Quick user guide for the DM dispenser

Similar documents
Certus Model 460 Turntable Manual. 25-Jun-2007

Certus Model 450 Turntable Manual. 21- Dec- 2006

SMT Place Manncorp 1610 Republic Road Huntingdon Valley, PA PIK-MANN ( )

Triumph Street Triple VSM Grip Heater Install

These instructions show how to build the Remote Controlled Fart machine Sound Kit.

2010 Prius Maintenance

Operating Guide Model 800 Dispenser

CI 3000 Coil Inserter

TIP SHEET Installation instructions for EVO-NIST1 + LC1

TIP SHEET T2352, T3396. Installation Tips for RS1 + EVO-ALL 1-BUTTON REMOTE STARTER FOR: Acura RDX PUSH-TO-START / AUTOMATIC

Prusa i3 Printer Assembly Guide

Lockpicking Tools: User Guide

Contents. Preparing the motor Winding the rotating secondary Winding the primary... 8

Installation Instructions for the Plug & Play Remote Start Package (EVOCHR4)

Disco 3 Clock Spring / Rotary Coupler replacement

INSTALLATION GUIDE Table of Contents

Motor Tuning Instructions

CLASSIC MOTORCYCLE RESTORATION

DESCRIPTION & OPERATION

TIP SHEET T0937. Installation Tips For RS00/PS00 + ADS-TBSL-PL + SPDT

HP LASERJET

2006 SID SERVICE GUIDE

Connecting the rear fog light on the A4 Jetta, while keeping the 5 Light Mod

Installation Tips for your Remote Start/Keyless Entry (for Honda/Acura Vehicles) [EVO-ALL] v1.02 updated 9/13/2013

Micro Tensile Tester User Manual

The DispensGun and components are manufactured by Nordson EFD in the U.S.A.

FOX Racing Shox Bypass Technical Manual.

TIP SHEET. Installation Tips for your RS IB-MUX / PKUMUX (D) + SPDT T1205 v1.2 4/3/14. 1 P a g e

Simple Eurorack Row. Kit Builder's Guide. 4mspedals.com

Installation Tips - (Crimestopper RS1/RS2) & (Fortin EVO-ALL 5): *regular key & automatic transmission only*

Micro-Injection System

Creation Date Last Mod Date Model Year Drawings Estimated Time. 5/22/2009 6/15/2009 S120/S90/E min.

AMERICAN STOVE APPLICATION ARTICLE: DRAFT (Rev. 3: 2/27/08) Precision Dispensing of Epoxy for Engraved Parts

7500 Greensand Filter Installation & Start Up Guide

M-Tuned reroute kit XX

This is a guide to assist you adjust the valve clearance on a 2l V6 MIVEC engine found in a Mitsubishi FTO GPX

Atomic Absorption Spectroscopy

RZR 900 spring/shock installation

2006 RECON SERVICE GUIDE

Installation Tips Crimestopper/ProStart Remote Start system + PLJX + DLRM + SPDT (for GM vehicles) T0760 v1.1 updated 2/5/14

GM C10 Street Grip

Techcon Systems TS5000 Series Rotary Valve

Operating Guide 900 Series Dispenser

Rigid Base / Turntable Bed. Exploded side view of bottom rotating wood drive wheel, showing optics aligned to stop bracket.

Installation Instructions for the Plug & Play Chrysler/Dodge/Jeep Remote Start Package w/mux T5

Stay-IN-Play with Panic Stop Braking

CHASSIS CONTENTS EXTERIOR PARTS 7-1 FRONT WHEEL 7-2 FRONT BRAKE 7-6 HANDLEBARS 7-13 FRONT FORK 7-15 STEERING 7-23 REAR WHEEL 7-26 REAR BRAKE 7-30

