User manual MTS-32. QUI-1013 Version 1.5 January

Similar documents
Operating Instructions. AirChek XR5000. SKC Inc. 863 Valley View Road Eighty Four, PA USA. Form Rev 1505

SBC / 2140 / Stage Battery Charger User Manual

SOLAR LIGHTING CONTROLLER SUNLIGHT MODELS INCLUDED IN THIS MANUAL SL-10 SL-10-24V SL-20 SL-20-24V

8-STAGE AUTOMATIC BATTERY CHARGER MCU CONTROLLED - HIGH FREQUENCY SWITCHMODE MODELS: KACHG1207, KACHG1212, KACHG1220, KACHG2410. Instruction Manual

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

Figure 1. AirChek XR5000 Air Sample Pump

OPERATIONAL MANUAL EMBC-8025 INTELLIGENT BATTERY CHARGER. Version 1.5

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

PANcharge1k Battery Charger User's Manual

General Precautions. Personnel Precautions

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Doc: MGA-µS Version: 1.0 Page 2 of 6

c-go 24V/6A 24V/8A 24V/12A

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

Manual Installation & Operation

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

Timing Chain - Renew ( )

MPI MX-9900 SUPER GLOW On-board Glow Driver

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

OPERATING INSTRUCTIONS

Uninterruptible Power System

Evensprey 300 Machine Assembly

Timing Chain Renew ( ) Renew. Section Title. Special Tools. Proprietary Tools Scraper Engine support bar

USER S MANUAL G SERIES USER S MANUAL. Ref.49-MG000EN08

Emergency lighting units EM series

FREEWAY RANGE OWNERS MANUAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Combined Ventilation Controller RVWS-T-224HA

BATTERY CHARGER RS-1000 Instruction Manual

Galileo with wifi RADIO CONTROLLED QUAD-COPTER

TERMINATOR User Manual

CONTENTS TABLE OF CONTENTS... 1 INTRODUCTION... 2 SEC 1 - SPECIFICATIONS... 3 SEC 2 - DESCRIPTION... 5 SEC 3 - OPERATING INSTRUCTIONS...

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

GXSeries. User Guide DANGER

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

CYCLONE PocketMax PP-1000 Compact Battery Pack for Portable Flashes. User Manual

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

Operating Instructions AirLite Sample Pump Cat. No SKC Inc. 863 Valley View Road Eighty Four, PA 15330

The Safari Portable Flash Generator

E Series Electric Actuators

Battery Charger. Series EASY Charger. User s manual

Uninterruptible Power System

Smart Power is a power socket with built-in automatic for start/stop-function of fans and motor dampers in proces ventilation units.

CBC-9130 / V 30A / 24V 15A Pro. Charger. Operation manual

BRAVO Inverter/Battery Charger. Table of Contents

Instructions for the BASIC BCVA Rotary heat exchanger, Sizes

INSTRUMENTATION & CONTROL

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

I t n e t l e l l i l g i e g n e t n So S l o a l r a Ch C a h r a g r e g Co C n o t n r t o r l o l l e l r U e s r e s Man an al

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Intelligent Solar Charge Controller. User's Manual. Please read this manual carefully before you use this product

RADIO CONTROLLED QUAD-COPTER WITH CAMERA

User Manual GRX- 950 and GRX- 950 Li

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

MODEL 901 OPERATING INSTRUCTIONS

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

Installation, Operation and Maintenance Manual

GV-4 Manual 4A / 50W IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Solar Charge Controller with Maximum Power Point Tracking.

Model JR-2 Current Interrupter. Operating Manual (Revised August 19, 2011)

Product Specification

CALEFFI. Ball shut-off valve fitted for integrated flow rate measuring sensor. 111 series 01234/13 GB. (kpa) (mm w.g.) G (m 3 /h)

OWNERS MANUAL GPS RENTAL. All PowaKaddy electric trolleys have been awarded the Quiet Mark by the Noise Abatement Society

ALLURE BP320 by Norman

LITHIUM IRON PHOSPHATE BATTERY Multi-application - LiFePO4 Power

Galileo RADIO CONTROLLED QUAD-COPTER

Emergency lighting units EM powerled

Instructions for the BCEA Rotary heat exchanger

PFC W HF/PFC Battery Charger

Centrifuge Operator / Service Manual

SKC Leland Legacy Pump for PCBs

TC62D Installation Instructions

QuickBoost Instruction Manual

HT Dielectric Withstand Tester Volts AC Output Volts DC Output COMPLIANCE WESTUSA. Instruction Manual

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

DANGER. What s in the BOX. N02 Introduction. Before Started

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

A U T O M A T I C T R A N S M I S S I O N M U L T I - C H A N N E L T W O - W A Y L C D R E M O T E S T A R T E R AS-2510 TW.

