Specification Grade Insulated Bushings...DA1 Specification Grade Insulated Grounding Bushings...DA2-DA4. Insulating Bushings & Couplings...

Similar documents
Conduit Bushings for Rigid Metal Conduit and IMC

General Cable Support Information

Cable Supports. Requirements for Cable Supports in the National Electrical Code reads as follows:

Cable Connectors & Conduit Sealing Bushings

Spec 5 Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Form 35 Malleable Iron Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Cable Connectors & Conduit Sealing Bushings

COMMERCIAL AND INDUSTRIAL FITTINGS: CONDUIT BODIES. Applications

Form 85 Unilets Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum, IMC, and EMT Conduit.

BUB400M 4-In Mog Cond Body. Features. Material, Color, and Finish. Dimensions and Weight

Liquid Tight. Liquid Tight Connectors Reusable Fittings. Straight Connectors. Straight Connectors with Insulated Throat

Aluminum Conduit Bodies, Covers and Gaskets For Rigid Conduit & IMC.

Product Specification Guide Expansion and Deflection Couplings. SECTION Raceway and Boxes for Electrical Systems

Conductor Size 18 TO 8 AWG, 6 TO 0 AWG, 2/0 TO 4/0 AWG, 4/0 AWG TO 750 MCM (ALUMINUM/COPPER CLAD, ALUMINUM/COPPER)

LB125A 1-1/4" LB Form 5 Aluminum Conduit Body. Dimensions and Weight STUD SIZE #10; 0.97 INCH LENGTH; INSULATION SUPPORT

americanfittingscorp.com t: e:

T38 1" T Form 7 Malleable Iron Conduit Body. Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Rigid Metal Conduit, IMC or EMT K-Clamps

320A Single Phase URD Meter Loop Installations

CABLE GRIPS Strain-Relief Grips Pulling Grips Support Grips

Form 7 Iron Conduit Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Armoured Cable/Flex. Conduit

Number Tube I.P.S. Rod Size or O.D. Range Cable H J W

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Commercial Products. New Products in the Commercial Products Product Line

Product Description. Junction Boxes...V1-V23 Meter and Instrument Enclosures...V24-V33

Non-Metallic, Armored Cable, and Flexible Metallic Conduit Fittings

Wire Mesh Safety Grips

CP Myers Hubs. Class I, Div. 2 Class II, Div. 1 and 2 Class III. when installed in accordance with the NEC. Features. Material.

Conduit Outlet Boxes and Bodies: Malleable Iron or Aluminum; Explosionproof, Dust-Ignitionproof UNILETS for use with Threaded Metal Conduit.

AMERICAN FITTINGS Corporation

Material, Color, and Finish Color Gray 0 Zinc Electroplate/Chromate/Epoxy Powder Coat

1-1/2 AL LB FM7 CND BD. Features. Material, Color, and Finish. Dimensions and Weight. Descriptions. Manufacturer Information

Aluminium Conduit. Kopex Martel. Fittings. Liquid Tight Fittings Coupler Connector. PVC Coated Conduit. Fittings. Egatu

AC Line / Load Reactors

FM8 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

Wire Mesh Safety Grips

PRODUCT CATALOG. 2010, Halex/Scott Fetzer Company TABLE OF CONTENTS. LIQUID Liquid-Tight Conduit Fittings

Industrial Areamaster LED Flood/High Bay Luminaires For Ordinary Locations. 250 W, 400 W, 750 W HID Light Level Equivalent

Thin Wall Conduit Fittings (For EMT Conduit)

FM7 Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC Conduit.

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

SUBMITTAL TRANSMITTAL OCPS CLAY SPRINGS ES REVIEWED SUBMITTAL NUMBER: SUBMITTAL DETAILS: CONTRACTOR/CM:


Product Catalog. Rev. 612 r1

SECTION. Watertight & Dust-Tight Plugs & Connectors

Generator Fire Safety: Generator assemblies should be located outside the building.

EY, EYD, & ENY Series

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

1E EJB Junction Boxes Cl. I, Div. 1 and 2, Groups B, C, D

DEMANDING CONDITIONS, DEMAND THE BEST!

Taxonomies, Classifications, and Categories MYER'S HUB, 3-PIECE COUPLINGS, THREADLESS COUPLINGS AND THREADLESS CONNECTORS

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Series 2, 3, 4, & 5 Aluminum - Accessories

ELECTRICAL CONDUIT. EMT IMC Rigid Aluminum

Series 2, 3, 4, & 5 Aluminum - Accessories

Kruppsconduit. Metal Raceway Product Range

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

CONDUIT BODIES CONDUIT BODIES. Phone:

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

Cam-Lok Single Pole Connectors

Applications. Separate sealing chamber and switch construction. Used on 20 Amp 4-way and all 30 Amp models.

