Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Similar documents
Type DTH 31, 32 DTTM 11, 12 High Speed Biased Differential Relays

Trip Circuit and Trip coil supervision Relay

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B. Station Automation & Protection. ABB Substation Automation Products

2.0 CONSTRUCTION AND OPERATION 3.0 CHARACTERISTICS K. CO (HI-LO) Overcurrent Relay

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

COM Overcurrent Relay

ABB Power T&D Company Inc. Relay Division Coral Springs, FL Allentown, PA. Non-Directional, Single Phase Adjustable Time Delay Device No.

CHAPTER 4 PROTECTION REQUIREMENTS

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

KD LV Motor Protection Relay

ABB ! CAUTION. Type KRV Directional Overcurrent Relay E 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION. Instruction Leaflet

PRODUCT / TEST MANUAL 2C58K2 INSTANTANEOUS OVERCURRENT

TECHNICAL SPECIFICATIONS OF PCC PANEL

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DIN Panel Meters Long Scale

L. Photo. Figure 2: Types CA-16 Relay (rear view) Photo. Figure 1: Types CA-16 Relay (front view)

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

PIX-H Metal-clad switchgear up to 17.5kV

LA Motor Protection. A South African Company to be Proud of

Bulletin 825 SMM Smart Motor Manager

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DPX moulded case circuit breakers

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

AP/UP, AP/MIL Series Magnetic Circuit Protectors

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Single Pole Circuit Protectors 55. Multi-Pole Circuit Protectors 56. Configurations 58. Operating Characteristics 59.

A - Add New Information C - Change Existing Information D - Delete Information. Page 7. Delete the fourth paragraph beginning CAUTION

ABB. Type CRQ Directional Negative Sequence Relay for Ground Protection B 1.0 APPLICATION 2.0 CONSTRUCTION AND OPERATION CAUTION

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Pretest Module 29 High Voltage Unit 1

Metrosil / Resistor Module Features Application Operation

B CW POWER RELAY

Intelligent Choice for Prestigious Buildings

CP Automatic capacitor bank

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Thermal Overcurrent Circuit Breaker 3120-F...

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

Dual Power. Protection. Protection

SICOP. Bimetal Overload Relays Type 3UA5/6 & 3UC5/6. Introduction. Application

Figure 1. Type CWP-1 Ground Relay (Front View) Figure 2. Type CWP-1 Ground Relay (Rear View) E

320 to 327 M Series Low and Medium Voltage Motor Protection Relays

SE-125 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

PRODUCT/TEST MANUAL 2C58K37 INSTANTANEOUS OVERCURRENT RELAY

Thermal Overcurrent Circuit Breaker 3120-F...

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

PLATINUM SERIES SWITCHBOARD METERS

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

APPENDIX E. Electrical System Single Line Diagram Overcurrent Protection Study Overcurrent Protection Device Specifications

01 Spectra Plus - Introduction

Moulded Case Circuit Breakers

C. Figure 1. CA-16 Front View Figure 2. CA-16 Rear View

cor Long Run Experience

ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065

DPX 1600 Electronic release

Technical information

Thermal Overcurrent Circuit Breaker 3120-F...

6R MATRIX. Modular Relays. rms. Auxiliary, Trip & Supervision Relays

(Example) In case of DC24 to 48V, it is operating time for DC24V.

Century Style Analog Panel Meters

Thermal Overcurrent Circuit Breaker 3120-F...

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

DC POWER SUPPLY SYSTEMS

A200 NEMA Contactors and Starters A200

JAE Series. Magnetic Circuit Protectors. Introduction Poles Configurations Operating Characteristics Delay Curves Decision Tables

Thermal-magnetic Miniature Circuit Breaker 4230-T...

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

(High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA MATERIALS MANAGEMENT / CAPITAL EQUIPMENT. Enquiry Date:

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Memshield - ACB Ratings & Specifications

Thermal Overcurrent Circuit Breaker 3120-F...

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Moulded case circuit breakers

PSW102 type CT powered protection unit

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Thermal Overcurrent Circuit Breaker 3120-F...

