PLAFOND B. Connection cover. lindab we simplify construction

Similar documents
LindabPodium. Supply air beam. lindab we simplify construction

Plenum boxes. About Lindab. Comfort and Design. Product overview / symbols. Theory. Ceiling diffusers. Ceiling diffusers - visible.

Use. Installation. Key figures. Worth noting. linx industries chilled beams

Ventiduct nozzle ducts

Ventiduct nozzle ducts

CCE - Adaptable active chilled beam for exposed installation. Halton CCE. Adaptable active chilled beam for exposed installation

THB - Perforated Ceiling Diffuser. Halton THB. Perforated Ceiling Diffuser

Incorporating V2.0. Product spec >>> > Series DJ - Drum jet diffusers


Front panel Perforated galvanised steel Stainless steel AISI 316 as option Casing Galvanised steel Stainless steel AISI 316 as option

Installation instruction do88 performance Intercooler for Volvo S60/V60 T6 MY10-

Halton Rex 600 RE6 - Adaptable active chilled beam

CBQ Multiservice chilled beam platform for suspended installation

DKR - Multi-nozzle Ceiling Diffuser. Halton DKR. Multi-nozzle Ceiling Diffuser

BRC

Content. Door closer. Overview General information door closer 81 Allocation of sash width to dimension of door closer 82 Adjustment options 82

TRB - Conical Ceiling Diffuser. Halton TRB. Conical Ceiling Diffuser

DKS - Multi-nozzle Ceiling Diffuser. Halton DKS. Multi-nozzle Ceiling Diffuser

Ventilation grilles for installation into walls, sills or rectangular

Disc valves. Type Z-LVS. For supply air. 03/2017 DE/en PD Z-LVS 1

lindab comfort Regula Control er

Ceiling impulse diffuser Model PIL

MODEL 8636 / 8636-LN / 8636-BAC SUREFLOW ROOM PRESSURE CONTROLLER

MODEL 8682 SUREFLOW ADAPTIVE OFFSET CONTROLLER

Total comfort control

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

5. Extruder Assembly

VARIFUEL MAINTENANCE AND REPAIR INSTRUCTIONS

Audi S1 Intake kit. Qty. Description

KGEB Exhaust valve. Specifications. Quick Selection. Product code example Exhaust valve KGEB-100-C Mounting ring KGEZ-01

B12.13 SALTO 4138 FOR SLOPING HEAD WINDOWS

REK, LEK, ROK and LOK

Ceiling swirl diffusers

Handling Arm CHANGING CABLE PROCEDURE USER GUIDE

THL - Conical Ceiling Diffuser. Halton THL. Conical Ceiling Diffuser

Product Data. Features/Benefits. 36CBAC,AE,AF,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

AHF - Exhaust Grille. Halton AHF. Exhaust Grille

Driver Side Support Bracket pictured in "no-tow hook" direction. Reverse direction for tow hook equipped vehicles

Installation instruction do88 Intercooler for SAAB 9-3 1,9 TTiD

Duct System for Danfoss Air Units

REK, LEK, ROK AND LOK

Accessories. Balancing plenum PRI For balancing & equalising the airflow and attenuating the duct noise

Induction terminal units

Ceiling swirl diffusers

Compact Grille Model KG

For installation into ductwork

Installation instruction do88 Intercooler for SAAB 9-3SS/SC 2,8 V6 Turbo

Adriatic for individually suspended installation Exposed active climate beam with cooling, heating and ventilation

Linear Floor Grilles Models FG, F20, F25 and FRO

Guide to Paux System for Motor Caravans Model AS PAUX v. 1.0

Ceiling swirl diffusers

DRUM JET DIFFUSERS TYPE: DJA DJB DJAP DJBP

Cable fixings Information

The Sika Solution x 600 x 700H / 900H. Class D. Roadway Installation Guidelines p 9-11

INSTALLATION MANUAL. Drive line rebuild kit for MF class 8 p/n 13645

EDITION 1/2018 EN SYSTEM PERGOLA PERGOLA SB 500 PERGOLA SB 400 PERGOLA SOLID

INSTALLATION INSTRUCTIONS GRILLE GUARD TOYOTA TUNDRA TOYOTA SEQUOIA PART # 2067/2067-2

Ventilation grilles for installation into walls, sills or rectangular

CAV controllers Type RN

Ventilation grilles for installation into walls, sills or rectangular

DHL - HEPA terminal filter diffuser DHL. HEPA terminal filter diffuser

Cell Ventilation Security Grille

Zoneflow Engineering Installation and Maintenance Manual

CHILLED BEAM IQ STAR WEGA II

P RO W ALL V ENTILATION H OODS INSTALLATION INSTRUCTIONS

Installation instruction do88 Intercooler for SAAB 9-3SS/SC 4-cyl Turbo

EVO 2 FAIRING Rev6 18/05/ :40:00 1

Floor Swirls Models BZD and SZD

Incorporating V2.1. Product spec >>> > Series ECG - Egg crate grilles

Ceiling diffusers. Type VDR. For large temperature differences in heating mode, high penetration of air, with adjustable air control blades

CornerAir. CornerAir. Active chilled beam

KLIMA Active Chilled Beams

Ceiling swirl diffusers with perforated face plate

Accessories. Front vane panel Coupling sleeve with gasket Galvanised steel Gasket of rubber compound

