COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

Similar documents
Effective June 2016 New Issue

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

Effective November 2016 Supersedes September 1998 (S )

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

Effective March 2015 Supersedes S August 2012

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Effective May 2017 Supersedes January 2003 (S )

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

Effective May 2017 Supersedes December 2004 (S )

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

S Voltage Regulators. Contents. QD3 Quik-Drive Voltage Regulator Tap-Changer Manual. Figure 1B. QD3 Tap-changer. Figure 1A. QD3 Tap-changer.

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

3-way multi-family drawout cable interlock kit - type 32 - RF

Two-way cable interlock kit for Magnum fixed circuit breakers

Factory Authorized Mechanism Enhancement (FAME)

CCP2-FLR1-21_ flange-rod operating mechanism

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Two-way cable interlock kit for Magnum drawout circuit breakers

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

Instruction Booklet IB E. Contents

Effective October 2016 Supersedes January 2014 (S )

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

Installation Instructions For Motor Control Center (MCC) Units

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

O & M Manual for the EATON Generator Ready Loadcenter

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

CM52 Network Protector with Arc Flash Reduction Module

KFE10010-E. Reclosers. Contents. Type KFVE and KFVME (27kV) Bus Bar Kit KRK710-1 Installation Instructions. Cooper Power Systems

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

Vacuum Circuit Breaker (Vehicle)

ELB ELB

DAP-625S and DAP-875S

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

FCB-450, LCB-600, MCB-800

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Single Post Caliper Brake VC500

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Type DTU De-energized Tap Changer Application, Installation & Selection Guide. IL A Instruction Leaflet Page 1 September, 2003

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Installation and Operation

100 A externally operated one-, twoand three-phase tap-changer switch

AIR CHAMP PRODUCTS. BD Caliper Brake STANDARD FORM NO. L Y MTY (81) QRO (442)

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

LINEAR MOTION CONTROL

Magnum Breaker Remote Racking Device (MRR1000)

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Ford Mustang 2013 GT500 Rear Break Install Guide for Mustang GT

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

Straight-Bore Clutch LSCC-32, 44, 54

Transcription:

Voltage Regulators MN225025EN Effective March 2016 Supersedes S225-50-48 November 2008 COOPER POWER SERIES QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit 5791646A26 installation instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or otherwise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016

Contents SAFETY INFORMATION Safety information...iv PRODUCT INFORMATION Introduction...1 Parts supplies...1 Tools required...1 Acceptance and initial inspection...1 Handling and storage...1 Standards...1 INSTALLATION PROCEDURE Removing existing contact assembly....2 Installing replacement contact and reassembly....4 Placing tap-changer into neutral...7 QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016 iii

! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally approved safety procedures and safety instructions when working around high voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around highand low-voltage lines and equipment. G103.3 WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage. G101.0 WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. G102.1 WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.3 iv QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016

Product information Introduction Service Information MN225025EN provides the instructions for replacing Eaton's Cooper Power series QD5 Quik- Drive tap-changer reversing neutral stationary contact on Eaton's Cooper Power series 32-step voltage regulator. For normal maintenance, the contact is replaced before critical contact erosion has occurred. Refer to Service Information MN225003EN CL-7 Series Control Installation, Operation, and Maintenance Instructions for information on the CL-6 voltage regulator control. Refer to Service Information MN225016EN CL-6 Series Control Installation, Operation, and Maintenance Instructions for information on the CL-6 voltage regulator control. Refer to Service Information MN225008EN VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions for information on Eaton's voltage regulator with Quik-Drive tap-changer. Parts supplied Item Part Number Description Qty 1 0791646A26 1 Tools required Ratchet Wrench 3/8 inch Socket 7/16 inch Socket 9/16 inch Deep-well Socket Torque Wrench, in-lbs Small flat-blade Screwdriver or 5/32 inch Allen Wrench 8" Long flat-blade Screwdriver Loctite 243 Threadlocker Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Read and understand the manuals detailing the installation and operation of the regulator and the regulator control used with the regulator. Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. For additional information, please contact your Eaton representative. Acceptance and initial inspection This kit is thoroughly inspected at the factory. It is in good condition when accepted by the carrier for shipment. Upon receipt of the regulator kit, a thorough inspection should be made for damage, evidence of rough handling, or shortages. Should this initial inspection reveal evidence of rough handling, damage, or shortages, file a claim with the carrier immediately. Also, notify your Eaton representative. Figure 1. neutral stationary contact. Handling and storage Be careful during handing and storage of the kit to minimize the possibility of damage. If the regulator kit is not to be placed into immediate use, store the kit in a clean, dry location. Quality standards ISO 9001 Certified Quality Management System QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016 1

Installation procedure Removing existing contact assembly NNote: Retain all hardware. 1. Hold the reversing movable contact assembly to prevent it from moving. Using a 9/16" wrench, loosen and remove the reversing actuator arm nut. See Figure 2. 3. Using a 7/16" wrench, loosen and remove both bushingmounting bolts. See Figure 4. Actuator Arm Bushing Mounting Bolt Segment Actuator Arm Bushing Assembly Figure 4. actuator arm removed. Figure 2. actuator arm nut removal. Actuator Arm Nut 4. Remove the bushing from the reversing actuator shaft. See Figure 5. 2. Lift outward on the reversing actuator arm and remove it from the reversing movable contact bushing. The reversing actuator shaft may be tapped in to allow clearance to remove the arm. See Figures 3 and 4. Tap-Changer Plate Actuator Shaft Bushing Figure 5. Removing reversing movable contact bushing. Actuator Arm Figure 3. actuator arm removal. 2 QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016

