Electronic Precision Metering. Built to exceed API 675 performance standards with pulse-free linear flow

Similar documents
Selection Guide for P Series Pump Accessories & Options

WANNER ENGINEERING INC

Metering Pumps with Pulse-Free Linear Flow

Metering Pumps with Pulse-Free Linear Flow

MT8 Pump. Triplex Metering Pump with Pulse-Free Linear Flow

Pulsation Dampeners NEW! Wanner Engineering Inc

Durability, performance and simplicity of design make Hydra-CelfB pumps the optimum choice for the widest range of pum applications.

Chemical and Petrochemical Process

Condensed Catalog. Seal-less Pumps

Chemical and Petrochemical Process

T100 Series Medium Pressure Models T100K & T100M

Oil & Gas Processing. Seal-less Pumps. Reliable Pumps for Oil and Gas Processing with No Seals or Packing to Leak or Replace

Versatile, Reliable Pumps for a Wide Range of Applications H25 Series

G20 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G20 Close-coupled with Brass pump head ATEX. G20 Version 5 10/16

Versatile, Reliable Pumps for a Wide Range of Applications D10 Series

T100 Series High Pressure

69 bar (1000 psi) for Metallic Pump Heads 24 bar (350 psi) for Non-metallic Pump Heads

Hydra-Cell Metering Accessories and Options

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Valve Accessories NEW! Wanner Engineering Inc

Versatile, Reliable Pumps for a Wide Range of Applications D35 Series

Lifting Instructions for 1336 PLUS and FORCE D Frame Drives

G03 Mono-Block Series

G15 Series API bar (2500 psi) for Metallic Pump Heads. G15 for horizontal installations shown with Stainless Steel pump head.

Accurate Metering and Superior Handling of Abrasives in the Manufacture of Engineered Wood Products. Engineered Wood

G35 Series API bar (1500 psi) for Metallic Pump Heads. G35 with Stainless Steel pump head and SAE flanges. G35 with Brass pump head

G25 Series API bar (350 psi) for Non-metallic Pump Heads. G25 with Cast Iron pump head

G03 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G03 Shaft-driven with Stainless Steel pump head

G66 Series API bar (250 psi) for Non-metallic Pump Heads. G66 with Ductile Iron pump head. G66 with Polypropylene pump head.

Versatile, Reliable Pumps for a Wide Range of Applications M03 Mono-Block Series

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Infographics on Electromobility (January 2019)

103 bar (1500 psi) for Metallic Pump Heads

T100 Series Medium Pressure Models T100K & T100M

PULSAPRO HYDRAULIC DIAPHRAGM METERING PUMP API-675 ENGINEERED PRODUCTS. Flow: up to 270 gph (1,022 lph) Pressure: up to 5,100 psi (350 bar)

Versatile, Reliable Pumps for a Wide Range of Applications D66 Series

BP Statistical Review of World Energy June 2017

Models: G-25, H-25 With Non-Metallic Pump Head

T100 Series Low Pressure Models T100E, T100F & T100H

Models: G-25, H-25 With Metallic Pump Head

Versatile, Reliable Pumps for a Wide Range of Applications M03 Series

MODELS: G-20, G-21, G-22

Versatile, Reliable Pumps for a Wide Range of Applications M03 Series

Hydracel High Pressure Pump

Total credit to the non-financial sector (core debt), % of GDP Table F1.1

AUSTRIA. Table 1. FDI flows in the host economy, by geographical origin. (Millions of US dollars)

ProMinent Meta METERING PUMPS. ProMinent

Global Dialysis - Cost per Dialysis Session

P200 Metering Pump. Installation & Service P A WANNER ENGINEERING, INC. Metallic Pump shown (Motor Optional)

WORLD MOTOR VEHICLE PRODUCTION BY COUNTRY AND TYPE QUARTERS June 14, 2018

C Series Valves C24 1-1/4 NPT C23 1 NPT C22 3/4 NPT. C22/C23/C24 Series. Stainless Steel Off-Line Brass Off-Line. Brass In-Line.

The new STx chain hoist NEW. Sophisticated technology prepared for the future

G03 Series Dosing Range

Imports of seed for sowing by country Calendar year 2011 Source: ISF compilation based on official statistics and international seed trade reports

Primary energy. 8 Consumption 9 Consumption by fuel. 67 th edition

G04 Series. Maximum Flow Rate: 11.2 l/min (2.9 gpm) Maximum Pressure: 200 bar (2900 psi) for Metallic Pump Heads. G04 with Stainless Steel pump head

INDUSTRIAL PUMPS MODEL: D-35 PARTS MANUAL WANNER ENGINEERING, INC. IMPORTANT

P100 Metering Pump. Installation & Service P A WANNER ENGINEERING, INC. Metallic Pump shown (Motor Optional)

T100 Series Medium Pressure Models T100K & T100M

Made UNDER high pressure

T100 Series Medium Pressure Models T100K & T100M

Models: D-12, G-12. Parts Manual D D WANNER ENGINEERING, INC.

INDUSTRIAL PUMPS PARTS MANUAL MODELS: M-03 D-03 M-23 M-24 G-03 G-13 WANNER ENGINEERING, INC. IMPORTANT

Rectangular photoelectric proximity switches

Model: D-10. Parts Manual D B. with non-metallic pump head WANNER ENGINEERING, INC. IMPORTANT

Reliable Pumps for Oil and Gas Processing with No Seals or Packing to Leak or Replace. Oil & Gas Processing

Portable Compressors MOBILAIR M 122 With the world-renowned SIGMA PROFILE Free air delivery 11.1 m³/min

MODEL: G-25 WITH METALLIC PUMP HEAD

Better sealing solutions for reciprocating compressors

T100 Series Low Pressure Models T100E, T100F & T100H

Models: D-03, G-03, G-13, M-03 and M-23 Mono-Block Kel-Cell Versions

Models: D-03, G-03, G-13 and M-03

Product Overview INCH

D/G-10 Series. Up to 8 gpm (30.3 l/min) D/g-10 hydra-cell diaphragm pump. D/G-10 Specialized Designs

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Jaeco AgriPumps for Chemigation

CSM-K. high capacity clean steam generator

Materials of Construction Head materials in PVDF, 316 SS, and PP Ball Valves - Ceramic, and 316 SS Diaphragm - PTFE faced Hypalon.

