NATURAL GAS TRANSMISSION

Similar documents
ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

MEMORANDUM April 10, Phillip Fielder, P.E., Permits and Engineering Group Manager

STATEMENT OF BASIS. Cherokee Nitrogen LLC Cherokee, Alabama Colbert County Facility Number

MEMORANDUM December 14, Phillip Fielder, P.E., Permits and Engineering Group Manager. Rick Groshong, Compliance and Enforcement Manager

MEMORANDUM November 5, Phillip Fielder, P.E., Permits and Engineering Group Manager Air Quality Division

ALLEGHENY COUNTY HEALTH DEPARTMENT (ACHD) AIR QUALITY PROGRAM

Texas Oil and Gas Emissions Inventory Improvement Projects

MARAMA 2015 SCIENCE MEETING JULY 29-30, 2015 RICHMOND, VIRGINIA

This rule shall apply to any stationary source which is a major source of regulated air pollutants or of hazardous air pollutants.

MEMORANDUM November 24, Phillip Fielder, P.E., Permits and Engineering Group Manager Air Quality Division

MAJOR SOURCE OPERATING PERMIT THIRD TITLE V RENEWAL DRAFT

General Plan Approval and General Operating Permit BAQ-GPA/GP-5 and Proposed Exemption 38. Citizens Advisory Council Meeting March 19, 2013

PERMIT APPLICATION REVIEW SUMMARY

Combination of two permits into one. Updating plant emissions. Permit Application was designated as TVR (M-1). 01/07/10

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

STATEMENT OF BASIS. University of Arkansas for Medical Sciences (UAMS) 4301 West Markham St. Little Rock, Arkansas 72205

City of Fort Worth s Natural Gas Air Quality Study Follow-up on Report Recommendations. August 16, 2011

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

ENGINEERING CALCULATION SHEET AIR RESOURCES DIVISION

MEMORANDUM March 26, Phillip Fielder, P.E., Permits and Engineering Group Manager

OKLAHOMA DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. MEMORANDUM February 25, 2011

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)

Overview of Revisions to the Proposed GP-5A and GP-5 and Emissions Discussion

STATEMENT OF BASIS. NAICS Description: Motor and Generator Manufacturing NAICS Code:

Air Permitting: Municipal Facilities with Emergency Generators

STATEMENT OF BASIS. NAICS Description: Other Basic Inorganic Chemical Manufacturing NAICS Code:

Presented by: Richard M. Cestone, PE, CHMM Senior Project Engineer Remington & Vernick Engineers For New Jersey Water Environment Association

State of New Jersey. Department of Environmental Protection Division of Air Quality

Regulatory Impacts of Biogas-fired Internal Combustion Engines

MEMORANDUM April 1, Phillip Fielder, P.E., Permits and Engineering Group Manager. Rick Groshong, Compliance and Enforcement Manager

TECHNICAL REVIEW DOCUMENT For OPERATING PERMIT 09OPGA339. Bill Barrett Corporation Bailey Compressor Station Garfield County Source ID

Engineering Analysis

WRAP Oil & Gas: 2002/2005 and 2018 Area Source Controls Evaluation

AIR QUALITY PERMIT. Kennesaw State University - Marietta Campus

Methanol distribution in amine systems and its impact on plant performance Abstract: Methanol in gas treating Methanol impact on downstream units

Bureau of Air Quality Technical Support Document General Permit GP-5 January 31, 2013

6/1/2011. NSPS and MACT Standards for Combustion Sources at Utility Authorities What happens when a permit has both federal and state regulations?

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION. September 28, 2005 PERMIT TO INSTALL

Permit Holder. Permitted Equipment

STATEMENT OF BASIS. NAICS Description: Tire Manufacturing (except Retreading) NAICS Code:

NARRATIVE. Dika Kuoh Steve Allison DATE: August 5, 2015

Emissions Contaminant Totals Report

Engineering Summary New NGC, Inc.