25 Sign / Wall Lighter 4324 LED Series Extruded Aluminum, PicoPrism LED revision 9/9/15 kl_4324led_series_spec.pdf

35-kV Thru-Bushings F Series (bolt-in) for Air-Insulated to Air-Insulated Service 200 Amp, 600 Amp, 900 Amp and 1250 Amp

Grounding Accessories

Series 2, 3, 4, & 5 Steel - Accessories

CONTROLS: NEC/CEC EXPLOSIONPROOF CONTROL STATIONS AND SWITCHES. Applications. Illustrated Features

UNDERGROUND SERVICES - SECONDARY

Bulletin 1494F Fixed-Depth Flange-Mounted Disconnect Switches. Selection Guide

THREE PHASE MOTORS RIGID BASE GENERAL PURPOSE Rigid Base

AMENDMENT ELECTRIC SERVICE MANUAL 2014

STRAIGHT BLADE PLUGS & CONNECTORS

Corrosion Protection for Electrical Conduit and Fittings

Bulletin 1494V Variable-Depth Flange-Mounted Circuit Breaker Operating Mechanism

ANAMET Electrical, Inc. Worldwide Leader in Flexible Conduit Technology

VD0C06N908C July 1998 Raleigh, NC, USA. Instruction Bulletin ALTIVAR 66, ALTIVAR 58, ALTIVAR 18. Dynamic Braking Resistor Kit User s Manual

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

W-Series Junction Boxes

MTE AC Line / Load Reactors Price book

Fuse & Switch. BUCHANAN Terminal Blocks. Product Facts High Density Blocks. Fuse Blocks. Switch Blocks. Common Features of 300 & 0300 Series

A/C Disconnects. Only $7.99 each In cases of (6) B222-60NF In cases of (10)

GROUNDING & BONDING PRODUCTS

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Ground Connectors All Copper Alloy Specification Grade

Engineered installation products Solutions for control panel applications

EFS Non-Sealed Tumbler Switches Explosionproof, Dust-Ignitionproof Malleable Iron Body and Cover. Furnished with Internal Ground Screw.

SECTION BASIC ELECTRICAL REQUIREMENTS

Powertite Series Pin and Sleeve Plugs, Connectors and Receptacles

One Circuit Trac System TRAC SECTION, JOINERS & FEEDS T Series

RELOC Modular Wiring Specialty Lighting and Power Systems

180VC WITH B5 FLANGE / M ,6 0, / M l 5,0 0,7 192 / M ,0 0,9 223

Fuseholders Enclosed Fuseholders > Circuit Board Mounted. Shock-Safe Holder (Circuit Board Mounted) Product Characteristics.

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-Hazardous Areas

Disconnect & ByPass Switches

Series 2, 3, 4, & 5 Aluminum - Straight Sections

DC MOTORS NEMA FRAME SCR RATED

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Transcription:

SECTION D INDEX Product Description Page Number Specification Grade Insulated Bushings.....................DA Specification Grade Insulated Grounding Bushings........DA2-DA4 Insulating Bushings & Couplings.......................DA-DA6 Insulating Bushings.....................................DB Insulated Bushings.....................................DB2 Grounding Insulated Bushings........................DB-DB4 Conduit Bushings/Locknuts...........................DB-DB Bonding Wedge Locknuts & Sealing Locknuts................DB8 Reducing Washers.....................................DB9 0 N. Frontage Road Skokie, Illinois 600

Notes 0 N. Frontage Road Skokie, Illinois 600

DA O-Z Specification Bushings Specification Grade Insulated Bushings For Rigid Metal Conduit, IMC & EMT DA Types B, HB, AB, RB, SB, SBT To protect insulated conductors from abrasion during pulling and from mechanical vibration. To provide voltage gradient between live conductors and ground at point of electrical and mechanical stress on conductor insulation. Type B Type SB Molded-on high impact phenolic thermosetting insulation UL insulation temperature rating 0 C Positive metallic conduit stop For threaded rigid and IMC Type B: Malleable Iron or Steel/Zinc Plated Type HB: Malleable Iron or Steel Mechanical/Hot Dip Galvanized Type AB: Aluminum Bushing Type RB: Bronze, for highly corrosive atmospheres For threadless rigid and IMC Type SB: Malleable Iron or Steel/Zinc Plated For EMT Type SBT: Malleable Iron or Steel/Zinc Plated Options: Type B insulated bushings are also available for threadless rigid and IMC in the following materials: Type HSB:Malleable Iron or Steel Mechanical/Hot Dip Galvanized Type ASB: Aluminum Type RSB: Bronze UL Listed: E-8 CSA Certified: 84 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Threaded for Rigid Conduit Threadless Rigid & IMC EMT Catalog Numbers Catalog Numbers Catalog Numbers Trade Hot Dip/ Copper Malleable Iron Malleable Iron Size Zinc Mechanical Free or Steel/ or Steel/ (inches) Plated Galvanized Aluminum Bronze Zinc Plated Zinc Plated B-0 - HB-0 AB-0 RB-0 SB-0 SBT-0 B- HB- AB- RB- SB- SBT- B-00 HB-00 AB-00 RB-00 SB-00 SBT-00 B-2 HB-2 AB-2 RB-2 SB-2 SBT-2 B-0 HB-0 AB-0 RB-0 SB-0 SBT-0 2 B-200 HB-200 AB-200 RB-200 SB-200 SBT-200 2 B-20 HB-20 AB-20 RB-20 SB-20 SB-20 B-00 HB-00 AB-00 RB-00 SB-00 SB-00 B-0 HB-0 AB-0 RB-0B SB-0 SB-0 4 B-400 HB-400 AB-400 RB-400 SB-400 SB-400 B-00 HB-00 AB-00 RB-00 SB-00 6 B-600 HB-600 AB-600 HB-600 SB-600 Note: A Mechanically Galvanized finish provides a plating thickness equivalent to Hot-Dip process, meeting ASTM A- performance criteria. Unlike the Hot-Dip process, mechanical galvanizing provides plating on all machined and/or threaded surfaces. 2 Caps to prevent entry of foreign matter into conduit prior to pulling cables are available. See Type PPC on page DB. Suggested Specification: O-Z/Gedney Type B insulated bushings of malleable iron or steel, with conduit end stop and integrally molded noncombustible phenolic insulated surfaces rated 0 C shall be used on the ends of all raceways containing No. 4 or larger conductors. Trade Dimensions in Inches Size Max. Overall (inches) Dia. Height 2 2 2 2 2 4 4 4 6 6 0 N. Frontage Road Skokie, Illinois 600

