NYISO Tariffs. New York Independent System Operator, Inc. Document Generated On: 2/27/2013

Similar documents
MMP Investigation of Arthur Kill 2 and 3

Ancillary Services. Horace Horton Senior Market Trainer, Market Training, NYISO. New York Market Orientation Course (NYMOC)

Reactive Power Requirements and Financial Compensation. Addendum to Draft Final Proposal

Schedule SP SOLAR PURCHASE (Experimental)

Capacity Market Rules for Energy Storage Resources

Consolidated Edison Company of New York, Inc.

SERVICE CLASSIFICATION NO. 7 LARGE GENERAL TIME-OF-DAY SERVICE

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

Fuel Charges in Reference Levels

Louisville Gas and Electric Company

Department of Market Quality and Renewable Integration November 2016

NORTHWEST NATURAL GAS COMPANY P.U.C. Or. 25 Second Revision of Sheet 3-1 Cancels First Revision of Sheet 3-1

Proposal Concerning Modifications to LIPA s Tariff for Electric Service

TRANSMISSION PLANNING CRITERIA

Large General Service Time-of-Use Storage Program

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

NSTAR ELECTRIC COMPANY M.D.P.U. No. 28 EASTERN MASSACHUSETTS CAMBRIDGE SERVICE AREA GENERAL SERVICE

TEXARKANA, TEXAS SERVICE AREA. First Revised Sheet No /7

RAPPAHANNOCK ELECTRIC COOPERATIVE SCHEDULE NEM-8 NET ENERGY METERING RIDER

Proposal Concerning Modifications to LIPA s Tariff for Electric Service

STATE CORPORATION COMMISSION DIVISION OF PUBLIC UTILITY REGULATION. May 22, 2018

October 17, Please contact the undersigned directly with any questions or concerns regarding the foregoing.

SERVICE CLASSIFICATION NO. 7. Also optional for: This option is not available to Service Classification No. 2 customers, effective December 3, 2002.

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

TEXARKANA, TEXAS SERVICE AREA. Original Sheet No /6. CenterPoint Energy Resources Corp. d/b/a CenterPoint Energy Arkansas Gas (Name of Company)

KANSAS CITY POWER AND LIGHT COMPANY P.S.C. MO. No. 7 Fourth Revised Sheet No. 39 Canceling P.S.C. MO. No. 7 Third Revised Sheet No.

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

Forensic Sciences Chapter ALABAMA DEPARTMENT OF FORENSIC SCIENCES ADMINISTRATIVE CODE CHAPTER IGNITION INTERLOCK RULES

WOLFEBORO MUNICIPAL ELECTRIC DEPARTMENT NET METERING PILOT PROGRAM. Customer-Owned Renewable Energy Generation Resources (25 Kilowatts or Less)

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A

Appendix 6.7 January 23, 2015 SURPLUS ENERGY PROGRAM PROPOSED TERMS AND CONDITIONS

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E. San Francisco, California

MENARD ELECTRIC COOPERATIVE POLICY MANUAL. SECTION IV Operating Rules for Cooperative Members

of New York, Inc. Original Leaf No. 216 SERVICE CLASSIFICATION NO. 3 BACK-UP SERVICE

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

Portland General Electric Company Fourteenth Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Thirteenth Revision of Sheet No.

Behind the Meter Net Generation Model Cost Allocation for BTM Loads

AUSTIN UTILITIES. CHARACTER OF SERVICE: AC, 60 cycles, 120/240 Volt, three wire, single-phase; or 120 Volt, two wire.

CAPACITY LIMITED RESOURCES (CLR) / ENERGY LIMITED RESOURCES (ELR)

RATE 765 RENEWABLE FEED-IN TARIFF

August 15, Please contact the undersigned directly with any questions or concerns regarding the foregoing.

THE EMPIRE DISTRICT ELECTRIC COMPANY P.S.C. Mo. No. 5 Sec. 4 1st Revised Sheet No. 23

Thank you for your time and attention to this matter. Please feel free to contact me if you have any questions regarding the filing.