RUTLAND HRDi CHARGE REGULATOR INSTALLATION AND OPERATION

3000W HF/PFC Battery Charger

GENERALITIES TECHNICAL FEATURES

24-hour/Weekly Time Switch H2F

PSM72H Push-Button Start Module

EtronixPulseRXInstructions 6/6/11 09:17 Page 1

SWITCH MODE BATTERY CHARGER

Uninterruptible Power System

Emergency lighting units EM LED Light Engines

Phoenix Inverter

BRAVER UPS. (Uninterruptible Power System) User s Manual

Emergency lighting units EM powerled

TWO-WAY LED AUTOMATIC TRANSMISSION REMOTE STARTER. User Guide WARNING

Lithium Power Supply

INSTALLER MANUAL USER MANUAL. Contents

GENERAL INFORMATION MECHANICAL INSTALLATION PRESSURE INDEPENDENT VALVES 2-1/2"-10" MVP INSTALLATION & OPERATION INSTRUCTIONS UNION CONNECTIONS

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

User Manuel. Titan Hummer XL

ATOTH-G Series BLDC Motor Controller. User s Manual

GLM SERIES CONTROL Users Manual Rev:

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Transcription:

Version 1.5 January 2015 User manual MTS-32

Page 2 Contents 1. Introduction... 3 2. Principles of operation... 3 2.1 Principles of MTS-32 ventilation... 3 2.2 Principles of sorbent tube sample collection using the MTS- 32 4 3. Connecting the MTS-32 to a power supply... 6 3.1 General battery requirements... 6 3.2 Selecting the power option... 6 3.2.1 Connecting the MTS-32 to a 120 V/230 V electricity supply... 6 3.2.2 Powering the MTS-32 using the integrated 12 V battery option... 7 3.2.3 Connecting the MTS-32 to an external 12 V battery... 7 3.3 Powering the optional internal heaters... 7 4. Connecting the sampling pump... 8 4.1 Connecting the ACTI-VOC... 8 4.2 Connecting the FLEC pump... 9 5. Setting the timer... 9 6. Sample tube insertion... 10 7. Operation... 10 7.1 Turning on the power... 10 7.2 Summary of operation... 10 7.3 Turning on the pump to begin the sampling sequence... 11 7.3.1 Turning on the ACTI-VOC... 11 7.3.2 Turning on the FLEC... 11 7.4 Finishing sampling sequence... 12 8. Battery charging... 12 8.1 Charger circuit for alternative constant-flow sample pumps... 12 9. User maintenance... 13 10. Specifications... 14 10.1 MTS-32... 14 10.2 Accessories... 14 10.2.1 Sealed Lead-Acid Battery (12V)... 14 10.2.2 Charger for Lead Acid Battery (12V)... 15 10.2.3 Power Supply (12V)... 15

Page 3 1. Introduction There are many monitoring situations where it is necessary to obtain site data over periods of 24 hours or even longer. Continuous on-site monitoring requires a complete analytical system at each monitoring location. However, using an automated collection system based on thermal desorption tubes allows samples to be collected sequentially onto a series of sorbent tubes with no dead or lost time. Each tube can be used to sample the air for periods of minutes to hours. The MTS-32 allows sequential sampling onto a series of up to 32 industry-standard sized sorbent tubes. It is a self-contained unit powered either using an integrated rechargeable 12 V battery or normal 120 V/230 V supply using an appropriate 12 V adaptor. Caution: Although the MTS-32 is contained within a shower-proof box, it should be protected from extreme weather conditions if outdoor sampling is to be carried out. The unit should preferably be located above ground level. 2. Principles of operation 2.1 Principles of MTS-32 ventilation The sampling system is housed in a tough low-emitting polymer box with a polycarbonate sealed lid. Air is drawn over the sampling end of the sorbent tubes by means of a fan and air intake duct. The air inlet and outlet ports are fitted with a fine wire gauze to keep out insects. The same housing incorporates the 12 V supply socket for use, if the MTS-32 is to be battery-powered. The fan is a 12 V, low-speed long-life unit using minimal current from the battery. At 12 V the fan throughput is about 1 L per second, which is enough to change the air over the sampling ends of the sorbent tubes more than 10 times per minute. The general arrangement is shown in Figure 1.