DA2 O-Z Specification Bushings DA2 Specification Grade Insulated Grounding Bushings For Rigid Metal Conduit & IMC Type BLG & Type HBLG Copper Plus Lay-In-Lug To provide a compact means of grounding conduit through an Insulated Bushing. To protect insulated conductors from abrasion during pulling and mechanical vibration. To provide voltage gradient between line conductors and ground at point of electrical and mechanical stress on conductor insulation. Tin plated copper saddle for use with copper or aluminum conductors through 4/0. Allows easy insertion of grounding conductor for thru or end connection. Low grounding connector profile. Spring action design maintains positive firm contact on grounding conductor. Set screw provides fixed alignment and positive ground continuity. Phenolic insulation, with 0 C U.L. rating, molded on over metallic conduit stop will not shatter or shrink at sub-zero temperatures. Lugs not sold separately. Type BLG: Malleable Iron or Steel, Zinc Plated Type HBLG: Malleable Iron or Steel, Mechanically/Hot Dip Galvanized with Stainless Steel screws. Options: Type BLG grounding bushings are also available for use on threadless conduit in Malleable Iron/Hot Dip Mechanically Galvanized - Specify Type HSBLG. Contact your local representative for pricing and availability. UL Listed E-24264 CSA Certified:98 UL Standard: 4B, 46 CSA Standard: C22.2 No. 4 NEMA: FB- Suggested Specifications: O-Z/Gedney Type BLG insulated Lay-in-Lug grounding bushings with tin-plated copper grounding path shall be used on all feeder raceways and bushings shall have integrally molded noncombustible insulated surfaces rated 0 C. Notes: A Mechanically Galvanized finish provides a plating thickness equivalent to Hot-Dip process, meeting ASTM A- performance criteria. Unlike the Hot-Dip process, mechanical galvanizing provides plating on all machined and/or threaded surfaces. 2 Caps to prevent entry of foreign matter into conduit prior to pulling cables are available. See Type PPC on Page DB. PATENTED Hot Dip/ Zinc Mechanical Dimensions in Inches Plated Galvanized Max. Turning Trade Size Catalog Catalog Grounding Wire Size* Dia. Max. Radius (inches) Number Number Min. Max. without lug Ht. with lug BLG-004 HBLG-004 4 4 BLG-022 HBLG--022 8 2/0 BLG-004 HBLG-004 4 4 BLG-022 HBLG-022 8 2/0 BLG-04 HBLG-04 4 4 BLG-22 HBLG-22 8 2/0 BLG-204 HBLG-204 4 4 2 BLG-222 HBLG-222 8 2/0 2 BLG-04 HBLG-04 4 4 2 BLG-22 HBLG-22 8 2/0 2 2 BLG-2004 HBLG-2004 4 4 2 2 BLG-2022 HBLG-2022 8 2/0 2 Type BLG 2 2 2 BLG-2604 HBLG-2604 4 4 2 2 BLG-2622 HBLG-2622 8 2/0 2 2 BLG-2624 HBLG-2624 6 4/0 2 2 BLG-260 HBLG-260 20 00 6 BLG-04 HBLG-04 4 4 4 2 BLG-22 HBLG-22 8 2/0 4 2 BLG-24 HBLG-24 6 4/0 4 BLG-0 HBLG-0 20 00 4 BLG-604 HBLG-604 4 4 4 2 BLG-622 HBLG-622 8 2/0 4 BLG-624 HBLG-624 6 4/0 4 BLG-60 HBLG-60 20 00 4 4 4 BLG-404 HBLG-404 4 4 4 BLG-422 HBLG-422 8 2/0 4 BLG-424 HBLG-424 6 4/0 4 BLG-40 HBLG-40 20 00 4 BLG-04 HBLG-04 4 4 6 BLG-22 HBLG-22 8 2/0 6 4 BLG-24 HBLG-24 6 4/0 6 4 BLG-0 HBLG-0 20 00 6 6 BLG-604 HBLG-604 4 4 4 6 BLG-622 HBLG-622 8 2/0 4 6 BLG-624 HBLG-624 6 4/0 4 6 BLG-60 HBLG-60 20 00 6 *Solid or stranded for No. 4 awg or smaller; stranded for No. 2 or larger. Copper conductor only for #4-4 lug and 20-00 mcm lug. 0 N. Frontage Road Skokie, Illinois 600

