ABB i-bus KNX Hotel IP Link, Bundle HIL/S , 2CDG110237R0011

Similar documents
ABB i-bus KNX HIL/S , Hotel IP Link, Bundle

ABB i-bus KNX DG/S x DALI-Gateway Basic

ABB i-bus KNX Magnetic Contact EnOcean, 868 MHz MKE/A , 2CDG R0011

Thermal overload relay TF140DU and TF140DU-V1000

Thermal overload relay TF65 and TF96

Electronic overload relay EF65, EF96 and EF146

Electronic overload relays EF205 and EF370

Mini contactors B6, BC6 with 3 pole

Manual motor starter magnetic only MO325

ABB i-bus KNX Room Master, MDRC RM/S 4.1, 2CDG R0011

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter MS132

Manual motor starter MS116

Manual motor starter MS116

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Manual motor starters Overview and benefits

ABB i-bus EIB EIB Power Supply Units SV/S SV/S SU/S

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Emergency-off application Manual motor starter MS116/MS132 Undervoltage release UA1

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Motor Starter Reverse MSR22-FBP

Selective main circuit breakers S 750 series Technical Data

Mini Contactors Applications and Segments

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Moving Coil Indicators with direct temperature sensor input

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

EAS822 (Contrac) Power Electronic Unit

ZS4-D2-S-T Screw Clamp Terminal Blocks Double deck with 1 disconnect circuit with test socket screws and 1 feed-through circuit

Thermal Overload Relays

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

Technical Description. Wireless Automation Accessories

Electronic Circuit Breaker ESS20-0..

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK2.5-SF-R PI-Spring Terminal Blocks For 5x20 fuses - with blown fuse indicator

ZS6-D1-PE Screw Clamp Terminal Blocks Double deck with 1 ground circuit

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

Brochure. Motor protection and control DRAS enclosed direct-on-line starters

ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

PRODUCT BROCHURE. ABB Ability Wireless Monitor for surge arrester Enabling reliability and availability of power supply

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZK2.5-D-CH PI-Spring Terminal Blocks Component holder

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

ZS10 Screw Clamp Terminal Blocks Feed-through

Product information. ECOSS Electronic compact starter for wound rotor drives

Voltage limiting device HVL

ZP2.5-PE Spring Terminal Block Ground

ZK2.5-SP PI-Spring Terminal Blocks Disconnect with plug - with test sockets

ZS4-PE Screw Clamp Terminal Blocks Ground

TriLine PowerModules Overview with Planing Examples

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4 Screw Clamp Terminal Blocks Feed-through

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Low Voltage Systems MNS and MNS is PowerCenter

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

ABB central inverters PVS to 2091 kva

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Voltage limiting device HVL

ZS6 Screw Clamp Terminal Blocks Feed-through

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

ZS4-T3 Screw Clamp Terminal Blocks Triple deck with 3 feed-through circuits

ZS10-PE Screw Clamp Terminal Blocks Ground

ZS6-4S Screw Clamp Terminal Blocks Feed-through with 4 connections

Emergency stops Award winning design

ZS50-PE Screw Clamp Terminal Blocks Ground

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. 9QGPS5500 Wire rope load cell

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade

ZS4-PE Screw Clamp Terminal Blocks Ground

Control and Automation. AC500 - your PLC for solar systems Change for more energy efficiency

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Short form catalogue Motor protection and control Manual motor starters

Model WEP Electro-pneumatic positioner. WEP positioner A valve control without compromise

ZK2.5-4P PI-Spring Terminal Blocks Feed-through with 4 connections

MEDIUM VOLTAGE PRODUCT. KECA 250 B1 Current Sensor Instructions for installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. KECA 80 C85 Current Sensor Instructions for installation, use and maintenance

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

ZS35 Screw Clamp Terminal Blocks Feed-through

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

ZK6 PI-Spring Terminal Blocks Feed-through

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

ZK2.5-D1-PE PI-Spring Terminal Blocks Double deck with 1 ground circuit

Surge arrester POLIM-H.. ND

Surge arrester POLIM-C.. HD

PQstorI One stop solution for energy storage and power quality

DBL distribution blocks 3x1 pole

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

ZK4-PE PI-Spring Terminal Blocks Ground

Transcription:

Technical data 2CDC502097D0201 ABB i-bus KNX Product description HIL/S 20.1.1 The Hotel IP Link is used to connect zones of up to 20 KNX TP devices with central systems (such as Visualizations or Hotel Management Systems). The bundle consists of 2 components: SV/S 30.200.3.1 Power Supply Zone The KNX power supply generates and monitors the KNX system voltage (SELV). The bus line is decoupled from the power supply by an integrated choke. The voltage output is short-circuit and overload protected. The two-color LED indicates device output status. The additional 30 V DC short-circuit and overload protected voltage output is used to power the IPS/S 2.1. IPS/S2.1 IP Interface The IP Interface is a modular installation device (MDRC) and forms the interface between KNX installations and IP networks. KNX devices can be programmed via the LAN using ETS 3.0f or higher. The device uses the KNXnet/IP protocol from the KNX Association (Tunnelling). The IP address can be fixed or can be received from a DHCP server. The power supply range is from 10 to 30 V DC.

