Rosemount 485 Annubar Flanged Assembly

Similar documents
Rosemount 485 Annubar Pak-Lok Assembly

Rosemount 285 Annubar Pak-Lok Assembly

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 585 Annubar Flanged Flo-Tap Assembly

Quick Start Guide , Rev AB June Rosemount 585 Annubar Flanged Assembly

Annubar Flowmeter Series

Quick Start Guide , Rev FB June Rosemount 485 Annubar Flanged Flo-Tap Assembly

The Annubar Flowmeter Series

Rosemount 405 Compact Primary Element. Quick Start Guide , Rev HA June 2016

The 285 Annubar Primary Element Series

Rosemount 3095FC MultiVariable Mass Flow Transmitter with MODBUS Protocol

Rosemount 3095FT MultiVariable Flow Data Logger

, General Instructions for Handling and Installation of Rosemount 1199 Seal Systems

Rosemount 285 Annubar Primary Element Series

Top Mount Installation for DP Flowmeters in Steam Service

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev MA August Contents

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev LA Catalog Contents

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

Rosemount Manifolds. Rosemount Manifolds. Product Data Sheet , Rev NB January Contents

1495 Orifice Plate 1496 Flange Union 1497 Meter Section Installation & Operation Manual

Rosemount Manifolds. Product Data Sheet October , Rev PB. Factory assembled, leak-tested, and calibrated

Rosemount Manifolds. Product Data Sheet September , Rev PA. Factory assembled, leak-tested, and calibrated

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Rosemount 405 Compact Orifice Series

INSTALLATION, OPERATION and MAINTENANCE MANUAL for FLOTEC SENSOR

Rosemount Manifolds. Product Data Sheet April , Rev PC. Factory assembled, leak-tested, and calibrated

Annubar Flowmeter Series

V500 and V510 VERIS Verabar Installation and Maintenance Manual

Rosemount Orifice Series Differential Pressure Flow

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Rosemount 2051 Pressure Transmitter with HART 4-20 ma and HART 1-5 Vdc Low Power Protocol

Model 3051 Sensor Module Replacement

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

Rosemount Multipoint Thermocouple and RTD Profiling Sensors

ACCUTUBE Madison Avenue Cleveland, Ohio (216) FAX (216) web site:

Rosemount 3095FC MultiVariable Mass Flow Transmitter

Model 8800C Vortex Flowmeter

Rosemount 8700 Series Magnetic Flowmeter Sensors

V150 VERIS Verabar Installation and Maintenance Manual

Rosemount 1195 Integral Orifice Primary Element

Micro Motion. CMF400 Sensor. Installation Instructions. Quick Reference Guide P/N , Rev. D May 2003

IFOA Integral Flow Orifice Assembly

Installation, Operation, and Maintenance Manual

STEEMCO Flowmeter for Steam

Rosemount 3051CFA Annubar Flowmeter

Scope. Applicability. Caution. I & M CV3000 Series. Storage. Installation & Maintenance Instructions for Marwin CV3000 Series Three Piece Ball Valves

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Rosemount 8800 Vortex Installation Effects

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010

Rosemount Integral Orifice Flowmeter Series

Rosemount 1151 Pressure Transmitter

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

DP163, DP163G and DP163Y Pilot Operated Pressure Reducing Valves with Stainless Steel Bodies

Reference Manual Rev AA June Rosemount 3155 Nuclear Pressure Transmitter

PFA LINED BALL VALVES Installation, Operation and Maintenance Manual

Anderson Greenwood Single Active SSV Installation and Maintenance Instructions

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Product Data Sheet , Rev KA April 2010 Rosemount 1495 and Contents

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

Rosemount 3051S Electronic Remote Sensor (ERS) System

Rosemount DP Flowmeters and Primary Elements

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

Globe Valve Type Fig. 1 Type 3241 Globe Valve. Mounting and Operating Instructions EB EN

Quick Start Guide , Rev CB March Rosemount DP Level Transmitters and 1199 Diaphragm Seal Systems

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

T5 Flare Gas Transducer

STEEMCO-MAS Flowmeter for Steam

LOW PRESSURE BALANCED VALVE DIAPHRAGM BALANCED

Start FINAL. Step 8: Process Leak Protection (Optional) Step 9: Power up the Transmitter. Step 10: Check Process Connections

Product Data Sheet , Rev GA Catalog Content

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Rosemount DP Flowmeters and Primary Elements

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

Rosemount 3051S Series of Instrumentation

ORIMAS Mass Flowmeter

Deltatop DP61D, DP62D, DP63D

Venturi Flow Meter Installation and Operation Manual

Mounting and Operating Instructions EB 8097 EN. Type and Type Pneumatic Control Valves

