Power factor correction Static switching units (Three phase).

Similar documents
R.4. Automatic capacitor banks with static system. Power factor correction and harmonic filtering. Homepage :

CTU 02. Thyristor switching module for fast PF compensation. User manual

DYNACOMP. The top-class reactive power compensator

Zero Cross Over Turn On Thyristor Switch Card for Capacitor Bank

Motor Reverser. Catalog

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

LOW VOLTAGE CAPACITORS AND CAPACITOR BANKS. Capacitors department

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

Design Guide. VLT Soft Start Controller MCD 100

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

Thyristor Power Controllers for Resistive and Inductive loads (Product Code 21.3)

CI-tronic Soft starters for Danfoss commercial compressor applications Type MCI 15C, MCI 25C, MCI 50CM-3 I-O

Dynamic PFC:Thyristor Modules TSM Series

Voltage limiting device HVL

Essential equipment for all your requirements

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Short form catalogue Motor protection and control Manual motor starters

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

Thermal Overload Relays

Voltage limiting device HVL

Automatic capacitor banks

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Dynacomp The Top-Class Dynamic Response Compensator

SOLID-STATE CONTACTORS

Power System Solutions (PSS)

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

3NP1 Fuse Switch Disconnectors up to 630 A

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Switching Power Supply

XMC0 Series. Definite Purpose Contactors

Application Note. Dynamic PFC: Power Quality at the Docks (China State Shipbuilding Corporation)

Capacitor Switching Contactors Type K3...-A, K3...-K

Thyristor Power Regulators

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

The High Power Stack Horizon

Automatic COSYS PFC. Automatic power factor correction system NEW

Temperature Controllers

Switch Disconnectors. SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A. Introduction. 7/106 Siemens LV

Controls SSR2. Description

Hillstone PowerBank HPB54 Series ( 400A 700A )

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

Motor Controllers AC Semiconductor Motor Controller Type RSHP Flexy

KEPCO Will Point You In The Right Direction!

Scheda prodotto Relè Series B

Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

POWER FACTOR CORRECTION OF FAST DYNAMICS INDUSTRIAL LOADS

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Solar Inverter/Charger

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

Data Sheet Manual Motor Starters Ex9SN Series

Medium-voltage fuses 3 kv 40.5 kv, 0.4 A 315 A

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

INSTITUTE OF TESTING AND CERTIFICATION (INDIA) PVT. LTD.

Technical Data Sheets

GB60S 60W Single Output General Purpose Series

Technical Data Sheets

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

Single & Three-Phase Soft Starters

Solid State Relays, 3-phase

Temperature Controllers

THYRISTORS T2-2PH from 45A to 2700A Specifications Universal 2 Phase Thyristor Unit , March 2012

DIN-A-MITE C. SCR Power Controller Delivers Up To 80 Amperes in a Compact Package. TOTAL CUSTOMER SATISFACTION 3 Year Warranty. Features and Benefits

Est DCM Double Conversion Module 400kVA - 800kVA

CI-TI Contactors and motor starters Types CI 61 - CI 98

Dimensions WxHxD [mm] Weight [kg]

vacon nx ac drives brake resistors user manual

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

Filters for Power Lines

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

For Info: Phone: Fax:

Ceramic PTC Thermistor:

Functions provided by measuring relays in railway equipment

Technical Data Sheets

ELG4125: Flexible AC Transmission Systems (FACTS)

XMC0 Series DEFINITE PURPOSE CONTACTORS

POWER kva

Modular contactors and relays

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

MaxPak Plus Analog DC V S Drive

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Power Quality. Static Var Generator (SVG) SVG Wallmount & SVG Cabinet Mount

Power thyristor units. 460 series. Control of single-phase resistive and inductive loads. User Manual

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

Power Quality Solutions STATCOM, 100kVAr to 30MVAr Dynamic reactive power compensation

Power Quality Solutions POWER QUALITY SOLUTIONS: ACTIVE HARMONIC FILTERS

SOLSTART Instruction Manual

Industrial Chargers and

RVS-AX Instruction Manual

user's manual nx frequency converters brake resistors

Pioneer 321 MSR. 2/14 Antwerpsesteenweg Gent - Oostakker T +32 (0) F +32 (0)

Thermal overload relays Type TA Class 10

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Transcription:

Power factor correction Static switching units (Three phase). Automatic capacitor banks with static system. JK JAKI