DA O-Z Specification Bushings DA Specification Grade Insulated Grounding Bushings For Threaded Rigid Conduit & IMC Type ABLG & Type RBLG Copper Plus Lay-In-Lug To provide a compact means of grounding conduit through an Insulated Bushing. To protect insulated conductors from abrasion during pulling and mechanical vibration. To provide voltage gradient between line conductors and ground at point of electrical and mechanical stress on conductor insulation. Tin plated copper saddle for use with copper or aluminum conductors through 4/0. Allows easy insertion of grounding conductor for thru or end connection. Low grounding connector profile. Spring action design maintains positive firm contact on grounding conductor. Set screw provides fixed alignment and positive ground continuity. Phenolic insulation, with 0 C U.L. rating, molded on over metallic conduit stop will not shatter or shrink at sub-zero temperatures. Lugs not sold separately. Type ABLG Aluminum Bushing Type RBLG Bronze Bushing Options: Type ABLG grounding bushings are also available for threadless conduit in bronze and/or aluminum. Specify: Type RSBLG for bronze bushings or Type ASBLG for aluminum bushings. Contact your local representative for pricing and availability. UL Listed: E-24264 CSA Certified: 98 UL Standard: 4B, 46 CSA Standard: C22.2 No. 4 NEMA: FB- Suggested Specifications: O-Z/Gedney Type BLG insulated Lay-in-Lug grounding bushings with tin-plated copper grounding path shall be used on all feeder raceways and bushings shall have integrally molded noncombustible insulated surfaces rated 0 C. Notes: Caps to prevent entry of foreign matter into conduit prior to pulling cables are available. See Type PPC on Page DB. PATENTED Copper Free Dimensions in Inches Aluminum Bronze Max. Turning Trade Size Catalog Catalog Grounding Wire Size* Dia. Max. Radius (inches) Number Number Min. Max. without lug Ht. with lug ABLG-004 RBLG-004 4 4 ABLG-022 RBLG-022 8 2/0 ABLG-004 RBLG-004 4 4 ABLG-022 RBLG-022 8 2/0 ABLG-04 RBLG-04 4 4 ABLG-22 RBLG-22 8 2/0 ABLG-204 RBLG-204 4 4 2 ABLG-222 RBLG-222 8 2/0 2 ABLG-04 RBLG-04 4 4 2 ABLG-22 RBLG-22 8 2/0 2 2 ABLG-2004 RBLG-2004 4 4 2 2 ABLG-2022 RBLG-2022 8 2/0 2 Type ABLG 2 2 2 ABLG-2604 RBLG-2604 4 4 2 2 ABLG-2622 RBLG-2622 8 2/0 2 2 ABLG-2624 RBLG-2624 6 4/0 2 2 -- RBLG-260 20 00 6 ABLG-04 RBLG-04 4 4 4 2 ABLG-22 RBLG-22 8 2/0 4 2 ABLG-24 RBLG-24 6 4/0 4 -- RBLG-0 20 00 4 ABLG-604 RBLG-604 4 4 4 2 ABLG-622 RBLG-622 8 2/0 4 ABLG-624 RBLG624 6 4/0 4 -- RBLG-60 20 00 4 4 4 ABLG-404 RBLG-404 4 4 4 ABLG-422 RBLG-422 8 2/0 4 ABLG-424 RBLG-424 6 4/0 4 -- RBLG-40 20 00 4 ABLG-04 RBLG-04 4 4 6 ABLG-22 RBLG-22 8 2/0 6 4 ABLG-24 RBLG-24 6 4/0 6 4 -- RBLG-0 20 00 6 6 ABLG-604 RBLG-604 4 4 4 6 ABLG-622 RBLG-622 8 2/0 4 6 ABLG-624 RBLG-624 6 4/0 4 6 -- RBLG-60 20 00 6 *Solid or stranded for No. 4 awg or smaller; stranded for No. 2 or larger. Copper conductor only for #4-4 lug and 20-00 mcm lug. 0 N. Frontage Road Skokie, Illinois 600

