Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Similar documents
Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting

Flow controller with integrated control valve (PN 16) AVQM - return and flow mounting

Flow controller (PN 25) AVQ - return and flow mounting

Pressure relief controller AVA (PN 25)

Flow controller with integrated control valve (PN 16) AHQM - return and flow mounting

Pressure reduction controllers (PN 25) AVDS - for steam AVD - for water

Flow controller (PN 25) AVQ - return and flow mounting

Differential pressure controller with flow limitation and with integrated control valve (PN 16) AHPBM-F flow mounting, fixed setting

AVQMT. AVQT controller can be combined with AVT or STM thermostatic actuators.

Flow controller with integrated control valve (PN 16) AHQM return and flow mounting

Pressure relief controller AFA / VFG 2(1) (PN 16, 25, 40)

Temperature controller AVT with safety temperature monitor STM/VG(F) (PN25)

2 - way valve (NO), pressure relieved (PN 25) VG - external thread VGF - flange

Differential pressure controller (PN 16, 25, 40) AFP(-9) / VFG 2(1) return and flow mounting, adjustable setting

k VS DN (mm) Connections ( C) (m 3 /h)

Temperature controller for heating (PN 25) AVT / VG - external thread AVT / VGF - flange

Temperature controller (PN 25) AVT / VG - external thread AVT / VGF - flange

Differential pressure relief controller (PN 16, 25, 40) AFPA / VFG 2(1)

Flow controller (PN 16, 25, 40) AFQ / VFQ 2(1) - return and flow mounting

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Flow-compensated temperature controller AVTQ DN 15

Temperature controller AVT with safety temperature monitor STM / VGS for steam (PN 25)

Pressure relief controller for oil V22D28 (PN 16, 25)

Two- and three way valves VFG.. / VFGS 2 / VFU.. for self-acting thermostats and electrical actuators

Seated valves (PN 16) VRB 2 2-way valve, internal and external thread VRB 3 3-way valve, internal and external thread

Differential pressure controller AFP / VFG 2 (VFG 21)

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Pressure reduction controller AFD / VFG 2, VFG 21, VFGS 2

Differential pressure relief controller AFPA / VFG 2 (VFG 21)

Seated valves (PN 6) VL 2 2-way valve, flange VL 3 3-way valve, flange

Differential pressure controller AFP / VFG 2 (VFG 21)

Combined automatic balancing valve AB-PM valve DN 10-32, PN 16

Flow Control and Differential Pressure Controller AFPQ / VFQ 2(21) - Installation in return line AFPQ 4 / VFQ 2(21) - Installation in flow line

Differential pressure controller AFP / VFG 2 (VFG 21)

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

Automatic balancing valves ASV-PV DN (3rd gen.)

Butterfly valve with electrical actuator VFY-WA

Butterfly valve with electrical actuator VFY-WA

Seated valves (PN 16) VF 2-2-way valve, flange VF 3-3-way valve, flange

ON/OFF zone valves AMZ 112, AMZ 113

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Your Personal Catalog Temperature Controllers All our know-how - is now yours

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Seated valves (PN 16) VRG 2 2-way valve, external thread VRG 3 3-way valve, external thread

Assisted lift operated 2/2-way solenoid valves Type EV251B

Manual presetting valves LENO MSV-BD

Combined automatic balancing valve AB-PM valve DN 15-25, PN 16

Pre-Fabricated Flushing Bypass Assembly for Plant Applications Hero Plant DN15-150

Pressure Independent Control Valve AB QM, ½ thru 2 2½ thru 4 5 thru 10 Valve Size

ChangeOver6 and NovoCon ChangeOver6 - Motorized 6-port Ball Valves

Valve bodies type RA-N with integrated presetting

Pressure independent balancing and control valve

Seated valves VF 2, VL 2-2-way VF 3, VL 3-3-way

3 & 4-Way Rotary Valves

High Capacity Valve Body, Type RA-G

Steel butterfly valves SBFV (PN 16/25)

Combined Self-operated Regulators Regulators for Differential Pressure, Flow Rate and Temperature

Series 46 Self-operated Regulators Differential Pressure and Flow Limiters Type 46-5 Type 46-6

AV 23 Balancing valves SETTER Inline

Seated valve (PN 16 & PN 25) VFM 2 Two way valve, flange

Pressure independent balancing and control valve AB-QM DN

Angle Seat Control Valve 7020

Pressure independent balancing and control valve AB-QM DN

2, 3 and 4 - way valves VZL

Series 240 Pneumatic On-off Valve Type 3351

Angle Seat Valve 7010

Angle Seat Valve 7010

Let motorized intelligence solve your application challenges

ARI-STEVI 470 / 471 (DN15-150)

Integrated Valve with Presetting for Manifolds in Two-Pipe Heating Systems

RA-N Valve Bodies with Pressfit Connection and Self-Sealing Tailpiece for Two Pipe Systems

Operating Guide SBFV (PN16/25) ENGLISH Steel butterfly valve SBFV Page 2. Danfoss VI.IX.A1.02 1

Self-operated Temperature Regulators Temperature Regulator Type 1u

V5825B. Small Linear Valve / PN25 DH Compact Valve. FEATURES Pressure-balanced k vs m 3 /hr Normally-closed valve

Manual Presetting Valves LENO MSV-B

ANSI version. The valve closes when the differential pressure rises

Technote. Frese YDF-2F & YDF-20F - differential pressure control valve. Application. Benefits. Features.