Folding Golding. Precision High Speed Travel Wheel

6. Pre-print checks. 3D Touch

5X Racing Mazda Miata Aluminum Shifter Bushing Installation Instructions

TONER CARTRIDGE REMANUFACTURING INSTRUCTIONS XEROX PHASER 3320 TONER CARTRIDGE

Bag 1. Bag 1. Center Pivot. Center Pivot

Coil Inserter Module

HD 7700 Setup & Operator Manual

INSTALLATION INSTRUCTIONS 464, 424 & 324 POST-MIX VALVES

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

Stirling Engine. What to Learn: A Stirling engine shows us how energy is converted and used to do work for us. Materials

Installation Tips for RS4/RS7 + EVO-ALL (NIS 3.b)

CHASSIS CONTENTS EXTERIOR PARTS 6-1 FRONT WHEEL 6-2 FRONT BRAKE 6-6 HANDLEBARS 6-12 REAR WHEEL 6-30 REAR BRAKE 6-34 REAR SHOCK ABSORBER 6-36

Installation Tips for your Crimestopper/ProStart Remote Start system (add-on for GM vehicles) v1.02 updated 1/16/2013

DYNACO STEREO 120 C7 REPLACEMENT MANUAL

INSTALLATION INSTRUCTIONS

Idle Timer Controller - ITC Freightliner MT45 Contact InterMotive for additional vehicle applications

Build Instructions and User Guide

PREPOINT CHAMFER GRINDER MODEL Section 1. Set up and operation

RockyHydro. System Assembly Info Packet

Speakers and Motors. Three feet of magnet wire to make a coil (you can reuse any of the coils you made in the last lesson if you wish)

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

-Magnet (not completely necessary but can come in handy)

Troubleshooting. This section outlines procedures for troubleshooting problems with the operation of the system:

GENUINE PARTS INSTALLATION INSTRUCTIONS

JMW 10 AND 12 Tonearms

TIP SHEET EVO-CHRT6(d) STAND-ALONE ADD-ON REMOTE STARTER

2007-UP NAVIGATION INTERFACE MODULE (Infiniti/Nissan)

SW20 Coolant System Maintenance.

SERVICING MANUAL FOR SPINALIS CHAIRS Outline of Servicing Procedures

DIY Synth Kit - Manual STUTTER SYNTH

TO ORDER, PLEASE CALL +33 (0) DISPENSERS. Volumetric and pneumatic systems

Installation Instructions: Epson 1400 CFS

Introduction. Congratulations on purchasing the Spirit Lights Upgrade Kit that adds some serious lighting effects to your nuclear accelerator!

Assembly Manual. 1/10th Formula 1 Car

Cross Hare Installation Guide

Vehicle Reaction Timer Instructions

EFIE Wideband O2 (Electronic Fuel Injector Enhancer) Installation & Operating Instructions.

CONTENTS. EMERGENCY PUMP USE Electric Pump...H-3 Manual Pump...H-5

Operation and Installation Manual

ATV Graphics Application Guide

Elixir 5 Service Manual

units edition imperial PSI & lbs/in2 Name

Ferrari 328 Standard Brake System Bleed/Flush (Non-ABS)

Installation Tips for RS4/RS7 + EVO-ALL (NIS 3.c) + 2 diodes

INSTALLATION INSTRUCTIONS

MOTORS. Part 2: The Stepping Motor July 8, 2015 ELEC This lab must be handed in at the end of the lab period

TOYOTA TUNDRA BIG BRAKE KIT Section I - Installation Preparation

INSTALLATION INSTRUCTIONS

CUSTOM CAN Custom Can Pneumatic Filling Machine Instructions for Operation and Maintenance

APEX, Long Beach, CA March

QuickTrick Alignment Tools

Build a Simple Handheld Throttle for the Digitrax Zephyr

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Transcription:

