C E R T I F I C A T E O F C O M P L I A N C E

Similar documents
Certificate of Compliance

File E31519 Project 10CA February 4, 2011 REPORT MAGNETIC MOTOR CONTROLLERS. Siemens AG Amberg, Germany

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

C E R T I F I C A T E O F C O M P L I A N C E

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

E44653 SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

File E14900 Project 98NK January 11, 1999 REPORT MOTOR CONTROLLERS MAGNETIC. Siemens Energy & Automation Inc. Batavia, IL

C E R T I F I C A T E O F C O M P L I A N C E

Certi cation Record INDUSTRIAL CONTROL EQUIPMENT Motor Controllers Magnetic

Certificate of Compliance

Certificate of Compliance

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

Certificate of Compliance

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

Product Specification Sheet #3LD2.1

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

A302DN.40/.63A Thermal Current Motor Starter

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

XT IEC Power Control Manual Motor Protectors

Protectors. Manual motor. Types MS116, MS132, MS45x, MS49x. MS Series. Manual motor protectors. Type MS116. Type MS132. Type MS45x.

Selection Guide Motor Control Device Solutions

AF series contactors (9 2650)

s A Confirmation Bestätigung

Switches Unlimited Phone: * Fax:

AF series contactors (9 2650)

Page 2-4 Page 2-8. Page Page 2-13

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Table of Contents. HCC Contactor Nomenclature

Type Approval Certificate

Manual Motor Starters. Meta-MEC

Sicherungslose Verbraucherabzweige Leistungsschalter 3VA. fuseless load feeder circuit breaker

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Low-Peak 600V Class RK1

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Poles 3 Starter Size NEMA 3 NON ALUMINUM LINE TERMINAL, LOAD TERMINAL

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Self-protected Combination Starters System PKZ 2-SP

4.1. Definite Purpose Contactors and Starters. Contents

Certi 堵脝 cation Record

Overload Relay Heater Tables

24.4. Miniature Circuit Breakers and Supplementary Protectors. For Immediate Delivery or Tech Support call KMParts.com at (866)

CI-TI Contactors and motor starters Types CI 61 - CI 98

Enclosed Rotary Switch Product Specification Sheets Table of Contents

Prüf-Nr./Q-Nr. Certificate No. Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: -Daten: U",", / U = 690V / U *o = 6kV Hersteller:

4.4. Definite Purpose Contactors and Starters A Starters A27, B27. NEMA Type 1 Enclosed Control

Short-Circuit Current Ratings

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Devices for Branch Circuits and Feeders

Prüf-Nr./Q-Nr.: Certificate No.: Dienststelle: Department: Ort: PIace: Anlagen: Enclosures: rech. Daten: Specification: U = 500V, U" = 400V l"= 12 A

Types of Motor Starters There are several types of motor starters. However, the two most basic types of these electrical devices are:

Low Voltage Fuses For Motor Protection

Bulletin 194R Next Generation Global Fused and Non-Fused Disconnects

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Motor Starter Protectors

ECET 211 Electric Machines & Controls Lecture 8 Motor Control Circuits (1 of 2) Lecture 8 Motor Control Circuits

Motor Starter Protectors

NEMA Contactors & Starters (Freedom)

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Protection Equipment. 5/2 Introduction

Bulletin 190-M Compact Starters. Selection Guide

General Purpose US Fuses

IEC Power Control SIRIUS. Motor Starter Protectors. Revised 04/20/15. Section Overview... 1/2-1/3. Motor Starter Protectors

UL/CSA Non-fused Disconnect Switches

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

SPEEDFAX TM 2011 Disconnect Switches Contents

For 200V 3 Phase Motors 185. For 240V 3 Phase Motors 187. For 480Y/277V 3 Phase Motors 189. For 600Y/347V 3 Phase Motors 191. UL Listed CSA Certified

US Catalog January Motor protection and control Manual motor starters, contactors and overload relays

3 Pole, 27 Amp, Non-Reversing Across The Line Contactor With V Ac Coil and 1 No Auxiliary Contact

Technical Information

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Presented to the IAPMO Standards Review Committee on December 9, 2013

KT4 Manual Motor Starter

Application Description

Protection Equipment. Overload Relays. Reference Manual 04/2011. Industrial Controls. Answers for industry.

