Fuse state indicator MEg72. User manual

Similar documents
Uninterruptible power supply Supply MEg101.4

Output Feeder Monitor Set MEg71

Product Data Sheet. Damper Interface. Features

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

Installation Instructions & Users Manual

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Level Measuring Sensor for Diesel Fuel Tanks

English. Instruction and operation manual S 110. Power Meter

Electronic Ballast EVG 2000-T

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

RT2DB Excitation and voltage regulation system for synchronous generators

User Manual Solar Charge Controller 3KW

Operation Instructions

Emergency lighting units EM powerled

DC Master 24/ A

User Manual. Solar Charge Controller 3KW

Electronic Circuit Breaker ESS20-0..

Emergency lighting units EM series

Emergency lighting units EM powerled

BM kv Digital Insulation Tester USER MANUAL

INDUS rail /

My Reserve 500 Install Guide

FIREMAN'S MICROPHONE POWER SUPPLY FOR THE VOICE ALARM SYSTEMS 24V

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

VAPORIX-PCM. Technical Documentation. Corrective control module for connection to VAPORIX-Control. Version: 3 Edition: Art.

i-energy i-micro inverter GT260

User Manual Digital Water Level Indicator for rain water storage tanks

Electronic Circuit Breaker ESS20

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

INTECH Micro 2300-RTD6

Emergency lighting units EM powerled

Technical Datasheet. Compact DC Energy Meter. Multi-Function DC Energy Meter

AWZ 200. AWZ 13,8V/2A/7Ah/L

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

CRE, CRIE, CRNE CRKE, SPKE, MTRE, CHIE 1 & 3 phase

LUBRICATION PUMP PMP CENTRAL LUBRICATION

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

IES GRID FEED-IN LIMITER

Electronic tank monitoring device (complete kit) - for battery tanks - incl. overfill safety - after TRwS 791(-2) with clearance display

EPAS Desktop Pro Software User Manual

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

PURE SINE WAVE DC TO AC POWER INVERTER

Manual for Inverter system type PCI05

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

ThunderION. Static Neutralising System. GB User's Manual 2

User Manual. SP10000 Premium

Service instructions. MAGNA Series 2000

Solid Dielectric, Single Phase Recloser

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

Self-Testing Industrial Series

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

POE1824B. PoE 27,6V/4x0,4A/2x7Ah/PoE

ECONOMISER SERIES E2T USER MANUAL

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Accessories for Stand-alone inverter SUNNY ISLAND GENMAN

Operating Instructions. Angle Seat Control Valve. Type 7020

Emergency lighting units EM converterled. EM converterled PRO 200 V PRO series

9200 Revenue Meter. Model Certification Current Inputs. Complies with the accuracy requirements of the ANSI C Revenue Metering Standard

PSU-S-12V/L-1A/5/FTA/PTC-TR-MC AWZ v.1.0

SLIM LIGHT SERIES FOR NON MAINTAINED / MAINTAINED LUMINAIRE

Emergency lighting units EM converterled. EM converterled PRO 50 V PRO series

DC POWER SUPPLY SYSTEMS

Tester for Motor-Driven Relays Type Siemens SICO 1225 M A N U A L

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Product card User manual. KP Strong Safe

Application Engineering Europe

Manual. EN Appendix. Lynx Ion BMS 400A / 1000A

AUTOMATIC STANDBY ACTIVATION. Operation Manual

Installation Instructions

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

LED Driver Linear / area dimming industry. Driver LC 150W mA IND sl EXC EXCITE series

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

MERU Solar Off-Grid Inverters

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Operating Instructions Operating Instructions. HEKA testing lane UNIVERS "TX" 4cm above floor

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Issue 2.0 December EPAS Midi User Manual EPAS35

OPEN/CLOSE SERVICE ELECTRIC ACTUATORS OPERATION AND MAINTENANCE MANUAL COMMERCIAL AND INDUSTRIAL VALVES AND AUTOMATION

LEAD ACID BATTERY CHARGER

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

Spectron Industrial Series

Guidance to Installers of Viridian EV Charging Stations

Capacitive level sensors CLS 23

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

PSU-S-12V/L-3A/9/FTA/PTC-TR-MC AWZ v.1.0

English. Instruction and operation manual S 212. Dew point sensor

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Installation manual wall-mounted distributor

