VDCI mixproof valve technical description

Similar documents
DPX - DPAX butterfly valve technical description


PROCESS EQUIPMENT COMPANY. Manufactured by: Group Defontaine Saint Herblain Cedex, France.


Security device Non return valve

Guth modulating valves. The sophisticated solution

PNEUMATICALLY ACTUATED 2-WAY

The pumping action of the B series lobe displacement pump is achieved thanks to the counter-rotation of

BIOVENT. Hygienic Valve

CATALOG. Actuated Diaphragm Valve DN PVC-U / PVC-C / PP-H / PVDF / ABS SMART IN FLOW CONTROL.

The figure 269J is a double seal mix-proof piston valve, used for product isolation, where safe separation of process and C.I.P. fluids is required.

SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm

485 - NC NO/DA DN

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

CATALOG. 2/2 - Way Angle Seat Valves SMART IN FLOW CONTROL.

BRONZE ZEUS PNEUMATIC ANGLE-SEAT VALVE

Pressure Reducing Valve Type 2114/2415

Series 240 Pneumatic On-off Valve Type 3351

Standard Duty A.T.S.A. - Temp Desuperheater Model 24 / 34

GERMAN QUALITY VALVES

NARVIK-YARWAY. Heavy Duty A.T. - Temp Desuperheater Model: 18/54 and 28/64

Diaphragm Valve, Metal

Order Code for GEA Tuchenhagen VESTA Sampling Valves. Typ H_A/I 2/2 Way Seat Valve

kyalfa Laval Unique DV-ST UltraPure

YARWAY NARVIK STANDARD DUTY A.T.-TEMP DESUPERHEATER MODEL 38/48

The Original Seat Valve

Air Operated Valve Control Valve

UNIDIRECTIONAL Knife Gate Valve

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

Angle Seat Globe Control Valve, Metal

+ = Angle-seat Valve System for continuous control. Type 8802/2300 electro-pneumatically operated angle-seat valve

2/2-Way and T Valve Bodies in Stainless Steel

Butterfly valves for high temperature series GD(H) - LDK

MULTI-FLUID SOLENOID VALVES 1/8 AND 1/4

EDELSTAHL. Kämmer Series Aseptic and Sanitary Valves

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

Diaphragm Valve, Metal

T-smart Butterfly Valves. Made by GEA Tuchenhagen. GEA Mechanical Equipment / GEA Tuchenhagen

Angle Seat Globe Control Valve, Metal

Pig-cleaning systems. for food stuffs industry beverage industry pharmaceutical industry cosmetic industry

DK/CP DN PVC-U / PVC-C / PP-H / PVDF. Pneumatically actuated 2-way diaphragm valve

Series 240 Type 3349/3379 Pneumatic Control Valve Type 3349 Aseptic Angle Valve

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

PF6 Stainless Steel Piston Actuated On/Off Valves

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE. Model/Ref:

26220, 26230, For single- and double-acting drives. Standard manual override with detent. Compact design. Exhaust air silencers.

Angle Seat Valve /2" up to 3"

Centred disc butterfly valve with elastomer liner. Wafer type body Full -lug type body

kythe Original Aseptic Seat Valve

Magnetic-Inductive Flow Meter FMI

F269B+ HYGIENIC BALANCED DOUBLE SEAL VALVES REVERSIBLE ACTUATOR TYPE PENTAIR HYGIENIC PROCESS VALVES (FORMERLY KEYSTONE)

Hovap series 8700 Hygienic Mixproof Process Valves Varioflow

back to main page Type: Butterfly valves Instructions and Operation Manual Warning! Warning! Danger for life! 1. Intended use Danger for life!