5. Using a small screwdriver (or 5/32" Allen wrench) and a 1/4" wrench, loosen and remove the self-locking nuts and reversing logic switch mounting screws. See Figures 6 and 7. 6. After the removal of the reversing logic switch mounting screws, the switch will drop away from the reversing movable switch tube. See Figure 8. Logic Tube Logic Switch Mounting Hardware Figure 6. Logic switch removal. Logic Switch Figure 8. movable contact switch. 7. Using a 9/16" wrench, loosen and remove the nuts and flat washers from both of the reversing neutral stationary contacts on the back of the tap-changer contact panel. See Figure 9. Logic Switch Hardware Figure 7. logic switch removal. Figure 9. neutral stationary contact hardware. QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016 3

8. Pull the reversing movable contact assembly and the reversing neutral stationary contact forward toward the steel front panel as far as possible. See Figure 10. Installing replacement contact and reassembly 1. Place a new reversing neutral stationary contact into the mounting holes in the contact panel. Place the contact assembly so that it is in the board but far enough out so that engagement can be made when installing the reversing movable contact assembly. See Figure 12. Figure 10. Removing movable contact assembly. 9. Rotate the reversing movable contact counter clockwise until the movable contact assemble disengages from the reversing neutral stationary contact and remove it from the tap-changer. See Figure 11. Figure 12. Replacing reversing neutral stationary contact. 2. Insert a standard flat screwdriver between the middle and top button contacts on the reversing movable contact assembly and twist to separate. Line up the movable and stationary contacts and rotate the movable contact assembly clockwise over the reversing stationary contact. See Figure 13. Stationery Button Removing Assembly Figure 11. Removing reversing movable contact. Slot 10. Remove the reversing neutral stationary contact assembly from the tap-changer contact panel. Figure 13. Reassembly of neutral stationary and reversing movable. 4 QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016

3. Continue to reposition the screwdriver, separate the button contacts and rotate the reversing movable contact assembly until the middle button contact is fully engaged in the center of the reversing stationary contact blade. See Figure 14. 5. Place a flat washer and nut over each of the reversing neutral stationary contact studs. Tighten to a torque of 80 90 in-lbs (9.0 10.2 Nm). See Figure 16. Studs Figure 14. Reassembly. Figure 16. neutral stationary contact fastening. 4. Slide the stationary and movable contact assembly toward the contact panel. Align the movable contact assembly so that the reversing movable contact tube aligns and goes through the hole in the contact panel. At this point, the stationary contact and movable contact should be fully engaged with the contact panel. See Figure 15. 6. Place the mounting hardware onto the reversing logic switches and fasten to the tap-changer front plate. While holding a small screwdriver, tighten the nuts to a torque of 4 5 in-lbs (0.5 0.6 Nm). See Figure 17. 4-40 Hex Nut Panel Tube 4-40x1.25 Screws Logic Switches Figure 15. and movable contact alignment. Figure 17. logic switch mounting. QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016 5

7. If not present on the threads, apply Loctite 243 Threadlocker to the two 1/4-28 bolts. Using the bolts and a 7/16" wrench, fasten the reversing movable bushing to the front of the tap-changer. Tighten the bolts to a torque of 30 40 in-lbs (3.4 4.5 Nm). See Figure 18. 1/4-28 Bolts Screwdriver or Shaft Rod Segment Shaft Figure 20. Pushing the reversing segment shaft forward. Figure 18. segment gear shaft. 8. Place the reversing segment arm onto the reversing actuator shaft. Align the square portion of the shaft with the square hole in the arm. If needed, place a screwdriver through the movable contact tube and push the shaft forward while seating the arm over the shaft. It may be necessary to rotate the movable contact assembly slightly to align the shaft and hole. See Figures 19 and 20.Place the self-locking nut onto the reversing segment shaft. Using a 9/16" wrench, tighten to a torque of 180 192 in-lbs (20.3 21.7 Nm) while holding the movable contact assembly to prevent turning. See Figure 21. 3/8-16 Self- Locking Nut Segment Shaft Segment Arm Figure 21. segment fastening. 9. Once the work has been completed, place the tapchanger in the neutral position. Segment Gear Shaft Figure 19. Placement of reversing segment arm. 6 QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016

Placing tap-changer into neutral 1. Place a 3/8" socket and ratchet on the output shaft of the motor; rotate the motor so that the contacts and other components are aligned in the neutral position 2. Confirm that the regulator is in the neutral position. A. Main movable contacts are located on the neutral stationary contact, which is located at the 11 o clock position and under the reversing switch movable contact assembly. See Figure 22. C. The pinion cam is pointing to the right over the holding switch actuator. See Figure 24. Holding Switch Actuator Pinion Cam Figure 24. position for position indicator pinion cam and holding switch. Main Figure 22. position for main movable contacts. B. The reversing movable contact is located on the reversing neutral stationary contact. See Figure 23. Figure 23. position for reversing movable. QD5 REVERSING NEUTRAL STATIONARY CONTACT ASSEMBLY KIT INSTRUCTIONS MN225025EN March 2016 7

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2016 Eaton All Rights Reserved Printed in USA Publication No. MN225025EN March 2016 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton's Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.