Description. Positive safety relays

KT7. Methods. of Applying. & Molded Case Circuit Breakers F119. Motor Circuit Controllers

Selection Guide. Control Circuit and Load Protection

SECTION MOTOR CONTROL

and Refrigeration Institute). CNX Special Purpose Contactors

3. Coils shall be of molded construction

Instructions for Type W Three Phase, Standalone Overload Relays, Size 1 through 6

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

4 - Miniature controls

SD Series Non-Fused Load Switches

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Enclosed Full-Voltage Starters

300% Motor full load amps at 80 seconds, 400% Motor full load amps at 35 seconds

Technical data OT16E3 OT160E3 UL & CSA

Transcription:

Issued to: SIEMENS AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE 48 92220 AMBERG, GERMANY This is to certify that representative samples of Motor Controllers, Magnetic USL, CNL - Type No 3RT10, 3RT11, 3RT13, 3RT15 or 3RT16 followed by 33, 34, 35 or 36 followed by -1 or -3 followed by A, B, C, D, E, F, H, J, K, M, P, Q, R, S or X followed by a character and a number followed by 0, 1, 2, 3, 4, 5, 6, 8 or 9, may be followed by -0LA2, -0GA0, -1LA2, -4 or any Suffix Letters and/or numbers. (See Following Page For Additional Model Information.) Have been investigated by UL in accordance with the Standard(s) indicated on this Certificate. Standard(s) for Safety: Additional Information: ANSI/UL 508, "Industrial Control Equipment" and CSA-C22.2 No. 14, "Industrial Control Equipment." See the UL Online Certifications Directory at www.ul.com/database for additional information Only those products bearing the UL Certification Mark should be considered as being covered by UL's Certification and Follow-Up Service. Look for the UL Certification Mark on the product. Page 1 of 10

This is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements. Additional Model Information: General: These devices are open types 3 or 4 pole contactors for use in industrial applications. Type 3RT1133 and 3RT1135 have additionally been evaluated to IEC 60947-6, weld-free. These devices are intended to be used in combination with certified overload relays type 3RU. or 3RB. Ratings: Horsepower 3RT1033 Voltage 1-ph 3-ph FLA LRA 115 V 2 -- 24 A -- 200/208 V 3 7.5 25.3 A 210.5 A 230/240 V 5 10 28 A 225 A 460/480 V -- 20 27 A 225 A 575/600 V -- 25 27 A 225 A Horsepower 3RT1034 Voltage 1-ph 3-ph FLA LRA 115 V 2 hp -- 24 A -- 200/208 V 5 hp 10 hp 32.2 A 259 A 230/240 V 5 hp 10 hp 28 A 225 A 460/480 V -- 25 hp 34 A 281 A 575/600 V -- 30 hp 32 A 270 A Horsepower 3RT1035 Voltage 1-ph 3-ph FLA LRA 115 V 3 hp -- 34 A -- 200/208 V 5 hp 10 hp 32.2 A 259 A 230/240 V 7 1/2 hp 15 hp 42 A 337 A 460/480 V -- 30 hp 40 A 337 A 575/600 V -- 40 hp 41 A 330 A Page 2 of 10