SOLENOID VALVES AND PNEUMATIC VALVES

Heavy Duty Que - Temp Desuperheater Model: 13 / 23

Magnetic-Inductive flow Meter fmi

Double Seat Valves Double Seat Blanking Plugs. Hygiene

Every component precisely matched

Valve Manifolds Type 44 VTSA, Type 45 VTSA-F Inch Series Overview

650TL. Diaphragm Valve, Metal. Special version "TL"

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

2/2-Way and T Valve Bodies in Stainless Steel

UNIDIRECTIONAL Round Guillotine Damper

Gateway Type Serial Transmission System

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Pneumatic Control Valve Assembly Type 3331/3278

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE

BIDIRECTIONAL WAFER Knife Gate Valve

PF6 Stainless Steel Piston Actuated On/ Off Valves

Diaphragm Valve, Metal

All From One Source Hydraulic Closed Loop Control Systems for Gas and Steam Turbines

Standard Duty Que - Temp Desuperheater Model: 33 / 43

Pneumatic operated 2/2-way Diaphragm Valve

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

Air Operated Diaphragm Pumps for Sterile Applications within Pharmaceutical, Biotechnical and Food Industry

Tank Bottom Valve, Metal

EDELSTAHL a. Flow Control Division. Kammer Control Valves. Kämmer Series Kämmer Series Aseptic and Sanitary Valves

Operating Instructions

SOLENOID CONTROL VALVE

WEDGE & SLAB GATE VALVES

Series V2001 Valves Clean Tech Type 3321CT Globe Valve with pneumatic actuator

ID & IP SERIES IN-LINE DISC AND PISTON VALVES

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

3/2-Way Valve DN 15 up to DN 50

Mars Series 88 Stainless Steel Reduced Bore Or Full Bore Ball Valve, Lever Operated, BSP Or Socket Weld Ends

BR 20b Ball valve. PFA-lined. Application: Versions:

Angle Seat Globe Control Valve, Metal

T EN Type 3347/3379 Pneumatic Control Valve Type 3347 Hygienic Angle Valve

653, 654. Diaphragm Valve, Metal

PRESSURE REDUCING AND DESUPERHEATING STATIONS SERIES

IN-LINE DISC & PISTON VALVES

555 Connection code 80 / Valve body material code C2. Angle Seat Globe Valve, Metal Aseptic

SCAN TO VIEW PRODUCT ANIMATION. D4 Series DOUBLE SEAT MIX-PROOF VALVES

CIRCLE SEAL CONTROLS

Operating Instructions

Spare Parts. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm SP70811-GB

Transcription:

VDCI mixproof valve technical description The VDCI mixproof valve performs two primary functions: the orientation of fluids in the same way as the standard DCX3-DCX4, the bleeding of an air space between the plugs which is intended to: 1 direct the leakage flow out of the system and thereby prevent the mixing of two fluids flowing through the valve. 2 warn the user should there be a seal failure on either of the plugs. This technology creates a physical barrier between the two fluids allowing different type of fluid to flow through the valve. For example, one of the body compartments can be washed out while the other continues to convey a process fluid. What's more, by activating the plugs, the valve can be washed completely at the same time as the various pipelines. A single valve can therefore be used on circuits which traditionally required two single-sealing valves. Mixproof valve technology is constantly changing. The latest versions guarantee minimal product loss and risk of circuit contamination by the air space. These valves have successfully passed the EHEDG tests. 4

VDCI mixproof valve technical description Design The VDCI mixproof valve consists of six main subassemblies: a spherical body with branch outlets providing a variety of configurations, a one-piece lower plug equipped with a pressure counterbalance, a one-piece concentric upper plug (with floating seal), a single-acting main actuator incorporating an auxiliary upper plug break-away actuator, a complementary lower plug break-away module and a lower plug counterbalance guard. These elements are clamped together for good centring and quick removal (from DN 38 to DN 1). Thanks to the design and quality of manufacture, the components are fully interchangeable. The body The VDCI body is made from 316L stainless steel according to a technique that ensures a good level of homogeneity in the material. The spherical form of the bodies ensures optimum fluid flow and a reduction in pressure losses. Its extra-thick walls guarantee excellent mechanical strength as well as a sturdy valve assembly and therefore a firm support for the plugs on their bearing surface. This allows the design of important manifolds, without expansion device. The polished interior finish (Ra = 0,8 µm) contributes to outstanding in-line cleanability. The branch pipes welded to the body provide standard combinations as well as special configurations on request. Each nominal diameter corresponds to a particular sphere diameter guaranteeing minimum fluid retention inside the valve. Final hyperquenching regenerates the stainless steel and contributes to the geometric quality of the body. 5

