Axial Piston Pump. Series PV Design 42/43 Variable Displacement

Similar documents
Axial Piston Pump Series PV Design 42/43 Variable Displacement

Axial Piston Pump Series PV Design 45 Variable Displacement. Catalogue HY /UK February 2007

Output flow In l/min at 1500 min

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

Proportional Pressure Reducing Valve Series D1FV

Variable displacement axial piston pumps,

Axial Piston Variable Pump A15VSO

P2060 P2075 P2105 P2145 P3105 P3145

Proportional Directional Valve System

Variable Displacement Open Loop Circuit Axial Piston Pumps AR Series

Variable displacement axial piston pumps,

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Direct Operated Proportional DC Valves

Variable displacement axial piston pump type V30D

V Series AXIAL PISTON PUMP ORDER CODE

2.3 MEDIUM HEAVY DUTY SERIES

Mobile Hydraulic Pumps T6G, T67G, T6ZC. Denison Vane Technology, fixed displacement

Axial piston variable pump A11V(L)O series 40

Series 20 Axial Piston Pumps. Technical Information

Series PVP Variable Volume Piston Pumps

Variable Displacement Piston Pumps Series P2/P3. General Information. P3 Series

Pump model PVPP-*-3023 PVPP-*-3033 PVPP-*-4048 PVPP-*-5060 PVPP-* Max flow at 1500 rpm and 7 bar [l/min]

Truck Accessories. Fittings, Adaptor kits and accessories for F1, F2, T1 and VP1 pumps

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

Axial piston variable pump A10V(S)O Series 31

Axial Piston Fixed Motor A2FM

Fixed Displacement Motor AA2FM (A2FM)

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Series 20 Axial Piston Pumps. Technical Information

Variable Displacement Open Loop Circuit Axial Piston Pumps. V Series

Pilot-Operated Proportional DC Valve Series D*1FH

Axial piston variable pump A15VSO, A15VLO series 10 (US-Version)

Directional servo-valve of 4-way design

Axial piston variable pump A11V(L)O Series 40

Variable Plug-in Motor A6VE

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Axial piston variable pump A10VO Series 32

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

Vickers. Vane Pumps. Double Thru-drive Vane Pumps. High speed, high pressure VQT Series for mobile equipment. Released 7/93

Axial piston variable pump A7VO

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Axial Piston Fixed Pump A17FNO Series 10

Variable Displacement Piston Pumps. Performance Information. Features. Specifications. Controls. Schematic Symbol (Basic Pump) Weight and Package Size

Directional servo-valve in 4-way design

AP212HP Cast Iron Gear Pumps

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Axial piston variable pump A10V(S)O Series 31. Americas. RE-A Edition: Replaces:

Axial Piston Variable Motor A6VM

Axial Piston Fixed Motor A10FM / A10FE (US-Version)

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

Fixed Displacement Motor A10FM A10FE

Axial Piston Variable Double Pump A8VO

Hydraulic Pump Series VP1 Variable Displacement

Radial piston motor for compact drives MCR-C

VPPM /110 ED VARIABLE DISPLACEMENT AXIAL-PISTON PUMPS OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

AXIAL PISTON PUMPS SHPV SECTIONAL VIEW

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

V Series AXIAL PISTON PUMP ORDER CODE

Super Charged Piston Pumps Variable Displacement For Open Circuits. PAVC Medium Pressure

Pilot-Operated Directional Control Valves Series D3 - D11

UŽSISAKYKITE internetu telefonu el. paštu

High Torque Low Speed Motors MR - MRE

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

Axial piston variable pump (A)A4VSO

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

Piston Pumps Series P2 / P3 Variable Displacement

Fixed Displacement Motor A2FM

Variable displacement axial piston pumps,

Variable displacement axial piston pumps,

Chapter 5: Flow Valves

Axial Piston Variable Pump (A)A4VSG (US-Version)

Radial piston motor for frame integrated drives MCR-A

Flow sharing control block in mono block / sandwich plate design M6-22

BENT AXIS PISTON MOTORS SERIES HPM FLANGE ISO HPM. pag.3

Radial piston motors for industrial applications MCR-D

Gear Pump Model G4, Series 2X

AP212 Gear Pumps. Standard and Low Noise series. Reference: 200-P EN-03 1/60. Issue:

Axial piston variable pump A10VSO Series 31 for explosive areas ATEX II 3G ck IIB T4

Axial piston fixed motor A2FM series 70. Americas. RE-A Edition:

Axial piston variable motor A6VM series 71

Axial Piston Variable Motor A6VM (US-Version)

External Gear Pumps Series F

Axial piston variable pump A10VSO series 32

Proportional pressure reducing valve, 3-way variant, pilot operated

RE 91808/ AA4VSE Plug-in dual displacement motor. High pressure range. Series 10 Axial piston swashplate design, SAE model

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Hydraulic Motors. Series V12, V14, T12 Variable Displacement

4.2 FIXED DISPLACEMENT DOUBLE PUMP

Radial piston motor for compact drives MCR-C

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Series 20 Axial Piston Motors. Technical Information

AXIAL PISTON MOTORS SHMF

Axial piston variable pump A4VG Series 40

Axial Piston Variable Motor A6VM

SCM M2. Other advantages:

Axial Piston Variable Pump A10VO

RV1P /118 ED VARIABLE DISPLACEMENT VANE PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

Transcription:

xial iston ump Design 42/43 Variable Displacement aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding

Contents Contents age 5-5- Introduction...3 Ordering referred rogram...4 Noise Levels...8 Efficiency and Case Drain Flows...9 Dimensions...11 Mounting kits...17 ump combinations Thru Drive, Shaft Load Limitations...18 Compensators Compensators Dimensions...19 ressure Compensators...23 Load-Sensing Compensators...24 ower Compensators...25 ower Compensators, Diagrams...26 Electronic Module QDXX (digital)...28 General Installation Information...29 ccessories Compensator...3 Catalogue HY3-3243/UK. 7/28 5-5- 2 arker Hannifin Corporation