Technical data SV/S 30.200.3.1 Supply Supply voltage U s 85 265 V AC, 50/60 Hz Power consumption Normal operation Maximum 12.5 W 30 W Power loss Normal operation Maximum 2.5 W 6 W Ausgänge KNX voltage output U n1 1 line with integrated choke for 20 devices Rated voltage U n1 30 V DC +1/-2 V, SELV Voltage output U n2 Rated voltage U n2 without choke 30 V DC +1/-1 V, SELV The voltage output without choke may only be used to power the IPS/S 2.1. Current Rated curr. Overload curr. Short-circuit curr. I n1 I ÜL I K 200 ma 0.4 A 0.7 A Power failure buffering time 100 ms Connections KNX Bus connection terminal Mains voltage input and Auxiliary Output U n2 Tightening torque Screw terminal 0.2 2.5 mm 2 fine-strand 0.2 4 mm 2 solid Maximum 0.6 Nm Operating and display elements LED status (two-colored green/red) Green: U n1 = Ok, I < I ÜL Red: overload Red, flashing: short-circuit Degree of protection IP 20 to DIN EN 60 529 Protection class II to DIN EN 61 140 Isolation category Overvoltage category III to DIN EN 60 664-1 Pollution degree 2 to DIN EN 60 664-1 Temperature range Operation -5 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, Pro M Main dimensions (H x W x D) Mounting width Mounting depth 90 x 72 x 64.5 mm 4 x 18 mm modules 64.5 mm Mounting On 35 mm mounting rail to DIN EN 60 715 Mounting position Weight Housing, color As required Approx. 0.26 kg Plastic housing, gray Approvals KNX under EN 50 090-1, -2 CE mark In accordance with the EMC guideline and low voltage guideline 2 2CDC502097D0201 HIL/S 20.1.1

Important If the device overheats due to extended overload (> 100 C in housing) it switches off automatically. The LED is off. The device can be switched on again only after it has been disconnected from the mains for 60 seconds and has cooled to operational temperature internally. Eliminate the cause of the overload before switching back on. When commissioning the device, ensure that the rated current is not continuously exceeded. The voltage output without choke (U n2 ) is not electrically isolated from the KNX voltage output (U n1 ). It may only be used to power the IPS/S 2.1. Devices are designed for continuous operation. They are not approved for frequent switching on and off. HIL/S 2 0.1.1 2CDC502097D0201 3

Technical data IPS/S 2.1 IP Interface Supply Supply voltage U s 10 30 V DC via plug-in terminal Power consumption Current consumption Leakage loss Rated voltage U n Rated current I n Current consumption KNX Ripple: < 5 % Maximum 1.9 W at 10 V Maximum 190 ma at 10 V Maximum 1.9 W at 10 V 12 V DC 145 ma at 12 V From KNX < 10 ma Connections KNX Bus connection terminal Plug-in terminal for operating voltage LAN Plug-in terminal RJ45 socket for 10/100BaseT, IEEE 802.3 networks, AutoSensing Operating and display elements LED red and button For assignment of the physical address LED green LED yellow Operating mode display Network connection indicator KNX telegram traffic indicator Enclosure IP 20 to DIN EN 60 529 Safety class II to DIN EN 61 140 Isolation category Overvoltage category III to DIN EN 60 664-1 KNX safety extra low voltage Pollution degree 2 to DIN EN 60 664-1 SELV 24 V DC Temperature range Operation 0 C +45 C Storage -25 C +55 C Transport -25 C +70 C Ambient conditions Maximum air humidity 95 %, no condensation allowed Design Modular installation device (MDRC) Modular installation device, Pro M Dimensions (H x W x D) Mounting width Mounting depth 90 x 36 x 64 mm 2 modules at 18 mm 68 mm Installation On 35 mm mounting rail to DIN EN 60 715 Mounting position Weight Housing, colour as required 0.100 kg Plastic housing, grey Approvals KNX to EN 50 090-1, -2 CE mark in accordance with the EMC guideline and low voltage guideline Application program Maximum number of communication objects Maximum number of group addresses IP Interface 0 0 0 Maximum number of associations Note The programming requires EIB Software Tool ETS3 V3.0e or higher. If ETS3 is used a *.VD3 or higher type file must be imported. The application program is available in the ETS3 at ABB/System devices/interfaces. The device does not support the closing function of a project or the KNX device in the ETS. If you inhibit access to all devices of the project with a BCU code (ETS3), it has no effect on this device. Data can still be read and programmed. 4 2CDC502097D0201 HIL/S 20.1.1

Connection 10 1 U s 2 3 L N 0.6 Nm Us = 100-240 V AC 50 / 60 Hz t a = 45 C Un1 Un2 11 green: Un OK red: Overload 13 12 0.6 Nm IPS/S 2.1 U n2 = 30 V DC U n1 = 30 V DC I n2 = ISupply IPS/S I n1 = 200 ma 1 ON LED 2 LAN/LINK LED 3 Telegram LED 4 Supply voltage connection 5 Bus connection terminal 6 Programming LED 7 Programming button 8 Label carrier 9 LAN connection 10 Power supply connection U s 11 Status LED 12 IPS/S 2.1 connection 13 without function HIL/S 2 0.1.1 2CDC502097D0201 5

Dimension drawing 108 1 Us 2 3 L N 0.6 Nm Us = 100-240 V AC 50 / 60 Hz t = 45 C a Un1 Un2 0.6 Nm IPS/S green: Un OK red: Overload U n2 = 30 V DC I n2 = ISupply IPS/S U n1 I n1 = 30 V DC = 200 ma 2CDC072030F0017 6 2CDC502097D0201 HIL/S 20.1.1

Notes HIL/S 2 0.1.1 2CDC502097D0201 7

Contact us ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Telefon: +49 (0)6221 701 607 Telefax: +49 (0)6221 701 724 E-Mail: knx.marketing@de.abb.com Further Information and Local Contacts: www.abb.com/knx Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of this contents - in whole or in parts - is forbidden without prior written consent of ABB AG. Druckschrift Nummer 2CDC502097D0201 (05/2017) Copyright 2017 ABB All rights reserved