VDCI mixproof valve technical description Examples of the most common body configurations These valves are designed as standard for vertical operation and ensure a natural fluid flow from the air space. However a slight incline (approx. ) is possible. Type 01 Type 02 Type 03 Type 04 Type 05 Type 06 Type 07 Type 08 Type 09 Type Type 11 Type 12 Type 13 Type 14 Type 15 Type 16 Type 17 Type 18 Type 19 Type 20 Type 21 The plugs 6 The one-piece lower and upper plugs are made from 316L stainless steel. The design and the quality of surface finish reduce pressure losses. The stem and counterbalance are chromiumplated and guided by rings. Apart from the PFA plug seals, valve seals are supplied in standard food grade materials. A leakage indicator in the actuator lantern warns the user of a possible failure of the upper plug seals. The lower plug is equipped with two concentric leakage chambers communicating with the inter-plug air space. The lower end of these chambers is threaded to take a flexible nozzle used for washing or internal sterilisation of the leakage chambers.

VDCI mixproof valve technical description The floating seals A PFA (PerFluoroAlcoxy) floating seal is clipped into each plug housing. Its floating arrangement makes for outstanding cleanability. On dilating, it allows circulation of the cleaning fluid around all sides. Its plastomer structure also guarantees the absence of porosity or cracking, which can be sources of contamination and bacteria development. The main actuator The main VDCI actuator is composed of an outer 304L stainless steel cylinder, a lantern and a body mounting plate, pistons using the lower and upper plug stems, springs with an anticorrosion coating and a base held by a stainless steel retaining ring screwed onto the lantern. It is delivered as standard with adjustable air fittings for 4/6 or 6/8 hoses. The main actuator is supplied from the side whereas the upper plug break-away actuator is supplied from the underside of the actuator. Note : 1. Removing the internal breakaway piston does not change the outer appearance. 2. An M18 detection lantern can be fitted directly. The break-away actuator This complementary module is designed for the lower plug breakaway function. It has a 304L stainless steel body and is positioned above the main actuator. The break-away piston is attached to the lower plug stem. The counterbalance protection unit The one-piece 316L stainless steel guard fits under the valve body and provides effective protection of the lower plug counterbalance. A liquid or steam circulation system can be added as an option. 7

VDCI mixproof valve technical description VDCI mixproof valve features Modular break away actuator allows lifting of the lower plug. Compact actuator without external flanges, with springs to ensure a high nominal sealing. Break away piston of the upper plug. Optional switches on the lantern. Leak detection o'ring. Assembly of an aseptic plate possible. Upper and lower plugs equipped with PFA floating seal ensures maximum cleaning. Sealing due to a pinched seal for complete cleaning. Double wall leakage indicator with possible cleaning of the plugs on each bearing face. Counterbalance ensuring resistance against water hammer. Actuators and shut-off units clamped together for quick removal. 8 Sealing due to a flush seal for complete cleaning. Perfect guidance of the counterbalance due to plastomer o'rings. Extra thick body ensuring high resistance against mechanical and thermal distortions ; the spherical shape reduces pressure drop. Solid counterbalance cover. Assembly of an aseptic plate possible.

VDCI mixproof valve operation Process: valve closed with a leak Valve closed with a leak on one of the plug seals (leakage flow illustrated). Leak Air Leak Process: open valve Valve open, with a leak on the inter-plug seal. 9

VDCI mixproof valve operation Washing of the lower chamber Air Washing the lower chamber with the lower plug in operation. Washing Air Washing Washing of the upper chamber Washing the upper chamber with the upper plug in operation.

