Horizontal Cartridge DUST COLLECTOR OPF

Similar documents
NCF fans 50 Hz. Protection class IP 55

series RVV Variable flow rate controllers

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

VIRTUO. Comfort ventilation boxes Self-supporting casing with lacquered

Voltage 400V 3N 50Hz. L W H Weight Fans Surface. Air Flow [m 3 /h] Primary [m 2 ] Ø [mm]

19,1 261,0 kw COOLING 23,7 333,0 kw HEATING

NCF 60 Hz. Protection class IP 55

ROOFMASTER STEF-HT ROOF FAN

Dynamically-balanced impellers with extremely robust cores CMP T 5.5

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes

Midea 50Hz AC Fan Coil Unit 2-Pipe Floor-standing Series Technical Service Manual

Product Data Sheet 624 NR. The engineer's choice

Series VENTS OVK. Low pressure axial fans in the steel casing with the air capacity up to m 3 /h for wall mounting

Product Data Sheet DV4118 N

ROOFMASTER STEF-HT ROOF FAN

Multifunctional 400ºC/2h and 300ºC/2h roof fans

High Static Pressure Duct Fan Coil Unit

V.I.R.T.U.O. Ventilation boxes. Comfort ventilation boxes. Use. Range. Design

Technical Information

Chilled Water Vertical Fan Coils

85 db(a) at m³/h. 75 db(a) at 4000 m³/h. 78 db(a) at 3500 m³/h. 69 db(a) at 2500 m³/h. 85 db(a) at m³/h. 74 db(a) at 4000 m³/h

ROOF FAN ROOFMASTER STEC NON-INSULATED VERSION TECHNICAL CATALOGUE

Low Power Consumption Fan 60 mm Sq. 10 mm Thick San Ace 60 9GA Type

AXIAL FANS Catalogue CN0050C01 May 2008

BSB SINGLE INLET BELT DRIVEN CENTRIFUGAL FANS WITH BACKWARD CURVED IMPELLERS

400ºC/2h centrifugal roof fans with horizontal or vertical air outlet CHT 200 4T BS. Installed capacity

Ductable water unit FWD UNT-PRC002-E4

Sabre Plate Mounted Sickle Fans (VSP)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

RADIAL ALUMINUM LOW PRESSURE

DAIKIN INDUSTRIES, LTD. Ceiling Concealed Chilled Water Fan Coil Unit (50Hz/60Hz)

Product Data Sheet 4184 NXHH

TSAT: Single inlet, belt-driven centrifugal fans fitted with electric motors. CJTSA: Ventilation units with a forward-curved impeller.

RADIAL ALUMINUM LOW PRESSURE

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Circular Silencer. Rigid and flexible construction Type CA CB CF CS. TROX GmbH Telephone +49/28 45/ Telefax +49/28 45/

Product Data Sheet 4184 NXHH

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

ACOUSTIC CABINET FANS CENTRIBOX CVB/CVT. Acoustic cabinet fans. Circular duct connection flanges. Flame retardant IP55 remote terminal box

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

ACOUSTIC CABINET FANS CVB / CVT Series

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

Product Data Sheet ACi 4420 MLR

Product Data Sheet 4184 NGX

Product Data Sheet ACi 4420 HHR

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

Performance Data. Fan Performance Curves - FDCLP2 with ECM. Unit Size Unit Size FDCLP2 Fan Curves-1 v001

Tube Fans - ROPERA Range ROPERA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250, 315 and 355.

Ceiling Concealed Chilled Water Fan Coil Unit

Water terminals from 91 to 1548 m 3 /h. from 0,5 to 9,6 kw. SysCoil Comfort. Floor and ceiling fan coil units. from 0,6 to 13,6 kw

Unobox units with backward curved centrifugal impellers

Centrifugal medium-pressure fans fitted with multi-blade

ROOFMASTER STEF-ATEX ROOF FAN

Chiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalogue

Capacity Tables. Cooling Capacity: Cooper&Hunter Wall Mounted FCU

Product Data Sheet 4414/2H

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

HR Combi-line. Heat recovery unit with heat pump on extended AHU base frame. Aluminum anodized Pentapost coldbridge free frame construction

Vent-Axia Sabre Sickle Roof Fans (VSR)