REACTOR DISCHARGE VALVES S & DIGESTER BLOW VALVES SB & 5300SB B FLANGED BALL VALVES

KEYSTONE SERIES GRF RESILIENT SEATED BUTTERFLY VALVES INSTALLATION AND OPERATION MANUAL

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

Manifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters

Type 644 and 645 Differential Pressure Pump Governors

I-232.T3S2 Victaulic Style 232 Restrained, Flexible High-Pressure Coupling

I-234. Victaulic Styles 234/234S Restrained, Flexible Single-Gasket Couplings WARNING IMPORTANT INFORMATION ITEMS PROVIDED WITH SHIPMENT:

UNIVERSAL PUMP HANGER INSTALLATION INSTRUCTIONS

Installation Instructions

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

SmartCone Differential Pressure Flow Meter User Manual

Rosemount 3051 Pressure Transmitter

SDP143 Pilot Operated Pressure Surplussing Valve with Cast Steel Body

The Annubar Flowmeter Series. Rosemount 3051SFA ProBar Flowmeter. Product Data Sheet , Rev EA Catalog

Rosemount Annubar Flowmeter Series

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Toroidal Conductivity Sensor

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

DO NOT INSULATE BELOW THIS LINE. * For sizes 1/2" to 1 1/2" add 2 1/2" to 'C' dimension.

DCV1, DCV2 and DCV3 Disc Check Valves Installation and Maintenance Instructions

Transcription:

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar Rosemount 85 Annubar Flanged Assembly Start Step 1: Location and Orientation Step 2: Drill Holes into Pipe Step 3: Assemble and Check Fit-up Step : Weld Mounting Hardware Step 5: Insert the Annubar Step 6: Mount the Transmitter Product Certifications End www.rosemount.com 00825-0100-809[

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB 2009 Rosemount Inc. All rights reserved. All marks property of owner. Rosemount and the Rosemount logotype are registered trademarks of Rosemount Inc. Rosemount Inc. 8200 Market Boulevard Chanhassen, MN USA 55317 T (US) (800) 999-9307 T (Intnl) (952) 906-8888 F (952) 99-7001 Emerson Process Management Asia Pacific Private Limited 1 Pandan Crescent Singapore 12861 T (65) 6777 8211 F (65) 6777 097/65 6777 073 Emerson Process Management GmbH & Co. OHG Argelsrieder Feld 3 8223 Wessling Germany T 9 (8153) 9390 F9 (8153) 939172 Beijing Rosemount Far East Instrument Co., Limited No. 6 North Street, Hepingli, Dong Cheng District Beijing 100013, China T (86) (10) 628 2233 F (86) (10) 622 8586 IMPORTANT NOTICE This installation guide provides basic guidelines for Rosemount 85 Annubar. It does not provide instructions for configuration, diagnostics, maintenance, service, troubleshooting, Explosion-proof, Flameproof, or Intrinsically Safe (I.S.) installations. Refer to the 85 Annubar reference manual (document number 00809-0100-810) for more instruction. This manual is also available electronically on www.rosemount.com. If the 85 Annubar was ordered assembled to a Rosemount 3051S transmitter, see the following Quick Installation Guide for information on configuration and hazardous locations certifications: Rosemount 3051S Series Pressure Transmitter (document number 00825-0100-801). If the 85 Annubar was ordered assembled to a Rosemount 3095 transmitter, see the following Quick Installation Guide for information on configuration and hazardous locations certifications: Rosemount 3095 (document number 00825-0100-716). WARNING Process leaks may cause harm or result in death. To avoid process leaks, only use gaskets designed to seal with the corresponding flange and o-rings to seal process connections. Flowing medium may cause the 85 Annubar assembly to become hot and could result in burns. CAUTION If pipe/duct wall is less than 0.125-in. (3,2 mm) use extreme caution when installing sensor. Thin walls can deform during welding, installation or from the weight of a cantilevered flowmeter. These installations may require a fabricated outlet, saddle or external flowmeter support. Please consult factory for assistance. 2

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar 85 Annubar Flange Assembly Exploded View Transmitter and housing are shown for clarity purposes only supplied if ordered. Transmitter Coplanar Flange with Drain Vents O-Rings (2) Direct Mount Transmitter Connection with Valves Sensor Flange Studs Gasket Mounting Flange Assembly Nuts 85 Annubar Sensor Opposites Side Support NOTE Use an appropriate pipe sealing compound rated for the service temperature on all threaded connections. 3

