RT2DB Excitation and voltage regulation system for synchronous generators

Similar documents
SINAMICS GM150 IGCT version

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Excitation systems for high power synchronous generators with redundant configurations

Unit Protection System for Pumped-Storage Power Stations

825-P Modular Protection System for motors Specification Guide

UNITROL 6800 excitation systems Proven performance solutions

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

Electronic Ballast EVG 2000-T

Power Switching Principles

KD LV Motor Protection Relay

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

TECHNICAL DATA SHEET KVA UPS Systemss

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

SIMOREG DC Master. Application SIMOREG as a field supply unit. 6RA70 Series

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

ELECTRIC MACHINES EUROLAB 0.3 kw

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Motor Starter Reverse MSR22-FBP

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Emotron DCM Control Unit

Dynamic PFC:Thyristor Modules TSM Series

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

Industrial Chargers and

Fuse state indicator MEg72. User manual

Product brochure. Medium voltage AC drive ACS 1000, ACS 1000i 315 kw 5 MW, kv

TECHNICAL SPECIFICATIONS

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

For Operation in the Control Cabinet 3RW Soft Starters

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

TRIPS AND FAULT FINDING

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

POWER SUPPLIES. Control Transformers p8-1 Modular Power Supplies p8-2 Switching Power Supplies p8-3 Automatic Battery Chargers p PAGE

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

POWER kva

INTER PLANT STANDARD - STEEL INDUSTRY THYRISTOR CONVERTORS FOR ARMATURE AND FIELD OF MAIN DRIVE MOTORS. Corresponding IS does not exist

AME. Rectifier - Battery charger. Industrial applications: Key features:

Company profile 2 Profile of ČKD ELEKTROTECHNIKA 2

Technical Data Sheets

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

MX431 Generator Automatic Voltage Regulator Operation Manual

AUTOMATIC STAND-BY AND PEAK-LOAD CONTROL

ELECTRIC MACHINES EUROLAB 0.3 kw

Technical Data Sheets

Power Electronics. Motor brake relay GA 9031 ministop

American Traction Systems. DC Bus Capacitorss. Total. Dual Chopper Module. Dual. Inverter. 750kW. 750kW Generator Module. Module

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

Three Phase UPS Systems Range: 10 to 500kVA

We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

SECTION MOTOR CONTROL

ConceptpowerTM Modular kVA

Uninterruptible Power System

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

Short Term Course On Hydropower Development Engineering (Electrical) for Teachers of Polytechnics in Uttarakhand L33-2

Qingdao Zener Electric Co., Ltd

GENERATION, CONVERSION, OR DISTRIBUTION OF ELECTRIC POWER

CENTROIDTM. AC Brushless Drive. Product Spec Sheet

NUCLEAR OPERATIONS TRAINING ELECTRICAL SCIENCES ES-2 GENERATOR BEHAVIOR AND PROTECTION REVISION 5

Local Control Network - building controls in perfection

PowerPro three phase UPS technical data

DC BRUSHLESS MOTOR CONTROL SYSTEM. Grofu Florin, Assoc. Prof. PhD. Constantin Brâncuși University from Târgu Jiu, ROMANIA

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

Kelly KDC Series/PM Motor Controller User s Manual

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

Comprehensive Technical Training

ADDITIONAL EMERGENCY POWER SUPPLY DEVICES

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

RELIABLE SOLUTIONS in POWER ELECTRONICS. Power Management Instruments RDAT SERIES BATTERY CHARGER / DC RECTIFIER PMI / GESS / KARMET GROUP COMPANIES

Power System Solutions (PSS)

Unit 32 Three-Phase Alternators

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

Exercise 7. Thyristor Three-Phase Rectifier/Inverter EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Thyristor three-phase rectifier/inverter

UPS Wizard User s Manual

GRIDCON ACF ESS GREAT COMBINATION ACTIVE FILTER AND ENERGY STORAGE.

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

ControlReg200/ControlReg200P. Installation and maintenance

UCI224C - Winding 06. Technical Data Sheet APPROVED DOCUMENT

XR500B Universal Voltage Regulator

Temperature Controllers

5220 AUTOMATIC MAINS FAILURE MODULE OPERATING MANUAL

Electronic modules and components. for the control of electromagnetic actuators

DYNACOMP. The top-class reactive power compensator

Operating manual UPS - System

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Temperature Controllers

Products Tde Macno. User s Manual BRAKING UNIT. Cod. MP00401E00 V_1.0

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

Transcription:

s RT2DB Excitation and voltage regulation system for synchronous generators

Fully digital. Parameter settings done by software. Self monitoring routines. Maintenance free. High reliability. Excellent dynamic performance. Strong construction. Several communication protocols available. 1) Introduction The RT2DB excitation system was developed for excitation and voltage regulation of synchronous generators equipped with rotating exciters (brushless or DC exciters). In the case of brushless exciters it will result in a maintenance free power generation system. The system can be used not only in hydro but also in thermal power plants, in new projects or as an excellent alternative for refurbishment of old regulators. The RT2DB excitation system can take the necessary energy either from the terminals of the generator being excited, through a three-phase dry type excitation transformer in this case, or from a permanent magnet exciter (PMG). If a PMG is used to supply the system, its frequency should be at most 100 Hz. The voltage regulation is achieved by actuating on the field winding of the exciter machine. For the field flashing auxiliary energy is taken from the auxiliary power supply (DC or AC). The voltage and current regulation, the setpoint generation, the actual value measuring, the control of the field flashing and shutdown processes, as well as the excitation system monitoring are fully digital. These functions are carried out by a 32 bit processor module, which is plugged in a three-phase fully controlled converter of the series Simoreg DC Master. 2) Power stage The current rectification is carried out by the self cooled Simoreg DC Master unit. The thyristors are protected by monitored ultra-fast fuses. The Simoreg converter is designed taking into account the most severe overload conditions of the generator. In the cases where the excitation system takes its supply voltage from the generator terminals it may be necessary to sustain the excitation current during a short circuit on the generator terminals in order to guarantee the actuation of protection relays or protection selectivity. For that reason the RT2DB excitation system can also include a special circuitry for sustaining the stator current of the generator at a certain level in the case of near short circuit. Fig. 1: The Simoreg DC Master converter unit.

3) Configuration of the electronics The voltage regulation, the control and the monitoring functions of the excitation system are carried out by the processor module T400 plugged in the Simoreg converter. The thyristor gating and monitoring are implemented by the converter itself. The power supply for the electronics is taken in a redundant way from the excitation transformer and from the station battery. Fig. 2: The generator voltage regulation is carried out by the T400 technological board, which is plugged in the Simoreg unit. There are two regulating channels: AUTOMATIC (automatic voltage regulator) and HAND (field current regulation). Both regulating channels (AUTOMATIC and HAND) act on the same power stage. The bumpless channel change-over is carried out by software. 3.1) Automatic channel The automatic channel corresponds to the automatic voltage regulator (AVR), which compares the generator voltage actual value with the reference value (voltage setpoint) adjusted by the power plant operator. The actual values of the active and reactive power are measured directly on the generator terminals through 3 potential transformers with secondary voltages of 110, 115 or 120 V as well as 2 current transformers with secondary current of 1 or 5 A. The generator voltage setpoint is digitally generated and can be adjusted in the range 90% to 110% of the rated generator voltage During the operation of the synchronous generator attention must be paid to its capability diagram. For this reason the following limiters act on the AVR: 3 1. Quick acting limiter (field forcing limiter) 2. Overexcitation limiter 3. Underexcitation limiter 4. Volt/Herz limiter 5. Stator current limiter When a limiter intervenes an indication signal is released. The software routines for the limiters run on the T400 module. The AVR possesses an underordinated regulator. This configuration ensures the system an excellent dynamic behavior and simultaneously allows limiting the excitation current at its maximum values. A power factor (or reactive power) regulator is also included. This additional regulator allows the generator to operate at any desired power factor regarding its capability diagram. The setpoint value is digitally generated by the T400 module.

Fig. 3: By means of the Drive Monitor parametering software it is also possible to record oscillograms of analogical signals. 3.2) Hand channel This control channel corresponds to the regulator. It is extremely useful when performing tests on the generator. In addition the hand channel works as a stand-by regulator allowing continuing of the operation even at failures in the AVR. The setpoint of the ranges from about 10% up to 110% of the rated of the exciter. By taking an independent power supply for the excitation system the setpoint range stretches from zero to 110%. A bumpless channel change-over from AVR to regulator and vice-versa can occur at any time. This is possible thanks to the follow-up routine, which ensures that the selected control channel follows up the settings of the other channel. This way both channels outputs always the same firing angle for the thyristors, what guarantees a bumpless channel change-over at any time. Certain failures involving the AVR cause an automatic changeover to the hand channel. A trip signal is released if failures occur in the hand channel being selected the hand channel. Fig. 4: The regulation and control software is user friendly, what makes the programming and understanding very easy. The excitation cubicle is delivered with provisions both for local control (from the cubicle door) and for remote control (from a central control room). In the standard version of this cubicle the local operation is carried out by means of push buttons on the cubicle door. Alarms and status indications are made by LED signalizations. A man-machine interface (MMI) is optionally available to make the operation of the system easier. This optional device is equipped with keyboard and display (LCD). Through this device commands can be entered and actual system parameters ( and voltage, generator active and reactive power, generator voltage, setpoints etc) can be read out. 3.3) Channel switch over and follow-up control 3.4) Operation 4 Fig. 5: In order to make die operation easier a manmachine interface can be