Silvertel. Ag Features. Multi-Stage Charging. Battery Reversal Protection. Reduced Power Consumption. Wide DC or AC Input Voltage Range

ORVALDI Solar Infini 5kW

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Table of Contents. Timer Identification Timer ID BLU-U Features: 1K 6K BLU-U Features 1K 6K

Transcription:

Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic

Fuse state indicator MEg72 User manual Fuse state indicator MEg72 INTRODUCTION The fuse state indicator MEg72 is used for local and remote indication of the knife-bladecontact fuse in LV grids. It enables identification of the states of fuses also in parallel power supplied LV networks, LV mesh networks or in LV networks with distributed generation. The state of the fuse is represented by a two-coloured LED, the state of a galvanically separated contact of a polarized relay and for remote connection the indicators are equipped with a RS485 interface with a MODBUS protocol. The indicator consists of a plastic body with slide-in contacts. Side contacts are screwed to the plastic housing for side mounting to a load-break switch rail. The indicator houses a covered terminal board for connecting cables. The MEg72 indicator meets the requirements of overvoltage category CT IV / 300 V; it can be installed in all points of LV networks, including distribution transformer substations. Function description The MEg72 fuse state indicator measures the voltage in front and behind the fuse and statistically evaluates their difference, based on which it will determine the state of the fuse on which it is installed. The power supply of indicator requires of 12 V DC. The good or unbroken / faulty state of the fuse can be seen on the two-coloured OK/ERR LED, it is also signalized by the galvanic free contact of the polarized relay and it is remotely transferred using a RS485 interface with MODBUS protocol. fter connection to power supply the LED changes from green light to red, until the state of the fuse is evaluated. In case that the voltages on both sides of the fuse are insufficient for evaluation, LED continues to change from green to red. The unbroken fuse is indicated with a short repeated pulse of the green LED for 2 sec, the broken fuse is indicated with a shortly interrupted continuous light of the red LED for 2 sec. The short 3

Měřící Energetické paráty interruptions of LED light also inform the operator that the processor is functioning correctly. fter installation of new fuse, the transition of the red interrupted light to the green interrupted light has a delay of approx. 30 sec. If the voltages on both ends of the fuse drop under 60 % U n, the short interruptions of the green or red light is prolonged and duty cycle of the light has a frequency of 1:1. In case that 12 V DC is not available, the LED is switch off. Other LED lights combination of signalling means an error of the MEg72 indicator. n open contact of relay signalizes an unbroken fuse and closed relay contact signalizes an error in the fuse. The relay switches from open to closed with a delay of approx. 2 sec after an error appears in the fuse and the switch from closed to open is delayed by approx. 30 sec after the fuse is reconnected. The state of the polarized relay remains the same in case its power supply is interrupted. In case when the state of the fuse changes during the time the power supply is interrupted, the contact of the polarized relay is set to the corresponding state after its power supply has been renewed and the state of the fuse has been evaluated. When communicating via MODBUS and with a connected power supply the following states of the fuse indicator are used: unbroken fuse; the state of the fuse cannot be evaluated (both measure voltages are below 60 % U n ), the last evaluated state was unbroken fuse; faulty fuse; the state of the fuse cannot be evaluated (both measure voltages are below 60 % U n ), the last evaluated state was faulty fuse; the state of the fuse is being evaluated after its replacement, this takes approx. 1.5 minutes; the state of the fuse is being evaluated after the power supply has been reconnected, it takes approx. 30 sec; the change of the state of a fuse from unbroken to faulty or vice versa, this transitive state is signalized until the first reading of the fuse state. 4

