UK B Service manual, CIM5-UK C Service manual, CIM6-UK 29.

Starcool Reefer Parts Service Manual, CIM6, Spare part catalog Short Form manual, CIM6, ES. Back plate, evaporator

Installation Instructions

McQuay. Air Cooled Screw Chiller. ALS Vintage B. Last Manufactured: Replacement Parts List No Revision B 05/2016

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

MODELS YCAV0157, 0177, 0187, 0197, 0207, 0227, 0247 AND YCAV0267 STYLE "A"

SPARE PARTS CATALOG OFFICE PRO 60

RVS-DN Instruction Manual

FM200 FLOW/NO-FLOW MONITOR INSTALLATION AND TECHNICAL MANUAL 120 VAC MODEL 6/1/2017

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

Copeland Screw TM Compressors

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

Corp L3 Revised CB17/CBH17 SERIES UNITS SPECIFICATIONS CB17-95V CBH17-95V

Daikin. Magnitude Magnetic Bearing Compressor Centrifugal Chiller. WMC 400D Vintage C. Replacement Parts List No Revision B 10/2015

Transcription:

Wiring Diagrams 30HXA, 30HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz DIAGRAM INDEX POWER SCHEMATICS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 1 500141 206-271 ALL 2 500389 Unit 30HXA,C 076-186 206-271 CONTROL SCHEMATICS Figure Label Diagram Voltage Number No. 30HX 24 3 500143 115,230 4 500142 24 5 500392 115,230 6 500395 COMPONENT ARRANGEMENTS Unit 30HXA,C Voltage Figure Number Label Diagram No. 30HX 076-186 ALL 7 500140 206-271 ALL 8 500396 NOTE: For operating sequence, refer to Controls, Start-Up, Operation, Service, and Troubleshooting literature. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 903 Catalog No. 563-062 Printed in U.S.A. Form 30HX-1W Pg 1 8-97 Replaces: New Tab 5c

LEGEND ALM Alarm C Contactor Compressor CB Circuit Breaker CCN Carrier Comfort Network CFC Condenser Fan Contactor CD WP Condenser Water Pump COMM Communications COMP Compressor COND Condenser CPM Compressor Protection Module CR Control Relay CT Current Transformer CWFS Chilled Water Flow Switch CWP Chilled Water Pump CWPI Chilled Water Pump Interlock DGT Discharge Gas Thermistor DPT Discharge Pressure Transducer DSIO EXV EXV Driver ECWT Entering Chilled Water Temp. EPT Economizer Pressure Transducer EQUIP Equipment EXV Electronic Expansion Valve FB Fuse Block FC Fan Contactor FIOP Factory-Installed Option FU Fuse GND Ground HPS High-Pressure Switch HSIO Keyboard and Display Module HTR Heater I/O Input/Output LCWT Leaving Chilled Water Temp. LDR Loader LID Local Interface Device LL Liquid Level LS Level Switch MLCR Minimum Load Control Relay MLC Minimum Load Control NEC National Electrical Code (U.S.A.) OHR Oil Heater Relay OL Overload OLS Oil Level Switch OP Oil Pump OPC Oil Pump Contactor OPT Oil Pressure Transducer PL Plug Assembly PRI Primary PS Power Supply PSIO Processor Module PWR Power RBPL Relay Board Plug Assembly S Shorting SEC Secondary SN Sensor (Toroid) SPT Suction Pressure Transducer SW Switch T Thermistor TB Terminal Block TEMP Temperature TRAN Transformer XL Across-The-Line Start 1M Wye 2M Delta 4IN/OUT Analog I/O Module Terminal Block Connection Marked Terminal Unmarked Terminal Unmarked Splice Marked Wire Marked Splice Factory Wiring Field Control Wiring Field Power Wiring Indicates Common Potential Does Not Represent Wiring Accessories or Options 1. Three-phase motors protected against primary single phasing conditions. 2. Replacement of original wires must be with type 105 C wire or its equivalent. 3. Numbers on the right side of label diagrams indicate the line location of applicable contacts. An underlined number signifies normally closed contacts; a plain number denotes normally open contacts. Line numbers are shown on the left side of the diagrams. 4. Factory wiring is in accordance with National Electrical Code (NEC) (U.S.A.). Field modifications or additions must be in compliance with all applicable codes. 5. Wiring for main field power supply must be rated 75 C minimum. Use copper conductors for all units. Maximum incoming wire size for each terminal block is 500 kcmil. 6. Power for control circuit should be supplied from a separate source (except 380/415-v units) through a field supplied disconnect with 30 amp maximum protection for 115-v control circuits and 15 amp maximum protection for 230-v control circuit. Connect control circuit power to terminals 1 and 2 of TB4. Connect neutral side of supply to terminal 2 of TB4. Control circuit conductors for all units must be copper only. Control circuit power is factory wired for 380/415-v units. NOTES 7. Terminals 13 and 14 of TB2 are for field external interlock connection for remote ON-OFF and terminals 11 and 12 of TB2 for CWP interlock and CWFS. The contacts must be rated for drycircuit application capable of handling a 24 vac to 50 ma load. Remove jumper between 13 and 14 of TB2 if remote ON-OFF is installed. 8. Separate field-supplied 115-v or 230-v power circuits: Terminals 4 and 5 of TB2 are for control of chilled water pump starter. Terminals 2 and 3 of TB2 are for alarm. The maximum allowable load for each of these circuits is 125 va sealed. 9. Terminal 6 of TB2 is for condenser fan contactor B (HXA) or condenser water pump (HXC). Terminal 1 of TB2 is for condenser fan contactor A (HXA). The maximum allowable load for each of these circuits is 125 va inrush, 125 va sealed. Separate field-supplied power is not required. 2

3 Fig. 1 Power Wiring, 30HX076-186

4 Fig. 1 Power Wiring, 30HX076-186 (cont)

5 Fig. 2 Power Wiring, 30HX206-271

6 Fig. 2 Power Wiring, 30HX206-271 (cont)

Fig. 3 Control Wiring, 24 v, 30HX076-186 7

Fig. 3 Control Wiring, 24 v, 30HX076-186 (cont) 8

9 Fig. 4 Control Wiring, 115 v or 230 v, 30HX076-186

10 Fig. 4 Control Wiring, 115 v or 230 v, 30HX076-186 (cont)

11 PSI Fig. 5 Control Wiring, 24 v, 30HX206-271

12 Fig. 5 Control Wiring, 24 v, 30HX206-271 (cont)

SEE NOTE 7 DSIO (EXV) 13 Fig. 5 Control Wiring, 24 v, 30HX206-271 (cont)

14 Fig. 5 Control Wiring, 24 v, 30HX206-271 (cont)

15 Fig. 6 Control Wiring, 115 v or 230 v, 30HX206-271

16 Fig. 6 Control Wiring, 115 v or 230 v, 30HX206-271 (cont)

17 Fig. 7 Component Arrangement, 30HX076-186

18 Fig. 8 Component Arrangement, 30HX206-271

Copyright 1997 Carrier Corporation Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 PC 903 Catalog No. 563-062 Printed in U.S.A. Form 30HX-1W Pg 20 8-97 Replaces: New Tab 5c