CAS 460 2T 7.5. Impeller size motor poles 2=3500 r/min. 60 Hz. Installed power

NCF fans 60Hz. Protection class IP 55

Product Data Sheet 8314 HR-197

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

Tube Fans - ESPADA Range ESPADA 100 (L) Features. Electrical Supply. Product Code. Sizes 100, 125, 150, 160, 200, 250 and 315

NALSRF BELT DRIVE ACOUSTIC SINGLE EXTERNAL ROOF FANS

FEATURES & BENEFITS UPON REQUEST

Cooling Systems FLKS - 3S/1.0/W... FLKS - 3L/1.0/W DESCRIPTION

METRIC VECO SYNCHRO BELTS Selection of Transmission / 6

Continuous Baseload. Prime Power

product specification

Sabre Sickle Fan Assisted Roof Cowls (VSR)

Product Data Sheet 3214 JH3-195

Rooftop packaged Units

Silent centrifugal air heater hot water supply

HIGH TEMPERATURE TWIN SQUIF FANS

Product Data Sheet 8412 N/ The engineer's choice

CENTRIFLOW 3D WITH AC MOTOR >> Technical catalouge

TECHNICAL INFORMATION

TECHNICAL INFORMATION

THT/HATCH THT/HATCH. Order code THT/HATCH 40 2T 1 N 1 G

FONTECK INDUSTRIES Glasblazerstraat 12E, 2984 BL Ridderkerk, The Netherlands Tel: +31 (0) Fax: +31 (0)

1 AIR HANDLING UNIT TYPE AIR ACCESS 75

CHMT Series, F Rated Fans

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

ROOF FAN ROOFMASTER STEC

AC axial fan. sickled blades (S series) Wall ring with guard grille

Product Data Sheet 4118 N/ The engineer's choice

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

Tangential Fans Series TM and TMt Impeller Diameter 125 and 150 mm (4.92" and 5.9")

Product Data Sheet 8412 NHU-519

Short casing. Long casing (L version) Commercial premises

Product Data Sheet 4184 N/17X. The engineer's choice

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 632 NU-006

Transformer Oil Cooling Solutions

CONTRA ROTATING CASED AXIAL FANS TCBBx2 / TCBTx2 Series

09GDV and 09LDV. Air Cooled Dry coolers and Condensers

4016TAG1A 4016TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Ratings. Basic technical data

Transcription:

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 3000 Weight kg 900 Number of filtering elements nr 4 Filtering surface m² 84 Number of cleaning valves nr 4 1" - 24 V DC Nominal air flow m³/h 3000 Nominal static pressure Pa 3000 Nominal fan power kw 4 db(a) 76

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 3300 Weight kg 1050 Number of filtering elements nr 4 Filtering surface m² 84 Number of cleaning valves nr 4 1" - 24 V DC Nominal air flow m³/h 3300 Nominal static pressure Pa 3340 Nominal fan power kw 5.5

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 4400 Weight kg 1200 Number of filtering elements nr 6 Filtering surface m² 126 Number of cleaning valves nr 6 1" - 24 V DC Nominal air flow m³/h 4400 Nominal static pressure Pa 3190 Nominal fan power kw 5.5

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 6600 Weight kg 1550 Number of filtering elements nr 8 Filtering surface m² 168 Number of cleaning valves nr 8 1" - 24 V DC Nominal air flow m³/h 6600 Nominal static pressure Pa 3190 Nominal fan power kw 7.5

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 8800 Weight kg 1800 Number of filtering elements nr 12 Filtering surface m² 252 Number of cleaning valves nr 12 1" - 24 V DC Nominal air flow m³/h 8800 Nominal static pressure Pa 3920 Nominal fan power kw 15

* The level of sound pressure is affected by the background noise, the reverberation of the environment, the presence of other sonorsources and the positioning of the machine near reflecting surfaces. In the installations common conditions it is necessary to use corrective coefficients. This value depends also from the level of sound pressure of ITEM CODE OPF 11000 Weight kg 2200 Number of filtering elements nr 16 Filtering surface m² 336 Number of cleaning valves nr 16 1" - 24 V DC Nominal air flow m³/h 11000 Nominal static pressure Pa 4280 Nominal fan power kw 18.5