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

RULE 4352 SOLID FUEL FIRED BOILERS, STEAM GENERATORS AND PROCESS HEATERS (Adopted September 14, 1994; Amended October 19, 1995; Amended May 18, 2006)

Air Quality Impacts of Advance Transit s Fixed Route Bus Service

STATEMENT OF BASIS. for the issuance of Air Permit # 860-AOP-R6

PERMIT APPLICATION REVIEW SUMMARY

ADEQ MINOR SOURCE AIR PERMIT

Huntington Power Plant. Notice of Intent. Submitted to the Utah Division of Air Quality And Prepared by

ALLEGHENY COUNTY HEALTH DEPARTMENT AIR QUALITY PROGRAM

AIR QUALITY PERMIT. Permit No S Effective Date May 26, 2015

MICHIGAN DEPARTMENT OF ENVIRONMENTAL QUALITY AIR QUALITY DIVISION MAY 19, 2005 NEW SOURCE REVIEW PERMIT TO INSTALL NO

Regulatory and Permitting Requirements of Stationary Generators In Delaware

~ SWCAA. ~awfxm~ Paul T. Mairose Chief Engineer

Oxidation Technologies for Stationary Rich and Lean Burn Engines

Streamlining Multiple Applicable Requirements

SAN JOAQUIN VALLEY UNIFIED AIR POLLUTION CONTROL DISTRICT. Guideline for Expedited Application Review (GEAR) Oil Field Sump Replacement Tanks

SWCAA. Southwest Clean Air Agency. October 10, Troy Lomax Longview School District h A venue Longview, WA 98632

STATEMENT OF BASIS Boise Cascade Wood Products, LLC Thorsby Engineered Wood Products Thorsby, Chilton County, Alabama Facility/Permit No.

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

Appendix E Worksheets for Major Sources of PM10, NOx and SO2

San Joaquin Valley Unified Air Pollution Control District

State of the Art (SOTA) Manual for Internal Combustion Engines

Air Individual Permit Permit Limits to Avoid NSR

Texas Commission on Environmental Quality Page 1 DRAFT OIL AND GAS SITES PERMIT BY RULE

Well Pad Operations. Pennsylvania s GP-5A for Sources at Unconventional Natural Gas Well Sites

STATEMENT OF BASIS. for the issuance of Draft Air Permit # 617-AOP-R2

MICHIGAN DEPARTMENT OF NATURAL RESOURCES AND ENVIRONMENT AIR QUALITY DIVISION. September 10, PERMIT TO INSTALL No

~ SWCAA TECHNICAL SUPPORT DOCUMENT TRISTAR TRANSLOAD PNW, INC. SWCAA ID: Air Discharge Permit Air Discharge Permit Application CL-3039

Summaries for Gasoline Distribution Facilities and Gasoline Dispensing Facilities 40 CFR 63 subpart BBBBBB and 40 CFR 63 subpart CCCCCC

PERMIT ISSUED TO LOCATED AT. IN THE Saint Clair NUMBER N7303

AIR EMISSION PERMIT NO IS ISSUED TO. St Cloud State University 720 South Fourth Avenue St Cloud, Stearns County, Minnesota 56301

AIR EMISSION PERMIT NO IS ISSUED TO. Northern Natural Gas Company

DJ Basin Crude Oil Flammability Analysis

NARRATIVE. Dika Kuoh Alaa-Eldin A. Afifi DATE: December 14, 2015

Facility Name: Chevron Products Company Doraville Terminal City: Doraville County: DeKalb AIRS #: Application #: 40411

3.1 Air Pollution Control Officer (APCO): as defined in Rule 1020 (Definitions).

Industrial, Commercial and Institutional Boilers at Area Source Facilities (Boiler GACT) Final Reconsidered Rule Requirements Summary

STATEMENT OF BASIS. NAICS Description: Fabricated Pipe and Pipe Fitting Manufacturing NAICS Code:

State of New Jersey. Department of Environmental Protection Air Quality Permitting

(2) An engine subject to this rule or specifically exempt by Subsection (b)(1) of this rule shall not be subject to Rule 68.

WORKSHOP REPORT. No, the RICE NESHAP applies only to stationary engines as defined in 40 CFR

Fuel Oil Conversions. Association of Energy Engineers (AEE) September 20, 2011

BEST AVAILABLE CONTROL TECHNOLOGY DETERMINATION

Full Compliance Evaluation Report Off-Site Report

Facility Name: Georgia-Pacific Consumer Products LP Savannah River Mill City: Rincon County: Effingham AIRS #: Application #: 40890

South District. Reciprocating Internal Combustion Engines EPA S RICE NESHAP and NSPS. Carter B. Endsley, P.E. Air Resource Permitting

ATTACHMENT C.1 EXXONMOBIL INTERIM TRUCKING FOR SYU PHASED RESTART AIR QUALITY ANALYSIS

BACT Determination Information

LOADING OF ORGANIC LIQUID CARGO VESSELS. (Adopted 10/13/1992, revised 1/18/2001)