Introduction Technical Features Low noise level Fast response Service-friendly High self-priming speed Compact design Thru drive for 1% nominal torque With thru drive for single and multiple pumps Swash plate type for open circuit Technical Data V63 V8 V92 V14 V18 V27 Size 3 3 3 4 4 5 Max. Displacement [cm 3 /rev.] 63 8 92 14 18 27 Output flow at 15 min -1 [l/min] 94.5 12 138 21 27 45 Nominal pressure pn [bar] 35 35 35 35 35 35 Max. pressure pmax 1) [bar] 42 42 42 42 42 42 Max. Case drain pressure [bar].5.5.5.5.5.5 Min. Inlet pressure, abs. [bar].8.8.8.8.8.8 Max. Inlet pressure [bar] 16 16 16 16 16 16 Input power at 15 min -1 and 35 bar [kw] 61.5 78 89.5 136 175 263 Max speed 2) [min -1 ] 28 25 23 24 22 18 Moment of inertia [kgm 2 ].18.18.18.3.3.98 Weight [kg] 6 6 6 9 9 172 5 1) Maximum 2% of the working cycle. 2) The maximum speed ratings are shown for an inlet pressure of 1 bar (absolute) and for a fluid viscosity of ν= 3 mm 2 /s General Information remium quality hydraulic mineral fluid are recommended, like HL oils to DIN 51522, part 2, Brugger- value has to be 3 N/mm² minimum for general application and 5 N/mm² for heavily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2, see also Document HY3-3248/UK arker Hydraulic- Fluids. Viscosity The normal operating viscosity should range between 16 and 1 mm 2 /s (cst). Max. start-up viscosity is 8 mm 2 /s (cst). Seals NBR seals are used for operation with hydraulic fluids based on mineral oil. For synthetic fluids, such as phosphoric acid esters, Flourocarbon seal are required. Filtration For maximum pump and system component functionability and life, the system should be protected from contamination by effective filtration. Fluid cleanliness should be in accordance with ISO classification ISO 446:1999. The quality of filter elements should be in accordance with ISO standards. Minimum requirement for filtration rate x (mm); General hydraulic systems for satisfactory operation: Class 2/18/15, according to ISO 446:1999 Hydraulic systems with maximised component life and functionability: Class 18/16/13, according to ISO 446:1999 5-5- 3 arker Hannifin Corporation

Ordering referred rogram V R 1 xial piston pump variable displacement high pressure version Size and displacement Rotation K 1 T 1 N ump Compensator Standard Threads 2nd pump Compensator Design series: (not required for order) Mounting code Thru drive Seals see opposite page Displacement Size 63 63 cm³/rev 3 8 8 cm³/rev 3 92 92 cm³/rev 3 14 14 cm³/rev 4 18 18 cm³/rev 4 27 27 cm³/rev 5 Rotation 1) R Clockwise 1) When looked on shaft Mounting interface Shaft K metr. ISO 4-hole flange Cylindric, key L 319/2 4-hole flange Splined, DIN 548 N Seals NBR 2nd pump option 5) 1 Single pump, no 2nd pump and coupling Thru drive option no adaptor for 2nd pump T Single pump prepared for thru drive ort 2) Threads 3) 1 BS Metric 4 4) BS Metr. M14 2) Drain, gauge and flushing ports 3) ll mounting and connecting threads 4) For V63-V18 only: pressure port 1 1/4 with 4 x M14 instead of 4 x M12 Mounting kits for flexible mounting of multiple pumps, see page 17. 5-5- 4 arker Hannifin Corporation

Ordering referred rogram Standard ressure Compensator Compensator options 1 Without compensator F D S 1-14 bar, spindle + lock nut F H S 4-21 bar, spindle + lock nut F W S 7-35 bar, spindle + lock nut Remote Compensator options F R Remote pressure compensator F F Load-Sensing compensator Variations for Remote Compensator C External pressure pilot 8) 1 NG6/D3 interface top side ilot valve VC1* mounted L C B C ower compensator Displacement Compensator option 63 14 18 27 Nom. power [kw] Nom. torque- 92 at 15 min -1 [Nm] G 11 71 H 15 97 K 18.5 12 M 22 142 S 3 195 T 37 24 U 45 29 W 55 355 Y 75 485 Z 9 585 2 11 715 3 132 85 Function Variation ower compensator ower compensator and load-sensing NG6 interface top side No pressure compensation djustable pressure compensation 5 electro hydraulic control Compensator style F V closed loop displacement control only, no pressure compensation U closed loop proportional displacement control with pressure compensation compensator version R pilot operated pressure control, NG6 interface K version UR, with proportional pilot valve type VCRE..35 mounted M version UK, with pressure sensor for closed loop pressure and power control Note: Compensator differential p is factory pre-set to: remote compensators, power control 15 ± 1 bar load sensing comp. (not power control) 1 ± 1 bar 5-5- 5 arker Hannifin Corporation