VDCI mixproof valve operation Washing of the air space Washing the air space by forced circulation in the leakage chambers. 11

VDCI mixproof valve dimensions Ø H F Tube Ø A I C D E G (Required space for disassembly) 12 B B

SMS 38 51 63 76 4 * Without control unit 1 6" 152,4 x 2,75 200 180 576 60 3 20 270 139 154 x 2 200 180 576 60 3 20 270 139 0 125 4" 1,6 x 2,1 155 125 465 234 4 x 2 155 125 465 234 129 x 2 200 155 556 60 3 80 7 218 1 795 218 120 795 218 120 9 270 129 78 87 87 135 145 145 3" 76 x 1,65 130 95 407 41 204 85 x 2 155 1 455 234 65 70 x 2 130 90 402 43 204 76 x 2 130 95 407 41 204 2" 1/2 63,5 x 1,6 130 85 400 35 204 63,5 x 1,65 130 85 400 35 204 640 167 95 640 167 95 6 167 97 665 167 0 665 167 0 2" 53 x 1,5 5 70 358 35 179 565 128 80 51 x 1,25 5 70 358 35 179,8 x 1,65 5 70 358 35 179 565 128 80 565 128 80 1" 1/2 40 40 x 1 5 55 353 25 179 530 128 72 38 x 1,2 5 55 353 25 179 38,1 x 1,65 5 55 353 25 179 530 128 72 530 128 72 22 22 22 22 22 22 43 43 43 43 43 DN DIN US Tube Ø A B C D Stroke F G Ø H I E Weight in kg* 13 VDCI mixproof valve dimensions

VDCI mixproof valve working conditions DN SMS DIN US Pressure drop (Kv) Pressure drop (Cv) Opening time (s) Air consumption (Nl) 38 1"1/2 44 51 2" 48 63 2"1/2 95 65 97 76 3" 0 80 170 4 0 4" 215 125 400 1 6" 465 51,04 55,68 1,2 112,52 116 197,2 249,4 464 539,4 4,2 4,2 9 9 9,8,8 17 17 2 2 5 6 6 11 11 21 21 FOR ALL DIAMETERS OF MIXPROOF VALVE Maximum temperature: Minimum temperature: Temperature difference: Maximum working pressure: Bar Maximum supply pressure: 8 Bar Vacuum resistance: 0,4 cm 3 /s Minimum supply pressure: 5 Bar Maximum sealing pressure: 12 Bar 14

VDCI mixproof valve working conditions Pressure drop VDCI valve upper line 1,6 DN 38 DN 51 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 63 DN 76 0,2 0,0 DN 0 DN 125 DN 1 0 20 30 40 60 70 80 90 0 1 120 130 140 1 160 170 180 190 200 Flow m 3 /h Pressure drop VDCI valve lower line 1,6 DN 38 DN 51 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 0,2 0,0 0 20 30 40 60 70 80 90 0 1 120 Flow m 3 /h 130 140 1 160 170 180 190 200 DN 63 DN 76 DN 0 DN 125 DN 1 15

VDCI mixproof valve working conditions Pressure drop VDCI valve upper lower line 1,6 DN 38 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 0,2 0,0 DN 0 DN 125 DN 1 0 20 30 40 60 70 80 90 0 1 120 130 140 1 160 170 180 190 200 Flow m 3 /h Pressure drop VDCI valve lower upper line 1,6 DN 38 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 0 16 0,2 0,0 0 20 30 40 60 70 80 90 0 1 Flow m 3 /h 120 130 140 1 160 170 180 190 DN 125 DN 1 200

SMS 38 51 63 76 4 VDCI mixproof valve options VDCI mixproof valve with steam bearing DN DIN US B C D E F G Ø H I 38 x 1,2 5 55 368 25 179 1"1/2 38,1 x 1,65 5 55 368 25 179 40 40 x 1 5 55 368 25 179 51 x 1,25 5 70 373 35 179 2",8 x 1,65 5 70 373 35 179 53 x 1,5 5 70 373 35 179 63,5 x 1,6 130 85 434 35 204 2"1/2 63,5 x 1,65 130 85 434 35 204 65 70 x 2 130 90 436 43 204 76 x 2 130 95 441 41 204 3" 76 x 1,65 130 95 441 41 204 80 85 x 2 155 1 491 234 4" 1,6 x 2,1 155 125 1 234 0 4 x 2 155 125 1 234 125 129 x 2 200 155 595 60 3 6" 152,4 x 2,75 200 180 615 60 3 1 154 x 2 200 180 615 60 3 Design Tube Ø A 585 128 112 585 128 112 585 128 112 620 128 120 620 128 120 620 128 120 720 167 140 720 167 140 730 167 142 745 167 145 745 167 145 845 218 166 890 218 176 890 218 176 65 270 204 1135 270 214 1135 270 214 Weight in kg* 23 23 23 23 23 23 46 46 46 46 46 83 92 92 142 152 152 * Without control unit The VDCI can be equipped with a steam or fluid circulation bearing. In this case, the actuator lantern and counterbalance cover are fitted with a circulating ring and are connected externally by an aseptic product feed pipe. Technical specifications of this valve are the same as the base model specifications. Tube Ø A B B I C Ø H F D E G (Required space for disassembly) 17