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

SCHEDULE NO. ACG33 NET METERING SERVICE

Schedule DP-1 SMALL GENERAL SERVICE (EXPERIMENTAL)

RATE DS-2 SMALL GENERAL DELIVERY SERVICE

2016 Load & Capacity Data Report

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

JACKSON ELECTRIC COOPERATIVE POLICY NO. 305

White River Electric Association, Inc. Net Metering Information & Service Requirements

Hurricane Sandy. Preparations, Response & Recovery. Wes Yeomans Vice President Operations Management Committee Meeting November 2, 2012

February 13, Docket No. ER ; ER Response to Request for Additional Information

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

RIDER RTP REAL-TIME PRICING

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES

STATE OF NEW HAMPSHIRE PUBLIC UTILITIES COMMISSION DE LIBERTY UTILITIES (GRANITE STATE ELECTRIC) CORP. d/b/a LIBERTY UTILITIES

Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No.

COMMUNITY SOLAR PROGRAM

BEFORE THE GUAM PUBLIC UTILITIES COMMISSION ) ) ) ) ) ) ) ) ORDER INTRODUCTION

GENERAL INFORMATION. 13. SERVICE CLASSIFICATION RIDERS (Continued) RIDER N NET METERING FOR CUSTOMER GENERATORS

January 18, Docket: ER Energy Imbalance Market Special Report Transition Period August 2018 for Idaho Power Company

ELECTRIC SCHEDULE E-1 Sheet 1 RESIDENTIAL SERVICES

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

December 4, Docket: ER Energy Imbalance Market Special Report Transition Period July 2018 for Idaho Power Company

Review of Reliability Must-Run and Capacity Procurement Mechanism BBB Issue Paper and Straw Proposal for Phase 1 Items

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. LARGE MANUFACTURING SERVICE RATE SCHEDULES (November 2018)

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

California Independent System Operator Corporation Fifth Replacement Electronic Tariff

TERMS AND CONDITIONS

MINIMUM OIL BURN/AUTOMATIC FUEL SWAPPING CAPABILITY

CN is offering our Fleet Integration Program for grain shippers who are using privately owned, covered hopper cars for

Energy Forum: Demand Side Management & May 6, 2010

P.S.C. No. 9 - Electricity Consolidated Edison Company First Revised Leaf No. 310 of New York, Inc. Superseding Original Leaf No.

Edmond Electric Standard Pricing Schedules

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-21 PRICE PLAN FOR RESIDENTIAL SUPER PEAK TIME-OF-USE SERVICE

Ancillary Services. Horace Horton. Market Overview Course. Senior Market Trainer, Market Training, NYISO. March 8, Rensselaer, NY 12144

WASHINGTON ELECTRIC COOPERATIVE, INC. NET METERING TARIFF POLICY BULLETIN NO. 38 NM

APPENDIX D. REGULATIONS (excerpts) ON 24-HOUR EMISSION LIMITS: MARYLAND DEPARTMENT OF THE ENVIRONMENT

P.S.C. No. 9 - Electricity Consolidated Edison Company First Revised Leaf No. 244 of New York, Inc. Superseding Original Leaf No.

Contents. Solar Select TM Frequently Asked Questions

2019 BQDM Extension Auction Frequently-Asked Questions Updated January 29, 2018

2015 GENERAL FIRM POWER SERVICE RATE STUDY SUMMARY REPORT

Docket No. ER June 2018 Informational Report Energy Imbalance Market Transition Period Report Idaho Power Company

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

ELECTRICAL GENERATING STEAM BOILERS, REPLACEMENT UNITS AND NEW UNITS (Adopted 1/18/94; Rev. Adopted & Effective 12/12/95)

MASSACHUSETTS ELECTRIC COMPANY NANTUCKET ELECTRIC COMPANY NET METERING PROVISION

FUEL ADJUSTMENT CLAUSE


Umatilla Electric Cooperative Net Metering Rules

RULES FOR CUSTOMER INTERCONNECTION OF ELECTRIC GENERATING FACILITIES

February 10, The Honorable Kimberly D. Bose Secretary Federal Energy Regulatory Commission 888 First Street, NE Washington, DC 20426

National Research Council

Schedule No. NMR-405 NET METERING RIDER-405 APPLICABLE

Montgomery Township Community Energy Aggregation

Western NY Public Policy Transmission Planning Report

Transcription:

NYISO Tariffs New York Independent System Operator, Inc. NYISO Tariffs Document Generated On: 2/27/2013