RICE NESHAP ZZZZ (>500 hp Non-Emergency CI Engines) Altorfer Meeting June 15, 2010

The following emission units and control devices associated with the friction materials process are currently permitted:

RICE NESHAP Frequently Asked Questions (FAQ)

Impact of Transportation Emissions on New Jersey s Air Quality

DRAFT AUTHORITY TO CONSTRUCT

RULE 4702 INTERNAL COMBUSTION ENGINES PHASE 2 (Adopted August 21, 2003; Amended June 16, 2005; Amended April 20, 2006; Amended January 18, 2007)

TECHNICAL SUPPORT DOCUMENT TRISTAR TRANSLOAD PNW, INC. SWCAA ID: Air Discharge Permit Air Discharge Permit Application CL-3004

Transcription:

NATURAL GAS TRANSMISSION and PROCESSING APPLICATIONS GUIDANCE This guidance is intended to help applicants prepare applications and certifications with a reduced amount of effort, yielding clearer and more accurate applications. We hope to steer new applicants around some common mistakes, allowing them to prepare applications which are complete on their first try. The process involves preparation of facility descriptions, emissions estimates, and completion of some administrative forms. Two passes through the process may be required, calculating emissions based on worst-case assumptions, then adjusting those worst-case conditions and emissions if any level of significance is exceeded. The pollutants of concern are nitrogen oxides (NOx), carbon monoxide (CO), and volatile organic compounds (VOC). Emissions of particulate matter (PM), and sulfur dioxide (SO 2 ) are normally negligible. These are referred to as criteria pollutants. In addition, there may be emissions of hazardous air pollutants (HAPs), primarily benzene, toluene, ethyl benzene, xylene, n-hexane, and formaldehyde. Potential emissions do not take into account any limit on operations or any air pollution control devices present. However, actual emissions do take into account the limit on operations and control devices. If a facility has the potential to emit over 100 tons per year (TPY) but actual emission are less than 100 TPY, then the facility is a synthetic minor source. If a facility has actual emissions of any one criteria pollutant in excess of 100 TPY, its permit should follow major source Title V application procedures. Any facility with a general permit for oil and gas facilities is considered a synthetic minor source. Administrative Forms The first thing to do is acquire a copy of the forms. A. Log onto the DEQ web page: www.deq.state.ok.us B. Go to the Air Quality page C. On the left side of the screen select Forms D. Selecting Permitting Forms E. Scroll down to Oil and Gas Industry and select either Natural Gas Compressor Station Application or Oil & Gas Facilities - Minor Source General Permit Application. If you download the MS Word file, it may be completed on the computer and stored for later use. Natural Gas Transmission 1 Revised 12/29/11

Both the natural gas compressor station (NGCS) application and the Oil and Gas facilities (OGF) application include forms for engines, tanks, and other equipment typically found at oil and gas facilities. Information and emission estimates for additional units may be attached to the application. Example formats are provided in this document. Different formats may be used as long as calculations and emission rates are easily discernable. Please note that the emission rate of the highest pollutant defines the facility. If a facility has actual emissions of 75 TPY NOx, 60 TPY CO, and 40 TPY VOC, it is considered a 75 TPY facility. A true minor source facility will have potential and actual emissions below 100 TPY. On the General Facility Information Form 100-884 for NGCS, please do not mark both construction and operating permit as this makes your application self-contradictory. Construction permits and operating permits are applied for separately. The same thing applies to forms 100-305-B, Notice of Intent to Construct; and 100-305-C-1, Notice of Intent to Operate. Please do not complete a Notice of Intent to Operate until DEQ has received the Notice of Intent to Construct and the facility has been constructed. Additionally, the SIC Code means Standard Industrial Classification Code. These are 4922 for gas transmission and 1311 for gas liquids production. The Landowner Notification Affidavit must be completed and signed for all applications (except for applicability determinations), but it is commonly overlooked, resulting in delays in processing applications and issuing permits. All minor source applications are listed as Tier I. Preparing Emissions Estimates 1. The engine manufacturer should provide emissions rating for each model of engine. There is a great amount of confusion regarding potential emissions. It is common for engine manufacturers to list emissions under multiple conditions. For example, an engine model may be shown as having worst-case NOx emissions of 18 grams per horsepowerhour (g/hp-hr) but emissions at crossover point of 10 g/hp-hr. For a hypothetical 800 HP engine, emissions would be, at worst-case: 800 HP * 18 g/hp-hr / 454 g/lb = 31.72 lb/hr 800 HP * 18 g/hp-hr * 24 hours/day * 365 days/year / 454 g/lb / 2,000 lb/ton = 138.93 TPY This exceeds the major source threshold of 100 TPY, therefore a permit is required, either major or minor. A minor source permit may be obtained for crossover point operations: 800 HP * 10 g/hp-hr * 24 hrs/day * 365 days/year / 454 g/lb / 2,000 lb/ton = 77.18 TPY Natural Gas Transmission 2 Revised 12/29/11