VDCI FdC tank bottom mixproof valve technical description This valve is designed to shut off the tank from the rest of the process circuit. The mixproof technology allows the pipes to be cleaned right up to the tank bottom in total safety. The air space leakage indicator warns of a possible faulty seal. Design 20 The tank bottom VDCI has similar characteristics to standard VDCI double block and bleed valves (floating seal, extra-thick body, strength, etc.), except for resistance to waterhammer. Thanks to the special shape of the plugs, a seal is formed tight up to the tank bottom. The leakage indicator is located on top of the actuator in this case. It also allows the air space to be washed by activating the lower plug (and possibly the upper plug). The tank mixproof valve is designed on the standard VDCI model. A thick weld-on lip flange holds the spherical T or L body and screwed sectors provide angular orientation of the valve ends. As the single air space crosses the entire lower plug, any flow can quickly be spotted. The break-away actuator is used to clean the air space and plug bearing surface during in-line washing operations. The design does not allow the usual units to be mounted on top of the actuator - only a lantern or stainless steel bracket-mounted detector can be fitted. The control solenoid valves are grouped together in this case. Several mixproof valves can be used on the same tank bottom panel to carry out a number of functions at the same time. This mixproof valve can also be fitted with a steam bearing to sterilise the stem.

VDCI FdC tank bottom mixproof valve technical description Fluids circulation (washing line) Valve closed Lower plug lift Open valve Washing Air Air 21

Tube Ø A 22 Ø H E Axis/line Axis/line G (Required space for disassembly) A A B B F D Partial bottom view body/flange Ø B Ø A Ø B Ø A L G L G I I K H H K Ø J I Ø E Ø D Ø C Ø F Ø F Ø E Ø D Ø C Ø J J Axis/line (s) Ø C VIEW A-A VIEW B-B B (Possible rotation line/nut) DN 51 DN 63 to 4 VDCI FdC valve VDCI FdC flange VDCI FdC tank bottom mixproof valve dimensions

SMS 51 63 76 4 SMS 51 63 76 0 2" 1/2 65 3" 80 4 4" 178,25 0,25 74 81 0,05 0,2 122 152 198,25 0,25 6 113 123,2 0,05 145 175 0,25 0,05 198,25 6 113 123,2 145 175 0,25 0,05 198,25 6 113 123,2 145 175 5 0,05 267,85 146 155,2 184,2 208 245 5 0,05 267,85 146 155,2 184,2 208 245 14 8 12 16 8 14 16 8 14 16 8 14 17 16 17 16 M M M M M12 M12 8 12 45 45 14 45 45 14 45 45 14 45 45 8,5 14 40 8,5 14 40 45 45 45 45 45 45 DN DIN US 2" Ø A Ø B Ø C Ø D Ø E Ø F G H I Ø J K L VDCI FdC flange 1,6 x 2,1 155 268 471 49 234 0 4 x 2 155 268 471 49 234 3" 80 85 x 2 155 268 461 49 234 4" 76 x 2 130 198 413 40 204 76 x 1,65 130 198 413 40 204 540 167 64 540 167 64 625 218 68 635 218 78 635 218 78 8 8 2" 1/2 65 70 x 2 130 198 408 40 204 530 167 61 8 63,5 x 1,6 130 198 406 40 204 63,5 x 1,65 130 198 406 40 204 520 167 58 520 167 58 8 8 2" 53 x 1,5 5 178 363 34 179 465 128 49 8 51 x 1,25 5 178 363 34 179,8 x 1,65 5 178 363 34 179 465 128 49 465 128 49 8 8 30 30 30 31 31 30 26 26 23 21 21 20 20 20 35 35 40 40 40 66 75 75 DN DIN US Tube Ø A B Ø C D Stroke F G Ø H I E J Weight in kg VDCI FdC valve 23 VDCI FdC tank bottom mixproof valve dimensions