Ordering Options on Request V R 1 K 1 T 1 N axial piston pump variable displacement high pressure version size and displacement rotation variation mounting interface threads code thru drive code coupling code seals compensator see next page Displacement Size 63 63 cm³/rev 3 8 8 cm³/rev 3 92 92 cm³/rev 3 14 14 cm³/rev 4 18 18 cm³/rev 4 27 27 cm³/rev 5 N V W Seals NBR FM NBR with TFE shaft seal FM with TFE shaft seal Coupling for thru drive Rotation 1) R Clockwise L Counter clockwise 1) When looked on shaft 1 Single pump, no coupling 2 V14 or V18 mounted 3 V pump mounted 4 Gear pump mounted Option 2, 3 and 4 not available for single pump. Second pump must be specified with full model code. Variation 1 Standard 9 special adjustment 2) 2) requires Kxxxx number Mounting interface Shaft D 4-hole flange Cylindric, key SE E 4-hole flange Splined, SE F 3) ISO 319/1 4-hole flange Cylindric, key G 3) 4-hole flange Splined, SE K metr. ISO 4-hole flange Cylindric, key L 319/2 4-hole flange Splined, DIN 548 3) s F and G only for V14/18 ort 4) Threads 5) 1 BS metric 3 UNF UNC 4 6) BS metr. M14 7 ISO 6149 UNC 8 ISO 6149 metrisch 4) Drain, gauge and flushing ports 5) ll mounting and connecting threads 6) For V63, V8-V18 only: pressure port 1 1/4 with 4 x M14 instead of 4 x M12 Mounting kits for flexible mounting of multiple pumps, see page 17. Thru drive option No adaptor for 2nd pump T Single pump prepared for thru drive with adaptor for 2nd pump as single part 1) SE, Ø 82.55 mm MK-VBGxMN B SE B, Ø 11.6 mm MK-VBGxBMN C 7) SE C, Ø 127 mm MK-VBGxCMN D 7) SE D, Ø 152,4 mm MK-VBGxDMN E 8) SE E, Ø 165,1 mm MK-VBGxEMN G 9) metric, Ø 63 mm MK-VBGxGMN H metric, Ø 8 mm MK-VBGxHMN J metric, Ø 1 mm MK-VBGxJMN K 7) metric, Ø 125 mm MK-VBGxKMN L 7) metric, Ø 16 mm MK-VBGxLMN M 8) metric, Ø 2 mm MK-VBGxMMN See dimensions for details 7) only for V63 and larger 8) only for V27 9) only for V63 - V92 1) x= frame size, see page 17. 5-5- 6 arker Hannifin Corporation

Ordering Options on Request Standard ressure Compensator Compensator options 1 No compensator 1 With cover plate, no control function F D S 1-14 bar, Spindle + lock nut F H S 4-21 bar, Spindle + lock nut F W S 7-35 bar, Spindle + lock nut Remote compensator options F R Remote pressure compensator F S Variation R, for quick unload valve F F Load-Sensing compensator F T Two valve load-sensing compensator Compensator variation C External pressure pilot 14) 1 NG6 interface top side for pilot valves 2 Like 1 but with ext. pilot port 16) ilot valve VC1* mounted K rop.-pilot valve type VCRE..35 mounted L ilot valve with DIN lock mounted Z ccessory mounted 15) L C B C K Horse power compensator Displacement Compensator option 63 14 18 27 Nominal H. [kw] Nom. torque 1 at 15 rpm [Nm] G 11 71 H 15 97 K 18,5 12 M 22 142 S 3 195 T 37 24 U 45 29 W 55 355 Y 75 485 Z 9 585 2 11 715 3 132 85 Function Compensator variation Horse power compensator Horse power compensator and Load Sensing NG 6 interface top side No pressure compensation djustable pressure compensation rop.-pilot valve type VCRE..35 mounted Z ccessories mounted 15) F V U R K M Electrohydraulic compensator Compensator option ilot pressure supply closed loop displacement control only, no pressure compensation Function roportionalhubvolumenregelung Variation pilot operated pressure control, NG6 interface version UR, with proportional pilot valve type VCRE..35 mounted version UK, with pressure sensor for closed loop pressure and power control Z Version R, accessories mounted 15) Note Compensator differential p is to be adjusted: remote compensators, power control 15 ± 1 bar (s FR*, FT*, *L*, *C*, UR, UD, UZ, UG) load sensing comp. (not power control) 1 ± 1 bar (s FF*) 14) Not for two-valve-compensator 15) ccessories not included, please specify on order with full model code. 16) Only s *FR* and *FT* 5 5-5- 7 arker Hannifin Corporation

Noise Levels V63 - V92 V18 Noise level [db()] 7 6 at full flow at deadhead Noise level [db()] 8 7 at full flow at deadhead 52 1 2 3 ressure [bar] 6 1 2 3 ressure [bar] V14 V27 Noise level [db()] 8 7 at full flow Noise level [db()] 8 7 at full flow at deadhead at deadhead 6 1 2 3 ressure [bar] 6 1 2 3 ressure [bar] Typical sound level for single pumps, measured in unechoic chamber according to DIN 45 635, part 1 and 26. Microphone distance 1m; speed: n = 15 rpm. ll data measured with mineral oil viscosity 3 mm²/s (cst) at 5 C. 5-5- 8 arker Hannifin Corporation

Efficiency and Case Drain Flows Efficiency, power consumption V63 Output flow [l/min] 1 8 6 4 2 V8 Output flow [l/min] 12 96 72 48 24 V92 Output flow [l/min] 15 12 9 6 Input power [kw] Input power [kw] Input power [kw] 7 56 42 28 14 1 2 3 ressure [bar] 8 64 48 32 16 1 2 3 ressure [bar] 1 8 6 4 output flow vol. efficiency overall efficiency input power at full flow input power at deadhead output flow, vol. efficiency output flow overall efficiency input power at full flow input power at deadhead vol. efficiency overall efficiency input power at full flow 1 8 6 4 2 1 8 6 4 2 1 8 6 4 Efficiency [%] (overall, volymetric) Efficiency [%] (overall, volymetric) Efficiency [%] (overall, volymetric) Efficiency and case drain flows V63, V8, V92 The efficiency and power graphs are measured at an input speed of n = 15 rpm, a temperature of 5 C and a fluid viscosity of 3 mm 2 /s. Case drain flow and compensator control flow leave via the drain port of the pump. To the values shown are to be added 1 to 1.2 l/min, if at pilot operated compensators (codes FR*, FF*, FT*, power compensator and p-q-control) the control flow of the pressure pilot valve also goes through the pump. lease note: The values shown below are only valid for static operation. Under dynamic conditions and at rapid compensation of the pump the volume displaced by the servo piston also leaves the case drain port. This dynamic control flow can reach up to 8 l/min! Therefore the case drain line is to lead to the reservoir at full size and without restrictions as short and direct as possible. Case drain flows V63-92 Drain flow [l/min] 12 8 4 dead head full flow 1 2 3 ressure [bar] 5 3 2 input power at deadhead 1 2 3 ressure [bar] 2 5-5- 9 arker Hannifin Corporation