DA4 O-Z Specification Bushings DA4 Specification Grade Insulated Grounding Bushings For Threadless Rigid Conduit & IMC Type SBLG Copper Plus Lay-In-Lug Provides a compact means of grounding conduit through an insulated bushing. Protects insulated conductors from abrasion during pulling and mechanical vibration. Provides voltage gradient between line conductors and ground at point of electrical and mechanical stress on conductor insulation. Tin plated copper saddle for use with copper or aluminum conductors. Allows easy insertion of grounding conductor for thru or end connection. Low grounding connector profile. Spring action design maintains positive firm contact on grounding conductor. Set screw provides fixed alignment and positive ground continuity. Phenolic insulation, with 0 C UL rating, molded on over metallic conduit stop will not shatter or shrink at sub-zero temperatures. Lugs not sold separately. Bushings - Malleable Iron or Steel/Zinc Plated Grounding Saddle - Tin Plated Copper Clamping Tension Body - Stainless Steel UL Listed: E-24264 CSA Certified: 98 UL Standard: 4B, 46 CSA Standard: C22.2 No. 4 NEMA: FB- Suggested Specifications: O-Z/Gedney Type SBLG insulated Lay-in-Lug grounding bushings with tin-plated copper grounding path shall be used on all feeder raceways and conduits entering enclosures. The bushings shall have integrally molded non combustible insulated surfaces rated 0 C. Notes: A Mechanically Galvanized finish is available that will provide plating thickness equivalent to Hot-Dip process, meeting ASTM A- performance criteria. Unlike the Hot-Dip process, mechanical galvanizing provides plating on all machined and/or threaded surfaces. 2 Caps to prevent entry of foreign matter into conduit prior to pulling cables are available. See Type PPC on page DB. PATENTED Threadless Rigid Dimensions in Inches and IMC Max. Turning Trade Size Catalog Grounding Wire Size* Dia. Max. Radius (inches) Number Min. Max. without lug Ht. with lug SBLG-004 4 4 SBLG-022 8 2/0 SBLG-004 4 4 SBLG-022 8 2/0 SBLG-04 4 4 SBLG-22 8 2/0 SBLG-204 4 4 2 SBLG-222 8 2/0 2 SBLG-04 4 4 2 SBLG-22 8 2/0 2 2 SBLG-2004 4 4 2 2 SBLG-2022 8 2/0 2 Type SBLG 2 2 2 SBLG-2604 4 4 2 2 SBLG-2622 8 2/0 2 2 SBLG-2624 6 4/0 2 SBLG-04 4 4 4 2 SBLG-22 8 2/0 4 2 SBLG-24 6 4/0 4 SBLG-604 4 4 4 2 SBLG-622 8 2/0 4 SBLG-624 6 4/0 4 4 SBLG-404 4 4 4 SBLG-422 8 2/0 4 SBLG-424 6 4/0 SBLG-04 4 4 6 SBLG-22 8 2/0 6 4 SBLG-24 6 4/0 6 4 6 SBLG-604 4 4 4 6 SBLG-622 8 2/0 4 6 SBLG-624 6 4/0 4 *Solid or stranded for No. 4 awg or smaller; stranded for No. 2 or larger. Copper conductor only for #4-4 lug. 0 N. Frontage Road Skokie, Illinois 600

DA Insulating Bushings For Threaded Rigid Conduit & IMC O-Z Specification Bushings DA High impact thermosetting phenolic bushings, with at 0 C UL temperature rating, that will not soften, melt or burn. Type A To insulate end of threaded rigid and IMC UL Listed: E-8 CSA Certified: 84 Type A Trade Type A Dimensions in Inches Size Catalog Outside Overall (inches) Number Dia. Height A-0 Type BB Trade Type BB Dimensions in Inches Size Catalog Outside Bushing Hole Thread (inches) Number Dia. Dia. Length BB-0 Type BB To insulate cables passing through metal boxes or troughs UL Listed: E-209 Type BBL CSA Certified:84 Type BB provided with a locknut A- A-00 A-2 2 A-0 2 2 A-200 2 2 A-20 A-00 4 A-0 4 4 A-400 A-00 6 6 A-600 Dimensions in Inches Trade Type BBL Bushing Locknut Size Catalog Outside Hole Thread Max (inches) Number Dia. Dia. Length Dia. BBL-0 BBL- BB- BB-00 BB-2 2 BB-0 2 2 BB-200 2 2 2 BB-20 2 BB-00 4 BB-0 4 4 BB-400 BB-00 6 4 6 BB-600 UL Listed: E-209 Type ABB CSA Certified: 84 A combination of Type A and BB Bushings. For insulating cables passing through metal boxes or troughs UL Listed: E-209 CSA Certified: 84 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- BBL-00 BBL-2 2 2 BBL-0 2 2 2 BBL-200 2 2 2 BBL-20 2 BBL-00 4 4 BBL-0 4 4 BBL-400 BBL-00 6 4 6 6 BBL-600 8 Dimensions in Inches Trade Type ABB Shd. Ht. Max. Size Catalog Outside Hole Thread Type Type Encl. (inches) Number Dia. Dia. Length BB A Thick ABB-0 ABB- ABB-00 ABB-2 2 ABB-0 2 2 ABB-200 2 2 2 ABB-20 2 ABB-00 4 ABB-0 4 4 ABB-400 ABB-00 6 4 6 ABB-600 Type BBL Existing Enclosure Type ABB 0 N. Frontage Road Skokie, Illinois 600

DA6 Phenolic Insulating Couplings For Threaded Rigid Conduit & IMC O-Z Specification Bushings DA6 Type ICC Will not melt, soften or burn Temperature rating 0 C Dielectric strength of 220 V/mil. An insulating coupling having a substantial center shoulder, which prevents butting of the conduits, to assure a definite break in the metallic path. The Type ICC is recommended for use where high strength or resistance to moisture or acid conditions is required. Material: Canvas base phenolic with tapered (NPT) thread. Dimensions in Inches Trade Size Catalog Max. Overall A (inches) Number Dia. Length Shoulder ICC-0 ICC- 6 ICC-00 ICC-2 2 ICC-0 2 2 2 ICC-200 2 2 2 ICC-20 ICC-00 ICC-0 4 4 ICC-400 /8 ICC-00 6 4 6 ICC-600 4 Type ICC 0 N. Frontage Road Skokie, Illinois 600