MT8 Metering Pump. Installation, Operation & Maintenance Chestnut Avenue, Minneapolis, MN 55403

D6.. Butterfly valves. For controlled operation.

67 th edition. Renewable energy. Appendices. 44 Other renewables consumption 45 Biofuels production

Fork through-beam sensors

manifolds Innovative solutions to increase quality and reduce cost You can see our thinking

Allen-Bradley 1397 Pulse Encoder Interface Card

D/G-12 Series. Up to 8 gpm (30.3 l/min)

Seal-less Pump Technology. Oil and Gas. Robust design - Reliability

1. INTERNATIONAL OVERVIEW. 1.0 Area and population. population (1,000) area

Fork through-beam sensors

Packing Data Installation Instructions

Electric Diaphragm Pumps

DIAPHRAGM METERING PUMPS

PROPORTIONALADVANTAGE

P400 Metering Pump. Installation, Operation & Maintenance P C. Metallic pump shown W0014B

mroy Series Hydraulic Diaphragm Metering Pumps

H/G-25 Series. Up to 20 gpm (75.7/min) H/g-25 hydra-cell diaphragm pump. H/G-25 Specialized Designs

UAE draft regulation for Electric Vehicle

Drive solutions for the oil and gas industry.

D/G-04 Series. Up to 3.0 gpm (11.3 l/min)

Mechanical Diaphragm Metering Pump

Transcription:

Electronic Precision Metering Built to exceed API 675 performance standards with pulse-free linear flow

Contents Page(s) Introduction....................................... 3 Markets Served..................................... 3 Primary Applications................................. 3 Fluid Handling Capability............................. 3 Operational & Cost Advantages...................... 4-5 Electronic Flow Control..................... 4 Choice of Materials......................... 4 Reduced Pulsations........................ 4-5 Economy through Technology................. 5 Design Features & Performance Benefits.............. 6-7 API 675 Performance Standards...................... 8-9 Flow Capacities & Pressure Ratings................... 10 Multiplex Capability................................ 11 Model Specifications & Ordering Information......... 12-23 P100................................. 12-13 P200................................. 14-15 P300................................. 16-17 P400................................. 18-19 P500................................. 20-21 P600................................. 22-23 System Installation Example.......................... 24 Accessories & Options........................... 24-25 Hydra-Cell Bare Shaft Pumps........................ 26 Worldwide Sales & Service.......................... 27 If the owner of a plant wants costeffective pumps...he will buy pumps with the lowest Life Cycle Cost. Hydra-Cell is simple in construction, less elaborate in design and physically smaller for equivalent flow/pressure performance.these differences can substantially affect both purchase and operating costs. Dr. Ing Friedrich Wilhelm Hennecke Chemical Engineering World June 2006 2

www.hydra-cell.com/metering Hydra-Cell is not an Ordinary Metering Pump The technology used to produce ordinary metering pumps has barely changed in over a generation. As a result, ordinary metering pumps have operational limitations and greater cost consequences. Hydra-Cell is not an ordinary metering pump. Hydra-Cell Metering Solutions pumps enable you to meet and, in most cases, exceed API 675 performance standards with virtually pulse-less, linear flow while providing many other operational benefits. Taking advantage of the most current technologies, Hydra-Cell P Series metering pumps achieve superior levels of accuracy, repeatability and linearity, while delivering precise, constant flow. This revolution in metering employs the latest available means of electronic flow control to replace antiquated, inaccurate stroke adjusters. In addition, the modern design features of the Hydra-Cell pump lower your acquisition costs when compared to ordinary metering pumps, and its inherently simple yet elegant engineering keeps your maintenance and replacement costs down. Rugged construction and long-lasting durability will provide economy and value over the lifetime of your Hydra-Cell metering system. Used in place of ordinary metering pumps to provide superior performance at a lower cost, Hydra-Cell is an extraordinary metering pump built to handle your precise metering and dosing applications. Markets Served: Agriculture Biotech & Pharmaceutical Chemical Process Food & Beverage Glass & Clay Oil, Gas & Petrochemical Paints, Coatings, Sealants & Adhesives Pulp, Paper & Textiles Rubber & Plastics Water & Wastewater Treatment Primary Applications: Coating Dosing Filling Filtering Injecting Metering Mixing Printing Spraying Transferring Fluid Handling Capability: Propane/ Freon Ammonia Polymers Fuels/ D.I.Water Glycols Chlorine Acids/ Glues/ Inks/ Resins Slurries Butane Additives Caustics Adhesives Paints 3

