Maintenance and service manual for elevator control valve

Similar documents
Elevator control valve KV 1P KV 1S. Adjustment and maintenance manual

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

CAUTION: The first section of the guide deals with the UP SECTION, while the second deals with the DOWN SECTION.

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The possible problems and causes are listed in likelihood and ease of checking.

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

Troubleshooting The Transmission Hydraulic System

Troubleshooting the Transmission Hydraulic System

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

KRAL Screw Pumps. L Series. Catalog. L Series Edition 05/2011 Subject to change.

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Pilot Operated Pressure Relief Valve Series R5V (Denison)

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Compact Vacuum Ejector

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 4: Hydraulic Drive Systems

Operating instructions Form no safety definitions

PUMP SCPD 56/26 DIN BY-PASS

Directional Control Valve Series D3W Soft Shift

DENISON HYDRAULICS open loop pump controls series P140 A-mod, P260 B-mod service information

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Solenoid valve. Solenoid Coil

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

RUN ACCUM. TOTAL STOP BAT LOW HIGH

Type 6213 EV, 6281 EV

EP1306N 5 Gallon Can Extruder System Rev. A June EP1306N Operation Manual

1-3 RAMP AND TORQUE BOOST EXERCISE OBJECTIVE

Pressure Control Valves. General Description. Specifications. Ordering Information

AAR Manual of Standards and Recommended Practices Brakes and Brake Equipment CODE OF AIR BRAKE SYSTEM TESTS FOR FREIGHT EQUIPMENT SINGLE CAR TEST

Removal and Installation of Fuel Injection Pumps

DENISON HYDRAULICS Premier Series. open circuit pump controls P16 B-mod, P09 A-mod. service information

Seated valves 500 bar

Directional Control Valve Series D1VW

Porta-Punch Manual

Safety Valve HM-SV Installation, maintenance and startup guide

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Flow VA 500/ 520. Flow sensors for compressed air and gases incl. temperature measurement. Verbrauch.

Farval. Dualine Installation System Start-Up. Bulletin DL300 BIJUR DELIMON INTERNATIONAL

HPP06. Hydraulic Powerpack. HYCON A/S Juelstrupparken 11 DK-9530 Støvring Denmark

Hydraulic Breakers HH35. Prior to Operation. From Serial No Revised We thank you for choosing a HYCON breaker.

FPO 80 FPOC FPOS FPON, FPOS Tank truck vane pump

MODELS 9917, , 9946P and 9989 High Pressure Lubrigun Series A

Chapter 5: Flow Valves

Directional Control Valve Series 4D01 (DENISON)

Type 644 and 645 Differential Pressure Pump Governors

Operating Instructions

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Typical Feed Water Heater Isolation System.

BALL VALVES FILTERS TEST POINTS 8

Maintenance and Service Instruction

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

Solenoid Valve ST-SA-series

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

INSTALLATION AND MAINTENANCE OF TOP LOADING ARM

Pilot-Operated Directional Control Valves Series D3 - D11

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

Hydraulic PTO Flow Device

HYDRAULIC HEAVY DUTY

DP5 Pump. 5:1, Air-operated, Heavy Duty, Oil. General. Operation. Technical Data. Installation R1 09/10

HPD Hydraulic Post Driver

PUmP REfEREncE guide Bulletin E

MODEL RCW NON-INTERLOCK PREACTION SYSTEM

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement.

AQUASTAR C6. (Comfort 6000) Next Generation Auto Backwash Valve System. (selectable time-pressure or remote cycle start)

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

RPEW4-10. Functional Description HA /2012. Solenoid Operated Directional Control Valves with Wirebox. Replaces HA /2006

Introduction. General Information. Systems Operation

CENTRO-MATIC PUMP, MODELS 84050, & 85460

JET PUMP INSTALLATION MANUAL. motralec SHALLOW WELL JET PUMPS

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

BR 01b Control valve

A408 GB. Pneumatic oil and diesel pumps 1:1

Series AV2000/3000/4000/5000

Chapter 10: Valves for Pipe Mounting

Torque Converter, Transmission Pump, Screen And Filter

HYDRAULIC ELEVATOR CONTROL VALVES AND POWER UNITS by R. Kirk Muller, Production Manager, Maxton Manufacturing Co.