Efficiency and Case Drain Flows Efficiency, power consumption V14 Output flow [l/min] 25 2 15 1 5 V18 Output flow [l/min] 3 24 18 12 6 V27 Output flow [l/min] 5 4 3 2 1 Input power [kw] Input power [kw] Input power [kw] 15 12 9 6 3 175 14 15 1 2 3 ressure [bar] 7 35 25 2 15 1 1 2 3 ressure [bar] 5 vol. efficiency vol. efficiency overall efficiency vol. efficiency overall efficiency output flow input power at full flow input power at deadhead output flow input power at full flow input power at deadhead overall efficiency output flow input power at full flow 1 8 6 4 2 1 8 6 4 2 1 8 6 4 2 Efficiency [%] (overall, volymetric) Efficiency [%] (overall, volymetric) Efficiency [%] (overall, volymetric) Efficiency and case drain flows V14, V18, V27 The efficiency and power graphs are measured at an input speed of n = 15 rpm, a temperature of 5 C and a fluid viscosity of 3 mm 2 /s. Case drain flow and compensator control flow leave via the drain port of the pump. To the values shown are to be added 1 to 1.2 l/min, if at pilot operated compensators (codes FR*, FF*, FT*, power compensator and p-q-control) the control flow of the pressure pilot valve also goes through the pump. lease note: The values shown below are only valid for static operation. Under dynamic conditions and at rapid compensation of the pump the volume displaced by the servo piston also leaves the case drain port. This dynamic control flow can reach up to 12 l/min! Therefore the case drain line is to lead to the reservoir at full size and without restrictions as short and direct as possible. Case drain flows V14-18 Drain flow [l/min] 18 12 6 1 2 3 ressure [bar] Case drain flows V27 Drain flow [l/min] 24 16 8 dead head dead head full flow input power at deadhead 1 2 3 ressure [bar] full flow 1 2 3 ressure [bar] 5-5- 1 arker Hannifin Corporation

Dimensions V63-92, metric version mounting hole for horse power compensator pilot or displacement feedback LVDT drain port L2; G3/4 optional M27x2; ISO 6149-1 (thread options 7 and 8) or 1 1/16-12 UNF (thread option 3) 181 135 31 Ø4 k6 196 Ø16h8 31 12 drain port L1, dimensions see L2 2 9 43.5 92 287 max. 38 gage port M; G1/4 optional M12x1.5; ISO 6149-1 (thread options 7 and 8) or 7/16-2 UNF (thread option 3) 9 1 2 view X max. 133 5 121 18 78 86 238 43 -.25 2 thread M12, 28 deep 26 key 12x8x8 DIN 6885 77.8 192 flushing port L3; G1/2 36 252 optional M27x2; ISO 6149-1 (thread options 7 and 8) inlet: or 1 1/16-12 UNF flage acc. ISO 6162 (thread option 3) DN51; N2 5 The pump shown above has mounting option K and thru drive option T (prepared for thru drive) 4xM12, 2 deep optional 1/2-13UNC-2B (thread options 3 and 7) Ø16 h8 66.6 4xM12, 2 deep optional 1/2-13 UNC-2B (thread options 3 and 7) or thread option 4 (M14, 2 deep) 32 outlet: flage acc. ISO 6162 DN32; N4 56 Mounting optional L splined shaft W4x1.5x15x8f DIN 548 Shown is a clockwise rotating pump with standard pressure compensator. Counter clockwise rotating pumps have inlet, outlet and gauge port reversed. 5-5- 11 arker Hannifin Corporation

Dimensions V63-92, SE version Key: 11,11 x 11,11 8 long Shown above is Mounting option D Thread: 1/2-13UNC-2B 28 deep Mounting option E Splined shaft 13T-8/16 D, NSI B92.1 Variation with thru drive drive output: splined shaft W32x1.5x2x8f DIN548 E C G 287 L K Thru drive adaptors are available with the following dimensions Drawing Dimension B C D E F G Remark Thru drive option 82,55 1 - - - 1 M8 SE 2-Bolt B 11,6 12 127 89,8 M12 146 M12 SE B 2/4-Bolt C 127 14 161,6 114,5 M12 181 M16 SE C 2/4-Bolt D 152,4 14 228,5 161,6 M16 - - SE D 4-Bolt G 63 1 85 6,1 M8 1 M8 2/4-Bolt H 8 1 13 72,8 M8 19 M1 2/4-Bolt J 1 12 125 88,4 M1 14 M12 2/4-Bolt K 125 12 16 113,1 M12 18 M16 2/4-Bolt L 16 12 2 141,4 M16 - - 4-Bolt B H D F 5-5- 12 arker Hannifin Corporation

Dimensions V14-18, metric version mounting hole for horse power compensator pilot or LVDT for displacement feedback drain port L2; G1 optional M33x2; ISO 6149-1 (thread options 7 and 8) or 1 5/16-12 UNF 24 (thread option 3) 158 Ø 5 k6 35 35 Ø 16 h8 2 145 drain port L1, dimensions see L2 max. 385 35 2 48 gage port M; G1/4 optional M12x1.5; ISO 6149-1 (thread options 7 and 8) or 7/16-2 UNF (thread option 3) 9 92 9 1 2 view X max. 133 5 147 16 15 283 53.5 -.25 thread M16, 36 deep 2 18 X key 14x9x75 DIN 6885 88.9 5.8 233 pressure port: 295 suction port: 35 inlet: flage acc. ISO 6162 DN64; N16 The pump shown above has mounting option K 64 and thru drive option T (prepared for thru drive) 4xM12, 2 deep optional 1/2-13UNC-2B (thread options 3 and 7) 4xM12, 2 deep 31.8 optional 1/2-13 UNC-2B (thread options 3 and 7) or thread option 4 (M14, 22 deep) 66.6 32 outlet: flage acc. ISO 6162 DN32; N4 78 Ø 16 h8 Mounting optional L splined shaft W5x2x24x9g DIN 548 4 flushing port L3; G3/4 optional M27x2; ISO 6149-1 (thread options 7 and 8) or 1 1/16-12 UNF (thread option 3) Shown is a clockwise rotating pump with standard pressure compensator. Counter clockwise rotating pumps have inlet, outlet and gauge port reversed. 5-5- 13 arker Hannifin Corporation