Operational & Cost Advantages of Hydra-Cell Metering Solutions Electronic flow control is more accurate and reliable. Ordinary metering pumps rely on manual stroke adjustment or expensive actuators to change flow. This can result in pumping inaccuracies, lost motion, operator error, and a greater chance of leakage. Hydra-Cell uses Variable Frequency Drive (VFD) electronic flow adjustment to maintain greater accuracy throughout the turndown range. It meets or exceeds API 675 performance standards while eliminating lost motion and a potential leak path. Compared to many ordinary metering pumps, electronic flow control of Hydra-Cell reduces the chance of operator error and offers several other advantages: Hydra-Cell offers PTFE diaphragms as well as the following cost-effective elastomeric materials: Viton Buna EPDM Neoprene Aflas Electronic Flow Control Solid-state electronics (SCR, VFD, or solenoid pulser) are unlikely to fail Metering is linear over the entire range Volume per every stroke is constant and a known value Easy calibration of the desired feed rate Rate of change is virtually instantaneous (0 to max. RPM in 0.3 seconds) Manual Stroke Adjusters/Actuators Stepper motors or linear actuators driving against pressure are subject to wear and tear Losses in repeatability below 30% stroke length and losses through check valves Unknown with manual stroke adjustment and may not be proportional to the output Nearly impossible to calibrate unless a variable stroke rate or span-able controller is used Up to one (1) second per 1% of the stroke length A choice of diaphragm, check valve, and liquid end materials also enables Hydra-Cell pumps to operate over a wider range of processing applications. Plus, special materials such as Hastelloy C and Kynar are available in standard Hydra-Cell packages. Hydra-Cell is lower in cost compared to ordinary metering pumps that have substantial price adders for exotic liquid end materials. Reduced pulsations improve operation. Ordinary metering pumps produce pulsing, surging flow and require large pulsation dampeners that add cost and complexity to a metering system.this inherent problem with ordinary metering pumps creates greater strain on the system and more wear and tear on the pump. Greater choice of materials enhances capability. Ordinary metering pumps typically offer only PTFE diaphragms. When subjected to flex stresses, PTFE diaphragms do not have a memory like elastomeric diaphragms and will require more frequent and costly replacement due to stresses on the material. In addition, if fluid and process temperatures are low, and the PTFE diaphragm is cold, it can stiffen and cause irregularities in the output, and cause a drop in flow. All Hydra-Cell models (except P100) feature a multiple diaphragm design that virtually eliminates pulsations and provides several benefits: Reduces pipe strain. Enhances operating safety. Minimizes maintenance. Reduces acceleration losses. Eliminates the need for pulsation dampeners. Lowers system acquisition costs. Provides accurate metering with linear, constant flow. 4

www.hydra-cell.com/metering Bar 10.3 6.9 3.4 689 LPH Metering Pump Hydra-Cell P400 Compared to ordinary metering pumps operating under the same conditions at the same flow and pressure, Hydra-Cell metering pumps provide smooth, almost pulse-less performance.this allows for the design of a safer, less expensive metering pump system and for use in more accurate applications, such as spraying which cannot tolerate pulsing flow. 0 0 0.25 0.5 0.75 1 1.25 1.5 Seconds Achieve economy through technology. plunger and diaphragm sizes, and difficulty handling slurries and suspended solids. Ordinary metering pumps result in higher costs of acquisition, maintenance, and replacement. Hydra-Cell combines simple, elegant engineering with rugged construction to offer greater versatility while lowering life cycle costs. Design advantages include: Smaller footprint that offers the same capability as larger pumps which are often over-sized and overpriced as flow and pressure requirements increase. Each model covers an extensive range of pressures and flows, whereas ordinary metering pumps may need different plunger and liquid end sizes to accommodate increases. This Hydra-Cell pump shown to scale has the same flow capacity and pressure rating as an ordinary triplex metering pump but has a much smaller footprint, saving you valuable real estate in your facility. Ordinary metering pumps use technology in existence or unimproved upon for many years.this poses limitations such as inaccurate stroke adjusters, pulsation problems, limited choice of materials, narrow adjustable flow ranges, large footprints to handle high flows and pressures, different The inherent simplicity of the Hydra-Cell design allows versatile application compared to complex metering pumps that require expensive construction changes to meet specific needs. Simplicity also means lower parts and maintenance costs. A separate gearbox allows greater versatility in changing applications and prevents cross-contamination of actuating oil integral gearing on other pumps is difficult and expensive to change. 5

Design Features & Performance Benefits of Hydra-Cell Separate Gearbox Enables versatility in changing applications and prevents cross-contamination of actuating hydraulic oil. C-Face Motor Adapter Makes it easier to install or replace motors. (Variety of NEMA & IEC motor frames also available.) Inherent Simplicity Lowers acquisition costs, reduces maintenance costs, and minimizes labor costs. Lubricated Ball Bearings Ensure optimal pump life. Robust Construction Delivers long-lasting, durable operation in the toughest industrial and processing environments. Drain Plug Helps keep maintenance neat and easy. Extensive Choice of Materials Choice of diaphragm, check valve, and liquid end materials allows pumps to operate in a wider range of applications. Spring-Loaded Disk Check Valves Designed for superior handling of viscous fluids compared to floating, ball-style check valves. Multiple Diaphragms Provide smooth, almost pulseless performance with linear flow. 6

www.hydra-cell.com/metering Optimal Precision Full stroke - every stroke. More Accurate No manual stroke adjustment to cause inaccuracies, potential leakage and operator error. Variety of Flows & Pressures Same plunger, liquid end and diaphragm size. Space-Saving Significantly smaller footprint than comparably-rated metering pumps. Greater Repeatability Replenishment valve for continuous accuracy. Linear Flow Multiple diaphragms reduce pulsations and acceleration losses. Less Chance of Entrapped Air Porting is larger than normal to eliminate common oxygen scavenger metering problems. 7