QF(13) - Series Miniature Circuit Breakers

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

MRTS Trip Circuit Supervision Relay

Wide-Vue Analog Panel Meters

Industry Automation Control Components

Essential equipment for all your requirements

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

PORTABLE CURRENT SOURCE FOR CIRCUIT BREAKER AND MOTOR OVERLOAD TESTING INSTRUCTION MANUAL PI-250B. Release 1.0 April 5, 2013

DD Frame - Series Circuit Breakers

Paramount HRC Cartridge

SECTION MOTOR CONTROL

AR circuit breaker - Hydraulic magnetic,

Thermal Circuit Breaker 3120-F...

Transcription:

Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Type DG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay DG 14 drawn out from the case The type DG 14 relay is a heavily damped induction disc unit with an extremely inverse definite minimum time/current characteristic. The relay gives selective phase and earth fault overcurrent protection in time graded systems to transformers, ac machines and fuses (see Application Sheet R-5087) The operating coil is wound to give time/current curves of the same shape on each of the seven current taps which are selected by a plug setting bridge. The highest current tap is automatically selected when the plug is removed, so that adjustments can be made on load without opencircuiting the current transformer. The relay has a high torque movement to ensure consistent timing even under adverse conditions, and a low burden and overshoot. Adjustment of the time setting is made by rotating a knurled moulded disc against a graduated time multiplier scale. A high set overcurrent unit (type AG) can be fitted in the same case to provide instantaneous protection under maximum short circuit conditions (see Application Sheet R-5087). The type DG 24 relay is a DG 14 with an instantaneous unit. The type DG 34 relay is a triple pole version (with three overcurrent units or two overcurrent units and one earth fault unit in the centre) of the type DG 14. urrent settings Graded tap ranges 10-40%, 20-80% or 50-200% of 0.5, 1.0 or 5.0 amps and 30-120% or 80-320% of 5 amp 50 or 60Hz adjustable in seven unequal steps as follows: 25%, 30%, 37.5%, 50%, 60%, 75% and 100% of top tap value. Starting current 103-110% of current setting. losing current Less than 130% of current setting. Resetting current The maximum current up to which disc will completely reset is 90% of current setting. Time settings 0-0.6 second at 10 times current setting (see characteristics fig.2). Resetting time 45 seconds with the time multiplier set at 1.0. Overshoot 0.05 second on removal of a current equal to 20 times current setting Burdens 0.5VA at current setting on lowest tap. 1.5VA at current setting on highest tap. Impedance details for coils can be supplied on request.

Thermal rating The relay will withstand twice the setting current continuously and 20 times the maximum setting current for 3 seconds. Accuracy The relay is calibrated at 50Hz or 60Hz and 20 and falls into error class index E7.5 as given in B.S.142:1966. Frequency error Less than 8% for frequency variation of 2Hz; the time grading of a protective system would be unaffected by the error since all the relays would be similarly affected. Temperature error For an overload equal to 10 times the current setting, the percentage timing errors at +45 and 5 are respectively 3% and +5%. Auxiliary units and operation indicators An auxiliary attracted armature unit with a hand reset operation indicator, for either shunt reinforcing or series seal in is fitted as standard. ontacts Two electrically separate normallyopen self or hand reset contacts are fitted which will make and carry 7500VA for 0.5 second with maxima of 30 amps and 660 volts ac or dc in the case of shunt seal and maxima of 15 amps and 660 volts ac or dc in the case of series seal. A Trip circuit Where a tripping supply is not available, a modified relay can be supplied which trips the circuit breaker directly using current from the line transformer. The ac tripping circuit incorporates a current transformer and an instantaneous unit which will safely control ac trip coil currents up to 150 amps at 150 volts. Applications where the trip current exceeds this value can also be catered for. Standard coil ratings Voltage operated (shunt) auxiliary units: 30, 110, 125 or 220 volts dc at a nominal burden of 3 watts continuously rated. urrent operated (series) auxiliary units: Minimum operating 0.5 second oil current in amps current resistance (two taps) rating in amps in ohms 0.1 and 0.3 18 and 22 9.2 and 2.1 0.2 and 2.0 22 and 92 6.0 and 0.125 0.6 and 2.4 92 and 188 0.29 and 0.031 Other coil ratings can be supplied for both types of auxiliary unit. A B 1 Alarm Note: All three elements are the same and only one is shown. Alarm and trip TS are paralleled. A B T connection for overcurrent and earth fault protection 2 Trip T. 3 4 T1 5 A Trip T. Isolator T2 6 T1 Three phase overcurrent protection S1 S2 S1 7 B T2 8 S2 T1 S1 9 10 T shorting contacts Figure 1: Typical application and internal circuit diagram of DG 34 relay with series seal in. S2 5 6 7 8 9 10 O/ E/F O/ T2