VDCI FdC tank bottom mixproof valve working conditions DN SMS DIN US Pressure drop (Kv) Pressure drop (Cv) Opening time (s) Air consumption (Nl) 51 2" 48 63 2"1/2 95 65 97 76 3" 0 80 170 4 0 4" 215 55,68 1,2 112,52 116 197,2 249,4 4,2 9 9 9,8,8 2 5 6 6 11 11 FOR ALL DIAMETERS OF TANK BOTTOM MIXPROOF VALVE Maximum temperature: Minimum temperature: Temperature difference: Maximum working pressure: 4 Bar Maximum supply pressure: 8 Bar Vacuum resistance: 0,4 cm 3 /s Minimum supply pressure: 5 Bar Maximum sealing pressure: 5 Bar Pressure drop VDCI FdC valves upper line 1,6 DN 51 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 63 DN 76 24 0,2 0,0 0 20 30 40 60 70 80 90 0 1 120 Flow m 3 /h 130 140 1 160 170 180 190 200 DN 0

VDCI FdC tank bottom mixproof valve working conditions Pressure drop VDCI FdC valve upper lower line 1,6 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 0 0,2 0,0 0 20 30 40 60 70 80 90 0 1 120 130 140 1 160 170 180 190 200 Flow m 3 /h Pressure drop VDCI FdC valve lower upper line 1,6 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 0,2 0,0 0 20 30 40 60 70 80 90 0 1 120 Flow m 3 /h 130 140 1 160 170 180 190 DN 0 200 25

VDCI mixproof valve 3 bodies Design The standard VDCI mixproof valve is essentially a shut-off valve. To change the direction of flow, Definox produces a double shutoff valve with upper shut-off function being performed by a double plug. This valve directs the liquid either to the upper body or the lower body. The double seal function is provided between the upper body and the centre body. Valve closed Upper line closed Lower lines open Lower plug lift Air Washing 28

VDCI mixproof valve 3 bodies This valve retains the general characteristics of the standard mixproof valve, particularly the possibility of activating the upper shut-off plugs. The pressure holding capacity is modified. Upper plug lift Valve open Upper lines open Lower line closed Air Air Washing 29

VDCI SP mixproof valve leak free opening type Design Like the standard VDCI mixproof valve, the VDCI SP allows the two plugs to be operated independently to clean the air space and the seal bearing surfaces. The sliding seal on the bottom plug provides a total seal when the valve is operated, preventing product loss on opening. Working conditions DN SMS DIN US Pressure drop (Kv) Pressure drop (Cv) Opening time (s) Air consumption (Nl) 38 1"1/2 46 51 2" 52 63 2"1/2 2 65 4 76 3" 5 80 180 4 0 4" 230 53,36 60,32 118,32 120,64 121,8 208,8 266,8 4,2 4,2 9 9 9,8,8 2 2 5 6 6 11 11 30 FOR ALL DIAMETERS OF VDCI SP MIXPROOF VALVE Maximum temperature: Minimum temperature: Temperature difference: Maximum working pressure: Bar Maximum supply pressure: 8 Bar Vacuum resistance: 0,7 cm 3 /s Minimum supply pressure: 5 Bar Maximum sealing pressure: 12 Bar