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP 1: LOCATION AND ORIENTATION Correct orientation and straight run requirements must be met for accurate and repeatable flow measurements. Refer to Table 1 for minimum pipe diameter distances from upstream disturbances. Table 1. Straight Run Requirements 1 Without Straightening Vanes In Plane A Upstream Dimensions With Straightening Vanes Downstream Dimensions Out of Plane A A C C B 8 10 8 2 11 16 8 3 23 28 8 12 12 8

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar STEP 1 CONTINUED... 5 Without Straightening Vanes In Plane A Upstream Dimensions With Straightening Vanes Downstream Dimensions Out of Plane A A C C B 18 18 8 6 30 30 8 NOTE Consult the factory for instructions regarding use in square or rectangular ducts. In Plane A means the sensor is in the same plane as the elbow. Out of Plane A means the sensor is perpendicular to the plane of the elbow. If proper lengths of straight run are not available, position the mounting such that 80% of the run is upstream and 20% is downstream. Use straightening vanes to reduce the required straight run length. Row 6 in Table 1 applies to gate, globe, plug, and other throttling valves that are partially opened, as well as control valves. Misalignment 85 Annubar installation allows for a maximum misalignment of 3. Figure 1. Misalignment ±3 ±3 ±3 5

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP 1 CONTINUED... Horizontal Orientation For proper venting and draining, the sensor should be located in the upper half of the pipe for air and gas applications. For liquid and steam applications, the sensor should be located in the bottom half of the pipe. The maximum temperature for a direct mounted transmitter is 500 F (260 C). Figure 2. Gas Figure 3. Liquid and Steam 5 Recommended Zone 90 5 Recommended Zone 30 5 5 30 Recommended Zone 30 Figure. Top Mounting for Steam (direct mount up to 00 F (205 C)) Recommended Zone 30 30 Recommended Zone 30 5 5 NOTE: For steam applications with DP readings between 0.75 and 2 inh 2 O in horizontal pipes, it is recommended to install the primary element / flowmeter mounting above the pipe. 6

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar STEP 1 CONTINUED... Vertical Orientation The sensor can be installed in any position around the circumference of the pipe, provided the vents are positioned properly for bleeding or venting. Optimal results for liquid or steam are obtained when flow is up. For steam applications, a 90 spacer will be added to provide water legs to ensure the transmitter stays within temperature limits. The maximum temperature for a direct mounted transmitter is 500 F (260 C). Figure 5. Steam Figure 6. Liquid 360 360 Flow Flow Figure 7. Gas Flow 360 7

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP 2: DRILL HOLES INTO PIPE 1. Determine the sensor size based on the probe width (see Table 2). 2. Depressurize and drain the pipe. 3. Select the location to drill the hole.. Determine the diameter of the hole to be drilled according to the specifications in Table 2. Drill the mounting hole into the pipe with a hole saw or drill. DO NOT TORCH CUT THE HOLE. Table 2. Sensor Size / Hole Diameter Chart Sensor Size Sensor Width Hole Diameter 1 0.590-in. (1.99 mm) 3 /-in. (19 mm) + 1/32-in (0,8 mm) 0.00 2 1.060-in. (26.92 mm) 1 5 + 1 /16-in. (1,6 mm) /16-in. (3 mm) 0.00 3 1.935-in. (9.15 mm) 2 1 + 1 /16-in. (1,6 mm) /2-in. (6 mm) 0.00 Note: Drill the hole 180 from the first hole for opposite- side support models. Drill the appropriate diameter hole through the pipe wall. 5. If opposite-side support model is supplied, a second identically sized hole must be drilled opposite the first hole so that the sensor can pass completely through the pipe. (To determine if you have an opposite-side support model, measure the distance from the tip to the first slot or hole. If the distance is greater than 1-in. (25, mm), it is the opposite-side support model.) To drill the second hole, follow these steps: a. Measure the pipe circumference with a pipe tape, soft wire, or string. (For the most accurate measurement the pipe tape needs to be perpendicular to the axis of flow.) b. Divide the measured circumference by two to determine the location of the second hole. c. Re-wrap the pipe tape, soft wire, or string from the center of the first hole. Then, using the number calculated in the preceding step, mark the center of what will become the second hole. d. Using the diameter determined in step 3, drill the hole into the pipe with a hole saw or drill. DO NOT TORCH CUT THE HOLE. 6. Deburr the drilled holes on the inside of the pipe. 8