Page 4 Figure 1: Cross-section of MTS-32, indicating air flow. 2.2 Principles of sorbent tube sample collection using the MTS-32 Figure 2 shows a section through the manifold block, which holds up to 32 tubes. The rotating pump connector plate is driven round the base of the manifold block in a clockwise direction until it is positioned in line with the tube to be sampled. Air is then drawn through that tube for the selected time period, before the rotating pump connector plate moves on to the next tube position. The diffusive limiters on the sampling end of each of the tubes tube play a critical role both before and after the sample collection period.

Page 5 Figure 2: Sample flow schematic. Any sorbent tubes not being pumped could potentially take up analytes by diffusion, or lose retained analytes by outgassing. To prevent this, sorbent tubes are protected using either DiffLok caps (Figure 3) or SafeLok tubes with integrated diffusion-locking inserts at each end (Figure 4). Diffusion-locking inserts are also fitted into every tube connector position in the tube manifold block (Figure 2). Diffusionlocking technology prevents both diffusive ingress of contaminants and loss of retained sample in every tube that is idle in the manifold block, both before and after sampling. Figure 3: Illustration of a DiffLok cap, showing the diffusion-locking insert.

Page 6 Figure 4: Schematic of a SafeLok tube, illustrating the diffusion-locking inserts. 3. Connecting the MTS-32 to a power supply The MTS-32 can be powered either by an integrated 12 V battery (e.g. MTS-5009) or by 120 V/230 V electricity using a 12 V adaptor (MTS-5011). This power drives both the sampling pump and the rotating pump connector plate. 3.1 General battery requirements The MTS-32 can be run from any 12 V lead acid battery of sufficient capacity. The mean current for operating the unit is less than 0.1 A, with a similar current required to drive the pump charger. With a total load of 0.2 A, the 10 A h battery available from Markes International will drive the unit (both MTS-32 and ACTI-VOC pump) for 40 hours or more. This battery is fitted with standard, lowvoltage connectors, which ensure connection with the correct polarity. Since the battery is sealed, it MUST be charged from a high-quality constant-voltage charger. A suitable charger is available from Markes International (MTS-5010). Because this charger is, in effect, a voltage-controlled power unit, it can also be used directly to drive the MTS 32 from mains electricity for indoor or test purposes. The charger is NOT suitable for outside use. If desired, a higher capacity 12 V car battery can be used, for which a simple connecting lead is available (MTS-5013). This would enable the MTS-32 to run for longer than 40 hours. The MTS-32 is protected against reverse polarity connection by a diode inside the unit. 3.2 Selecting the power option 3.2.1 Connecting the MTS-32 to a 120 V/230 V electricity supply If the MTS-32 is to be connected to a 120 V/230 V power supply, the mains adaptor (MTS-5011) must be connected to the right-hand-side military-grade socket on the lid of the box (Figure 5). This connection is directly above the fan and air outlet.