Fuse state indicator MEg72 User manual Technical parameters The MEg72 fuse state indicator may be used in TN networks. The MEg72 fuse state indicator is designed for PN or PN types of knife-blade-contact fuses with ratings 1(01), 1, 2(02), 2, 3(03) and 3. Nominal voltage U n : Nominal frequency f n : Indication range: Rated voltage of power supply: Rated current of power supply: Range of supply voltage: Galvanically isolated communication: Communication protocol: default settings: Maximum voltage on relay contacts: Relay contact maximum current: 230 V 50 Hz 60 % U n to 120 % U n (at least one voltage) 12 V DC 30 m DC 9 V DC to 15 V DC RS485 MODBUS 115.2 kbit/sec, 8 bit, no parity, one stop bit 30 V DC, 30 V C 1 Diameter of conductor in spring terminals: 0.2 mm 2 to 0.75 mm 2 Maximum diameter of the power supply and communication cable: Unit dimensions: Unit dimensions with side contacts: 5.0 mm 84 63 10.5 mm 84 63 49 mm Operation temperature range: -25 C to +55 C Storage temperature range: -40 C to +70 C verage relative humidity within 24 hours: up to 95 % Protection rating: Overvoltage category: IP00 (placement on LV fuses) CT IV / 300 V EMC: EN 61326-1:2013 5

Měřící Energetické paráty Design and connection Operation, processing and communication circuits of the MEg72 indicator are located in a plastic housing filled with an impregnation substance, which ensures a long-term operating life of the indicator even in challenging LV environments in fuse boxes. The surface of the created compact unit is insulated. The MEg72 indicator has a label stating standard information, next to it is a white field to enter rated current values of a fuse with an installed indicator, see Fig. 1. Fig. 1: Indicator label with a white field to enter rated current values of a connected fuse. 00000 www.e-mega.cz 72 CT IV/300V IP 00 Supply 12V/30m OK ERR I poj The indicator has flexible contacts connected through resistors located in its profiled openings, enabling it to slide onto to shaped parts of a fuse intended for handling. In this front view, the LED signalization OK/ERR can be seen on the light tube, see Fig. 2. When installing the indicator on fuses located on a load-break switch rail, which uses the shaped parts of the fuses for their removal, the MEg72 indicators are placed at the side of the fuses. Side fuses are used for side connections and are screwed onto the indicator housing using four screws, see Fig. 3. In this front view, the LED signalization OK/ERR can be seen on the side wall of the light tube. The side placement of indicators can only be allowed in load-break switch rails, installed on pulled out fuses and not energised, see Fig. 4. 6

Fuse state indicator MEg72 User manual Fig. 2: MEg72 indicator in its basic design for front mounting 10,5 3 2 1 4 5 62 82 Pos. 1 Terminal box housing Pos. 2 Light tube Pos. 3 M3 8 screw, countersunk, plastic, 2 pieces Pos. 4 Openings for fuse Pos. 5 Opening for cable Fig. 3: Indicator MEg72 with added side contacts for installation on the side of fuses 49 1 Pos. 1 M2.5 6 screw countersunk 4 pcs 7

Měřící Energetické paráty Fig. 4: Installation of MEg72 indicator onto fuses in a load-break switch rail 1 5 4 2 3 6 Pos. 1 Swing-out part of load-break switch rail with fuses Pos. 2 Core part of load-break switch rail Pos. 3 Placement of cables around swivel Pos. 4 Sliding indicator onto knife-blade contacts Pos. 5 To power source and communication unit Pos. 6 Orientation of side light tube The MEg72 has a covered terminal strip with spring terminals for connecting the power supply voltage, remote control and local signalization, see. Fig. 5. It also shows the installation of several MEg72 indicators on fuses. The +12 V power supply voltage and a common conductor of the power supply voltage and the voltage measuring circuit are connected to terminal X4 which is connected to terminal X3 in the indicator, the power supply is then connected to the neighbouring indicators. MEg101.5 power source, overvoltage category CT IV can be used with supercapacitors to provide a power supply even during short-term interruptions of the power supply from the mains. Voltage on fuse contacts is done against a mutual conductor, which must be grounded! The power source must have its output voltage galvanically free or it must be grounded on a negative pole. The contact of the polarized signalization relay of the indicator with and poles is attached to connected terminals X7 and X8. Connecting the indicator contacts, see Fig. 5, the fault of any of the fuses is signalized by connecting output terminals S1 and S2. 8