DB Insulating Bushings Threaded for Rigid Conduit & IMC Standard Bushings - Standard Locknuts DB Type IB Feature: Temperature rating 0 C Material: Polypropylene UL Listed: E-8 CSA Certified: AP20 UL Standard: 4B CSA Standard: C22.2 No. 8 Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height IB-0 6 IB- 6 IB-00 9 6 6 9 6 IB-2 2 9 6 IB-0 2 9 6 2 IB-200 2 2 IB-20 IB-00 4 6 IB-0 4 4 IB-400 IB-00 6 6 6 IB-600 6 Type IB Type PPC To plug bushings, rigid conduit and IMC. Suitable for use on the following bushings: Type A, B, IBC, BB, IB, BLG, HB, HBLG and 2-series. Material: Polyethylene UL Listing not applicable Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height PPC-0 9 6 PPC- 6 PPC-00 6 PPC-2 PPC-0 2 2 PPC-200 2 2 PPC-20 2 PPC-00 PPC-0 4 4 PPC-400 4 Type PPC 0 N. Frontage Road Skokie, Illinois 600

DB2 Insulated Bushings For Rigid Conduit & IMC Standard Bushings - Standard Locknuts DB2 Type IBC Threaded (NPS) Type IBC-S Threadless Set-Screw UL temperature rating 0 C Insulating liner material is UL V-O Rated (self extinguishing) Plastic insulator is tough. It won t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation. Material/Finish Malleable Iron Body/Zinc Plated Thermoplastic Insulator Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Max. Height IBC-0 6 IBC- 6 IBC-00 IBC-2 2 IBC-0 2 6 2 IBC-200 2 6 Dimensions in Inches Trade Max. Turning Size Catalog Dia. Max. Radius (inches) Number without lug Ht. with lug 9 6 6 2 IBC-20 IBC-00 4 6 IBC-0 4 6 4 IBC-400 6 6 IBC-00 6 6 6 6 IBC-600 6 Type IBC UL Listed: E-8 IBC-0S 6 IBC-S 6 IBC-00S 9 6 CSA Certified: LR 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- IBC-2S 2 IBC-0S 2 6 2 IBC-200S 2 6 6 2 IBC-20S IBC-00S 4 6 2 6 IBC-0S 4 6 2 4 IBC-400S 6 6 2 Type IBC-S 0 N. Frontage Road Skokie, Illinois 600

DB Standard Bushings - Standard Locknuts DB Grounding Insulated Bushings with Aluminum Lug For Rigid Conduit & IMC Type IBC-L-AC Threaded with Aluminum Lay-In Lug Type IBC-LS-AC Set-Screw with Aluminum Lay-In Lug UL temperature rating 0 C Insulating liner material is UL V-O Rated (self extinguishing) The plastic liner is tough. It won t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation. Set-Screw provided with each fitting locks bushing in any desired position. UL Listed for use with copper or aluminum grounding conductors Lugs not sold separately. Material: Body - Malleable Iron Lug - Aluminum Clamping Screw - Steel Set Screws - Steel Finish: Body - Zinc Plated Lug - Tin Plated Clamping Screw - Zinc Plated Set Screws - Zinc Plated UL Listed: E-24264 CSA Certified: LR 99 UL Standard: 46 CSA Standard: C22.2 No. 4 NEMA: FB- Type IBC-L-AC Type IBC-LS-AC Threaded Set Screw Dimensions in Inches Type Type Max. Turning Trade Size Catalog Catalog Grounding Wire Size Dia. Max. Radius (inches) Number Number Min. Max. without lugs Ht. with lugs IBC-0L-4AC IBC-0LS-4AC 4 4 6 IBC-L-4AC IBC-LS-4AC 4 4 6 IBC-00L-4AC IBC-00LS-4AC 4 4 IBC-2L-4AC IBC-2LS-4AC 4 4 2 IBC-2L-20AC IBC-2LS-20AC 4 2/0 2 IBC-0L-4AC IBC-0LS-4AC 4 4 2 6 IBC-0L-20AC IBC-0LS-20AC 4 2/0 2 6 2 IBC-200L-4AC IBC-200LS-4AC 4 4 2 6 2 IBC-200L-20AC IBC-200LS-20AC 4 2/0 2 6 2 IBC-20L-4AC IBC-20LS-4AC 4 4 2 IBC-20L-20AC IBC-20LS-20AC 4 2/0 2 IBC-20L-2AC IBC-20LS-2AC 6 20 6 6 6 9 6 6 6 6 6 2 2 2 2 2 6 IBC-00L-4AC IBC-00LS-4AC 4 4 4 6 6 2 IBC-00L-20AC IBC-00LS-20AC 4 2/0 4 6 6 2 6 IBC-00L-2AC IBC-00LS-2AC 6 20 4 6 6 6 IBC-0L-4AC IBC-0LS-4AC 4 4 4 2 IBC-0L-20AC IBC-0LS-20AC 4 2/0 4 6 IBC-0L-2AC IBC-0LS-2AC 6 20 4 4 IBC-400L-4AC IBC-400LS-4AC 4 4 6 6 4 IBC-400L-20AC IBC-400LS-20AC 4 2/0 6 6 4 IBC-400L-2AC IBC-400LS-2AC 6 20 6 6 6 IBC-00L-4AC 4 4 6 6 IBC-00L-20AC 4 2/0 6 6 IBC-00L-2AC 6 20 6 6 4 6 6 IBC-600L-4AC 4 4 6 4 6 IBC-600L-20AC 4 2/0 6 4 6 6 IBC-600L-2AC 6 20 6 4 0 N. Frontage Road Skokie, Illinois 600