Hydra-Cell Metering Solutions Pumps Meet or Exceed API 675 Performance Standards In 1994, the American Petroleum Institute (API) adapted its Standard 675 to stipulate performance characteristics for controlled-volume, positive displacement pumps. Although revised in 2000, API 675 primarily defined pumps using mechanical stroke adjustment. Hydra-Cell Metering Solutions meet or exceed API 675 performance standards by using electronic flow control to improve accuracy and a multi-diaphragm design to reduce pulsations. Used in precise metering, dosing, injection, and mixing applications, Hydra-Cell pumps provide an economical alternative to ordinary metering pumps. Operational Data for Testing Pump Configuration: P300NRGSS020S Reducer: 20:1 PSI: 1500 Actuating Oil: 10W-30 Hydra-Oil Ambient Temperature: 71.5 F Pumped Fluid: Water @72 F Gravity Feed: 1-to-3 Feet Positive Head Franklin IMDS Motor: 240-2400 RPM 1 HP Accuracy - Performance at a Set Point For continuous metering applications, Hydra-Cell P Series pumps provide precise steady-state accuracy of ±1% or better. 12.40 12.38 12.36 12.34 +1% of Set Point 12.32 12.30 12.28 12.26 12.24 Set Point (12.22 GPH) +0.5% of Set Point GPH 12.22 12.20 12.18 12.16 12.14-0.5% of Set Point 12.12 12.10 12.08 12.06 12.04-1% of Set Point API 675 ±1% of Set Point Hydra-Cell ±0.5% of Set Point 12.02 12.00 All parameters remain unchanged (NPSH, pressure, temperature, etc.). TIME (Capacity measurements taken every 20 minutes after steady-state pumping achieved. Pump ran 40 minutes prior to first data point.) All testing to API 675 performance standards conducted in the Wanner Engineering research and development laboratory (USA) based on gallons-per-hour (GPH). 8

www.hydra-cell.com/metering 14 13 Linearity - Speed/Flow Rate Relationship For smooth, virtually pulse-less performance, Hydra-Cell P Series pumps provide linear flow within ±3% or better. 12 11 10 9 8 GPH 7 6 5 4 3 2 1 Hydra-Cell Measured Flow Best Fit Line API 675 ±3% of Rated Capacity Pressure is constant. Maximum flow over a turndown ratio of 10:1. 0 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% CAPACITY SETTING (Motor RPM) Best Fit Line is drawn through the Measured Flow data points, taken at 100%, 75%, 50%, 25%, and 10% of Rated Capacity (12.25 GPH). GPH 12.50 12.00 11.50 11.00 10.50 10.00 9.50 9.00 8.50 8.00 7.50 7.00 6.50 6.00 5.50 5.00 4.50 4.00 3.50 3.00 2.50 2.00 1.50 1.00 0.50 0.00 Repeatability - Return to Set Conditions Hydra-Cell P Series pumps always return to ±3% or better of a set point condition after deviation (1200 RPM tested below). Rated Capacity: 12.25 GPH Measured Flow at Set Point Measured Flow of capacity variation API 675 ±3% of Rated Capacity Measured Flow of Set Point speed 600 RPM. 1200 600 240 1200 1800 1200 2400 1200 CAPACITY SETTING (Motor RPM) 9

Hydra-Cell Metering Solutions Capacities & Ratings 207 173 138 Bar 103 70 34 0 0 150 300 450 600 750 900 1050 1200 1350 1500 1650 1800 1950 2100 2250 2400 2550 2700 LPH Hydra-Cell Metering Solutions pumps comprise six standard models, each with a wide range of flow capacities and pressure ratings to lower costly stocking requirements. Hydra-Cell can also handle capacities greater than 2634 LPH. See page 26 (Hydra-Cell Bare Shaft Pumps) or contact us for more information. Maximum Maximum Maximum Discharge Maximum Suction Capacity Pressure (Bar) Temperature ( C)** Pressure Specifications Model (LPH) Non-Metallic* Metallic Non-Metallic Metallic (Bar) on Pages: P100 78.0 17 103 60 121 17 12-13 P200 237.4 17 70 60 121 17 14-15 P300 242.1 N/A 173 N/A 121 34 16-17 P400 714.9 17 70 60 121 17 18-19 P500 1255.1 N/A 173 N/A 121 34 20-21 P600 2634.0 17 70 60 121 17 22-23 * 24 bar maximum with Kynar liquid end. ** Consult factory for correct component selection for fluid temperatures above 71 C (160 F). 10

www.hydra-cell.com/metering Multiplexing Capability The simple design of Hydra-Cell enables mixing ratios of multiple fluids in flexible, economical ways. Using only one motor and one gearbox, Hydra-Cell Metering Solutions can provide spare, double-flow, side-by-side systems, or pre-mixed ratios. In fact, pumps utilizing the same gearbox and motor need not be the same model Hydra-Cell pumps. Up to six different fluids can be metered by using different manifold plates, and using special manifolds, a single Hydra-Cell P200 or P300 model can feed up to three systems from one liquid end. Ordinary metering pumps cannot provide the same capability without entailing the full cost of an additional pump. Manifold and valve plate for 2:1 ratio dosing applications In this case, two P100 model pumps driven by one gearbox and one motor can meter two liquids. 11

P100 Pump Series Capacities to 78.01 LPH - Rated to 103 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). Performance* LPH Maximum Flow at Designated Pressure LPH All Pumps LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 17 Bar 35 Bar 70 Bar 103 Bar RPM Ratio RPM 1.99 1.68 1.44 0.76 ** 14.5 100:1 2.50 2.18 1.93 1.23 ** 18.13 80:1 3.39 3.01 2.74 2.01 ** 24.17 60:1 4.01 3.67 3.39 2.64 ** 29 50:1 5.02 4.67 4.36 3.58 ** 36.25 40:1 6.71 6.33 5.99 5.15 1.75 48.33 30:1 1450 8.05 7.65 7.29 6.40 2.98 58 25:1 10.07 9.65 9.24 8.28 4.82 72.5 20:1 13.44 12.97 12.48 11.42 7.89 96.67 15:1 20.18 19.60 18.98 17.69 14.03 145 10:1 26.91 26.24 25.47 23.96 20.16 193.33 7.5:1 40.39 39.52 38.46 36.50 32.43 290 5:1 51.99 50.96 49.65 47.31 43.01 373.3 7.5:1 2800 78.01 76.60 74.73 71.54 66.71 560 5:1 * Capacity data is shown for pumps with elastomeric diaphragms. Consult factory for performance characteristics of pumps with PTFE diaphragms. ** Consult factory for performance specifications. Required Motor kw 0.18 0.37 12