It will also be necessary to include estimates of formaldehyde emissions along with NOx, CO, and VOC. If manufacturer data are available, they are usually the most reliable. If not, AP-42 Section 3.2 has factors for various types of engines (rich-burn, lean-burn, 2- stroke, and 4-stroke). 2. Most facilities include condensate storage tanks and dehydration units. EPA software, TANKS4.0, is used for estimating emissions of volatile organic compounds from storage tanks. A. Prepare a directory on your computer hard drive to receive the program, and where it will be installed later, for example, C:\tanks. B. Log onto EPA s Technology Transfer Network, www.epa.gov/ttn. C. Select CHIEF (Clearinghouse for Inventories and Emissions Factors). D. Select Software and Tools. E. Select TANKS. F. TANKS4.0 can be downloaded. G. Install the program following instructions as provided by the program. Condensate flash emissions must also be accounted for. A spreadsheet which calculates flash emissions based on the Vazquez-Beggs correlation is available online at http://www.deq.state.ok.us/aqdnew/resources/vbe_aug2008.xls. However, if flash emissions exceed 50 TPY, you must determine tank emissions using a process simulator such as HYSIS or PROSIM. More information on calculating flash emissions can be found online at http://www.deq.state.ok.us/aqdnew/permitting/advicedocuments.htm. For storage tanks containing lube oil (either new or used) or glycols, you generally will not need to prepare emissions estimates for those tanks unless these liquids are stored in tanks larger than 19,813 gallons. You will normally need to prepare estimates of emissions from condensate tanks and methanol tanks. Please note that methanol, or methyl alcohol, will exceed the 1.5 psia vapor pressure threshold when its storage temperature exceeds 75 o F, and this routinely happens during summer, even if the annual average temperature is lower. 3. Many facilities will involve dehydration units using glycol desiccants. GRI GLY- CALC 4.0 is obtained from the Gas Technology Institute, (847)768-0500, 1700 South Mount Prospect Road, Des Plaines, Illinois 60018-1804. The input to GLY-CALC involves a recent natural gas analysis. You should be aware that the higher the concentration of each component is shown, the higher its emissions Natural Gas Transmission 3 Revised 12/29/11

will be calculated. A safety factor may be applied to various components to assure that calculated emissions, and later emissions limitations, are high enough that the facility does not violate those limits. Additionally, if you input the capacity of the pump as the glycol circulation rate, you will not have to monitor that flow rate monthly; please be sure that the application states that the maximum rate of the pump has been used. GLY-CALC allows for entering a condenser for control of organic compounds, including various hazardous air pollutants. 4. A dehydration unit reboiler, or any other small gas-fired heater, will have emissions of combustion products. Emissions factors for these units are obtained from EPA s TTN web site: A. Log onto EPA s Technology Transfer Network, www.epa.gov/ttn B. Select CHIEF (Clearinghouse for Inventories and Emissions Factors) C. Select Emission Factors D. Select AP-42 E. Select Chapter 1 F. Download Section 1.4. AP-42 is periodically updated, so limits based on these factors may become out-of-date. It may be to your advantage to include a safety factor on calculations provided that the resultant emissions do not exceed any level of significance such as a regulatory limit or a major source threshold. 5. Emissions of pollutants from flares may be estimated using factors in AP-42, Section 13.5. Downloading is identical to gas emission factors above, except for the different section. 6. Some facilities will have sweetening (amine) units which remove carbon dioxide (CO 2 ) and hydrogen sulfide (H 2 S) from gas as received or from natural gas liquids. An estimate of SO 2 emissions resulting from flaring H 2 S can be made from the maximum anticipated H 2 S concentration (C H2S, normally expressed as ppm) and facility rated gas processing rate, MMSCFD. MMSCFD * C H2S * 365 days/year *64 lb/lb-mole /385 SCF/lb-mole /1,000,000 = TPY SO 2 Emission factors for other pollutants are in AP-42, Section 13.5. Natural Gas Transmission 4 Revised 12/29/11