DB4 Standard Bushings - Standard Locknuts DB4 Grounding Insulated Bushings with Bronze Lug For Rigid Conduit & IMC Type IBC-L-BC Threaded with Bronze Lay-In Lug Threaded (NPS) Type IBC-LS-BC Set-Screw with Bronze Lay-In Lug Threadless UL temperature rating 0 C Insulating liner material is UL V-O Rated (self extinguishing) The plastic liner is tough. It won t chip, crack, swell or shrink. It resists corrosion, chemicals and temperature extremes. Surface friction is so low that wires can be pulled with virtually no abrasion on the cable insulation. Set-screw provided with each fitting locks bushing in any desired position. UL Listed for use with copper grounding conductors only. Lugs not sold separately. Material: Body - Malleable Iron Lug - Bronze Clamping Screw - Steel Set Screws - Steel Finish: Body - Zinc Plated Lug - Bright Dip Clamping Screw - Zinc Plated Set Screws - Zinc Plated UL Listed: E-24264 CSA Certified: LR 99 UL Standard: 46 CSA Standard: C22.2 No. 4 NEMA: FB- Type IBC-L-BC Type IBC-LS-BC Threaded Set Screw Dimensions in Inches Type Type Max. Turning Trade Size Catalog Catalog Grounding Wire Size Dia. Max. Radius (inches) Number Number Min. Max. without lugs Ht. with lugs IBC-0L-4BC IBC-0LS-4BC 4 4 6 IBC-L-4BC IBC-LS-4BC 4 4 6 IBC-00L-4BC IBC-00LS-4BC 4 4 IBC-2L-4BC IBC-2LS-4BC 4 4 2 IBC-2L-20BC IBC-2LS-20BC 8 2/0 2 IBC-0L-4BC IBC-0LS-4BC 4 4 2 6 IBC-0L-20BC IBC-0LS-20BC 4 2/0 2 6 2 IBC-200L-4BC IBC-200LS-4BC 4 4 2 6 2 IBC-200L-20BC IBC-200LS-20BC 4 2/0 2 6 2 IBC-20L-4BC IBC-20LS-4BC 4 4 2 IBC-20L-20BC IBC-20LS-20BC 4 2/0 2 IBC-20L-2BC IBC-20LS-2BC 6 20 6 6 6 9 6 6 6 6 6 2 2 2 2 2 6 IBC-00L-4BC IBC-00LS-4BC 4 4 4 6 6 2 IBC-00L-20BC IBC-00LS-20BC 4 2/0 4 6 6 2 6 IBC-00L-2BC IBC-00LS-2BC 6 20 4 6 6 6 IBC-0L-4BC IBC-0LS-4BC 4 4 4 2 IBC-0L-20BC IBC-0LS-20BC 4 2/0 4 6 IBC-0L-2BC IBC-0LS-2BC 6 20 4 4 IBC-400L-4BC IBC-400LS-4BC 4 4 6 6 4 IBC-400L-20BC IBC-400LS-20BC 4 2/0 6 6 4 IBC-400L-2BC IBC-400LS-2BC 6 20 6 6 6 IBC-00L-4BC 4 4 6 6 IBC-00L-20BC 4 2/0 6 6 IBC-00L-2BC 6 20 6 6 4 6 6 IBC-600L-4BC 4 4 6 4 6 IBC-600L-20BC 4 2/0 6 4 6 6 IBC-600L-2BC 6 20 6 4 0 N. Frontage Road Skokie, Illinois 600

DB Standard Bushings - Standard Locknuts Malleable Iron Conduit Bushings Threaded (NPS) For Rigid Conduit & IMC DB Type 2 Malleable Iron/Zinc Plated Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Height *2-8 6 6 2-0 Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- 2-2-00 9 6 6 2-2 2 2-0 2 2 2-200 2 2 2-20 6 2-00 6 6 2-0 4 6 6 4 2-400 4 6 6 2-00 6 6 6 2-600 6 *U.L. Listing not applicable Type 2 Type Capped Bushings Bushings are supplied with plastic insert cap. Malleable Iron/Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 Trade Size Catalog Dimensions in Inches (inches) Number Max. Dia. Height -0-6 -00 9 6-2 2-0 2 2-200 2 6 2-20 2-00 6 6-0 6 6 4-400 4 6 6-00 6 6-600 Type CSA Certified: 99 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- 0 N. Frontage Road Skokie, Illinois 600