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Power Valve: Economy Valve. Standard Specifications. Model VEX55-04

ABS Dry Installed Waste Water Pumps Series FR

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Index. UV-7B Sizing Chart UV-7BC Sizing Chart... 17

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

HYDRAULIC TUBE CUTTER

PROPELLER SHAFTS 16-1 PROPELLER SHAFTS CONTENTS

Open Center Compact Valve Custom Installation Guide Rev A

(770) Turning Parts Changers Into TROUBLESHOOTERS!

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Releasable check valve type RH

P.C. Priority Flow Control Valve Series J02D3. General Description

DG 023 DG 024 DG 025 DG 041 DG 042. Clogging Indicators

Transcription:

Maintenance and service manual for elevator control valve EV 100 blain Biofial s.a. Pontou 52 street (behind B K.T.E.O.) P.C. 54628 Thessaloniki Greece Tel: +302310755032 Fax: +302310754929 www.biofial.gr e-mail: biofial@the.forthnet.gr

Elevator control valve EV 100 Blain The Blain EV 100 program includes the widest range of options offered to the elevator industry for high performance passenger service. Easy to install, EV 100's are smooth, reliable and precise in operation throughout extreme load and temperature variations. Description: Available port sizes are 3/4", 1 ½", 2" and 2 ½" pipe threads, depending on flow. EV 100's start on less than minimum load and can be used for across the line or wye-delta starting. According to customers' information, valves are factory adjusted ready for operation and very simple to readjust if so desired. The patented up leveling system combined with compensated pilot control ensure stability of elevator operation and accuracy of stopping independent of wide temperature variations. Technical Data ¾" EV 1 ½" & 2" EV 2 ½" EV Flow Range: l/min Pressure Range: Press. Range UL/CSA: Burst Pressure Z: Pressure Drop P Z: 10-125 (2-33 USgpm) 5-100 bar (74-1500 psi) 5-100 bar (74-1500 psi) 575 bar (8450 psi) 6 (88 psi) at 125 lpm 30-800 (8-208 USgpm) 3-100 bar (44-1500 psi) 3-70 bar (44-1030 psi) 505 bar (7420 psi) 4 (58 psi) at 800 lpm 500-1530 (130-400 USgpm) 3-68 bar (44-1000 psi) 3-47 bar (44-690 psi) 265 bar (3890 psi) 4 (58 psi) at 1530 lpm Weight: kg 5 (11 lbs) 10 (22 lbs) 14 (31 lbs) Oil Viscosity: Max. Oil Temperature: Solenoids AC: Solenoids DC: Insulation Class, AC and DC: 25-60 mm²/sec. at 40 C (15-35 cst. at 120 F). 70 C (158 F) 24 V/1.8 A, 42 V/1.0 A, 110 V/0.43 A, 230 V/0.18 A, 50/60 Hz. 12 V/2.0 A, 24 V/1.1 A, 42 V/0.5 A, 48 V/0.6 A, 80 V/0.3 A, 110 V/0.25 A, 196 V/0.14 A. IP 68

EV 100 valves include the following features essential to efficient installation and trouble-free service: Simple Responsive Adjustment Self Cleaning Pilot Line Filters Temperature and Pressure Compensation Self-Cleaning Main Line Filter (Z-T) Solenoid Connecting Cables Built-in Turbulence Suppressors Pressure Gauge and Shut Off Cock 70 HRc Rockwell Hardened Bore Surfaces Self-Closing Manual Lowering 100% Continuous Duty Solenoids EV 100 has one full speed and one leveling speed per direction, the maximum suggested speed is 1 m/sec. All up and down functions are smooth and adjustable. In the following diagram it is shown the speed variation, the electrical sequence and the available adjustments.

Adjustment and Service of valve EV 100 BLAIN Adjustments Flow control valve EV 100 provides many adjustments in order to accomplish the accurate control of the elevators movement. It has 9 adjustments, which controls the speeds and the accelerations during the up and the down travel. On the right diagram are shown the phases of the movement with the corresponding adjustments. On the photos bellow we can see the position of the adjustments on the valve body. More specific the adjustments are: Adjustment 1 by pass: It defines the time that the pump works while the cabin stands still so the first and the motor accelerate without load. Screwing this time is reduced. Adjustment 2 upward acceleration: It defines the acceleration time to the nominal speed. Screwing the acceleration becomes smoother (acceleration time increase s). Adjustment 3 upward deceleration: It defines the deceleration time from nominal to the leveling speed. Screwing the deceleration becomes smoother (deceleration time increase s) Adjustment 4 upward leveling speed: It defines the upward leveling speed (low up speed). Screwing leveling speed becomes lower. Adjustment 5 up stop: It defines the time that cabin stops from the leveling speed. Screwing the stop becomes smoother (time increases). Adjustment 6 downward acceleration: It defines the acceleration time to the downward speed. Screwing the acceleration becomes smoother (acceleration time increase s). Adjustment 7 downward speed: It defines the cabin s downward speed. Screwing the speed is reduced. Adjustment 8 downward deceleration: It defines cabin s deceleration time from the downward speed to the leveling speed 9