Dimensions V14-18, SE version Shown above is mounting option D Thread: 5/8-11UNC-2B 25 deep Key: 12.7 x 12.7 75 long Mounting option E Splined shaft 15T-8/16 D, flat root, side fit NSI B92.1 Mounting option F Key: 11.11 x 11.11 55 long Thread: 1/2-13UNC-2B 25 deep Mounting option G Splined shaft 13T-8/16 D, flat root, side fit NSI B92.1 Variation with thru drive drive output: splined shaft W4x1.5x25x8f DIN548 E C G B H 35 D 415 F 97 Thru drive adaptors are available with the following dimensions Drawing Dimension B C D E F G Remark Thru drive option 82,55 1 - - - 16 M1 SE 2-Bolt B 11,6 12 127 89,8 M12 146 M12 SE B 2/4-Bolt C 127 14 161,6 114,5 M12 181 M16 SE C 2/4-Bolt D 152,4 14 228,5 161,6 M16 - - SE D 4-Bolt H 8 1 13 72,8 M8 19 M1 2/4-Bolt J 1 12 125 88,4 M1 14 M12 2/4-Bolt K 125 12 16 113,1 M12 18 M16 2/4-Bolt L 16 12 2 141,4 M16 - - 4-Bolt 5-5- 14 arker Hannifin Corporation

Dimensions V 27, metric version mounting hole for horse power compensator pilot or LVDT for displacement feedback drain port L2; G1 1/4 optional M42x2; ISO 6149-1 (thread options 7 and 8) or 1 5/8-12 UNF (thread option 3) 23 184 45 45 Ø65 k6 Ø2h8 176 drain port L1, dimensions see L2 472.5 max. 51 9 115 gage port M; G1/4 optional M12x1.5; ISO 6149-1 (thread options 7 and 8) or 7/16-2 UNF (thread option 3) 6 25 9 1 265 max. 133 25 view X 128 11 172 69 -.25 thread M2, 42 deep 22 25 5 key 18x11x98 DIN 6885 12.7 Ø88 43 378 36 inlet: flage acc. ISO 6162 DN89; N25 flushing port L3; G3/4 optional M27x2; ISO 6149-1 (thread options 7 and 8) or 1 1/16-12 UNF (thread option 3) The pump shown above has mounting option K and thru drive option T (prepared for thru drive) 5 69.8 4xM16, 32 deep optional 5/8-11 UNC-2B (thread options 3 and 7) Ø2 h8 36.5 79.4 Ø38 4xM16, 32 deep optional 5/8-11 UNC-2B (thread options 3 and 7) outlet: flage acc. ISO 6162 DN38; N4 8 Mounting optional L splined shaft W6x2x28x9g DIN 548 Shown is a clockwise rotating pump with standard pressure compensator. Counter clockwise rotating pumps have inlet, outlet and gauge port reversed. 5-5- 15 arker Hannifin Corporation

Dimensions V27, SE version Key: 12.7 x 12.7 75 long 2.6 Ø5.8 -.5 56.4 ±.13 Ø165.1-.5 224.5 112.25 Shown above is mounting option D 15.9 8 89.5 97.5 Thread: 5/8-11UNC-2B 25 deep 112.25 224.5 Ø165.1-.5 Mounting option E Splined shaft 15T-8/16 D, flat root, side fit NSI B92.1 88 Variation with thru drive drive output: splined shaft W5x2x24x9g DIN548 H E C G 472.5 531.5 97 B D F Thru drive adaptors are available with the following dimensions Drawing Dimension B C D E F G Remark Thru drive option 82,55 8 - - - 16 M1 SE 2-Bolt B 11,6 11 127 89,8 M12 146 M12 SE B 2/4-Bolt C 127 13,5 161,6 114,5 M12 181 M16 SE C 2/4-Bolt D 152,4 13,5 228,5 161,6 M16 229 M2 SE D 2/4-Bolt E 165,1 17 317,5 224,5 M2 - - SE E 4-Bolt H 8 8,5 13 72,8 M8 19 M1 2/4-Bolt J 1 1,5 125 88,4 M1 14 M12 2/4-Bolt K 125 1,5 16 113,1 M12 18 M16 2/4-Bolt L 16 13,5 2 141,4 M16 224 M2 2/4-Bolt M 2 13,5 25 176,8 M2 - - 4-Bolt 5-5- 16 arker Hannifin Corporation

Kits Mounting kits for multiple pumps, for second pump option MK V BG Mounting kit xial piston pump series V Size Second pump Thread Seals ump size 1 ump size 1: V16 - V23 2 ump size 2: V32 - V46 3 ump size 3: V63 - V92 4 ump size 4: V14 - V18 5 ump size 5: V27 Kit contains positions 3, 69, 84, 85 and 87, see drawing below. T Y B C D E G H J K L M Mounting kits for multiple pumps, couplings Second pump, SE repared for thru drive option (plugged) SE, diameter 5.8 mm SE, diameter 82.55 mm SE B, diameter 11.6 mm SE C, diameter 127,mm SE D, diameter 152.4 mm SE E, diameter 165.1 mm Second pump, metric Diameter 63 mm Diameter 8 mm Diameter 1 mm Diameter 125 mm Diameter 16 mm Diameter 2 mm N V M S Seals NBR FM Thread Metric SE 5 MK V BG K Mounting kit xial piston pump series V Size Coupling ump size 1 ump size 1: V16 - V23 2 ump size 2: V32 - V46 3 ump size 3: V63 - V92 4 ump size 4: V14 - V18 5 ump size 5: V27 Kit contains positions 91 (and 92 for keyed shaft). 69 85 87 92 SE, splined keyed shaft (only up to Ø18, metric) metric splined Coupling for metric, splined shaft DIN 548 1 N25 x 1.5 x 15 2 N32 x 1.5 x 2 3 N4 x 1.5 x 25 4 N5 x 2 x 24 5 N6 x 2 x 28 Coupling for SE splined shaft flat root, side fit 11 SE, 9T 16/32 12 SE-, 11T 16/32 13 SE B, 13T 16/32 14 SE B-B, 15T 16/32 15 SE C, 14T 12/24 16 SE C-C, 17T 12/24 17 SE D+E, 13T 8/16 18 SE F, 15T 8/16 Coupling + adaptor for keyed shaft 2 Diameter 12 mm 21 Diameter 16 mm 22 Diameter 18 mm front pump 3 84 91 second pump 5-5- 17 arker Hannifin Corporation