JK3PSZT-XXXXX Automatic capacitor banks with static system. Introduction Selection table JK3PSZT Static switching units (three-phase) 2 3 4 Dimensions 5~7 www.jaki.com.twjk 1

Automatic capacitor banks with static system Automatic capacitor banks with static system. JK3PSZT-XXXXX The all series capacitor banks with static system have been designed for Power factor correction purposes in networks with fluctuating loads. The variations in power are relatively fast (in milliseconds) so that the switching operations are carried out by thyristors, which are connected to a voltage control board, so that the connection and disconnection of the capacitor is carried out with a zero voltage difference. Transients are prevented between the connection and disconnection of steps, obtaining the immediate response to the load fluctuations. Functions and advantages of capacitor banks with a static system The functions or advantages of this compensation system are as follows: Immediate response to the compensation request. The response time of the Power factor correction can be of a single network frequency cycle, thus achieving an almost instantaneous compensation. The lack of transients in the connection allows us to eliminate gaps, flicker and any other alteration generated by the connection's transient. Limited switching operations Lower wear of capacitors and switching elements, due to the elimination of transients and the total absence of mobile mechanical parts. This is how we can greatly increase the working life of the unit, as compared to conventional electromechanical contactor units. Connection of a static capacitor bank Static capacitor banks are usually connected to the general switchboard or secondary switchboards in the case of large-scale installations. Elimination of start-up transients produced by the capacitor's connection. The connection takes place when the voltage network matches that of the capacitor when it is partially or totally loaded. Regulation mode CONVENTIONAL REGULATION STATIC REGULATION Fig.1 20ms 8s Time(s) 2 JKwww.jaki.com.tw

JK3PSZT-XXXXX Static switching units (three-phase) Description The static switching modules of the JK3PSZT series are the basic building block for the construction of staticcapacitor banks for power factor correction purposes. These capacitor banks use thyristors instead of the classic contactors for the connection of each large group of capacitors and they are ideal in installations where the leakage current suffers quick and large fluctuations (load changes in intervals that can range from split seconds to 8 or 10 seconds). Features Features Standard voltages Frequency Auxiliary voltage Overload capacity Input control signal Protections Fuses Thermostat du / dt 208~240, 380~480, 500~600VAC± 10% 47~63 Hz 220VAC± 15% 1.5 In during 1 min AC control, 220VAC± 15%. Contact control. DC control, 12-24VDC. Bussmann or Hinoda di / dt RC protection at 1000 V/ μs 90 100 A/ μs (L=12 μh, not included, it must be installed in series with the capacitor) Automatic fan Heat sink 55 start, 45 stop Application The static switching units of the JK3PSZT Series have been designed to connect and disconnect capacitors in milliseconds. Ambient conditions Maximum ambient temperature Maximum temperature of the dissipator Construction features Degree of protection 50 80 IP00 They can be used to build capacitors with various steps, or for the individual compensation of a load that must be compensated instantly due to connection / disconnection deficiencies, for example, in welding units, cranes, lifts, etc. Standards IEC6015-2, EN61000-6-4, EN61000-6-2 4 JKwww.jaki.com.tw

Dimensions 142mm 5mm 150mm 220mm 154mm 30mm 142mm 135mm P.1 142mm 5mm 150mm 243mm 154mm 30mm FAN FAN 142mm 135mm P.2 www.jaki.com.twjk 5

Dimensions 141mm 5mm 190mm 305mm 172mm 40mm FAN 141mm 133mm P.3 141mm 240mm 365 mm 200 mm 40mm FAN 135mm P.4 141 mm 46 JKwww.jaki.com.tw

Dimensions 263mm INPUT 6mm 168mm 168mm 400mm 210mm 31mm LOAD 242mm P.5 263mm 306mm INPUT 6mm 200mm 200mm 527mm 244mm 62 mm LOAD 288mm 306mm P.6 www.jaki.com.twjk 7

Functional block Diagram Power input Power supply. Fuse Fuse Fuse Zero point input controller. 55 C fan working circuit and over temperature check. Error signal indicates. Load (capacitor) Fuse open check circuit. On the heat sink temperature sensor. 84 JKwww.jaki.com.tw

Automatic capacitor banks with static system. JAKI Enterprise Co., Ltd. No.11, Lane2 Rencih St., Dali City, Taichung City 41282 Taiwan TEL: +886-4-24915501 FAX: +886-4-24954240 www.jaki.com.tw www.jaki.com.tw JK 9