and the final stopping. Screwing the deceleration becomes smoother. Adjustment 9 downward leveling speed: It defines the downward leveling speed. Screwing the speed is reduced. Adjustment S relief pressure: It defines the maximum working pressure in the valve. Screwing the relief pressure increases. In the following diagram it is shown the hydraulic circuit of EV 100: During adjustment of the EV 100 valve, instead of making a full floor to floor travel to check operation, much time can be saved by removing the securing nuts of the coil and switching to deceleration or to acceleration by lifting or replacing the appropriate coil by hand, allowing several adjustment corrections during one car travel between floors. Caution: Once removed from the solenoid tube, the energized coil will begin to overheat after about 20 secs. If necessary, to slow the rate of heating, place an 8 or 10 mm socket key or similar steel rod as core thru the coil. Do not lay an energized coil to one side otherwise it may overheat unnoticed. If the coil becomes too hot to hold, it must be replaced, back over the solenoid tube and any further adjustment carried out with the elevator making normal floor to floor runs. Car not visible from Machine-room If the car cannot be seen during adjustment of the valve, the acceleration and deceleration times can be heard from the change of the turbulent noise within the valve as the speed of the car changes. With no load in the car, the duration of the speed changes should be about 2,5 seconds. This applies to adjustments 2, 3, 6 and 8.

Up Travel (empty car) Pre-settings Adjustment No. 1, level with flange face. Adjustment No. 2, all the way 'in' then 2 turns 'out'. Adjustment No. 3, all the way 'in' then 4 turns 'out'. Adjustment No. 4, level with flange face. Adjustment No. 5, all the way 'in' then 4 turns 'out'. Adjustment No. S, all the way 'in' then 2 turns 'out'. 5 mm Socket key 3 mm Socket key 3 mm Socket key 5 mm Socket key 3 mm Socket key 3 mm Socket key 1. Pilot Pressure Setting: Disconnect coil A. Energize Motor (pump). If the car does not move, turn No. 1 'in' until the car begins to move, turn No. 1 'out' until the car stops, then back out again ½ turn. The car remains standing still. DO NOT UP-LEVEL WITH THIS ADJUSTMENT! Between full and empty car, leveling speed differences would be extreme. 2. Up Acceleration: Reconnect coil A. Start Motor and energize coil A and B (normal 'up' call). Observe the up acceleration. If it is too quick, turn No. 2 'in' ¼ turn. If it is too long, turn No. 2 'out' ¼ turn. Repeat until acceleration is satisfactory. Acceleration time should be about 2,5 secs. 4. Up Leveling: Disconnect coil B. Energize Motor and coil A (normal 'up-level' call). With adjustment No. 4 level with the face of the flange the car will up level. If the leveling speed is too fast, turn No. 4 'in' until the speed is as required. If the speed is too slow, turn No. 4 'out'. Recommended speed: 6 cm/sec. 3. Up Deceleration: With coil B still disconnected. Energize motor and coil A (normal 'up-level' call). The car will travel upwards at leveling speed. Turn No. 3 'in' until the car starts to up level faster, then turn No. 3 'out' until the original leveling speed is observed. Reconnect coil B and place a normal up call. Observe the deceleration of the car. If it is too long, turn No. 3 'out' ¼ turn; if it is too short, turn No. 3 'in' ¼ turn. Repeat until deceleration is satisfactory. Deceleration time should be about 2,5 sec. 5. Up Soft Stop: Disconnect coil A. Energize Motor. The car should not move. Turn No. 5 'in' until the car starts upwards then turn No. 5 'out' until the car stops. Reconnect coil A. Energize Pump-Motor and A. The car will travel upwards at leveling speed. Lift A coil by hand briefly and observe the stopping of the car. If the stop is too hard, turn No. 5 'in' ¼ turn. If the stop is too soft, turn No. 5 'out', % turn. Repeat until the stop is satisfactory. S Pressure Relief Valve: Turn S screw 'out' until about 2 mm of the screw head is showing. Close the ball valve in the cylinder line and open the manual lowering H to lower valve pressure down to zero. Place an up call, energizing motor and coils A and B. The relief pressure will show on the pressure gauge. To increase the relief valve setting, turn S 'in'. To decrease the relief valve setting, turn S 'out', then open the manual lowering for ½ second with the pump still running to release locked-in pressure, before observing the pressure gauge reading.