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 1 Flow Control Electronic variable speed drive Maximum Discharge Pressure 103 bar (1500 PSI) Non- Polypropylene- 17 bar (250 PSI) Kynar- 24 bar (350 PSI) Maximum Suction Pressure 17 bar (250 PSI) Maximum Temperature 121 C (250 F)* Non- 60 C (140 F) Suction Port 1/2 inch BSPT or NPT Discharge Port 3/8 inch BSPT or NPT Weight (less motor) 8.4 kg (18.5 lbs) Non- 7.4 kg (16.4 lbs) Dimensions (less motor) 230 mm W x 294 mm D x 150 mm H (9.07" W x 11.57" D x 5.9" H) Non- 230 mm W x 300 mm D x 150 mm H (9.07" W x 11.82" D x 5.9" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). Representative Dimensional Drawings (in mm) For accessories, options, and a system installation example, see pages 24-25. Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 1 0 0 Pump Model Size (Digits 1-4) P100 For all P100 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) M Kynar P S Polyproplylene 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) E EPDM G Viton -XT J PTFE P Neoprene T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C SC 316 SST / Ceramic TC Hastelloy C / Ceramic Gearbox Ratio (Digits 10-12) 100 100:1 (63 B5 Motor Frame) 080 80:1 (63 B5 Motor Frame) 060 60:1 (63 B5 Motor Frame) 050 50:1 (63 B5 Motor Frame) 040 40:1 (63 B5 Motor Frame) 030 30:1 (63 B5 Motor Frame) 025 25:1 (63 B5 Motor Frame) 020 20:1 (63 B5 Motor Frame) 015 15:1 (63 B5 Motor Frame) 010 10:1 (63 B5 Motor Frame) 007 7.5:1 (63 B5 Motor Frame) 005 5:1 (63 B5 Motor Frame) Base Plate (Digit 13) A Aluminum (Epoxy painted) 13

P200 Pump Series Capacities to 237.4 LPH - Rated to 70 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Multiple diaphragm design provides linear, virtually pulse-less flow Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). Performance* LPH Maximum Flow at Designated Pressure LPH All Pumps LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 17 Bar 35 Bar 70 Bar RPM Ratio RPM 4.95 4.57 3.84 2.00 14.5 100:1 6.49 6.11 5.36 3.46 18.13 80:1 9.07 8.67 7.89 5.89 24.17 60:1 11.12 10.72 9.91 7.83 29 50:1 14.21 13.79 12.95 10.75 36.25 40:1 19.36 18.92 18.01 15.61 48.33 30:1 1450 23.48 23.02 22.06 19.50 58 25:1 29.66 29.17 28.14 25.33 72.5 20:1 39.96 39.42 38.27 35.06 96.67 15:1 60.55 59.92 58.52 54.50 145 10:1 81.15 80.41 78.78 73.95 193.33 7.5:1 122.3 121.4 119.3 112.9 290 5:1 157.8 156.7 154.2 146.4 373.3 7.5:1 2800 237.4 235.9 232.4 221.5 560 5:1 * Capacity data is shown for pumps with elastomeric diaphragms. Consult factory for performance characteristics of pumps with PTFE diaphragms. Required Motor kw 0.18 0.37 0.55 0.75 14

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 3 Flow Control Electronic variable speed drive Maximum Discharge Pressure 70 bar (1000 PSI) Non- Polypropylene- 17 bar (250 PSI) Kynar- 24 bar (350 PSI) Maximum Suction Pressure 17 bar (250 PSI) Maximum Temperature 121 C (250 F)* Non- 60 C (140 F) Suction Port 1/2 inch BSPT or NPT Discharge Port 3/8 inch BSPT or NPT Weight (less motor) 17.7 kg (39 lbs) Non- 13.6 kg (30 lbs) Dimensions (less motor) 395 mm W x 311 mm D x 205 mm H (15.56" W x 12.23" D x 8.06" H) Non- 395 mm W x 320 mm D x 205 mm H (15.56" W x 12.61" D x 8.06" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). Representative Dimensional Drawings (in mm) For accessories, options, and a system installation example, see pages 24-25. Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 2 0 0 Pump Model Size (Digits 1-4) P200 For all P200 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) M Kynar P S Polyproplylene 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) E EPDM G Viton -XT J PTFE P Neoprene T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C SC 316 SST / Ceramic TC Hastelloy C / Ceramic Gearbox Ratio (Digits 10-12) 100 100:1 (63 B5 Motor Frame) 080 80:1 (63 B5 Motor Frame) 060 60:1 (63 B5 Motor Frame) 050 50:1 (63 B5 Motor Frame) 040 40:1 (63 B5 Motor Frame) 030 30:1 (63 B5 Motor Frame) 025 25:1 (63 B5 Motor Frame) 020 20:1 (63 B5 Motor Frame) 015 15:1 (63 B5 Motor Frame) 010 10:1 (63 B5 Motor Frame) 007 7.5:1 (63 B5 Motor Frame) 005 5:1 (63 B5 Motor Frame) Base Plate (Digit 13) C Carbon Steel (Epoxy painted) S Stainless Steel 15

P300 Pump Series Capacities to 242.1 LPH - Rated to 173 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Multiple diaphragm design provides linear, virtually pulse-less flow Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). Performance LPH Maximum Flow at Designated Pressure LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 35 Bar 104 Bar 173 Bar RPM Ratio RPM 6.05 5.52 4.24 3.02 14.5 100:1 7.62 7.07 5.72 4.40 18.13 80:1 10.24 9.65 8.18 6.71 24.17 60:1 12.33 11.71 10.14 8.56 29 50:1 15.46 14.80 13.09 11.33 36.25 40:1 20.69 19.95 18.00 15.94 48.33 30:1 1450 24.88 24.07 21.94 19.63 58 25:1 31.15 30.25 27.83 25.17 72.5 20:1 41.61 40.55 37.66 34.41 96.67 15:1 62.53 61.16 57.32 52.87 145 10:1 83.44 81.76 76.97 71.33 193.33 7.5:1 125.3 123.0 116.3 108.3 290 5:1 161.3 158.5 150.2 140.1 373.3 7.5:1 2800 242.1 238.1 226.1 211.4 560 5:1 Required Motor kw 0.18 0.75 0.37 1.1 0.55 1.5 16