Two-port seat valves with male thread, PN16

Data Sheet T EN

3-Port Seat Valves with Male Thread, PN 16

Mounting and Operating Instructions EB 5894 EN. Electric control valves with jet pump. Flanged version of valve with jet pump

Extensions to a comprehensive product range

Pressure relief controller V22 D28

3-Port Seat Valves with Male Thread, PN 16

DA 50. Differential pressure controllers Adjustable set-point

3-port seat valves, external thread, PN16

3/2-Way Valve DN 15 up to DN 40

Manual presetting valve MSV-C

Technische Dokumentation Technical Documentation

For industrial applications For marine applications With proximity switch. Piston type flow switches

Static Balancing Valve

Lined Butterfly Valve Pfeiffer Type BR 10a

ZONE CONTROLE / 2-WAY

3-port valves vxf42..

Control Valve with integrated positioner

Rotary Plug Valve BR 23e

Self-operated Pressure Regulators Type Universal Pressure Reducing Valve

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS

Sempell High Pressure Stop Valves Model VA510 (DIN)

2-way and 3-way globe valves

Transcription:

Data sheet Pressure independent control valve with integrated flow limiter AVQM (PN 16) - return and flow mounting Description Controllers are used together with Danfoss electrical actuators: AMV 0 1) AMV(E) 10 1) / AMV(E) 20 / AMV(E) 30 AMV(E) 13 1) / AMV(E) 23 / AMV(E) 33 with spring return function AMV 20 SL / AMV 23 SL / AMV 30 SL with stroke limitation 1) AMV 0 can be combined with DN controller only. AVQM combined with AMV(E) 13, AMV(E) 23 (SL) or AMV(E) 33 (SL) has been approved according to DIN 32730. AVQM is a self-acting flow controller with integrated control valve developed for the use in district heating / cooling systems. The controller prevents flow to exceed set max flow. In a combination with electrical actuators AMV(E) and ECL electronic controllers the flow and temperature can be controlled to achieve highest energy savings. Main data: DN -32 k VS 0.4-10 m 3 /h Flow range 0.0-6.0 m 3 /h PN 16 Differential pressure over control valve Δp MCV 0.2 bar Temperature: Circulation water / glycolic water up to 30 % 2 0 C Connections: Ext. thread (weld-on, thread and flange tailpieces) AVQM has a control valve with adjustable flow limiter, connection neck for electrical actuator and a pressure actuator with one control diaphragm. Ordering AVQM Controller Example: Flow controller with integrated control valvefor flow rate 0.7 m 3 /h; PN 16; T max 0 C; ext. thread - 1 AVQM DN controller Code No: 003H6735 Option: - 1 Weld-on tailpieces Code No: 003H6908 The controller will be delivered completely assembled, inclusive impulse tube between valve and actuator. Electrical actuator AMV(E) must be ordered separately. Picture DN Q max k VS Connection Code No. (mm) (m 3 /h) (m 3 /h) 0.18 0.4 003H6733 0.4 1.0 003H6734 0.9 1.6 G ¾ A 003H6735 1.6 2.5 003H6736 Cylindr. ext. thread acc. to ISO 228 / 1 2.4 4.0 003H6737 20 3.5 6.3 G 1 A 003H6738 25 4.5 8.0 G 1¼ A 003H6739 32 6 10 G 1¾ A 003H6740 Danfoss 2017.11 VD.DB.V7.02 1

Ordering (continuous) Accessories Picture Type designation DN Connection Code No. 003H6908 Weld-on tailpieces 20 003H6909-25 003H6910 32 003H6911 R ½ 003H6902 External thread tailpieces 20 Conical ext. thread acc. to R ¾ 003H6903 25 EN 10226-1 R 1 003H6904 32 R 1¼ 003H6905 003H69 Flange tailpieces 20 Flanges PN 25, acc. to EN 1092-2 003H6916 25 003H6917 Service kits Picture Type designation DN k VS (m 3 /h) Code No. 0.4 003H6861 1.0 003H6862 1.6 003H6863 Valve insert 2.5 003H6864 4.0 003H6865 20 6.3 on request 25 8.0 32 10 003H6867 0.4 003H6886 1.0 003H6887 1.6 003H6888 Control valve insert 2.5 003H6889 4.0 003H6890 20 6.3 003H6891 25 8.0 003H6892 32 10 003H6795 Type designation Δp setting range (bar) Code No. Actuator 0.2 003H6825 2 Danfoss 2017.11 VD.DB.V7.02