Down Travel (empty car) Pre-settings Adjustment No. 6, all the way 'in' then 4 turns 'out'. Adjustment No. 7, 3 mm under the flange face. Adjustment No. 8, all the way 'in' then 2 turns 'out'. Adjustment No. 9, level with flange face. 3 mm Socket key 5 mm Socket key 3 mm Socket key 5 mm Socket key 8. Down Deceleration: Place down call (coils C and D energized). As the car approaches full speed, remove coil D by hand briefly from the solenoid and observe the deceleration of the car. If the deceleration is too long, turn No. 8 'out' ¼ turn; if it is too short, turn No. 8 'in' ¼ turn. Repeat until deceleration is satisfactory. Deceleration time should be about 2,5 sec. 6. Down Acceleration: Turn No. 6 all the way 'in'. Place down call (coils C and D energized). The car will not move. Turn No. 6 'out' slowly until the car accelerates downwards. If the acceleration is too long, turn No. 6 'out' ¼ turn. If it is too short, turn No. 6 'in' ¼ turn. Acceleration time should be about 2,5 sec. 7. Down Full Speed: Place down call (coils C and D energized). Observe full down speed. Turn No. 7 'in' for slower, 'out' for faster speed. 9. Down Leveling Speed: Disconnect coil C. Place down call (D energized). Observe down leveling speed. Turn No. 9 'in' for slower, 'out' for a fast down leveling speed. Recommended speed: 6 cm/sec. H Emergency Lowering: The manually operated emergency down speed and the D coil operated down leveling speed are the same. Down Stop: When solenoid D is de-energized with solenoid C remaining deenergized, the car will stop according to the setting of adjustment 8 and no further adjustment will be required. KS Slack Rope Valve: The KS is adjusted with a 3 mm Socket Key by turning the screw K 'in' for higher pressure and 'out' for lower pressure. With K turned all the way 'in', then half a turn back out, the unloaded car should descend when the D solenoid alone is energized. Should the car not descend, K must be backed off until the car just begins to descend, then backed off a further half turn to ensure that with cold oil, the car can be lowered as required.

Troubleshooting: Up Travel * For checking the operation of the solenoids, remove the top nuts. By lifting the solenoids a few millimeters, the magnetic pull of the solenoid can be felt. For testing, the operation of the elevator car can also be controlled by lifting and replacing the coil. Valves are fully adjusted and tested in the factory. Check electrical operation before changing valve setting. Problem Possible cause Recommended 1. Test: Turn adjustment 5 all the way in. If the elevator now starts upwards the problem is at solenoid A. 2. Solenoid A not energized or voltage too low 3. Solenoid A tube not screwed down tight Tighten Solenoid A tube. 4. Solenoid valve A - dirt or Clean or change needle and damage between needle AN and seat. seat AS 5. Adjustment 2 not far enough Turn out adjustment 2. No up-start (Elevator remains at floor) Up-Start, but no Full Speed open. 6. Adjustment 1 too far back (open). Not enough pilot pressure. Turn in adjustment 1 with the pump running. 7. Relief valve is set too low. Set relief valve higher. 8. Adjustment 8 turned in too far (car sits on the buffer). 9. Bypass flow guide is too large. Turn out adjustment 8. Insert smaller bypass flow guide (see flow guide charts at EV catalogue). 10. Pump running in the wrong Install the pump correct. direction. 11. The pump connection flange is Seal the pump connection. leaking excessively. 12. The pump is undersize or Select bigger pump or replace worn. pump. 13. Test: If by turning adjustment 1 with the pump running the pressure does not rise above 5 bar, even with a smaller bypass valve inserted, the problem should be sought at the pump 14. Test: Turn adjustment 3 all the way in. If the elevator now travels upwards at full speed the problem is at solenoid B. 15. Solenoid B not energised or voltage too low. 16. Solenoid B tube not screwed down tight. 17. Solenoid valve B - dirt or damage between needle AN and seat AS. 18. The pump connection flange is leaking excessively Tighten Solenoid B tube. Clean or change needle and seat, Seal the pump connection.