Page 7 Figure 5: Plan view of MTS-32 (lid of box). Ensure that the male jack-plug connector leading from the fan outlet is connected to the left-hand external power in socket on the MTS-32 control panel (see Figure 9). Do not confuse this with the narrow, solid jack-plug that powers the fan. 3.2.2 Powering the MTS-32 using the integrated 12 V battery option If the MTS-32 is to be used with the integrated battery option (MTS-5009), ensure that the male jack-plug from the battery is connected to the right-hand socket labelled Battery Power in on the MTS-32 control panel. 3.2.3 Connecting the MTS-32 to an external 12 V battery If the MTS-32 is to be connected to an external 12 V battery, the external battery adaptor lead (MTS-5013) must be connected to the right-hand-side military-grade socket on the lid of the box (Figure 5). This connection is directly above the fan and air outlet. Ensure that the male jack-plug connector leading from the fan outlet is connected to the left-hand external power in socket on the MTS-32 control panel (see Figure 9). Do not confuse this with the narrow, solid jack-plug that powers the fan. 3.3 Powering the optional internal heaters To prevent internal condensation under foggy or 100% humidity conditions, a heater is suspended from the underside of the air inlet, and another is bolted to the main chassis. If required, these must be run from an independent 12 V power supply, connected to the left-hand military-grade socket on top of the MTS-32 lid (see Figure 5). The heater supplies 12 W, which will raise the temperature of the inlet air by about 10 C. This also enables the unit to run at ambient temperatures below 5 C. Note: Power for these heaters is supplied via a separate pair of shrouded sockets on the unit top, over the tubes. As this heater takes 1 A from the 12 V battery, it has been kept completely separate from the rest of the MTS-32 circuitry, and will require a separate power supply. A car battery of more than 25 A h capacity will drive the heaters for 24 hours. To connect the external battery to the MTS-32, an external battery adaptor lead is required (MTS-5013).

Page 8 4. Connecting the sampling pump The MTS-32 is designed to operate with an ACTI-VOC (C-LFP-01) or FLEC air sampling pump. These are constant-flow pumps that will deliver the same flow through tubes of different impedance. Constant-flow pumps from other manufacturers may be used, and a general-purpose pump socket is provided (Figure 6). However, Markes International should be consulted for advice regarding power and connection details, before you connect the pump. Figure 6: Plan view of MTS-32 (inside box). 4.1 Connecting the ACTI-VOC Connect the power inlet of the ACTI-VOC to the connection shown (Figure 6), using the cable (MTS-5019). Note: When then the MTS-32 is switched on, the level of current being supplied to the pump is shown on the gauge. The variable resistor should be adjusted to show no more than 100 ma. This can be done by turning the dial (Figure 7) anti-clockwise. Figure 7: Variable resistor dial. Connect the ACTI-VOC pump air inlet to the ⅛ copper tubing shown in Figure 2. Place the pump on the right-hand-side of the box, on top of the integrated battery (if present). Note: The back-pressure adaptor supplied with the ACTI-VOC should not be used with the MTS-32.

Page 9 4.2 Connecting the FLEC pump Connect the power inlet of the FLEC pump to the connection shown (see Figure 6). Note: When then the MTS-32 is switched on, the level of current being supplied to the pump is shown on the gauge. The variable resistor is only adjusted if the MTS-32 is being used with an ACTI-VOC or alternative pump. Connect the FLEC pump air inlet to the ⅛ copper tubing shown in Figure 2. Place the pump on the righthand-side of the box, on top of the integrated battery (if present). 5. Setting the timer As shown in Figure 8, the left-hand alphanumeric display denotes the mode of operation of the timer. This should always be set to B. The far-right-hand alphanumeric display denotes the unit of time (ranging from 0.1 s to 10 h). Figure 8: Timer display. The middle three alphanumeric displays denote the number of time units required per tube (i.e. a display of B030M denotes a sampling time of 30 minutes per tube). Note: Every sample tube in the sequence will be sampled for the same period of time, except for the last tube, which continues to be actively sampled until the pump is disconnected or turned off. To adjust the timer settings, lift one of the tabs above or below the display. Once the tab is in a vertical position, it can be pressed until the desired unit is displayed. The tabs above the alphanumeric (marked ) decrease the number, and those below (marked + ) increase the number. When each display has been set correctly, move the tab back to its horizontal position.

Page 10 6. Sample tube insertion Whichever number of sample tubes is to be included in the sequence, they should be loaded into positions 1 upwards. Conditioned and capped standard-sized tubes should have both caps removed and a DiffLok cap placed on the sampling (grooved) end. The tube should then be quickly inserted in the appropriate position in the MTS-32 tube manifold block. Note: Tubes should be unsealed and inserted into the manifold block one tube at a time. If using SafeLok tubes, a DiffLok cap is not required on the sampling end. Simply uncap the tubes and place into the tube manifold block. 7. Operation 7.1 Turning on the power Turn on the power to the MTS-32 by pressing the black on/off switch on the control panel (Figure 9). The motor driving the rotor may operate at this point, depending on its previous status. Press the red reset button on the control panel to ensure that the timer is in Standby mode. The LCD display should read off and the display should not blink. Figure 9: Control panel schematic. Push the manual switch away from the front of the box. This will cause the rotor to move to the final position (32) and then stop. 7.2 Summary of operation At switch-on, or after pressing the Reset button, the timer is in the reset state and nothing happens. At the beginning of the intended run, move the Manual override toggle switch S4 (Figure 9) forwards to bring tube 1 into the sampling position. The sampling position is indicated by the steel pointer on the rotor shaft.