VDCI SP mixproof valve leak free opening type Dimensions Ø H Tube Ø A F I C D E G (Required space for disassembly) B B DN SMS DIN US Tube Ø A B C D E F G Ø H I 38 38 x 1,2 5 57 314 29 179 495 128 76 1"1/2 38,1 x 1,65 5 57 314 29 179 495 128 76 40 40 x 1 5 57 314 29 179 495 128 76 51 51 x 1,25 5 70 320 38 179 525 128 82 2",8 x 1,65 5 70 320 38 179 525 128 82 53 x 1,5 5 70 320 38 179 525 128 82 63 63,5 x 1,6 130 85 359 40 204 600 167 98 2"1/2 63,5 x 1,65 130 85 359 40 204 600 167 98 65 70 x 2 130 90 362 40 204 605 167 0 76 76 x 2 130 95 365 40 204 625 167 4 3" 76 x 1,65 130 95 365 40 204 625 167 4 80 85 x 2 130 1 365 47 204 648 167 115 4" 1,6 x 2,1 155 125 416 234 7 218 127 4 0 4 x 2 155 125 416 234 7 218 127 125 129 x 2 200 155 525 76 3 925 270 167 6" 152,4 x 2,75 200 180 540 76 3 00 270 180 1 154 x 2 200 180 540 76 3 00 270 180 Weight in kg* 18 18 18 19 19 19 28 28 30 33 33 61 70 70 1 120 120 * Without control unit 31

VDCI SP mixproof valve leak free opening type Pressure drop VDCI SP valve upper line 1,6 DN 38 DN 51 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 63 DN 76 0,2 DN 0 0,0 0 20 30 40 60 70 80 90 0 1 120 130 140 1 160 170 180 190 200 Flow m 3 /h Pressure drop VDCI SP valve lower line 1,6 DN 38 DN 51 1,4 DN 63 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 76 DN 0 32 0,2 0,0 0 20 30 40 60 70 80 90 0 1 Flow m 3 /h 120 130 140 1 160 170 180 190 200

VDCI SP mixproof valve leak free opening type Pressure drop VDCI SP valve upper lower line 1,6 DN 38 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 0 0,2 0,0 0 20 30 40 60 70 80 90 0 1 120 130 140 1 160 170 180 190 200 Flow m 3 /h Pressure drop VDCI SP valve lower upper line 1,6 DN 38 DN 51 DN 63 DN 76 1,4 Pressure drop in bar 1,2 1,0 0,8 0,6 0,4 DN 0 0,2 0,0 0 20 30 40 60 70 80 90 0 1 Flow m 3 /h 120 130 140 1 160 170 180 190 200 33

VDCI PMO mixproof valve Design In order to meet the particular standards of certain organizations (the FDA, for instance), DEFINOX has produced a PMO (Pasteurised Milk Ordinance) version. It basically differs from the standard mixproof valve by a leakage section identical to the one on the process branch pipe. This requires a modification to its dimensional characteristics. Note: The standard signal-back equipment on this model may be complemented by a device to detect that the plugs are raised during air space washing operations. This valve retains the working conditions of the standard mixproof valve. 34

Standard signal back equipment suitable for VDCI - VDCI SP mixproof valves Components Model Signal back equipment & Fixing device Switch or Contact Solenoid valve Electronic Reference Characteristics Reference Characteristics Reference Characteristics Bracket M18 switch on lantern (M 12 on request) 7007906 7007911 7007949 (M12) PNP - 36 V DC 20-2 V AC/DC PNP - 36 V DC None None Classic control unit Figure 4 Ø 130 control unit H: 120 fixed on the actuator st. st. or smoked housing for switches and 1 solenoid valve. Figure 9 Ø 130 control unit H: 120 fixed on the actuator st. st. or smoked housing for switches and 1 to 3 solenoid valve(s). Classic Ø 170 control unit H: 230 fixed on control unit the actuator st. st. or smoked housing sale stopped for switches and 1 to 3 solenoid valve(s). DN 130 control unit AS-i link Figure 8 Ø 130 control unit H: 1 fixed on the actuator st. st. or smoked housing for switches, 1 solenoid valve and AS-I module Figure Ø130 control unit H: 1 fixed on the actuator st. st. or smoked housing for switches, 2 to 3 solenoid valves & AS- i module 7007922 7007930 7007991 7007922 7007930 7007922 7007930 7008045 7008045 PNP - 36 V DC 20-2 V AC/DC NAMUR PNP - 36 V DC 20-2 V AC/DC PNP - 36 V DC 20-2 V AC/DC Prismatic switch Prismatic switch - 36 V DC 7007943 7007944 7007947 7007948 7009018 7009020 7009023 7009024 7007952 7007953 7007958 7008969 7008919 784 7007952 7009018 7009020 24 V AC/DC 2,5 W 48 V AC/DC 2,5 W 1 V AC 2,5 VA 220 V AC 2,5 VA 24 V DC* 24 V DC 48 V AC 1 V AC Pneumatic interface 24 V DC 24 V AC 48 V AC 1 V AC Pilot & Interface 24 V DC* 24 V DC 7707999 70015 7708001 70015 None None None AS-i module with link cable and vampire connector AS-i module with link cable and vampire connector * Lockable (main actuator) 36 1 or 2 switch(es) assembled as well as 2 to 3 solenoid valve(s) 1 or 2 switch(es) assembled and 1 solenoid valve 1 or 2 switch(es) assembled as well as 1 to 3 pneumatic modules 1 or 2 switch(es) assembled as well as 1 to 3 solenoid valve(s) 1 or 2 switch(es) assembled as well as 1 solenoid valve 3/2 1 or 2 switch(es) assembled Moulded cable: Lg 6 m Remarks