Contents 15 ISO Market Administration and Control Area Service Tariff Rate Schedules... 8 15.1 Rate Schedule 1 ISO Annual Budget Charge and Other Non Budget Charges and Payments. 9 15.2 Rate Schedule 2 Payments for Supplying Voltage Support Service... 10 15.2.1 Responsibilities... 10 15.2.1.1 Suppliers... 10 15.2.2 Payments... 12 15.2.2.1 Annual Payment for Voltage Support Service... 12 15.2.2.2 Lost Opportunity Costs... 13 15.2.2.3 Other Payments to Synchronous Condensers and Qualified Non Generator Voltage Support Resources... 14 15.2.3 Failure to Perform by Suppliers... 15 15.2.4 Failure to Respond to ISO's Request for Steady State Voltage Control... 16 15.2.5 Failure to Provide Voltage Support Service When a Contingency Occurs on the NYS Power System... 18 15.2.7 Consistence with Cross Sound Scheduled Line Protocols... 20 15.3 Rate Schedule 3 Payments for Regulation Service... 21 15.3.1 Obligations of the ISO and Suppliers... 21 15.3.1.1 The ISO shall:... 21 15.3.1.2 Each Supplier shall:... 22 15.3.2 Selection of Suppliers in the Day Ahead Market and the Real Time Market... 23 15.3.2.1 Bidding Process... 24 15.3.3 Monitoring Regulation Service Performance and Performance Related Payment Adjustments... 25 15.3.4 Regulation Service Settlements Day Ahead Market... 25

15.4.6.1 Calculation of Real Time Market Clearing Prices... 56 15.4.6.2 Calculation of Real Time Market Clearing Prices for Operating Reserves During EDRP/SCR Activations... 59 15.4.6.2.1 During Intervals When Scarcity Pricing Rule A Applies... 59 15.4.6.2.2 During Intervals When Scarcity Pricing Rule B Applies... 60 15.4.6.3 Operating Reserve Balancing Payments... 61 15.4.6.4 Other Real Time Payments... 62 15.4.7 Operating Reserve Demand Curves... 63 15.4.8 Self Supply... 67 15.5 Rate Schedule 5 Payments and Charges for Black Start and System Restoration Services... 69 15.5.1 Requirements... 69 15.5.2 Payments to Generators for Provision of Restoration Services Under the ISO Plan and Transmission Owners Plans, Excluding the Consolidated Edison Plan... 70 15.5.3 Charges to Support Payments to Generators Under the ISO Plan and Individual Transmission Owners Plans, Excluding the Consolidated Edison Plan.... 71 15.5.4 Payments to Generators Providing Restoration Services Under the Consolidated Edison Plan and Recovery of Associated Costs... 72 15.5.4.1 Payments to Generators that Committed to Provide Restoration Services Under the Consolidated Edison Plan Before November 1, 2012, and Elected to Provide Service Under Then Existing Terms... 73 15.5.4.2 Payments to Generators that Committed to Provide Restoration Services Under the Consolidated Edison Plan On or After November 1, 2012, or Before November 1, 2012 and Elected to Provide Service Under New Terms... 75 15.5.4.2.1 Commitment Requirements for Restoration Services... 75 15.5.4.2.2 Generator Testing and Training Requirements... 77 15.5.4.2.3 Payments to Generators for Providing Restoration Services Under the Consolidated Edison Plan 77 15.5.4.2.3.1 Standard Compensation... 77 15.5.4.2.3.2 Unit Specific Compensation... 80

MST Rate Schedules - 15.5 MST Rate Schedule 5 - Payments and Charges for Black St 15.5.4.2.2 Generator Testing and Training Requirements A Generator shall conduct an annual Black Start Capability Test of each unit that it has committed to provide Restoration Services under the Consolidated Edison Plan in accordance with the test protocols set forth in Appendix II to this Rate Schedule. A Generator shall also identify its unit s critical Restoration Services equipment, maintain this equipment and perform tests to verify the condition of this critical equipment in accordance with good utility practice. Upon the performance of a Black Start Capability Test for its unit, the Generator shall submit a certification to the ISO each year in the form provided in Appendix III to this Rate Schedule indicating whether its unit has successfully completed its annual Black Start Capability Test and certifying that it maintains and tests the unit s critical Restoration Services equipment in accordance with good utility practice. The Generator shall also ensure that all appropriate personnel are trained in Restoration Services operations. Effective Date: 11/1/2012 - Docket #: ER12-2568-002 - Page 77