Fuse state indicator MEg72 User manual Fig. 5: MEg72 indicator connection for local signalization Fuse 1 MEg72 Fuse 2 MEg101.5 230V/50Hz mains power supply U0 U1 U0 U1 U0 MEg72 X4 X3 X4 X3 B B X8 X7 X6 X5 U1 Fuse N MEg72 X4 X3 B B X8 X7 X6 X5 B B X8 X7 X6 X5 S1 open - OK S2 closed - ERR Detail of MEg72 internal terminal connection X8 B X4 X6 X3 B X5 X7 T N L Note: The connection of and contacts of terminals X7 and X8 is located in the inside layer of the circuit board under terminals X5 and X6. 9

Měřící Energetické paráty Fig. 6: MEg72 indicator connection for remote communication Fuse 2 U0 U1 U0 U1 Fuse N MEg72 X4 X3 B B X8 X7 X6 X5 OUT22 OUT21 T U1 U0 MEg72 X4 X3 B B X8 X7 X6 X5 IN1 IN2 IN3 IN4 IN5 OUT11 OUT12 T MEg202.3 NTENN 2 B2 2 1 T 1 B1 2 T 1 230V/50Hz mains power supply Fuse 1 MEg72 X4 X3 B B X8 X7 X6 X5 KU + + - KU MEg101.4 STOP L N 10

Fuse state indicator MEg72 User manual In case of remote communication of the MEg72 indicator, see Fig. 6, e.g. a MEg101.4 secure power source (overvoltage category CT IV) with a 12 V external accumulator is used. This power supply supplies power to the MEg72 indicators and to the MEg202.3 GSM communication unit with GPRS data transfer. This ensures that even without a mains power supply, the remote transfer of information regarding fuse states is not interrupted. The serial communication interface RS485 of individual MEg72 indicators with and B contacts is connected to the mutual terminals X5 and X6. The MODBUS protocol ensures the communication between individual indicators and detects the state of individual fuses and indicators. MEg72 indicator installation The MEg72 fuse state indicators can be installed on knife-blade fuses in cabinets with classic fuse bottoms, in cabinets with fuse rails and even in cabinets with load-break switch rails. We further on differentiate between installations with LED indications, local signalization and remote communication of fuse states. 1. Individual cable lengths are selected depending on the distance between the centres of the fuses, this enables shifting the indicator away, not needing to disassemble it, Note 1) when a fuse needs replacement. 2. Cables are on both ends, in a length of approx. 25 mm, opened and in case of wires, crimp terminals with a diameter of 0.25 mm 2 with a length of 7 to 9 mm are used. 3. Depending on the fuses stacked next to each other, the rated current values of the fuses are permanently written (permanent marker) into the white field of a relevant indicator. 4. fter unscrewing the screws, the covers of the terminal strips are removed. 5. The +12 V power supply conductor and the mutual of the input and output cable are connected to the spring terminals X3 and X4, see Fig. 5. Note 1: It is necessary to use a cable with a maximum diameter of 5.00 mm and insulation suitable for installation into a LV cabinet, when installing an indicator. The diameter of a conductor that can be inserted into a spring terminal is 0.22 mm 2 to 0.75 mm 2. The indicator manufacturer uses a TBVFS 4 0.22 cable, which stays flexible during temperatures below zero, with a testing voltage of 5.4 kv (CT IV) and four wire conductors, which are equipped with crimp terminals enabling connection into indicator spring terminals. 11