DB6 Standard Conduit Locknuts Threaded For Rigid Conduit & IMC Standard Bushings - Standard Locknuts DB6 Type Conduit Locknut Material: through 6 - Heavy Stock Steel Dia. Trade Size Catalog Threads Across (inches) Number Per Inch Thickness Flats -8S* 8-0S 4 6 -S 4 6 Finish: Zinc Plated Optional Finish: Mechanically Galvanized Contact your local representative for pricing and availability. UL Listed: E-8 CSA Certified: AP20 & LR99-00S -2S -0S 2-200S 6 6 2 64 6 2 6 2 2-20 8 9 6-00 8 4-0 8 4 6 4-400 8 9 6-00 8 6 6 6-600 8 6 *Hex Style UL Standard: 4B CSA Standard: C22.2 No. 8 ; NEMA: FB- Material: Aluminum UL Listed: E-8 CSA Certified: 99 & 649 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Dia. Trade Size Catalog Threads Across (inches) Number Per Inch Thickness Flats -0A 4 -A 4 6 6-00A -2A -0A 2-200A 6 6 6 9 6 2 9 6 6 2-20A 8 9 6-00A 8 4-0A 8 4 6 4-400A 8 6-00A 8 6 6 6-600A 8 6 Type 0 N. Frontage Road Skokie, Illinois 600

DB Standard Bushings - Standard Locknuts Conduit Locknuts & Fixture Nuts Threaded For Rigid Conduit & IMC DB Type -8LOS Oversize Locknut covers KO Steel/Zinc Plated Dimensions in Inches Trade Threads Dia. Dia. Size Catalog K.O. Per Across Across (inches) Number Size Inch Thkns. Corners Flats -8LOS & 8 6 Type -8LOS Type -8S Fixture Nuts Steel/Zinc Plated Dimensions in Inches Threads Dia. Dia. Trade Size Catalog K.O. Per Across Across (inches) Number Size Inch Thkns Corners Flats -8S -- 2-2S -- 8 9 6 6 Type -8S 0 N. Frontage Road Skokie, Illinois 600

DB8 Standard Bushings - Standard Locknuts DB8 Standard Conduit Locknuts & Sealing Locknuts Threaded For Rigid Conduit & IMC Type 0 Bonding Wedge Locknut Use with bushings to bond through 6 rigid conduit and IMC to boxes, cabinets or other enclosures where locknut is exposed. Malleable Iron/Zinc Plated UL Listed: E-24264 CSA Certified: 99 UL Standard: 46 CSA Standard: C22.2 No. 4 NEMA: FB- Trade Size Catalog Max. (inches) Number Dia. Thkns Radius 0 6 02 0 6 04 2 6 0 2 2 06 2 2 0 08 4 09 4 6 6 6 6 6 6 6 6 2 6 2 4 0 6 6 2 2* 6 6 * 8 6 4 6 *Not CSA Certified Type 0 Type SLG Sealing Locknut Trade Size Catalog Threads Max. (inches) Number Per Inch Diameter Thickness Supplied with integrally fused gasket Provides raintight or oil tight seal SLG-0S 4 SLG-S 4 SLG-00S SLG-2S 2 6 6 6 6 Steel/Zinc-Plated UL Listed: E-8 SLG-0S 2 2 SLG-200S 2 2 SLG-20S 8 6 SLG-00S 8 4 SLG-0S 8 4 4 SLG-400S 8 6 6 Type SLG CSA Certified: AP20 Not certified UL or CSA UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- 0 N. Frontage Road Skokie, Illinois 600

DB9 Reducing Washers Standard Bushings - Standard Locknuts DB9 Type RW Steel/Zinc Pre-Galvanized UL Listed: E8 CSA Certified: AP20 UL Standard: 4B CSA Standard: C22.2 No. 8 NEMA: FB- Note: Two reducing washers are required for each knockout. Trade Size Catalog Dimensions in Inches (inches) Number A B x RW-2S 0.88.44 x RW-S 0.88. x RW-4S.. x RW-S 0.88 2.9 x RW-6S. 2.9 x RW-S. 2.9 x RW-8S 0.88 2.0 x RW-9S. 2.0 x RW-0S. 2.0 x RW-S. 2.0 2x RW-2S 0.88.00 2 x RW-S..00 2 x RW-4S..00 2 x RW-S..00 2 x RW-6S.98.00 2 x RW-S 0.88.0 2 x RW-8S..0 2 x RW-9S..0 2 x RW-20S..0 2 x RW-2S.98.0 2 x 2 RW-22S 2.4.0 x RW-2S. 4. x RW-26S. 4. x RW-2S.98 4. x 2 RW-28S 2.4 4. x 2 RW-29S 2.9 4. x RW-4S.98 4.6 x 2 RW-S 2.4 4.6 x 2 RW-6S 2.9 4.6 x RW-S.9 4.6 4 x 2 RW-4S 2.0. 4 x 2 RW-44S 2.9. 4 x RW-4S.9. 4 x RW-46S 4.. Type RW Not UL Listed or CSA Certified. 0 N. Frontage Road Skokie, Illinois 600

DB0 Notes DB0 0 N. Frontage Road Skokie, Illinois 600