Page 11 Operating the green Start button will cause the time to start counting down. This is shown by a flashing signal on the timer LCD. If a sample tube is in position 1 and the pump is connected, air will then be drawn into tube 1 for the allotted sampling time. After the preset time the motor drives the rotating pump connector plate under the tubes until the pump connector is located under tube position 2. This process is repeated in sequence up to tube position 32. If at any time the red left-hand Reset button (Figure 9) is pressed, the timer is stopped and reset. Note: When the reset button is pressed, the tube position doesn t change and the pump doesn t stop. Also note that if the sequence is restarted at this point (i.e. after the Reset button has been pressed), the sampling period for that tube will begin again at zero. Moving the Manual switch S4 backwards causes the motor to drive the rotor round to position 32, where it will stop. At this point, moving the Manual switch forwards causes the rotor to move from position 32 to 1. Under normal timer operation, the MTS-32 rotor stops at position 32. The sampling time for tube 32 is not set by the timer, and would not normally provide valid data unless the pump is stopped manually after exactly the right sampling tube period. 7.3 Turning on the pump to begin the sampling sequence Before switching on the sampling pump, work through the following checklist: 1. Check that power is connected and that the MTS-32 is switched on. 2. Check the pump is in place and connected (power and air inlet). 3. Check that tubes are inserted and capped with DiffLok caps if appropriate. 4. Check that the MTS-32 rotor is set at position 1. If not, follow the instructions in section 7.2, pushing the manual override switch backwards to set the rotor to position 32, then pushing the same switch forwards to bring the rotor to position 1. 5. Check that timer settings are correct for the sampling period required 7.3.1 Turning on the ACTI-VOC Switch on the pump using a pointed instrument such as a ballpoint pen to switch the ON/OFF switch (to the right of the pump s LCD display see ACTI-VOC user manual). Set the appropriate flow rate on the ACTI-VOC. Typical sampling rates are in the range 20 100 ml/min. Once the ACTI-VOC mode is switched to run, pumped air sample collection will begin through whichever tube is in the sampling position (as indicated by the stainless steel pointer). Press the green Start button to start the MTS-32 timer, and ensure that the timer starts to blink approximately once per second. Progress of the cycle is indicated by the bar graph on the timer LCD display (see Figure 8). Note: It is recommended that the pump flow rate is checked using a packed sample tube before connecting to the MTS-32. 7.3.2 Turning on the FLEC Switch on the pump by pressing the button marked with an indented circle (to the left of the pump LCD display see FLEC pump user manual).

Page 12 Set the appropriate flow rate and sample time on the FLEC pump. Typical sampling rates are in the range 20 100 ml/min. Note that the sample time should be long enough to cover the entire sequence of tubes (i.e. not just one time period). Note: The FLEC pump includes delay and no. of cycles settings. However, these are not applicable to MTS-32 operation, so these should be set to zero. Once the FLEC pump mode is switched to run (see manual), pumped air sample collection will begin through whichever tube is in the sampling position (as indicated by the stainless steel pointer). Press the green Start button to start the MTS-32 timer, and ensure that the timer starts to blink approximately once per second. Progress of the cycle is indicated by the bar graph on the timer LCD display (see Figure 8). Note: It is recommended that the pump flow rate is checked using a packed sample tube before connecting to the MTS-32. Note: The current being drawn by the pump (displayed on the meter, see Figure 6) will vary depending on the FLEC pump pulse rate. This, in turn, will vary depending on the tube impedance and required sample flow rate. 7.4 Finishing sampling sequence The cycle will continue through all loaded tubes up to position 32, regardless of the number of tubes loaded into the MTS-32, UNLESS stopped by the operator before this point. Pressing the on/off switch will stop power to the whole unit, thus stopping the timer, pump connector plate rotor and the pump itself. At the end of the cycle, remove each tube in turn and replace the storage caps firmly. 8. Battery charging If the system is to be re-used immediately, replace the battery pack with one that is fully charged. 8.1 Charger circuit for alternative constant-flow sample pumps Contact Markes International before selecting or using an alternative pump for use with the MTS-32. A special cable may be required. As standard pumps are only expected to run for 8 10 hours on internal batteries, a continuous charge facililty has been provided. To cover the wide range of pumps on the market, the charge current can be varied over the range 40 to 300 ma for battery voltages from 2.8 to 12 V. The required current is set by a variable resistor (the circuit is shown in Figure 10).