Ø 130 standard control unit smoked housing Ø 130 standard control unit st. st. housing M8 85 90 M8 85 90 115 115 15 Ø 130 Ø 130 Fig. 4: Ø 130 control unit Fig. 8: Ø 130 control unit Fig. 9: Ø 130 control unit Photos and drawings of the figures mentioned on the data sheet Standard signal back equipment suitable for VDCI - VDCI SP mixproof valves Fig. : Ø 130 control unit 37

Standard signal back equipment suitable for VDCI FdC tank bottom mixproof valves Photos and drawings of the figures mentioned on the data sheet Classic control box AS-i link Model Signal back equipment & Fixing device Switch or Contact Solenoid valve Electronic Classic control unit AS-i link M18 switch on lantern (M 12 on request) Solenoid valve in a separate plastic or stainless steel box M18 switch on lantern (M 12 on request) Solenoid valve in a separate plastic or stainless steel box Components Reference Characteristics Reference Characteristics Reference Characteristics 7007906 7007911 7007949 (M12) 7007906 7007949 (M12) PNP - 36 V DC 20-2 V AC/DC PNP - 36 V DC PNP - 36 V DC PNP - 36 V DC 7007952 7007953 7007958 7008969 7008919 7008094 7008095 Pneumatic interface 24 V DC 24 V AC 48 V AC 1 V AC AS-i airbox Base for AS-i module None AS-i module with gland for AS-i cable 38 Cabinet on wall or fixed onto the valve, 1 or 3 solenoid valves assembled. Pneumatic links between actuators and cabinet Cabinet on wall or fixed onto the valve, 1 or 2 switch(es) assembled, as well as 1 to 3 pneumatic modules Remarks

VDCI mixproof valve signal back equipment The choice of signal back equipment depends on the functions to be performed. Remarks regarding the standard signal back equipment 1 - On request, we can fit Eex microcontacts or Namur pneumatic switches in control units for explosive environments. 2 - Specific detection devices can be studied (lantern detection). 3 - The supply of a control unit includes the entry gland, wiring to the electric components terminal strip and the 4/6 or 6/8 (DN 80 to DN 1) pneumatic hose from the unit to the actuator. 4 - Standard signal-back equipment can also be complemented by the following accessories: rapid air release stainless steel or semi-rigid wiring stainless steel air connection etc Note : The VDCI leak free opening type and the VDCI 3 bodies are like the standard one. AS-i network The AS-i network provides a reliable, cost-effective valve networking solution. An AS-i module installed in each of the signal back units allows the control of all pneumatic functions on DEFINOX valves (valve opening and closing, stroke of the plugs ) and read the information sent by the opening and closing sensors, via the AS-i network. Advantages of the AS-i network Open standard. Quick and easy to install and put into operation. Quick to wire up due to the use of vampire connectors and a non-shielded two-core cable. Free topology. Several AS-i masters available (PLC couplers or Profibus-DP, Device-Net, Interbus-S, WorldFip, Modbus, Modbus-Plus or other gateways). Max. 62 nodes on AS-i network distributed over 0 m of cable (300 m with repeaters). Cycle time : approx. 5ms for 31 nodes and ms for 62 nodes. Transmission error control mechanisms. Extension possibilities. 39