Měřící Energetické paráty 6. Two more cable conductors are installed depending on the type of connection. They are inserted in to terminals X7 and X8 for local signalization, see Fig. 5. They are inserted in to terminals X5 and X6 for remote communication, see Fig. 6. If it is necessary, the MEg72 indicator can also be used for local signalization as well as for remote communication. It is necessary to use a cable with six conductors. 7. The terminal strips with connected input and output cables are covered with covers with light tubes, which will properly secure the cable against accidental removal once tightly screwed in. 8. The power supply conductors (+12 V, ) of the first cable of the indicators connected behind each other must be connected to a switched off 12 V DC power supply. Signalization or communication conductors must be connected to terminals of the signalization unit or the communication unit, see Fig. 5 or Fig. 6. 9. Using all safety measures necessary for work with live wires as well as with personal safety items, interconnected indicators are mounted onto the fuses. a) Installation of indicators in fuse cabinets with classic fuse bottoms and in cabinets with fuse rails is done by sliding the indicator onto the profiled part of the fuse. b) Before mounting indicators onto the side of fuses in a cabinet with load-break switch rails, each indicator must be equipped with a screw-on slide contact, in order for the indicator to slide onto the fuse from the bottom, so it is possible to see, from the top, the side of the light tube LED status OK/ERR. The indicators are installed onto fuses located in the cover of the load-break switch rail. Connecting cables between individual indicators are installed between sections in the area of the swivel, see Fig. 4. The cover of the load-break switch rail with fuses and installed indicators is returned to its working position. 10. The 12 V power supply is switched on. The LEDs OK/ERR will first light up and rapidly change from red to green and after approx. 30 seconds, it will change to a green, shortly interrupted, light. 11. If all fuses are OK and a local signalization option has been chosen, contacts S1 and S2 remain disconnected. 12. The communication of the MEg72 indicators can be verified using a PC with a RS485 interface and a MERCI communication program or a program that is able to work with MODBUS instructions. 12

Fuse state indicator MEg72 User manual Removing the MEg72 indicator The indicator may only be removed by qualified persons using safety equipment for working with live devices and persons with protective and work equipment and tools.. Replacing a fuse in a classic fuse bottom or fuse rail 1. The MEg72 indicator installed on a knife-blade fuse located in a classic fuse bottom or fuse rail is removed from the fuse. It will remain connected to the input and output cable. 2. The indicator is pulled aside the knife-blade fuse and the fuse is replaced. When replacing a fuse with a new fuse with a different rated current value, such new value must be entered into the white field on the indicator label. 3. Using personal protective and work equipment and tools a qualified person will slide the MEg72 indicator onto the profiled part of the fuse. B. Replacing fuses in the load-break switch rail 1. Opened cover of the load-break switch rail with connected fuses and installed MEg72 indicators. 2. Removal of indicator from knife-blade contacts of a replaced fuse. When replacing a fuse with a new fuse with a different rated current value, such new value must be entered into the white field on the indicator label. 3. Sliding an indicator onto the knife-blade contacts of a newly installed fuse in the load-break switch rail. 4. Placement of connection cables into the area around the swivels and returning the load-break switch rail cover into its operation position. C. Exchanging a faulty indicator 1. Switch off the 12 V direct current power supply. 2. Using personal protective equipment, remove defect indicator or several neighbouring indicators, if necessary, from the fuses and place the defect indicator into an area outside of the dangerous voltage area. 3. Disassemble the cover with the light tube of the defect indicator as well as of the new indicator. 4. Using a narrow screwdriver or loosening fixture, remove the conductors of the input and output cable from the terminals of the defect indicator. 13

Měřící Energetické paráty 5. Connect the conductors of the input and output cable into the correct terminals of the new indicator. 6. Properly tighten cover with light tube of the new indicator and verify the strength of the mechanical connection of the input and output cable. 7. Install the new indicator, or the neighbouring indicators, if removed, in the manner described above back onto the correct fuse. 8. The defect MEg72 indicator must be disposed of according to local rules for electrical waste disposal, after its warranty expires. Defect indicators with a valid warranty are subject to conditions described in the article Warranty. MODBUS protocol instruction of MEg72 indicators The MODBUS protocol used in MEg72 indicators is described in detail in the MODBUS protocol implementation in MEg, devices, see www.e-mega.cz. The MEg72 uses these MODBUS functions: 0x03 reading and preserving registers 0x04 reading MEg72 input registers 0x06 entry into preserved registers ddresses of preserved registers 4 Device address 5 Baudrate/100 6 Parity 7 MODBUS MEg version ddress of MEg72 input registers 0 Device Type = 72 1 Firmware version 2 Serial number 3 Serial number group (expansion) 50 Status word of fuse 14