I. General Rate Schedule 5. Appendix II Testing Criteria for Black Start Capability Tests Pursuant to Section 15.5.4.2 of Rate Schedule 5 1. A Generator shall perform a Black Start Capability Test annually for each of its units providing Restoration Services in accordance with the test protocols described below. 2. A Black Start Capability Test will be considered successful if it is completed in accordance with the test protocols described below. II. Scheduling a Test 1. A Generator shall perform the annual Black Start Capability Test for its unit(s) between May 1 st to April 30 th, as may be reasonably extended by mutual agreement among the Generator, Consolidated Edison and the ISO, without financial penalty; provided, however, that the Generator shall not perform a Black Start Capability Test in June, July, or August. 2. The test date must be agreed upon by Consolidated Edison, the Generator and the ISO. The agreed upon test date shall be deemed firm as of 48 hours prior to the scheduled beginning of the test. A firm test may not be called off or deferred except by the ISO for system or local reliability reasons. As is the case for any ISO-approved outage, the Generator shall not offer the unit into the Day-Ahead Market for operation during the Black Start Capability Test that day, and such non-offering into the market shall be deemed not to diminish the unit s availability. Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 88

3. An annual Black Start Capability Test may be performed prior to a maintenance outage only if there is no other scheduling option within the test period. 4 If the annual Black Start Capability Test is unable to be completed during the test period due to a forced outage or force majeure event, Consolidated Edison and the Generator will conduct the test outside the test period without a pro rata reduction in annual payments. 5. If a Black Start Capability Test is not successful, the Generator will have a reasonable opportunity to reschedule and conduct a subsequent test. 6. Consolidated Edison and the ISO may have representatives present to witness the annual Black Start Capability Test. However, witnesses are not required for the Generator to perform the test. III. Gas Turbine Unit Testing Requirements A Generator shall perform the following test for a gas turbine unit that is designated by Consolidated Edison to participate in the Consolidated Edison Plan as a gas turbine unit and not as part of a combined cycle facility. A. Test of Gas Turbine Unit That Is a Sole Black Start Unit 1. A Generator shall perform the following Black Start Capability Test each year for its gas turbine unit that is a Sole Black Start Unit. 2. A qualifying Black Start Capability Test of the gas turbine unit must be conducted when the unit is in a cold condition, i.e., the unit will be off line and will be brought on line specifically to conduct the test. Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 89

3. The gas turbine unit to be tested will be off line at the start of the Black Start Capability Test and will be isolated from all external Consolidated Edison light and power sources. 4. The Black Start Capability Test must demonstrate that the designated gas turbine unit can be started and can energize the isolated light and power bus. 5. Once isolated from Consolidated Edison s light and power bus, the Generator will have 80 minutes to ready the gas turbine unit and to request permission to synchronize the unit to a live bus on the Consolidated Edison transmission system. When authorized by the Consolidated Edison System Operator, the Generator will be asked to close the breaker for the gas turbine unit. Once the gas turbine unit has synchronized and its breaker has closed onto the transmission bus, the test will be considered successful. B. Test of Gas Turbine Units that Are Part of a Black Start Unit Group 1. A Generator shall perform the following Black Start Capability Test each year for one of the units of a Black Start Unit Group. Once the Generator has successfully completed an annual Black Start Capability Test of one of the units of the Black Start Unit Group, it should perform in subsequent years an annual test of the remaining units of the Black Start Unit Group. 2. A qualifying Black Start Capability Test of a gas turbine unit must be conducted when the unit is in a cold condition, i.e., the unit will be off line and will be brought on line specifically to conduct the test. 3. The gas turbine unit to be tested will be off line at the start of the Black Start Capability Test and will be isolated from all external Consolidated Edison light and power sources. Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 90