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 3 Flow Control Electronic variable speed drive Maximum Discharge Pressure 173 bar (2500 PSI) Maximum Suction Pressure 35 bar (500 PSI) Maximum Temperature 121 C (250 F)* Suction Port 1/2 inch BSPT or NPT Discharge Port 1/2 inch BSPT or NPT Weight (less motor) 23.2 kg (51 lbs) Dimensions (less motor)** 407 mm W x 311 mm D x 244 mm H (16.02" W x 12.23" D x 9.60" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). ** For 63 B5 motor frame only. Consult factory for other motor frame sizes. Representative Dimensional Drawings (in mm) Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 3 0 0 Pump Model Size (Digits 1-4) P300 For all P300 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) R 304 Stainless Steel S 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) G Viton -XT T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C Gearbox Ratio (Digits 10-12) 100 100:1 (63 B5 Motor Frame) 080 80:1 (63 B5 Motor Frame) 060 60:1 (63 B5 Motor Frame) 050 50:1 (63 B5 Motor Frame) 040 40:1 (63 B5 Motor Frame) A30 30:1 (71 B5 Motor Frame) A25 25:1 (71 B5 Motor Frame) A20 20:1 (71 B5 Motor Frame) A15 15:1 (71 B5 Motor Frame) A10 10:1 (71 B5 Motor Frame) A07 7.5:1 (71 B5 Motor Frame) B05 5:1 (80 B5 Motor Frame) Base Plate (Digit 13) C Carbon Steel (Epoxy painted) S Stainless Steel For accessories, options, and a system installation example, see pages 24-25. 17

P400 Pump Series Capacities to 714.9 LPH - Rated to 70 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Multiple diaphragm design provides linear, virtually pulse-less flow Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). Performance* LPH Maximum Flow at Designated Pressure LPH All Pumps LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 17 Bar 35 Bar 70 Bar RPM Ratio RPM 16.15 15.97 15.79 15.25 14.5 100:1 20.80 20.61 20.41 19.81 18.13 80:1 28.53 28.33 28.10 27.38 24.17 60:1 34.72 34.50 34.25 33.43 29 50:1 44.01 43.77 43.48 42.52 36.25 40:1 59.48 59.22 58.85 57.67 48.33 30:1 1450 71.87 71.58 71.16 69.79 58 25:1 90.44 90.12 89.62 87.97 72.5 20:1 121.40 121.0 120.4 118.3 96.67 15:1 183.3 182.8 181.9 178.9 145 10:1 245.2 244.6 243.4 239.5 193.33 7.5:1 369.0 368.2 366.5 360.7 290 5:1 475.7 474.7 472.5 465.1 373.3 7.5:1 2800 714.9 713.4 710.2 699.2 560 5:1 * Capacity data is shown for pumps with elastomeric diaphragms. Consult factory for performance characteristics of pumps with PTFE diaphragms. Required Motor kw 0.18 0.37 0.55 0.75 1.1 1.5 2.2 18

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 3 Flow Control Electronic variable speed drive Maximum Discharge Pressure 70 bar (1000 PSI) Non- Polypropylene- 17 bar (250 PSI) Kynar- 24 bar (350 PSI) Maximum Suction Pressure 17 bar (250 PSI) Maximum Temperature 121 C (250 F)* Non- 60 C (140 F) Suction Port 1 inch BSPT or NPT Discharge Port 3/4 inch BSPT or NPT Weight (less motor) 28.1 kg (62 lbs) Non- 22.2 kg (49 lbs) Dimensions (less motor)** 447 mm W x 251 mm D x 263 mm H (17.59" W x 9.87" D x 10.34" H) Non- 462 mm W x 251 mm D x 263 mm H (18.19" W x 9.87" D x 10.34" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). ** For 63 B5 motor frame only. Consult factory for other motor frame sizes. Representative Dimensional Drawings (in mm) For accessories, options, and a system installation example, see pages 24-25. Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 4 0 0 Pump Model Size (Digits 1-4) P400 For all P400 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) C Cast Iron M Kynar P S Polypropylene 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) E EPDM G Viton -XT J PTFE P Neoprene T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C SC 316 SST / Ceramic TC Hastelloy C / Ceramic Gearbox Ratio (Digits 10-12) 100 100:1 (63 B5 Motor Frame) 080 80:1 (63 B5 Motor Frame) 060 60:1 (63 B5 Motor Frame) 050 50:1 (63 B5 Motor Frame) 040 40:1 (63 B5 Motor Frame) A30 30:1 (71 B5 Motor Frame) A25 25:1 (71 B5 Motor Frame) A20 20:1 (71 B5 Motor Frame) A15 15:1 (71 B5 Motor Frame) A10 10:1 (71 B5 Motor Frame) A07 7.5:1 (71 B5 Motor Frame) A05 5:1 (71 B5 Motor Frame) B05 5:1 (80 B5 Motor Frame) Base Plate (Digit 13) C Carbon Steel (Epoxy painted) S Stainless Steel 19

P500 Pump Series Capacities to 1255.1 LPH - Rated to 173 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Multiple diaphragm design provides linear, virtually pulse-less flow Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). Performance LPH Maximum Flow at Designated Pressure LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 35 Bar 104 Bar 173 Bar RPM Ratio RPM 36.60 34.90 31.32 28.70 14.5 100:1 44.71 42.93 39.07 36.10 18.13 80:1 58.20 56.28 51.98 48.40 24.17 60:1 68.99 66.96 62.30 58.23 29 50:1 85.19 82.99 77.79 73.00 36.25 40:1 112.2 109.7 103.6 97.60 48.33 30:1 1450 133.8 131.1 124.3 117.3 58 25:1 166.2 163.1 155.2 146.8 72.5 20:1 220.2 216.6 206.9 196.1 96.67 15:1 328.1 323.4 310.1 294.5 145 10:1 436.1 430.3 413.4 392.9 193.33 7.5:1 652.0 644.1 619.9 589.8 290 5:1 838.1 828.2 797.9 759.4 373.3 7.5:1 2800 1255.1 1241.0 1196.8 1139.6 560 5:1 Required Motor kw 0.18 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 20