Page 13 Figure 10: Electrical schematic. The charging current is available on two outputs: one for the FLEC pump and one for alternative pumps. The choice of charge current must be determined from the pump manufacturer s data. In general, choose a value equal to the overnight charge rate from the mains-powered charger supplied with the pump. This is usually close to the running current and will not damage the pump battery if left connected for reasonable periods with the pump switched off. The output specifically designed to run the FLEC pump, which runs from a 12 V supply, does not have a means of varying the current. The other output has a variable control to provide the specific current recommended by the manufacturer of the pump selected. 9. User maintenance The only user-changeable items are the size 010 Viton O-ring seals under the O-ring retaining plate (see Figure 2). To access the O-rings, carry out the following: 1. Remove all sorbent tubes. 2. Remove screw on top of central rotor, and remove the stainless steel pointer. 3. Undo the four screws on the O-ring retaining plate on top of the tube manifold block. 4. Lift up the plate to give access to the O-rings. It is then possible to remove and replace the O-rings, before refitting the retaining plate and stainless steel pointer.

Page 14 10. Specifications 10.1 MTS-32 Dimensions Height: 17cm (6.7 ) Width: 30cm (11.8 ) Depth: 25cm (9.8 ) Weight 7kg (15.4lb) without pump and battery Power Requirements Mains: 120/230 V; 12 V adaptor supplied. Battery: Lead acid, 12 V, 10 A h. Sampling Flow Depends on pump used Sorbent-tube Compatibility 32 industry-standard tube (3½ ¼ o.d.). Environmental Operating Temperature: -10 o C to +55 o C Storage Temperature: -25 o C to +65 o C Humidity: 10% to 95% non condensing Note: Use of the optional heater will extend the humidity to 100% 10.2 Accessories - 12V Sealed Lead-Acid Battery - 12V Charger for Lead-Acid Battery - 12V Power Supply 10.2.1 Sealed Lead-Acid Battery (12V) Dimensions Height: 9.5cm (3.7 ) Width: 9.8cm (3.9 ) Length: 15.1cm (5.9 ) Weight 3.6kg (7.9lb) Approx Cells per Unit 6 Voltage per Unit 12 Capacity 12.0AH @ 20hr-rate to 1.80V per cell @ 25 o C

Page 15 Max. Discharge Current 180A (5 sec) Internal Resistance 14mΩ (Approx.) Operating Temperature Range Discharge: -15 to 50 o C (5 to 122 o F) Charge: 0 to 40 o C (32 to 104 o F) Storage: -15 to 40 o C (5 to 104 o F) Recommended Maximum Charging Current Limit 3.6A Self Discharge The battery can be stored for more than 6 months at 25 o C. Self-discharge ratio less than 3% per month at 25 o C. Please charge batteries before using. 10.2.2 Charger for Lead Acid Battery (12V) Dimensions Height: 3.65cm (1.4 ) Width: 6.7cm (2.6 ) Length: 10.7cm (4.2 ) Weight 250g (0.55lb) Input Voltage 90-264VAC Maximum Output Power 35W Temperature Range -10 to +40 o C 10.2.3 Power Supply (12V) Dimensions Height: 3.6cm (1.4 ) Width: 3.8cm (1.5 ) Length: 9.1cm (3.6 ) Weight 165g (0.36lb) Input Voltage 90-264VAC Maximum Output Power 15W

Page 16 Temperature Range Operating: 0 to +70 o C Storage: 0 to +85 o C