Horsepower 3RT1036 Voltage 1-ph 3-ph FLA LRA 115 V 3 hp -- 32 A -- 200/208 V 7 1/2 hp 15 hp 48.3 A 388 A 230/240 V 10 hp 15 hp 42 A 337 A 460/480 V -- 40 hp 52 A 412 A 575/600 V -- 50 hp 52 A 412 A Horsepower 3RT1033 or 3RT1034 (Elevator Control) Voltage 1ph,1 pole 2ph, 2pole 3-ph FLA LRA 120 V 1 1/2 hp 1 1/2 hp - 22 A 183 A 230/240 V 3 hp 3 hp 7 1/2hp 22 A 183 A 460/480 V - - 15 hp 21 A 169 A 575/600 V - - 20 hp 22 A 180 A Horsepower 3RT1035 (Elevator Control) Voltage 1 ph, 1 pole 1 ph, 2 pole 3-ph FLA LRA 120 V 2 hp 2 hp - 28 A 225 A 230/240 V 3 hp 5 hp 10 hp 28 A 225 A 460/480 V - - 20 hp 27 A 225 A 575/600 V - - 25 hp 27 A 225 A Horsepower 3RT1036 (Elevator Control) Voltage 1 ph, 1 pole 2 ph, 2 pole 3-ph FLA LRA 120 V 3 hp 3 hp - 33.6 A 270 A 230/240 V 5 hp 5 hp 12 hp 33.6 A 270 A 460/480 V - - 25 hp 34 A 281 A 575/600 V - - 30 hp 32 A 270 A Horsepower 3RT1133 (Weld-Free according to IEC 60947-6 Standard) Voltage 3-ph FLA LRA 200/208 V 7.5 hp 25.3 A 210.5 A 230/240 V 7.5 hp 22 A 183 A 460/480 V 15 hp 21 A 169 A Page 3 of 10

Horsepower 3RT1135 (Weld-Free according to IEC 60947-6 Standard) Voltage 3-ph FLA LRA 200/208 V 10 hp 32.2 A 259 A 230/240 V 10 hp 28 A 225 A 460/480 V 25 h 34 A 281 A Horsepower 3RT1336 (4 NO Main Contacts) Voltage 3-ph FLA LRA 200/208 V 5 hp 17.5 A 140 A 230/240 V 7.5 hp 22 A 183 A 460/480 V 15 hp 21 A 169 A Horsepower 3RT1535 (2 NO + 2 NC Main Contacts) Voltage 3-ph FLA LRA 200/208 V 10 hp 32.2 A 259 A 230/240 V 15 hp 42 A 337 A 460/480 V 25 hp 34 A 281 A Capacitive Switching 3RT1636 Voltage 1-ph 3-ph Current 200/208 V 7.5 kvar 13 kvar 36 A 230/240 V 8.5 kvar 15 kvar 36 A 460/480 V 17 kvar 30 kvar 36 A 575/600 V 21 kvar 37 kvar 36 A Horsepower 3RT1336-1AP00-4AA0 Voltage 1-ph 3-ph FLA LRA 115 V 3 hp -- 34 A -- 200/208 V 5 hp 10 hp 32.2 A 186.3 A 230/240 V 5 hp 10 hp 28 A 162 A 460/480 V -- 25 hp 34 A 183 A 575/600 V -- 30 hp 32 A 174 A Main contacts: General Use Rating - type 3RT1033, 600 V AC, 45 A - type 3RT1034, 600 V AC, 45 A - type 3RT1035, 600 V AC, 55 A - type 3RT1036, 600 V AC, 50 A - type 3RT1336-1AP00-4AA0, 600 V AC, 35 A Page 4 of 10