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar STEP 3: ASSEMBLE AND CHECK FIT-UP For accurate measurement, use the following steps to ensure that Ports A and B are equal distances from the inside walls of the pipe. 1. Assemble the 85 to the mounting hardware with the gaskets and bolts. 2. Hand tighten the bolts just enough to hold the position of the sensor centered in the mounting hardware. 3. Measure the distance from the high point of the weldolet to the first sensing hole, port B, then subtract 1 /16-in (1,6 mm).. Measure the distance from the end of the transferred length in step to the last sensing hole, port A. 5. Compare the numbers obtained in steps 3 and. Small discrepancies can be compensated for with the fit-up of the mounting hardware. Large discrepancies may cause installation problems or error. Figure 8. Fit-up check for 85 Annubar with Opposite-Side Support Liquid or Steam Gas The same within 1 /8-in. (3 mm) Port A Port B ODF Pipe Outside Diameter ODF Port B Pipe Outside Diameter The same within 1 /8-in. (3 mm) Port A 9

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP : WELD MOUNTING HARDWARE 1. Center the flanged assembly over the mounting hole, gap 1 /16-in. (1,6 mm), and measure the distance from the outer diameter of the pipe to the face of the flange. Compare this to Table 3 and adjust the gap as necessary. Table 3. Flange Sizes and ODF Per Sensor Size Sensor Size Flange Size ODF (in. (mm)) Size ODF (in. (mm) 1 1 1 /2-in. 150# 3.88 (98.5) DN0 PN16 3.09 (78.6) 1 1 1 /2-in. 300#.13 (10.9) DN0 PN0 3.21 (81.6) 1 1 1 /2-in. 600#. (112.7) DN0 PN100 3.88 (98.6) 1 1 1 /2-in. 900#.9 (125.) Not Applicable Not Applicable 1 1 1 /2-in. 1500#.9 (125.) Not Applicable Not Applicable 1 1 1 /2-in. 2500# 6.76 (171.6) Not Applicable Not Applicable 2 2.0-in. 150#.13 (10.8) DN50 PN16 3.0 (86.3) 2 2.0-in. 300#.38 (111.2) DN50 PN0 3.51 (89.3) 2 2.0-in. 600#.76 (120.8) DN50 PN100.30 (109.3) 2 2.0-in. 900# 5.88 (19.2) Not Applicable Not Applicable 2 2.0-in. 1500# 5.88 (19.2) Not Applicable Not Applicable 2 3.0-in. 2500# 9.87 (250.7) Not Applicable Not Applicable 3 3.0-in. 150#.63 (117.5) DN80 PN16 3.8 (97.6) 3 3.0-in. 300# 5.00 (126.9) DN80 PN0.16 (105.6) 3 3.0-in. 600# 5.38 (136.6) DN80 PN100.95 (125.6) 3.0-in. 900# 8.19 (208.0) Not Applicable Not Applicable 3.0-in. 1500# 8.56 (217.5) Not Applicable Not Applicable 3.0-in. 2500# 11.19 (28.2) Not Applicable Not Applicable 2. Place four 1 /-in. (6 mm) tack welds at 90 increments. Check alignment of the mounting both parallel and perpendicular to the axis of flow (see Figure 9). If alignment of the mounting is within tolerances, finish weld per local codes. If alignment is outside of specified tolerance, make adjustments prior to making the finish weld. Figure 9. Alignment ODF Tack Welds 3. If opposite-side support is being used, center the fitting for the opposite side support over the opposite side hole, gap 1 /16-in. (1,6 mm), and place four 1 /-in. (6 mm) tack welds at 90 increments. Insert the sensor into the mounting hardware. Verify that the tip of the sensor is centered in the opposite side fitting and the plug will fit around sensor. Finish weld per local codes. If alignment of the sensor does not allow enough clearance to insert the opposite side plug, make the necessary adjustments prior to making the finish weld.. To avoid serious burns, allow the mounting hardware to cool before continuing. 10

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar STEP 5: INSERT THE ANNUBAR 1. Align the flow arrow on the head with the direction of flow. Assemble the bar to the mounting flange using a gasket, bolts, and nuts. 2. Tighten the nuts in a cross pattern to allow even compression of the gasket. 3. If opposite side support is threaded, apply an appropriate thread sealing compound to the support plug threads and tighten until no leakage occurs.. If opposite side support is a socket weld fitting, insert the plug into the sockolet fitting until the parts contact. Retract the plug 1 /16-in. (1,6 mm) remove the Annubar sensor and apply fillet weld per local codes. STEP 6: MOUNT THE TRANSMITTER Transmitter Mounting, Direct Mount Head with Valves It is not necessary to retract the Annubar when direct mounting a transmitter with valves. 1. Place PTFE O-rings into grooves on the Annubar head. 2. Align the high side of the transmitter to the high side of the sensor ( Hi is stamped on the side of the head) and install. 3. Tighten the nuts in a cross pattern to 00 in lb (5 N m). Transmitter Mounting with Remote Mount Head Temperatures in excess of 250 F (121 C) at the sensor module diaphragms will damage the transmitter. Remote mounted transmitters are connected to the sensor by means of impulse piping, which allows process temperatures to decrease to a point where the transmitter is no longer vulnerable. Different impulse piping arrangements are used depending on the process fluid and must be rated for continuous operation at the pipeline design pressure and temperature. A minimum of 1 /2-in. (12 mm) outer diameter stainless steel tubing with a wall thickness of at least 0.035-in. (0,9 mm) is recommended including and under 600# ANSI (DN50 PN100). Above 600# ANSI (DN50 PN100), stainless steel tubing with 1 /16-in. wall thickness.threaded pipe fittings are not recommended because they create voids where air can become entrapped and create leakage points. 11