Quick user guide for the DM dispenser READ FIRST! Use the shortest/thickest USB cable possible, if the screen dims too much during operation (to the point where it s hard to read the text) your cable or power supply is inadequate and may cause instability. If you re powering the device with the DC power jack make sure it s 5V DC center positive. Don t trust the label, check with a multimiter to be certain. It can also be powered with a 12-24V supply but only after doing some modifications inside, read the user guide online for the specific details. By default it will only work with 5V supplies. For best results use with low viscosity pastes. Solder pastes that come in small ready to use syringes are the safest bet. If it comes in a jar is likely to be higher viscosity for stencil printing purposes, although adding liquid flux can help to thin it down in most cases. When using the dispenser in the pick up mode, piston lubrication is required. Very simple, just add a couple of drops of general purpose oil inside the syringe and the piston will slide much easier. For solder pastes and thick fluids use the conical tips,pick the largest tip size that will work for your application: first start with the green one and check the size of the deposits, switch to a smaller one if necessary. Be aware that when using smaller tips, you'll probably have to reduce dispensing speed. If you intend to connect the dispenser with another machine like a 3D printer or CNC, double check your wiring and connections. Read and understand the external trigger diagram included here. You can change the torque and current draw of the device but do it at your own risk, to know more go to the full user guide online. The syringes, pistons and tips can be reused many times without seeing degradation in performance, before refilling clean the inside thoroughly with isopropyl alcohol wipes. Do not use sharp objects that can scratch the walls.

User Interface To navigate between the menus use the left "Menu" knob and to change a specific value use the right "Value" knob. These are also buttons, pressing the left knob will push the piston forward or lift the syringe (if it's not locked). The opposite happens by pressing the knob on the right. Main Top left: Count, useful for keeping track of dispensed pads. During this screen turning the Value knob will increase or decrease current count by +-1. Top right: Dispense mode. Bottom left: Speed. Bottom right: Retraction setting. 1 Dispensing speed Range from 1 to 30. For high viscosity fluids typical values are between 2 and 5, medium and low viscosity use 5 to 20. Above 20 is recommended for quick movements of the piston. 2 Retraction This is the distance the piston will retract automatically after dispensing, essential to prevent oozing and dripping. Typical values are between 0.10 and 0.20mm 3 Modes Manual: Press and hold to dispense.

Timer: Press start once and it will dispense for the set amount of time (timer resolution can be changed in 0.01 sec increments, read the online advanced settings page for more info). Dot: Intended for low viscosity fluids to give more control on dispensed volume regardless of speed. Press start once and it will move the piston the set distance. 4 Counter Enables or disables the counter on the main screen, switching on and off also resets the count. 5 Use settings profile Displays the current active profile. A profile is a set of parameters that is saved in the internal memory, since each fluid and tip combination (even pad size) will have different speed and retraction values this is an easy way to change between them. When you change profile its values are immediately loaded. Any changes you make are automatically saved to the current active profile after one dispense cycle. For example changing speed from 4 to 5 will only be saved after you actually dispense with the new value. Show extended menu Hides advanced settings to keep menu navigation simple. Go online to the advanced settings page for more info.

Filling the syringe If your paste comes in a syringe pour it in the center as uniform as possible, try not to smear the sides. Push the piston inside while squeezing the sides of the barrel with the other hand. Trapped air will escape through the small gap between the syringe walls and the piston, you can feel when this is happening. Continue all the way down until the fluid is touching all around the bottom of the piston, this means there s no air trapped inside. With the power switch OFF connect the motor, foot switch (if you have one) and USB cable. Then turn the dispenser ON. Attaching the motor First remove the cap and put the tip you ll be using based on the tip/pad size table. Then thread the barrel in the shaft of the motor as far down as you can.

Line up the fins of the syringe and press down the right knob to lower it into position. Stop as soon as the top of the syringe is touching the base of the adapter and twist it clockwise until it clicks into position. (Syringe touching the top of the motor adapter) (Syringe locked in position, touching the screws of the motor) Now you're ready to dispense, try out the default settings: in Manual mode press and hold the pedal or start button until the desired amount has been dispensed, when you release it the piston will move back slightly to prevent oozing, this is the "Retraction" value. Remember the piston pulls back only to release pressure, the paste itself is not meant to go back in for a noticeable amount (if any). Here s a useful trick: if the paste keeps coming out even after the motor has stopped, quickly tap the start button again. This will advance the piston just a little bit but more importantly it will also pull back the full retraction distance which will release the internal pressure very quickly. With the default speed, dispense several pads adjusting the retraction value until you see no oozing.