Auxiliary contacts: 1-, 2- or 4-pole auxiliary contact blocks Type 3RH1921 are top or side mounted, for ratings refer to File E44653 Vol. 11, Sec. 2 or Vol. 12 Sec. 3. The auxiliary contact blocks are available as factory assembled (removable or not removable design) or available as separate devices for individual arrangements. Coil Ratings: 24 through 600 V ac 12 through 250 V dc Definite Purpose: Electric Heating, 600 V ac, 250,000 c. - type 3RT1033 45 A - type 3RT1034 45 A - type 3RT1035 55 A - type 3RT1036 50 A Air conditioning, 600 V, 30,000 cycles - type 3RT1033 34 A FLA - type 3RT1034 34 A FLA - type 3RT1035 52 A FLA - type 3RT1036 52 A FLA AC Resistance: - type 3RT1336 600 V, 60 A - type 3RT1535 600 V, 55 A - types 3RT1035, 3RT1036, 60 A, 250,000 cycles at 600 V 1 pole / 1 phase, 600 V 2 poles / 1 phase or 600 V 3 poles / 3 phases (min. enclosure size 14 inches by 8 inches by 7 inches) AC Resistance Air Heating: - types 3RT1035, 3RT1036, 60 A, 250,000 cycles at 600 V 1 pole / 1 phase, 600 V 2 poles / 1 phase or 600 V 3 poles / 3 phases (min enclosure size 14 inches by 8 inches by 7 inches) AC Incandescent Lamps (AC Tungsten): - types 3RT1035, 3RT1036 60 A at 277 V 1 pole / 1 phase, 480 V 2 poles / 1 phase or 480 V 3 poles / 3 phases (min. enclosure size 14 inches by 8 inches by 7 inches) Page 5 of 10

AC Electrical Discharge Lamps (AC Standard Ballast): - types 3RT1035, 3RT1036 60 A at 600 V 1 pole / 1 phase, 600 V 2 poles / 1 phase or 600 V 3 poles / 3 phases (min enclosure size 14 inches by 8 inches by 7 inches) NEMA Ratings: 3RT1036 meets ratings for NEMA Size 2 Contactors Short Circuit Ratings: Type No. Fuse /Class Circuit Breaker Short Voltage K5, RK5, RK1, J Bkr TM 1 Bkr I 2 Circuit 3RT1033 max 125 A max 125 A max 10 A 5 ka 600 V 3RT1034 max 125 A max 125 A max 50 A 5 ka 600 V 3RT1035/3RT1535 max 150 A max 150 A max 50 A 5 ka 600 V 3RT1036 max 200 A max 200 A max 100 A 5 ka 600 V 3RT1133/3RT1135 max 125 A - - 5 ka 480 V 3RT1336 (except max 200 A max 200 A max 100 A 5 ka 600 V 3RT1336-1AP00-4AA0) 3RT1336-1AP00-4AA0 max 150 A - - 5 ka 600 V 3RT1636 max 125 A - - 10 ka 600 V 1 Note: UL Listed inverse time circuit breakers 2 Note: UL Recognized instantaneous trip circuit breakers manufactured by Siemens, Type ED63A... Page 6 of 10

High Capacity Short Circuit Ratings: Type No. Fuse Rating CB Rating 3RV103 / Size S2 3 Class Class J Bkr TM Bkr I Size RK5, [A] K5, RK1 Short Circuit Current Voltage 3RT1033 60A 125A - - - 100kA 600 - - 60-25A 25kA 600 - - 60-25A 65kA 480 3RT1034 60A 125ª - - - 100kA 600 - - 60-32A 25kA 600 - - 60-32A 65kA 480 3RT1035 80A 150A - - - 100kA 600 - - 80-40A 25kA 600 - - 80-40A 65kA 480 3RT1036 100A 200A - - - 100kA 600 - - 125-50A 25kA 600 - - 125-50A 65kA 480 Type No. 3RV202 / Size S0 3 Size [A] Short Circuit Current Voltage 3RT1035 40A 12kA 480 3RT1036 40A 12kA 480 *3 Note: For Siemens UL Listed Combination Motor Controller Type 3RV103 (Size S2) or 3RV202 (Size S0) covered in File E156943. These ratings are also applicable for short circuit ratings in group installations for Contactor 3RT103 in combination with Manual Motor Controller 3RV1.3 or 3RV2.2 covered in File E47705. The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-53 and the application. The following devices are permitted: Fuses: Classes RK1, RK5, J, G, T, CC or Circuit Breakers: Listed Siemens type, with a marked short-circuit rating equal or larger than the available short-circuit current rating. These devices were tested for group installation use at the above levels without any upstream branch circuit device. Page 7 of 10