4. The Black Start Capability Test must demonstrate that (i) an isolated gas turbine unit can be started and can energize the isolated light and power bus; and (ii) that the light and power source is adequate for the purpose of bringing the other units on line. Part (ii) must be demonstrated by starting up an additional gas turbine unit from the light and power bus that has been energized through Part (i) of the test. 5. Once isolated from Consolidated Edison s light and power bus, the Generator will have 90 minutes to ready the equipment and to request permission to synchronize the additional generating unit to a live bus on the Consolidated Edison transmission system. When authorized by the Consolidated Edison System Operator, the Generator will be asked to close the breaker for the additional gas turbine unit. Once the additional gas turbine unit has synchronized and its breaker has closed onto the transmission bus, the test will be considered successful. IV. Combined Cycle Unit Testing Requirements 1. A Generator shall perform each year a Black Start Capability Test for its gas turbine and steam turbine units that are designated by Consolidated Edison to participate in the Consolidated Edison Plan as part of a combined cycle facility. 2. A qualifying Black Start Capability Test must be conducted when the combined cycle unit is isolated from the transmission system. The combined cycle unit must demonstrate that the designated gas turbine(s) unit can be started and can energize the isolated light and power bus; and that the light and power source is adequate for the purpose of bringing the steam turbine(s) on line. For a successful Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 91

Black Start Capability Test, the steam turbine(s) must synchronize to the transmission system within 6 hours of the start of the Black Start Capability Test. V. Steam Turbine Unit Testing Requirements A Generator shall perform the following test for a steam turbine unit that is designated by Consolidated Edison to participate in the Consolidated Edison Plan as a steam turbine unit and not as part of a combined cycle facility. A. Comprehensive Black Start Capability Test 1. A Generator shall perform a Comprehensive Black Start Capability Test at least once every three years for its steam turbine unit(s) providing Restoration Services. 2. A qualifying Comprehensive Black Start Capability Test of a steam turbine unit may be conducted while the unit is in a cold condition or in a hot condition. If the steam turbine unit is in a cold condition its internal light and power bus may remain connected to the transmission system until it reaches a hot condition at which point it will separate from the transmission system and commence its test. 3. The steam turbine unit must be isolated from the transmission system and an isolated cranking path between it and a black start gas turbine unit must be established. The steam turbine unit is required to start up using energy and voltage control from the gas turbine unit to energize its internal light and power bus, and be ready to synchronize to an energized transmission system when directed by the Consolidated Edison System Operator. 4. A Comprehensive Black Start Capability Test shall be considered successful if, after isolation from the Consolidated Edison transmission system, the hot steam unit is synchronized to the transmission system, and is firm to the system and Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 92

operating at minimum load in no more than 8 hours after the completion of the isolation. 5. Upon successful completion of the Comprehensive Black Start Capability Test, Consolidated Edison shall SRE the unit until midnight of the test day or until the unit s reference minimum run time has elapsed, whichever is earlier. B. Intervening Years Black Start Capability Test 1. To meet its annual steam turbine unit test obligation, a Generator may perform an Intervening Years Black Start Capability Test for its steam turbine unit(s) providing Restoration Services if it has successfully completed a Comprehensive Black Start Capability Test of that unit within the prior two years. 2. The steam turbine unit must be isolated from the transmission system and a cranking path between it and a black start gas turbine unit must be established. The steam turbine unit is required to use energy and voltage control from the gas turbine unit to energize the internal light and power bus. The steam turbine unit is then required to add the auxiliary load that is required to introduce fire into its boiler, e.g., boiler feed pump, fans, etc, except that no fire is required to be introduced into the boiler. 3. An Intervening Years Black Start Capability Test shall be considered successful if the gas turbine unit demonstrates ten minutes of steady operation supplying its load at the internal light and power bus within four hours after the completion of the isolation. Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 93

VI. Reporting and Additional Testing Requirements 1. If an ISO representative is not onsite, a representative from the Generator will initiate calls to ISO operations personnel to signal the start time, completion time and outcome of the Black Start Capability Test. 2. Following its performance of a Black Start Capability Test for its unit, the Generator shall submit a certification form to the ISO in the form provided in Appendix III to this Rate Schedule indicating whether its unit successfully completed its annual Black Start Capability Test. Consolidated Edison shall acknowledge to the ISO its acceptance of a Generator s successful completion of the Black Start Capability Test. 3. A Generator will perform tests of its unit s critical Restoration Services equipment, including monthly tests of standby diesel generators, black start gas turbines and UPS/battery back up systems. As part of its annual certification to the ISO, the Generator shall certify in the form provided in Appendix III to this Rate Schedule that it maintains and tests its unit s critical Restoration Services equipment in accordance with good utility practice. If any of these critical systems are found to be non-operational or otherwise unavailable, the Generator will notify Consolidated Edison and the ISO within 36 hours and provide a schedule for their repair and return to service. Effective Date: 11/1/2012 - Docket #: ER12-2568-000 - Page 94