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP 6 CONTINUED... The following restrictions and recommendations apply to impulse piping location: 1. Impulse piping that runs horizontally must slope at least one inch per foot (83 mm/m). Slope downward (toward the transmitter) for liquid and steam applications Slope upward (toward the transmitter) for gas applications. 2. Outdoor installations for liquid, saturated gas, or steam may require insulation and heat tracing to prevent freezing. 3. An instrument manifold is recommended for all installations. Manifolds allow an operator to equalize the pressures prior to zeroing and isolates the process fluid from the electronics. Figure 10. Valve Identification for 5-valve and 3-Valve Manifolds 5-Valve Manifold 3-Valve Manifold To PH To PL To PH To PL MV ME MH MEH 2 MEL ML MH 2 ML DVH DVL DVH DVL 1 1 12

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar STEP 6 CONTINUED... Table. Description of Impulse Valves and Components Name Description Purpose Components 1 Transmitter Reads Differential Pressure 2 Manifold Isolates and equalizes electronics Manifold and Impulse Valves PH Primary Sensor (1) High and low side pressure process connections. PL Primary Sensor (2) DVH Drain/Vent Valve (1) Drains (for gas service) or vents (for liquid or steam service) the DP DVL Drain/Vent Valve (2) sensor diaphragms MH Manifold (1) Isolates high side or low side pressure from the process ML Manifold (2) MEH Manifold Equalizer (1) Allows high and low pressure side access to the vent valve, or for MEL Manifold Equalizer (2) isolating the process fluid ME Manifold Equalizer Allows high and low side pressure to equalize MV Manifold Vent Valve Vents process fluid (1) High Pressure (2) Low Pressure Recommended Installations For Remote Mount Transmitters Gas Service Secure the transmitter above the sensor to prevent condensable liquids from collecting in the impulse piping and the DP cell. Figure 11. Horizontal Gas Figure 12. Vertical Gas 13

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB STEP 6 CONTINUED... Steam or Liquid Service (below 600 F (315 C)) Mount the transmitter below the process piping, adjust 10 to 15 degree above direct vertical down. Route the impulse piping down to the transmitter and fill the system with water through the two cross fittings. Figure 13. Horizontal Steam and Liquid Figure 1. Vertical Steam and Liquid NOTE Ensure the drain legs are long enough to capture the dirt particles and sediment. Top Mounting for Steam Service (required for steam temperatures above 600 F (315 C)) This orientation can be used for steam at any temperature. However, it is required for installations above 600 F (315 C). For remote mount installations the impulse piping should slope up slightly from the instrument connections on the Annubar to the cross fittings allowing condensate to drain back into the pipe. From the cross fittings, the impulse piping should be routed downward to the transmitter and the drain legs. The transmitter should be located below the instrument connections of the Annubar. Depending on the environmental conditions, it may be necessary to insulate the mounting hardware. Figure 15. Horizontal Top Mounting for Steam 1

Quick Installation Guide 00825-0100-809, Rev DB Flanged 85 Annubar PRODUCT CERTIFICATIONS Approved Manufacturing Locations Rosemount Inc. Chanhassen, Minnesota USA European Directive Information The EC declaration of conformity for all applicable European directives for this product can be found on the Rosemount website at www.rosemount.com. A hard copy may be obtained by contacting our local sales office. European Pressure Equipment Directive (PED) (97/23/EC) Rosemount 85 Annubar Refer to EC declaration of conformity for conformity assessment Pressure Transmitter See appropriate Pressure Transmitter QIG Hazardous Locations Certifications For information regarding the transmitter product certification, see the appropriate transmitter QIG: Rosemount 3051S (document number 00825-0100-801) Rosemount 3095M (document number 00825-0100-716) 15

Flanged 85 Annubar Quick Installation Guide 00825-0100-809, Rev DB 16