Thru Drive, Shaft Load Limitations Max. transferable torque in [Nm] for different shafts options Shaft code V63-92 V14-18 V27 D 132 2 2 E 1218 268 268 F -- 132 -- G -- 164 -- K 115 19 285 L 14 265 398 Max. torque transmission cap. for rear mounted pump 56 11 165 Important notice The max. allowable torque of the individual shaft must not be exceeded. For 2-pump combinations there is no problem because V series offers 1% thru torque. For 3-pump combinations (and more) the limit torque could be reached or exceeded. Therefore it is necessary to calculate the torque factor and compare it with the allowed torque limit factor in the table. Required: calculated torque factor < torque limit factor To make the necessary calculations easier and more user friendly it is not required to calculate actual torque requirements in Nm and compare them with the shaft limitations. The table on the right shows limit factors that include material specification, safety factors and conversion factors. The total torque factor is represented by the sum of the individual torque factors of all pumps in the complete pump combination. ump Shaft Torque limit factor D 7728 V63-92 E 7245 K 6762 L 8372 D 1184 E 15876 V14-18 F 7875 G 9765 K 1134 L 1575 D 119 V27 E 1597 K 171 L 23625 Total torque factor of the combination = sum of individual torque factors of all pumps The torque factor of each individual pump is calculated by multiplying the max. operating pressure p of the pump (in bar) with the max. displacement Vg of the pump (in cm³/rev). Torque factor of any pump = p x Vg 5-5- 18 arker Hannifin Corporation

Compensators Dimensions Dimensions standard pressure compensator, code...fds,...fhs,...fws 172 46 43,5 41 T pump axis 45 Dimensions remote pressure and load sensing compensator, codes...frc,...ffc 172 43,5 T 45 46 41 5 72 pump axis remote control port p (code...frc) resp. LS port p F (code...ffc) Dimensions horse power control cartridge and displacement sensor 45 73 37,5 pump body (case) 5-5- 19 arker Hannifin Corporation

Compensators Dimensions Dimensions compensator with NG6-interface for pilot valves, codes...fr1,...fr2,...ff1 43,5 172 74.5 41 T 72 45 pump axis remote control port p (code...fr2 only) resp. LS port p F (code...ff1) Compensators with code...fr1 have no remote control port. Dimensions compensator with mounted pressure pilot valve, codes...fr,...ff 43,5 172 82 87 41 53 45 pump axis pilot valve: VC1C**S35; ** for threads and seals option Compensators with codes...frd,...ffd have a proportional pressure pilot valve type VCC**35 mounted; Compensators with codes...frk,...ffk have a proportional pressure pilot valve type VCREC**35 mounted; ** for threads and seals option; Dimensions of pilot valves see following pages. Dimensions for horse power compensator *L* and *C* are identical to FR* and FF*. 5-5- 2 arker Hannifin Corporation

Compensators Dimensions Dimensions two-spool load sensing compensator, code...ft1,...ft2,...ft 43,5 LS port p F 49 pump axis 172 remote pressure control port p (code...ft2 only) pressure pilot valve VC1T**S35 (code...ft only) 65 24 128 82 21,5 14,5 pressure control stage 65 displacement control stage 5 Dimensions two-spool load sensing compensator with proportional pressure pilot valve, code...ftk 43,5 78 49 pump axis LS port p F 172 pilot valve: VCRET**35 for code...ftk, ** for threads and seals option proportional pressure pilot valve 24 129 15 14 82 65 21,5 pressure control stage displacement control stage 5-5- 21 arker Hannifin Corporation

Catalogue HY2-81/UK Compensators Dimensions Dimensions proportional displacement control, code...fv pump axis Dimensions proportional p/q control, codes...ur,...uk,...um 94,5 pilot valve: VCREM**35 for code...uk, UM, ** for threads and seals option 111 91 133 pressure pilot valve (codes...uk,...um only) pump axis pressure sensor (code...um only) pressure control stage 222 17 95 48 71 24 elbow manifold 5-5- 22 displacement control stage arker Hannifin Corporation

ressure Compensators Standard pressure compensator, code F*S The standard pressure compensator adjusts the pump displacement according to the actual need of the system in order to keep the pressure constant. s long as the system pressure at outlet port is lower than the set pressure (set as spring preload of the compensator spring) the working port of the compensator valve is connected to the case drain and the piston area is unloaded. Bias spring and system pressure on the annulus area keep the pump at full displacement. When the system pressure reaches the set pressure the compensator valve spool connects port 1 to and builds up a pressure at the servo piston resulting in a downstroking of the pump. The displacement of the pump is controlled in order to match the flow requirement of the system. Remote pressure compensator, code FRC While at the standard pressure compensator the pressure is set directly at the compensator spring, the setting of the remote pressure compensator can be achieved by any suitable pilot pressure valve connected to pilot port. The pilot flow supply is internal through the valve spool. The pilot flow is 1-1.5 l/min. The pilot valve can be installed remote from the pump in some distance. That allows pressure setting e. g. from the control panel of the machine. The remote pressure compensator typically responds faster and more precisely than the standard pressure compensator and is able to solve instability problems that may occur with a standard pressure compensator in critical applications. The pressure pilot valve can also be electronically controlled (proportional pressure valve) or combined with a directional control valve for low pressure standby operation. 5 Remote pressure compensator, code FR1 Version *FR1 of the remote pressure compensator provides on its top side an interface NG6, DIN 2434 (CETO 3 at R35H, NF D3). This interface allows a direct mounting of a pilot valve (see option *FR and *FRK page 7). Beside manual or electrohydraulic operated valves it is also possible to mount complete multiple pressure circuits directly on the compensator body. arker offers a variety of these compensator accessories ready to install. ll remote pressure compensators have a factory setting of 15 bar differential pressure. With this setting, the controlled pressure at the pump outlet is higher than the pressure controlled by the pilot valve. FR = included FR1 5-5- 23 arker Hannifin Corporation