Technical data for AG 13 urrent rating 1A or 5A. Settings 500 2000% } 400 1600% 200 800% 100 400% Resetting current The relay will reset at approximately 15% of current setting. Operating time Approximately 10 milli seconds at 5 times current setting. Burdens 1.4 VA at lowest current setting to 18 VA at highest current setting. VA burdens given above are applicable to all setting ranges. Thermal rating The relay will withstand 1.5 times the minimum current setting continuously and 12 times the maximum current setting for 3 seconds. Accuracy The relay conforms to error class index E 10.0 as per B.S.142:1966. Operation indicator The relay is fitted with an operation indicator which is hand reset by means of a push-rod protruding through the relay case. ontacts 2 make self reset. at rated current continuously adjustable Technical data for AG 19 urrent rating 1A or 5A. Settings 500-2000% 400-1600% 200-800% 100-400% Resetting current Not less than 80% of current setting. Operating time Less than 30 milli seconds at 5 times setting current. Resetting time Within 30 milli seconds when resetting to no current. Transient overreach Less than 1% for system angles upto 88 on all settings. Burden } 1.0 VA on lowest setting 3.0 VA on highest setting Thermal rating ontinuous : Maximum setting current Short time : 20 x max. setting current for 3 seconds Accuracy Error class index ontacts 2 make self reset. } at rated current continuously adjustable at setting current : E 5 as per BS.142:1966

ases Relays are supplied in drawout cases designed for either flush or projecting mounting. ase wrappers are manufactured from hot dipped galvanised steel with a black pvc outer coating. Relays comply with 56 day humidity requirements as specified in IE68. limatic category 20/50/56. Insulation The relay will withstand 2.0 kv rms, 50Hz for one minute between all terminals connected together and the case, between all terminals not intended to be connected together and 1.0 kv rms, 50Hz for one minute between all normally open contacts. Information required with order 1. Relay type. 2. urrent setting range. 3. urrent transformer secondary rating. 4. Trip current (series seal in, shunt reinforcing or ac). 5. Trip circuit current (series seal in). 6. Trip circuit voltage (shunt reinforcing). 7. Operation indicator inscription if required. 8. Auxiliary contacts (hand or self reset). 9. Details of instantaneous unit (AG) if required. 10. ase mounting. Operating times in secs. 20 10 9 8 7 6 5 4 3 2 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 ase dimensions 2 3 4 5 6 7 8 9 10 Multiplies of plug setting current 20 30 Figure 2: Time-current characteristic. Extremely inverse DG 14 1.0 0.9 0.8 0.7 0.6 0.5 0.1 40 Maximum overall dimensions Relay ase Height (mm) Width (mm) Depth* (mm) DG 14 1D 237 173 218 DG 24 DG 24 2D 425 174 218 (double-pole) (Vert) 3D 527 174 218 DG 34 (Vert) 3D 238 458 218 (Horiz.) * Add 7 mm for maximum length of M5 terminal screws. Dimensioned drawings of case outlines, panel cut-outs and mounting details are available on request. 0.4 0.3 0.2

ALSTOM Limited Pallavaram Works: 19/1, GST Road, Pallavaram, hennai-600 043. India. Tel: 91-044-2368621 Fax: 91-044-2367276 Email: plw.applications@alstom.sprintrpg.eml.vsnl.net.in. 1998 ALSTOM Limited Our policy is one of continuous development. Accordingly the design of our products may change at any time. Whilst every effort is made to produce up to date literature, this brochure should only be regarded as a guide and is intended for information purposes only. Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. ALSTOM Limited cannot be held responsible for any reliance on any decision taken on its contents without specific advice. PR:014:0799:A Printed in India.