If you see that the paste comes out despite having a large retraction value (> 0.25mm) or that it oozes too much long after dispensing, it s very likely that air bubbles have become trapped during the filling procedure, sometimes it s not a big problem but if you see that a lot is being wasted then its best to transfer the paste to the second syringe, try to pour it as uniform as possible this time. Once you start getting good results you can increase the speed, do it in increments of +1 until you get the right balance between speed and consistency, with more practice you ll be able to go quicker. Keep in mind that retraction may need to be increased as well to release the extra pressure from the faster moving piston. That s it! now your dispenser is configured for this specific tip size, and paste combination. If you change any of the two you ll need slightly different settings, I recommend you pick a different profile for each one (menu item 5), that way you can recall them quickly in the future.

Detaching motor and storing paste When you re done with your board(s) you can store the remaining paste for later use, the process is the same as attaching the motor but in reverse: Unlock the syringe by twisting it counterclockwise. Line it up and press the left knob to lift it up. Once it clears the motor adapter you can turn it by hand. For storing, remove the tip and put both caps top and bottom. If you don t want to waste the paste left on the tip, you can also leave it on and cover it to prevent air from reaching the paste. You can use food wrap, scotch tape, a drop of hot glue, silicon, play-doh, a strand of wire, etc basically anything that covers the hole. The tips themselves can also be cleaned: remove the paste with a toothpick and then with a rolled up napkin wipe the inside, a couple of drops of isopropyl alcohol help a lot.

Connecting to an external source The dispenser has an optically isolated input for triggering the dispenser remotely. It also provides power from the USB port, this makes it very flexible since it allows you connect simple switches, other systems with a wide voltage range (3-12V) and even sensors powered directly from the dispenser. Note 1: Always check with a multimeter to see which strands in the cable correspond to which pins in the plug, a mix up can short the USB port and damage your device and/or power supply. Note 2: Shut down the unit when plugging the cable to prevent accidental dispensing. Standard 3.5mm cable with three conductors: Using a simple external switch:

For connecting other devices (3D printers etc) you can also use a 3.5mm cable with 4 conductors to isolate grounds between the two systems: If you don t have a 4 conductor cable you can also use a regular one, with the same connection shown left minus the 4th cable. The only difference is that the dispenser and external device grounds will be shared. If you want to extend the trigger voltage to 24V an external 1k resistor (1/4W rated) has to be added in series like this. Pin 1 provides a 5V output which you can use to power an external sensor, in this case a proximity IR.

Vacuum pick up mode. This mode allows you to pick up SMD components for an easier assembly of your boards. With an empty syringe, the piston can be quickly pulled back to create a small vacuum that lifts the components. Before you start, remember to add a little bit of oil in the syringe you ll be using, then move the piston back and forward until you feel that the movement is smooth. Add just enough to lubricate and create a seal all around the piston, you don t want oil coming out the front when you push it all the way forward. Go to this menu screen: And change to Yes Then go to menu screen #6: As long as you remain in this screen you ll be in pick up mode. Attach the motor to the empty syringe and push the left knob to move the piston to the front, put a stainless tip on the syringe. Press and hold Start (or foot switch) you should be able to lift the component right away. Keep pressing the button for 1 or 2 seconds to create a strong enough vacuum. Sometimes you can even hear the pitch of the motor change when the vacuum has been created properly. Now you can release the button, the piston will stop moving and the part will be held in the tip. Place your component in the pad and press the Start button again just once. The piston will return and release the part, it will stop automatically at the end of the syringe. Repeat for all the components in your board. For a more comfortable grip you can bend the steel needles with a pair of pliers or with the rounded edge of a table, just pay attention to the orientation and be careful not to break them. The rubber suction cup accessory is used for picking up ICs. For more advanced features make sure to visit the full user guide online at: https://dmdispenser.wordpress.com/