Incorporating V2.0. Product spec >>> > Series NV - Non vision grilles

TOWER BTG CHILLED AND HEATED

A12.11 SALTO 4008 A12 TURN-TILT WINDOWS

C.4.CHRONO TILT AND TURN

Technical Report #67. Failure reasons for oil seals

TBV - Terminal Unit. Halton TBV. Terminal Unit

Swegon PACIFIC. Integrated climate beam

SDV Vane Swirl Diffusers

IQ STAR NOVA II CHILLED BEAM» TECHNICAL DATA

INSTRUCTION MANUAL MAGNA RAIL

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

lindab we simplify construction Plafond Service & maintenance

FrENcH casement windows D11.15 HINGES

Torque specifications Stainless steel ft. lbs Aluminum ft. lbs

SUBJECT: Intermittent Coolant Weepage From Upper Radiator Hose Or Radiator

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

DFA - Conical Ceiling Diffuser. Halton DFA. Conical Ceiling Diffuser

NexT Range Large sheet steel enclosures

Round duct diffuser DBB-RR

CAV controllers. Type RN. For the precise control of constant volume flow rates PD RN 1

C O L M A N. Air Distribution JET DIFFUSERS DCJ SERIES DCJ SERIES

series KLR Linear slot diffusers

LAQ Return air diffuser

PELICAN Ceiling HF. Square extract air diffuser QUICK FACTS

Incorporating V2.0. Product spec >>> > Series DD - Double deflection grilles

FALCON Ceiling. Circular ceiling air diffuser for supply air QUICK FACTS

Transcription:

PLAFOND B 10.2013 Lindab Ventilation A/S. All forms of reproduction without written permission are forbidden. is the registered trademark of Lindab AB. Lindab's products, systems, product and product group designations are protected by intellectual property rights (IPR).

Use s are used to conceil the pipes and ductwork associated with a chilled beam. The connection cover consists of a coverplate, mounted by brackets to the ceiling and the wall. All connection covers are designed to have the same appearance as the chilled beam itself. Installation The length of the connection cover should be sufficient to cover the pipe- and duct installations, but should still leave room for imperfections in the building construction. The connection cover can be ordered for tight installation, with 0 mm gap. But due to the risk of imperfections in the wall or ceiling, we recommend a 10 mm gap between the wall and the cover. The connection cover is ordered by the length of the top beam. Please follow the instructions for correct measurements. Options The connection cover for comes in three standard variants, suitable when no pre-installed piping and ducts interfere with your installation: Left Right center The three variants come in three open bracket version subversions. These are suitable when you need to build around pre-installed piping and ducts. Standard Brackets to support and lock the coverplate. NOTE! Center bracket only needed for covers 1800 mm. Top beam The top beam has two pre-installed plates for connecting the connection cover to the top beam. Plates ready for blind rivets (Not included). Each bracket has a simple locking mechanismn, so the front plate can be easily detached and attached. The connection cover comes with one loose bracket which includes 3 x M6x40 nuts and 3 x M6x12a bolts, ready for mounting on end left bracket of. Detachable coverplate Picture 1. Left standard cover (With closed bracket) 1800 mm. 3

Order code When placing the order for connection covers, please remember to list the order number for the original beam order. Product Plafond conn. cover B x x xxxx xxxx xxxxxx Plafond beam type: B oriontation: L = Left, R = Right, C = Center Bracket type: C = Closed (Only left and right) O = Open (Center always open) length: Distance -10 mm (left/right cover) Distance -1 mm (Center cover) Max. length 3600 mm Colour code: RAL 9010, RAL 9005, RAL 9006, RAL 9003 Standard: RAL 9010 (gloss value 30) Other colors available upon request Original order number for main beam: SO-xxxxxx Example: Plafond conn. cover - B - L - C - 590-9010 - SO-123456 Overview Wall 3 Measuring Top beam Select bracket 1 Select connection cover 2 4

Versions 1 Select bracket 2 Select connection cover 3 orientation Measuring Left Left Open Right Right Center Center Closed 1 Select bracket Open bracket: The open bracket is suitable when you need to build around pre-installed piping and ducts. Closed bracket: The closed bracket most be installed prior to piping and ductwork. Center bracket (always open): The Center bracket is only needed for covers 1800 mm. The connection cover comes with one loose bracket ready for mounting on the beam gable. 5

2 Select connection cover Which side? Left/Right: The connection cover is used between a beam and a wall. Left cover beam Right cover beam 1 Center cover beam 2 Center: The center connection cover is used between two beams and is an open bracket version. Left/Right with gable: The beam is delivered with gables as standard. These gables can be retrofitted to the connection cover, if desired. Left cover beam Gable right The main beam gables should be reused on the connection covers, if applicable. 6

3 Measuring Left/Right cover: Measure the distance between the end of the beams top beam and the wall. (10 mm deduction recommend) IMPORTANT! Before doing any measuring, first check that your beam is installed correctly along leveled lines, that takes into acount the imperfections in ceiling and walls. This will ensure easy measuring and installation of your connection covers. Left cover 10 mm Right cover 10 mm Length NB! The can be ordered for tight installation, with 0 mm gap between wall cover and beam cover. But due to the risk of imperfections in the wall or ceiling, a 10 mm gap between the wall and the cover is recommended. Length Center cover Center cover: Measure the distance between the two ends of the beams top beams. Length top beam 7

www.lindab.com