Load-Sensing Compensators Load-Sensing compensator, code FFC The load-sensing compensator has an external pilot pressure supply. Factory setting for the differential pressure is 1 bar. The input signal to the compensator is the differential pressure at a main stream resistor. load-sensing compensator represents mainly a flow control for the pump output flow, because the compensator keeps the pressure drop at the main stream resistor constant. variable input speed or a varying load(-pressure) has consequently no influence on the output flow of the pump and the speed of the actuator. By adding a pilot orifice (Ø.8 mm) and a pressure pilot valve pressure compensation can be added to the flow control function. See the circuit diagram below, left. Q Load-Sensing compensator code FFC external orifice and pressure pilot valve FF = included FF1 Shown above is load-sensing compensator, code FF1 with an NG6 interface on top of the control valve. That allows direct mounting of a pilot valve for pressure compensation (see option *FF and *FFK page 7). This version includes the pilot orifice. Due to the interaction of flow and pressure compensation this package has not the ideal control characteristic. The deviation is caused by the pilot valves characteristic. If a more accurate pressure compensation is required, the 2-valve load-sensing compensator code FT1 can be used. The circuit diagram of this version is shown left. Here the interaction of the two control functions is avoided by using two separate control valves for flow and pressure compensation. The 2-valve compensator is equipped with an interface NG6 on the compensators top side. M S L T T L L 1 1 F 2-valve Load-Sens. compensator with interface NG6 for accessories code FT1 Q = included p 5-5- 24 arker Hannifin Corporation

ower Compensators Hydraulic-mechanical power compensator The hydraulic-mechanical power compensator consists of a modified remote pressure compensator ( *L*) or of a modified load-sensing compensator ( *C*) and a pilot valve. This pilot valve is integrated into the pump and is adjusted by a cam sleeve. The cam sleeve has a contour that is designed and machined for the individual displacement and the nominal power setting. t a large displacement the opening pressure (given by the cam sleeve diameter) is lower than at small displacements. This makes the pump compensate along a constant power (torque) curve (see diagrams on opposite page). For all nominal powers of standard electrical motors arker offers a dedicated cam sleeve. The exchange of this cam sleeve (e. g.: to change power setting) can easily be done without disassembly of the pump. On top of that an adjustment of the power setting can be done within certain limits by adjusting the preload of the pilot control cartridge spring. That allows an adjustment of a constant power setting for other than the nominal speeds (15 min -1 ) or for other powers. Ordering code for the power option The first digit designates the power setting: G = 11. kw etc. up to 3 = 132. kw The second digit designates the pilot flow source: L internal pilot pressure, remote pressure function. C external pilot pressure, combines power compensation with load-sensing compensation. The third digit designates the possibility to adjust the overriding pressure compensation: comes with a top side NG6/D3 interface on the control valve to mount any suitable pilot valve or arker pump accessories. B has a threaded pilot port p (G1/4) to connect a remote pilot valve with piping. C includes a pilot valve for manual pressure adjustment. Max. setting: 35 bar. 5 *LC *LB Ø,8 Note: If *CB is connected to an external pilot valve and.8 mm orifice, the orifice in port F has to be removed. *CC *CB 5-5- 25 arker Hannifin Corporation

ower Compensators, Diagrams The graphs below show typical power curves, collected during following conditions: Speed : n = 15 rev/min Temperature : t = 5 C Fluid : HL, ISO VG46 Viscosity : ν = 46 mm 2 /s at 4 C Flow rate Q [l/min] Flow rate Q [l/min] 14 12 1 8 6 4 2 21 2 18 16 14 12 1 8 6 4 2 22 kw 18,5 kw 15 kw 11 kw 3 kw 22 kw 18,5 kw 5 1 15 2 25 3 35 ressure p [bar] 37 kw 3 kw 45 kw 55 kw 37 kw 75 kw 55 kw 45kW 9kW V14 V92 V8 V63 Flow rate Q [l/min] Flow rate Q [l/min] 3 27 24 21 18 15 12 9 6 3 425 35 3 25 2 15 1 5 22 kw 3 kw 45 kw 37 kw 55 kw 75 kw 9kW 11 kw V18 5 1 15 2 25 3 35 ressure p [bar] 55 kw 45 kw 37 kw 9kW 75 kw 132 kw 11 kw V27 5 1 15 2 25 3 35 ressure p [bar] 5 1 15 2 25 3 35 ressure p [bar] 5-5- 26 arker Hannifin Corporation

roportional displacement control, code FV The proportional displacement control allows the adjustment of the pumps output flow with an electrical input signal. The actual displacement of the pump is monitored by an LVDT and compared with the commanded displacement in an electronic control module QDXX. The command is given as an electrical input signal ( - 1 V or resp. 4-2 m) from the supervising machine control. The command can also be provided by a potentiometer. The electronic control module offers a stabilized 1 V source to supply the potentiometer. The electronic module compares permanently the input command and the actual displacement by powering the proportional solenoid of the control valve. deviation from the commanded displacement leads to a modulation of the input current to the solenoid. The control valve then changes the control pressure (port ) until the correct displacement is adjusted. Version FV of the proportional control does not provide a pressure compensation. The hydraulic circuit must be protected by a pressure relief valve. roportional displacement control with overriding pressure control, codes UR, UK and UM Compensator version *UR provides electro- hydraulic displacement control and pressure stage mounted on elbow manifold. The elbow manifold provides NG6/D3 interface on top to mount a pressure pilot valve (not included in *UR). U U Q M U Q M S L T T L L L L U s U s 1 1 1 1 Q Q U Q U Q U p = included FV p 5 When using a proportional pressure pilot valve an electro-hydraulic p/q control can be realized. The proportional pressure pilot valve VCRE..35 is included in compensator version *UK. By using the digital module QDXX-Z it is possible to control the displacement proportionally with overriding open loop proportional pressure control. U S L T U p p included UR additionally at UK Compensator version *UM is completed by a pressure transducer arker SC 8181 CE. In combination with control module QDXX-Z a closed loop pressure control of pump outlet pressure is available. The control module also offers an electronic power limiter in addition to closed loop pressure control with this compensator option. Note: Minimum pump pressure (appr. 2 to 3 bar) depends on system and pilot valve used. ump cannot fully downstroke if system pressure is below that level. U Q M p 1 T L L D B1 U s 1 1 D DB2 Q U Q U S L p = included UM 5-5- 27 arker Hannifin Corporation