Fuse state indicator MEg72 User manual The state word of a fuse is represented by a bit structure that besides informing about the state of the fuse, also describes the evaluation status. The bits in the status word have the following meaning: D0 1 = Unbroken fuse D1 1 = Previous status unbroken fuse internal status, where due to an interruption of power supply, it is not possible to evaluate the immediate status. D2 1 = Faulty fuse D3 1 = Previous status faulty fuse internal status, where due to an interruption of power supply, it is not possible to evaluate the immediate status. D4 1 = Undefined status after switching on the MEg72 power supply and there is no voltage on the fuse. D5 1 = Probably unbroken fuse internal status, when a defect fuse, based on a protection element against entering an unbroken fuse state, the fuse enters an approx. 70 second monitoring period. If the fuse is evaluated as unbroken fuse during the entire monitoring period, it is switched to an unbroken fuse state, after the monitoring period ends. D6 not used D7 1 = Change. Signalization of a fuse status change from unbroken fuse to faulty fuse and vice versa. The bit is automatically cancelled after reading the status word. This makes it possible for superior systems to easily monitor status changes. 15

Měřící Energetické paráty The MERCI program used to evaluate statuses of MEg72 indicators The evaluation of a MEg72 indicator fuse status is displayed in the right bottom corner with a background colour of the given phase. The number of indicators does not always have to correspond to the number of phases (in this case two indicators are installed on phases L1, L2). The MDT file does not record periodical data, but only asynchronous events that are created when a fuse changes its status. red background indicates a defect fuse, a green background indicates an OK fuse and a grey background indicates that it is not possible to identify the state of the fuse. The red background of a container indicates that the indicator is not communicating, see Fig. 7. Fig. 7: Example of fuse status display 16

Fuse state indicator MEg72 User manual List of MEg72 indicator components 1 pc MEg72 indicator 2 pcs of side, slide-on contacts with 4 pcs of screws with cheese head M2,5 4 mm 1 pc warranty certificate with final inspection record 1 pc CD with description and SW for communication with MEg72 indicator Optional N m of four-core cable TBVFS 4 0,22 N pc MEg101.5 power supply in CT IV / 300 V overvoltage category, www.e-mega.cz N pc of secure power supply MEg101.4 CT IV / 300 V, www.e-mega.cz N pc MEg202.3 communication units, www.e-mega.cz N pc Ethernet MEg201.2 communication units, www.e-mega.cz N pc RS485/USB converters Ordering data Number of indicators MEg72 with accessories Number of MEg101.5 power supply in CT IV / 300 V overvoltage category Number of MEg101.4 secure power supply CT IV / 300 V Number of MEg202.3 communication units 17

Měřící Energetické paráty Warranty The MEg72 is covered by a 24-month warranty from the date of purchase, however not longer than 30 months from the date of release from the manufacturer's warehouse. Defects originating during this period as a demonstrable result of defective design, manufacturing or using improper material will be repaired free of charge by the manufacturer or his service organization. The warranty becomes invalid if the user carries out unauthorized modifications or changes on the indicator or on its accessories if he connects the instrument incorrectly or if the indicator or its accessories were operated contrary to technical conditions and user description. The defects on the indicator and its accessories originated during the warranty period shall be claimed by the user to the manufacturer or to the service organization authorized by the manufacturer. The manufacturer bears in any case no responsibility for subsequent damages caused by using the MEg72 indicator and its accessories. The liability of the manufacturer, based on this warranty, does not exceed the price of the indicator. Manufacturer MEg Měřící Energetické paráty, a.s. 664 31 Česká 390, Czech Republic Tel. +420 545 214 988 e-mail: mega@e-mega.cz web: www.e-mega.cz 18

Fuse state indicator MEg72 User manual MEg Měřící Energetické paráty, a.s. 664 31 Česká 390 Czech Republic www.e-mega.cz Edition: 07/2015