High Capacity Short Circuit Ratings for Starters (Contactors plus Overload Relays) Type No. Fuse Circuit Breaker Class K5, Class J RK5, RK1 Bkr TM 1 Bkr I Short Circuit Voltage 3RT1033 + 3RU1136 - - 60 A - 65 ka 480 V 3RT1034 + 3RU1136 - - 60 A - 65 ka 480 V 3RT1036 + 3RU1136 - - 125 A - 65 ka 480 V 3RT1036 + 3RB2.3 - - 125 A - 65 ka 480 V 3RT1036 + 3RB2.3 100 A 200 A - - 100 ka 600 V 3RT1036 + 3RU1136 200 A 200 A - - 100 ka 600 V 1 Listed Siemens NGG3B, NEG3B or HEG3B circuit breakers. Circuit breaker catalog number will have a suffix indicating ampere rating (e.g., NGG3B050L indicates a 50 amp circuit breaker) Short Circuit Rating for Contactor, Fuse, Overload Relay combination according To UL 60947-4-1, for type 2 co-ordination. Contactor Overload Relay Fuse Class LPJ [A] Voltage for High Fault Current High Fault Current [ka] according to UL60947-4-1 Standard Fault Current [ka] according to UL60947-4-1 at 600V 3RT1033 3RU1136-4E 60 600 100 5 3RT1034 3RU1136-4F 60 600 100 5 3RT1035 3RU1136-4G 70 600 100 5 Page 8 of 10

NOMENCLATURE BREAKDOWN 3RT10 34-1 A.. 0 -... I II III IV V VI VII I. Basic Type 3RT10-3 main contacts + 1 to 8 auxiliary contacts 3RT11-3 main contacts + 1 to 4 auxiliary contacts top mounted investigated to IEC 60947-6 Standard for weld-free 3RT13-4 NO main contacts + 1 to 4 auxiliary contacts 3RT15-2 NO + 2 NC main contacts + 1 to 4 auxiliary contacts 3RT16-3 main contacts + 1 to 5 auxiliary contacts, Capacitive Switching. II. III. IV. Size S2 33 - rated for 600 V/25 hp/3 ph 34 - rated for 600 V/30 hp/3 ph 35 - rated for 600 V/40 hp/3 ph 36 - rated for 600 V/50 hp/3 ph Type of Terminals -1 - Screw Terminal -3 - Cage Clamp for the terminals of the control circuits Operating system A - AC operating system B, H, M - DC operating system C - AC operating system with EMC protective unit type 3RT1926 - varistor D, K - DC operating system with EMC protective unit type 3RT1926 - varistor E - AC operating system with EMC protective unit type 3RT1926 - RC element F, J, Q, R - DC operating system with EMC protective unit type 3RT1926 - diode combination P - AC operating system with integrated EMC protective unit Zenerdiode S DC operating system with integrated Diode combination X commercial variations Page 9 of 10

V. Operating voltage.. 24 V through 600 V ac or 12 through 250 V dc VI. VII. Auxiliary Contact Arrangements 0 - non auxiliary contact 1-1 normally open 2-1 normally closed 3-1 normally open and 1 normally closed top mounted 4-2 normally open and 2 normally closed top mounted 5-1 normally open and 1 normally closed side mounted 6-2 normally open and 2 normally closed side mounted 8 - manufacturer s identification 9 - customer s identification... - Suffix Letters and/or numbers specifies commercial variations. -0LA2, 1LA2 - with coil control unit 5070240, covered under E44653, Vol. 11, Sec. 12-0GA0 - with coil control unit 5070220, covered under E44653, Vol. 11, Sec. 12-4 - 3RT133 with higher horsepower ratings.. - any other commercial variation Page 10 of 10