Electronic Module QDXX (digital) The digital control module code QDXX-Z is designed for rail mounting. Features Digital control circuit arameter setting via RS-232 interface ll settings (ramps, MIN/MX, control parameters) can be stored digitally and recalled from a C to duplicate settings to other modules Ramp time up to 6 seconds Compatible to the relevant european EMC specifications Easy to use C based setup software Covers all displacements from 16 to 27 cm³/rev Covers all functions: displacement control, displacement control with open loop pressure control, displacement control with closed loop pressure control and displacement control with closed loop pressure control and electronic power limitation. Ordering code QD XX Z Digital control module for p/q control For all frame sizes series V Version Option Technical data Mounting style Snap-on mounting for EN522 rail Body material olycarbonate Inflammation class V2...V acc. UL 94 Mounting position any Env. temperature range [ C] -2...+55 rotection class I 2 acc. DIN 4 5 Weight [g] 16 Duty ratio [%] 1 Supply voltage [V] 18...3VDC, ripple <5% eff. Rush in current [] 22 for.2 ms Current consumption [] < 4 for p/q control ; < 2 for Q-control Resolution [%].25 (power.1) Interface RS232C, 96 baud, 3.5 mm cinch EMC EN 5 81-2, EN 5 82-2 Connctors Screw terminals.2...2.5 mm², plug in style Cables [mm²] 1.5 (WG 16) overall braid shield, for supply and solenoid connection.5 mm² (WG 2) overall braid shield, for sensor and command signal connections Max. cable length [m] 5 For programming the module via C, an interface cable is needed, please order part number QDXX-KBEL separately. 5-5- 28 arker Hannifin Corporation

General Installation Information rogramming software The programming of the p/q control module is done in an easy to learn mode. To select the pump model and size and to set the control paramters the program rovplus must be started. This program runs under WINDOWS 95 and higher. The latest version of this software can be downloaded at the following internet address: www.parker.com/euro_pmd The software offers the following features: TERMINL window to set or read out the control parameters of the module. Settings as well as comments entered in the terminal window can be stored also in RTFformat (opens e. g. under WORD or other text editors) MONITOR window allows to display process variables in numerical format. n OSZILLOSKO window displays process variables as curves. The oscilloscope offers a start - stop function. The images can be saved and stored e. g. for import into other programs. Features Display and documentation of parameter sets Save ond reload of optimized parameter sets Offers oscilloscope function for easy performance evaluation and optimization re-optimized parameter sets for all Vplus piston pump Sizes already in E 2 ROM memory Diagrams Typical static characteristic Typical dynamic characteristic 1% 1% Displacement Displacement 5 Input command +1 V T T R Time t Response time (5-3 bar) ump size T [ms] TR [ms] V92 9 9 V18 17 17 V27 25 25 5-5- 29 arker Hannifin Corporation

ccessories Compensator V C 35 For V pump series ccessories for compensators Function Mounting bolts Threads Seals djustment Solenoid Solenoid accessories Nominal pressure 35 bar 1 1E 2 2E 2M Function Max. pressure relief 1 pressure, electrical unloading 2 pressures, electrical selection 2 pressures + stands electrical selection low pressure default 2 pressures + stands electrical selection stand by default M S Threads Metric SE / UNC Mounting bolts N V Seals NBR FM C For single compensators type R or F S Without bolts M For code U*/MT* + DS 45 U For code U* + DS 42 S djustment Spindle with lock nut omit Y T J Solenoid accessories omit C W For function 1 Conduit box with free wires DIN plug socket without plug Solenoid voltage For function 1 11V/5Hz - 12V/6Hz 22V/5Hz - 24V/6Hz 24V DC Compensator accessory only available on pump, not as single items (replacement kit see spare part list VI-VC-UK). Dimensions VC1* VC1E* djustment S DC solenoid 25 C solenoid 19 48 133 VC2* DC solenoid 25 C solenoid 19 48 VC2M*/VC2E* DC solenoid 241 C solenoid 211 48 133 133 High pressure Low pressure High pressure Low pressure 5-5- 3 arker Hannifin Corporation

ccessories Compensator Schematics VC1* Schematics VC1E* 5 Schematics VC2* Schematics VC2M*/VC2E* *2M* 5-5- 31 arker Hannifin Corporation

ccessories Compensator Ordering code proportional pressure control valve V C RE ump series V ccessories for controller rop. pressure valve Mounting bolts Thread option Seal Nominal pressure C Mounting bolts/ ports For single controller type *MR* or *MF* T For double valve contr. type *FT* S Without bolts M For code U*/MT* + DS 45 U For code U* + DS 42 M S Thread option Metric SE / UNC Nominal pressure 35 35 bar 42 42 bar N V Seal NBR FM roportional pressure control valve roportional pressure pilot valves of series VCRE* (RE6...) are powered by external electronic modules (see catalogue HY11-35 for reference). They allow an infinite electronic adjustment of the pumps compensating pressure. Schematic VCRE* Dimensions VCRE* Example for VCRE* mounted 5-5- 32 arker Hannifin Corporation