7. For a transmission facility, VOC leakage from valves, flanges, etc., is normally negligible. For processing plants, fugitive VOC emissions are based on EPA s 1995 Protocol for Equipment Leak Emission Estimates (EPA-453/R-95-017) and an estimated number of components in C3+ service. This reference may also be obtained from www.epa.gov/ttn; factors are listed following in an example calculation. EXAMPLES: Here are some examples of how emissions from various units can be shown: A. Engines Engine No. Engine Make Capacity HP NOx g/hp-hr CO g/hp-hr VOC g/hp-hr C-1 Smith 123 800 3.0 3.5 1.0 C-2 Jones XYZ 600 2.0 2.0 0.5 Engine NOx CO VOC lb/hr TPY lb/hr TPY lb/hr TPY C-1 5.29 23.15 6.17 27.01 1.76 7.72 C-2 2.64 11.58 2.64 11.58 0.66 2.89 Engine C-1 C-2 Control Catalytic Converter Catalytic Converter Horsepower (max) hp 800 600 Fuel Consumption 8,089 7,877 (BTU/hp-hr) Fuel Usage (SCFH) 6,582 6,380 Stack Diameter (Inches) 9 8 Height above Grade (Feet) 19 15 Exhaust Flow (ACFM) 4,000 3,404 Exhaust Temperature ( o F) 950 969 The stack flows at maximum horsepower output are normally provided by the engine manufacturer, along with fuel consumption. Fuel consumption may be listed as MMBTUH (million BTU per hour), SCFH (standard cubic feet per hour), or BTU/hp-hr (BTU per horsepower hour). If BTU/hp-hr is listed, multiply the value by engine rated horsepower and divide by fuel gas heating value (normally 1,000 BTU/SCF) to obtain SCFH fuel usage. For example, if an 800-HP engine is rated at 7,800 BTU/hp-hr, and fuel gas has a heating value of 1,020 BTU/SCF, fuel consumption will be: 800 HP * 7,800 BTU/hp-hr / 1,020 BTU/SCF = 6,118 SCFH. Natural Gas Transmission 5 Revised 12/29/11

B. Heaters Unit Capacity MMBTUH Pollutant Emission Factor, lb/mmbtu Emissions lb/hr TPY Dehy Reboiler 1.0 NOx 0.100 0.100 0.44 CO 0.084 0.084 0.38 VOC 0.0053 0.005 0.02 C. Tanks Tank No. Contents Capacity, Gallons Vapor Pressure psia Annual Throughput, Gallons VOC Emissions, TPY T-1 Methanol 1,500 1.5 15,000 0.68 T-2 Condensate 12,600 5.8 126,000 11.42 When you are uncertain of the annual throughput, please estimate high (10 or more turnovers per year). D. Dehydration Still Vent Pollutant Controlled Emissions lb/hr TPY n-hexane 0.241 1.055 Benzene 0.189 0.829 Toluene 0.072 0.313 Ethyl Benzene 0.002 0.010 Xylene 0.005 0.022 Total HAP 1.022 4.475 Total VOC 4.54 19.88 GLYCALC includes an option for showing condensers or other air pollution control devices. A trial-and-error procedure is needed to find the discharge temperature at which emissions are adequately controlled. Once that temperature is determined, please include a print-out of results. E. Fugitive VOC Leakage Equipment Number of Emission Factor, lb/hr TPY Items lb/hr/source Gas Valves 124 0.0032 0.401 1.755 Relief Valves 25 0.0063 0.158 0.692 Compressor Seals 18 0.0063 0.114 0.498 Connectors/Flanges 1,024 0.0003 0.287 1.256 Light Liquid Valves 217 0.0055 1.183 5.182 Natural Gas Transmission 6 Revised 12/29/11

Relief Valves 50 0.0164 0.818 3.582 Pump Seals 20 0.0164 0.567 2.484 Connectors/Flanges 1,510 0.0005 0.687 3.010 TOTALS 4.215 18.459 F. Flare Unit Capacity MMBTUH Pollutant Emission Factor, lb/mmbtu Emissions lb/hr TPY F-1 1.0 NOx 0.068 0.068 0.30 CO 0.37 0.370 1.62 VOC 0.14 0.140 0.61 The formats here are not rigid. Different formats may be used, but whatever is used should be clear enough that permit engineers can readily discern emission rates. Additional Resources More information on determining Potential to Emit can be found online in DEQ s Fact Sheets section and at http://www.deq.state.ok.us/factsheets/air/ptefctst.pdf. Natural Gas Transmission 7 Revised 12/29/11