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 5 Flow Control Electronic variable speed drive Maximum Discharge Pressure 173 bar (2500 PSI) Maximum Suction Pressure 35 bar (500 PSI) Maximum Temperature 121 C (250 F)* Suction Port 1-1/4 inch BSPT or NPT Discharge Port 3/4 inch BSPT or NPT Weight (less motor) 72.6 kg (160 lbs) Dimensions (less motor)** 488 mm W x 272 mm D x 315 mm H (19.2" W x 10.7" D x 12.4" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). ** For 71 B5 motor frame only. Consult factory for other motor frame sizes. Representative Dimensional Drawings (in mm) For accessories, options, and a system installation example, see pages 24-25. Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 5 0 0 Pump Model Size (Digits 1-4) P500 For all P500 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) S 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) G Viton -XT T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C Gearbox Ratio (Digits 10-12) A00 100:1 (71 B5 Motor Frame) A80 80:1 (71 B5 Motor Frame) A60 60:1 (71 B5 Motor Frame) A50 50:1 (71 B5 Motor Frame) A40 40:1 (71 B5 Motor Frame) B30 30:1 (80 B5 Motor Frame) B25 25:1 (80 B5 Motor Frame) B20 20:1 (80 B5 Motor Frame) B15 15:1 (80 B5 Motor Frame) B10 10:1 (80 B5 Motor Frame) B07 7.5:1 (80 B5 Motor Frame) C07 7.5:1 (90 B5 Motor Frame) D07 7.5:1 (100/112 B5 Motor Frame) A05 5:1 (71 B5 Motor Frame) B05 5:1 (80 B5 Motor Frame) C05 5:1 (90 B5 Motor Frame) D05 5:1 (100/112 B5 Motor Frame) Base Plate (Digit 13) A Aluminum (Epoxy painted) H Carbon Steel (Epoxy painted) for D reducers 21

P600 Pump Series Capacities to 2634.0 LPH - Rated to 70 Bar Electronic Precision Metering Designed to handle a wide range of fluids from clear water to thick slurries Electronic flow control increases accuracy and reliability Multiple diaphragm design provides linear, virtually pulse-less flow Smaller footprint saves valuable space One pump covers a wide range of flows and pressures - reducing inventory requirements with fast, simple field conversion Duplexing option doubles capacity and equipment savings Hydraulically-actuated, balanced diaphragms provide superior performance across entire pressure range Rugged construction with a variety of affordable choices for liquid end, diaphragm and check valve materials Performance* LPH Maximum Flow at Designated Pressure Hydra-Cell Metering Solutions meet or exceed API 675 performance standards for Steady-State Accuracy (±1%), Linearity (±3%), and Repeatability (±3%). LPH All Pumps LPH Metallic Pump Heads Only Pump Gear Motor 7 Bar 17 Bar 35 Bar 70 Bar RPM Ratio RPM 68.14 68.04 66.92 63.09 14.5 100:1 85.53 84.90 83.47 79.20 18.13 80:1 113.9 113.0 111.0 106.0 24.17 60:1 136.7 135.4 133.0 127.4 29 50:1 170.8 169.0 166.1 159.6 36.25 40:1 227.6 225.1 221.1 213.2 48.33 30:1 1450 273.0 270.0 265.2 256.1 58 25:1 341.2 337.4 331.3 320.5 72.5 20:1 454.9 449.6 441.4 427.7 96.67 15:1 682.2 674.0 661.7 642.2 145 10:1 909.5 898.4 882.0 856.7 193.33 7.5:1 1364.1 1347.3 1322.6 1285.7 290 5:1 2800 1755.9 1734.1 1702.2 1655.3 373.3 7.5:1 2634.0 2601.0 2553.1 2483.8 560 5:1 * Capacity data is shown for pumps with elastomeric diaphragms. Consult factory for performance characteristics of pumps with PTFE diaphragms. Required Motor kw 0.18 0.37 0.55 0.75 1.1 1.5 2.2 3.7 5.5 7.5 22