Technical data Valve Nominal diameter DN 20 25 32 k VS value of dp controller Range of max. flow setting p MCV = 0.2 bar 0.4 1.0 1.6 2.5 4.0 6.3 8.0 10 Q m 3 min /h 0.0 0.02 0.03 0.07 0.07 0.16 0.2 0.16 Q max 2) 0.18 0.4 0.9 1.6 2.4 3.5 4.5 6.0 Available Δp required for Q max bar 0.4 0.4 0.5 0.6 0.6 0.5 0.5 0.6 Stroke mm 5 7 Control valve authority Control characteristic 1 (100%) in the range of flow setting Logarithmic Cavitation factor z 0.6 0.55 Leakage acc. to standard IEC 534 % of k VS 0.02 0.05 Nominal pressure PN 25 Min. differential pressure see remark 1) bar Max. differential pressure 12 Medium Circulation water / glycolic water up to 30 % Medium ph Min. 7, max. 10 Medium temperature ºC 2 0 Connections Materials Valve body valve tailpieces External thread Weld-on and external thread Flange - Red bronze CuSn5ZnPb (Rg5) Valve seat Stainless steel, mat. No. 1.4571 Valve cone Sealing DP Sealing MCV Pressure relieve system Dezincing free brass CuZn36Pb2As Control valve insert - Valve insert EPDM Metal Piston Note: DP - diff. pressure controller, MCV - control valve 2) For flows smaller than Q max -> p Actuator Type min Q k VS 2 p Actuator size cm 2 39 Nominal pressure PN 16 Differential pressure over MCV - motorized control valve bar 0.2 Materials MCV AVQM Housing Zinc chromatic steel, DIN 1624, No. 1.0338 Diaphragm Impulse tube EPDM Copper tube Ø 6 1 mm Manometric Pressure downstrem [bar] No Cavitation noise T=0 C T=130 C T=80 C Cavitation noise Manometric Pressure upstrem [bar] Cavitation area for cavitation factor z=0.6 VD.DB.V7.02 Danfoss 2017.11 3

Application principles Return mounting Flow mounting Indirectly connected heating system Indirectly connected heating system Installation positions Media temperature 100 C Media temperature 130 C Media temperature 0 C Electrical actuator Note! Installation positions for electrical actuators AMV(E) have to be observed as well. Please see relevant Data sheet. Pressure temperature diagram PN 16 CuSn5ZnPb (Rg5) PN 16 Maximum allowed operating pressure as a function of medium temperature (according to EN 1092-3). 4 Danfoss 2017.11 VD.DB.V7.02

Design 1. Control valve insert 2. Adjustable flow restrictor 3. Valve body 4. Valve insert 5. Pressure relieved valve cone 6. Valve stem 7. Built-in spring for flow rate control 8. Control drain 9. Actuator 10. Control diaphragm 11. Union nut 12. Impulse tube 13. Compression fitting for impulse tube 14. Excess pressure safety valve Function Flow volume causes pressure drop across the adjustable flow restrictor. Resulting pressures are being transferred through the impulse tubes and/or control drain in the actuator stem to the actuator chambers and act on control diaphragm for flow control. The flow restrictor diff. pressure is controlled and limited by means of built-in spring for flow control. Control valve closes on rising differential pressure and opens on falling differential pressure to control max flow. Additionally the electrical actuator will operate from zero to set max. flow according to the load. Controller is equipped with excess pressure safety valve, which protects control diaphragm for flow control from too high differential pressure. Settings Max flow limiting Max flow limiting is being done by the adjustment of the flow restrictor position. The adjustment can be performed on the basis of flow adjustment diagram (see relevant instructions) and / or by the means of heat meter. VD.DB.V7.02 Danfoss 2017.11 5

Dimensions 5 L 121 121 H 3 H 4 H 2 AMV(E) 2./ 3. + AVQM (DN -32) 277 H H 1 Ø 106 DN AVQM (DN -32) L H H 1 Weight mm (kg) 65 97 72 1.9 20 70 97 72 1.9 25 75 97 75 2.0 32 100 97 76 2.5 DN H 2 H 3 H 4 mm 289 276 279 20 289 276 279 25 292 279 282 32 293 280 283 92 AMV(E) 10 + AVQM (DN -32) AMV(E) 13 + AVQM (DN -32) AMV 0 + AVQM (DN ) L 3 L 2 L 1 d 2 n d R k SW SW SW 45 DN R 1) SW d L 1 2) L 2 L 3 k d 2 n mm 1/2 32 (G 3/4A) 21 130 120 139 65 14 4 20 3/4 41 (G 1A) 26 0 131 4 75 14 4 25 1 50 (G 11/4A) 33 160 145 9 85 14 4 32 11/4 63 (G 1³/4A) 42-177 184 100 18 4 1) Conical ext. thread acc. to EN 10226-1 2) Flanges PN 25, acc. to EN 1092-2 6 Danfoss 2017.11 VD.DB.V7.02

VD.DB.V7.02 Danfoss 2017.11 7

Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary eady agreed. All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. 8 Danfoss DHS-SRMT/SI 2017.11 VD.DB.V7.02