Problem Possible cause Recommended 19. The pump is undersize or Select bigger pump or replace worn. pump. Up-Start, but no Full Speed 20. Test: If by turning adjustment 1, the pressure does not rise above 5 bar, even with a smaller bypass valve inserted, the problem should be sought at the pump 21. Adjustment 1 turned in too far. Turn out adjustment 1. 22. Adjustment 2 turned out too Turn in adjustment 2. Up-Start too hard No deceleration into leveling speed Deceleration into leveling speed but overtravel of floor level Elevator stops before reaching the floor (no leveling) Down Leak Releveling far. 23. 0-Ring UO on Bypass Valve U is leaking. 24. Star to Delta motor switch period is too long. 25. Excessive friction on the guide rails or in the cylinder head. Change 0-Ring see EV Spare Parts List. 0.2-0.3 sec. is sufficient. Cannot be eliminated thru valve adjustment. 26. Solenoid B does not deenergize.. Slow down switch possibly set to high (late). 27. Adjustment 3 turned in too far. Turn out adjustment 3. 28. 0-Ring UO on Bypass Valve U Change 0-Ring, see EV Spare is leaking. Parts List. 29. Solenoid A is de-energized too late 30. Adjustment 5 turned in too far Turn out adjustment 5. 31. Adjustment 1 turned in too far Turn out adjustment 1. 32. Up leveling speed too slow Turn in adjustment 4 to about 12 t/min leveling speed. 33. Solenoid A and B reversed.. 34. Up leveling speed too slow. Turn out adjustment 4. 35. Middle 0-Ring FO of flange 4F is leaking. Change O-Ring, see EV Spare Parts List. 36. Relief valve is set too low. Set relief valve higher. 37. For possible down leakage points, see 'EV Parts List', page 5. 38. Releveling may also occur as hot oil cools down and contracts. Replace one seal point and test before proceeding to the next point of possible leakage, if still necessary. Install an oil cooler

Troubleshooting: Down Travel * For checking the operation of the solenoids, remove the top nuts. By lifting the solenoids a few millimeters, the magnetic pull of the solenoid can be felt. For testing, the operation of the elevator car can also be controlled by lifting and replacing the coil. Valves are fully adjusted and tested in the factory. Check electrical operation before changing valve setting. Problem Possible cause Recommended No Down Start No full speed No down leveling. Elevator stops before floor level No down leveling. Elevator travels thru floor level Elevator sinks quickly 39. Solenoid D not energized or voltage too low. 40. Adjustment 6 turned in too far. Turn out adjustment 6. 41. Adjustment 8 turned out too far. 42. O-Ring UO on Down Valve X is leaking. 43. Solenoid C not energized or voltage too low. Turn in adjustment 8 cautiously. Attention: Danger of traveling through Change O-Ring, see EV Spare Parts List. 44. Adjustment 7 turned in too far. Turn out adjustment 7. 45. Down Valve flow guide too Check insert size (see flow guide small. charts page 12) 46. Solenoid C and D reversed. 47. Solenoid D not energized or voltage too low. 48. Adjustment 9 turned in too far. Turn out adjustment 9 to about 10 ft/min. leveling speed. 49. Spring 9F in adjustment 9 broken. Replace adjustment 9 complete. 50. Adjustment KS turned in too Turn out adjustment KS as far. mentioned before. 51. Adjustment 8 turned in too far. Turn out adjustment 8 about ½ turn. 52. Adjustment 9 turned out too Turn in adjustment 9 to about 10 far. ft/min. leveling speed. 53. Solenoid valve C dirt or damage between needle DN and seat DS. 54. Inner O-Ring FO on flange 7F is leaking. 55. Solenoid D tube not screwed down tight. 56. Adjustment 8 turned in too far. Clean or change needle and seat. Change O-Ring, see EV Spare Parts List. Tighten Solenoid D tube. Turn out adjustment 8 about ½ turn.