www.hydra-cell.com/metering Pump Data Diaphragms per Liquid End 3 Flow Control Electronic variable speed drive Maximum Discharge Pressure 70 bar (1000 PSI) Non- Polypropylene- 17 bar (250 PSI) Kynar- 24 bar (350 PSI) Maximum Suction Pressure 17 bar (250 PSI) Maximum Temperature 121 C (250 F)* Non- 60 C (140 F) Suction Port 1-1/2 inch BSPT or NPT Discharge Port 1 inch BSPT or NPT Weight (less motor) 64 kg (141 lbs) Non- 48 kg (106 lbs) Dimensions (less motor)** 533 mm W x 272 mm D x 285 mm H (21.0" W x 10.7" D x 11.2" H) Non- 554 mm W x 272 mm D x 285 mm H (21.8" W x 10.7" D x 11.2" H) *Consult factory for correct component selection for fluid temperatures above 71 C (160 F). ** For 71 B5 motor frame only. Consult factory for other motor frame sizes. Representative Dimensional Drawings (in mm) For accessories, options, and a system installation example, see pages 24-25. Pump Ordering Information A complete pump order number contains 13 digits based on the specified pump materials listed below. Contact your Hydra- Cell sales representative for accompanying motor drive options. 1 2 3 4 5 6 7 8 9 10 11 12 13 P 6 0 0 Pump Model Size (Digits 1-4) P600 For all P600 Pumps Pump Version (Digit 5) M BSPT Ports N NPT Ports Pump Head Material (Digit 6) C Cast Iron M Kynar P S Polypropylene 316 Stainless Steel T Hastelloy C Diaphragm & O-ring Material (Digit 7) E EPDM G Viton -XT J PTFE P Neoprene T Buna-N-XS Check Valve Material (Digits 8-9) (Valve Spring / Valve & Seat) SS 316 SST / 316 SST TT Hastelloy C / Hastelloy C SC 316 SST / Ceramic TC Hastelloy C / Ceramic Gearbox Ratio (Digits 10-12) A00 100:1 (71 B5 Motor Frame) A80 80:1 (71 B5 Motor Frame) A60 60:1 (71 B5 Motor Frame) A50 50:1 (71 B5 Motor Frame) A40 40:1 (71 B5 Motor Frame) B30 30:1 (80 B5 Motor Frame) B25 25:1 (80 B5 Motor Frame) B20 20:1 (80 B5 Motor Frame) B15 15:1 (80 B5 Motor Frame) B10 10:1 (80 B5 Motor Frame) B07 7.5:1 (80 B5 Motor Frame) C07 7.5:1 (90 B5 Motor Frame) D07 7.5:1 (100/112 B5 Motor Frame) A05 5:1 (71 B5 Motor Frame) B05 5:1 (80 B5 Motor Frame) C05 5:1 (90 B5 Motor Frame) D05 5:1 (100/112 B5 Motor Frame) Base Plate (Digit 13) C Carbon Steel (Epoxy painted) H Carbon Steel (Epoxy painted) for D reducers 23

Hydra-Cell System Options & Accessories System Installation Example Hydra-Cell pumps are just one facet of a complete Hydra-Cell Metering Solutions system.we can furnish all components in your pumping system, individually tailored to your specific processing needs. For complete details, contact Hydra-Cell, your Hydra-Cell sales representative, or Hydra-Cell distributor. Calibration Cylinders Back Pressure Valves Pressure Relief Valves Pulsation Dampeners Motors - Motor Adapters - VFDs - Controllers Diaphragm Materials Liquid End & Check Valve Materials Gearbox Ratios Manifolds & Flanges Strainers Suction Accumulators Actuating Oils Witnessed & Non-Witnessed Testing Drawing Packages OEM Paint & Nameplate Customisation 24

www.hydra-cell.com/metering Motor Adapters - VFDs - Controllers - Motors Custom Motor Controller Variety of Diaphragm Materials Metallic or Non-Metallic Liquid End & Check Valve Materials Pulsation Dampeners OEM Paint & Nameplate Customisation Available Pressure Relief & Back Pressure Valves Different Gearbox Ratios PVC or Glass Calibration Cylinders 25

Hydra-Cell Bare Shaft Pumps for Metering metering pumps, as they meet or exceed API 675 performance standards at the rated RPMs outlined in the table below. Hydra-Cell bare shaft pumps should be considered instead of a Hydra-Cell Metering Solutions system when any of the following conditions apply: In certain dosing applications, Hydra-Cell pumps without the gear reducers (bare shaft pumps) are an ideal alternative to Flow capacities required exceed those of Hydra-Cell Metering Solutions pumps (see page 10) Space or application parameters dictate the use of direct or belt drives Acquisition cost is the primary consideration Capacities & Ratings Maximum Maximum Maximum Discharge Maximum Suction Rated Capacity Pressure (BAR) Temperature ( C) Pressure RPM for Model* (LPH) Non-Metallic Metallic Non-Metallic Metallic (BAR) Metering G20 138.5 17 103 82 121 17 1050 G03 588.3 17 70 82 121 17 1440 G04 593.0 N/A 173 N/A 121 34 1440 G10 1862.4 17 70 82 121 17 1440 G15 3077.5 N/A 173 N/A 121 34 1440 G25 4837.8 17 70 82 121 17 1050 G35 8630.7 17 83 82 121 17 1050 * Ratings are for X-Cam design 207 Bar 173 138 103 70 G20 G03 G04 G10 G15 G25 G35 34 0 0 380 760 1140 1520 1900 2280 2660 3040 3420 3800 4180 4560 4940 5320 5700 6080 6460 6840 LPH 7220 7600 7980 8360 8740 26

Hydra-Cell Worldwide Sales & Service www.hydra-cell.com/metering Hydra-Cell pumps are sold and serviced worldwide by a comprehensive network of factory-trained pump distributors located in more than 40 countries. As specialists in pump technologies, our distributor organisations offer you a vital local resource for technical expertise, product training, sales and service. Contact us for the distributor location nearest you. Argentina Australia Austria Belgium Brazil Canada China Czech Republic Denmark Finland France Germany Greece Hong Kong Hungary Iceland India Indonesia Ireland Italy Japan Korea Latvia Lithuania Malaysia Mexico The Netherlands New Zealand Norway Pakistan Poland Portugal Puerto Rico Romania Singapore Slovakia South Africa Spain Sweden Switzerland Taiwan Thailand Turkey United Kingdom United States Uruguay Venezuela Vietnam 27

Units 8 & 9, Fleet Business Park Sandy Lane Church Crookham, Hampshire GU52 8BF, England Tel: +(44) 01252 816847 FAX Tel: +(44) 01252 629242 Email: sales@wannerint.com www.wannerint.com Wanner Pumps Ltd. Room 1111, 11/F New Kowloon Plaza 38 Tai Kak Tsui Road Tai Kak Tsui, Kowloon, HONG KONG Tel: (852) 3428 6534 FAX Tel: (852) 3188 9145 Email: jloo@wannereng.com 1204 Chestnut Avenue Minneapolis, MN 55403 USA Tel: 612-332-5681 FAX Tel: 612-332-6937 Toll-Free Fax (USA): 800-332-6812 Email: sales@wannereng.com www.hydra-cell.com/metering