Problem Possible cause Recommended Elevator sinks slowly due to inner leakage Manual Lowering Valve not working 57. Solenoid valve D - dirt or damage between needle DN and seat DS. 58. O-Ring XO of Down Valve X is leaking. 59. O-Ring VO of Check Valve V is leaking. 60. O-Ring WO of Leveling Valve W is leaking. 61. Inner O-Ring FO on flange 4F is leaking. 62. O-Ring HO of Manual Lowering H is leaking. 63. Hand-pump leaking. 64. Adjustment 8M turned in too far. Clean or change needle and seat. Change O-Ring, see EV Spare Parts List. When Down Valve is compensated, replace Down Valve. Change O-Ring, see EV Spare Parts list. Change Check Valve, see EV Spare Parts List. Replace Manual Lowering. Remove suction tube and observe if hand-pump leaks. Replace complete hand-pump. Turn out adjustment 8. 65. Manual Lowering is leaking. Replace Manual Lowering. 66. Contraction of oil during cooling especially from above Install an oil cooler 35 C. 67. Check 50,39,40 68. Static pressure to low 69. Solenoid D (12V) not energized or voltage too low.. Check battery and replace

EV 100 Spare part list In case of down leakage replace the parts and test with the following order DS & DN, XO, VO, WO, FO and HO No Item FS Lock Screw - Flange FO O-Ring - Flange 1F Flange - By Pass EO O-Ring Adjustment 1 1E Adjustment - By Pass UO O-Ring - By Pass Valve U By Pass Valve UD Noise Suppressor UF Spring - By Pass 2 2 Adjustment - Up Acceleration 3 3 Adjustment - Up Deceleration EO O-Ring Adjustment 4E Adjustment - Up Leveling 4F Flange - Check Valve FO O-Ring - Flange VF Spring - Check Valve 4 W Up-Leveling Valve WO O-Ring - Up Leveling Valve VO Seal - Check Valve V Check valve W6 Screw - Check Valve 5 3 Adjustment - Up Stop 6 3 Adjustment - Down Acceleration 7F Flange - Down Valve FO O-Ring - Flange 7O O-Ring -Adjustment 7E Adjustment - Down Valve 7 UO O-Ring - Down Valve XO Seal - Down Valve X Down valve XD Noise Suppressor F Main Filter 8 8 Adjustment - Down Deceleration 9 H S A+B C+D EO 9E 9F Y H HO SE SM MS SO SZ SF SK MM AD M. AR MO AN AF AH AS MM M DR MO DF DN DK DG FD DS 0-Ring -Adjustment Adjustment - Down Leveling Spring - Down Valve Down Leveling Valve Manual Lowering - Self Closing Seal -Manual Lowering Adjustment - Screw Hexagonal Grub Screw 0-Ring - Nipple Nipple Spring Piston Nut - Solenoid Collar - Solenoid Coil -Solenoid (indicate voltage) Tube - Solenoid 'Up' O-Ring - Solenoid Needle - 'Up' Spring -Solenoid 'Up' Seat Housing - 'Up' S eat - Solenoid Up Nut - Solenoid Coil -Solenoid (indicate voltage) Tube - Solenoid 'Down' O-Ring - Solenoid Spring - Solenoid 'Down' Needle - 'Down Core - Solenoid Seat Housing with Screen-'Down' Filter Solenoid Seat - Solenoid 'Down' Some parts occur more than once in different positions of the valve. O-Ring-Size EV ¾ 1 1 ½ FO 26x2P 47x2.5P 58x3P * EO 9x2P 9x2P 9x2P UO 26x2V 39.34x2.62V 58x3V WO 5.28x1.78V 5.28x1.78V 5.28x1.78V VO 23x2,5V 42x3V 6Ox3V** 70 5.28x1.78P 9x2P 9x2P XO 13x2V 3Ox3V 47x3V HO 5.28~1.78V 5.28~1.78V 5.28~1.78V SO 5.28x1.78P 5.28x1.78P 5.28x1.78P MO 26x2P 26x2P 26x2P

Adjustment of rupture valve R10 Blain The rupture valve should shut off the oil s flow when the lowering speed of the elevator becomes 0,3 m/sec higher than the nominal. To find the cut off flow: Q c = (v + 0,3) * Q / v V the elevator s speed Q the nominal speed of the pump Example : v = 0,64 m/sec Q = 100 l/min Q c = (0,64 + 0,3) * 100 / 0,64 = 146 l/min To adjust the rupture valve we use the following diagram, for the example above the h must be set on 19 mm