additionally ordered. The figure shows one of the available models (OP17). There are two standardized types of MMI: a simple one (OP1S) and a more comfortable one, which can display alarm messages of the excitation system in clear text with indication of the time in which the alarm occurred. The RT2DB cubicle can be connected to the superordinated control system by means of normal cabling because all of the input and output signals are available on terminal strips as potential-free contacts. The optional board CBP2 allows the system to be connected to a communication network using the PROFIBUS DP protocol. This communication link can be optionally built using optical fiber. In this case the optional module OLM has to be ordered. Other communication protocols are optionally available. Fig. 6: With the optional module OLM the excitation system can be connected to a PROFIBUS DP communication link using optical fiber. 4) Instrumentation and operation In the standard version of the system the following instruments are installed on the cubicle door: reset push-button, signaling LEDs to indicate operational statuses and grouped alarms and push-buttons to enter commands for the local operation. In the case the optional MMI is ordered neither push-buttons nor signaling LEDs are supplied. 5) De-excitation and overvoltage protection At normal conditions deexcitation is carried out by forcing the thyristor bridge to operate as 5 inverter. The field polarity inversion causes thus a very quick reduction of the towards zero. About 5 s after introducing inverter operation the controller opens the field contactor. Since the at this time will have already reached zero, the main contacts of the field contactor open at no load condition, what increases the lifetime of the device. Additionally the RT2DB excitation cubicle is also equipped with a linear field discharge resistor. It is used to dissipate the stored energy of the exciter field winding in emergency situations, where inverter operation cannot be ensured any more. The RT2DB excitation system has a suppressor device in parallel to its DC output, in order to protect the thyristors and the field winding against induced overvoltages. 6) Mechanical features The excitation cubicle has the following approximate dimensions:

Width: 600 mm Depth: 800 mm Height: 2200 mm The cubicle has only front door. Cables inlet and outlet are made from the bottom. The cubicle is constructed with 1.9 mm dick steel sheets. The supporting frames are made of 2.5 mm dick steel sheets. The cubicle wiring uses self extinguishing copper conductors insulated for 750V. All conductors have identification rings at both ends. Each one of the devices has identification tags with the device symbol according to the electrical diagrams. Each device can be easily accessed. The protection degree is IP41. be installed in a client s existing cubicle saving thus the costs of an additional cubicle. Fig. 7: The Simoreg DC Master converter includes the electronics for controlling and monitoring the fully controlled three-phase rectifier bridge. 8) Optional features The following devices can be additionally ordered: - Man-machine interface; - Rotating diode monitoring (for brushless generators); - Communication board for PROFIBUS DP link; - Communication port for other protocols; - Redundancy in the power stage (in this case two automatic channels are supplied, each one with its own rectifier bridge, i.e. two independent Simoreg DC Master units are supplied); - Compounding circuitry for sustaining the generator current during near short circuit. 7) Optional frame assembly As an economical alternative all the low voltage parts of the RT2DB excitation system can be supplied assembled on a steel sheet (frame) sized 800 x 1200 mm (see Fig. 8). This way the system can 6 Fig. 8: As an economical solution the RT2DB excitation system can also be supplied on a steel sheet to be housed in a client s existing cubicle.

Fig. 9: General diagram of the RT2DB excitation system 7

General technical data of the RT2DB digital excitation system Maximum Up to 20 A DC Maximum ceiling voltage Up to 600 V DC Voltage for control and interfacing From station battery Auxiliary voltage for field flashing Power plant auxiliary power supply (AC or DC); current consumption: 2 A typ. during max 10 s (depends on generator data). Connection to potential transformers 3 x PT s; secondary voltage: 110, 115 or 120 V ( V connection is allowed ); power consumption: 10 VA per phase. Connection to current transformers 2 x CT s; secondary current: 1 or 5 A; power consumption: 10 VA per phase. Regulator Fully digital; double channel configuration: Auto Channel (AVR) and Hand Channel ( regulator). Limiters Quick acting limiter Overexcitation limiter Underexcitation limiter Stator current limiter V/Hz limiter Power supply for the regulator Redundant configuration: from the excitation electronics transformer and from the station battery. Setpoint range Generator voltage: 90%... 110% (typical) Excitation current: 10%... 110% Rectifier Fully controlled thyristor bridge (6 pulses), self cooled, continuous DC output current: 30 A DC. Power requirements from the station Interfacing and control circuits: max. 100 W battery Regulator redundant power supply: max. 250 W Dimensions 600 x 800 x 2200 mm (W x D x H) Approximate weight 300 kg Protection degree of the cubicle IP 41 Finish color Grey Munsell N6.5 or according to customer s specifications. Dimensions of the steel sheet in the 791 x 1200 mm case of frame assembly Standard interfaces Conventional wiring (potential-free contacts) Output signals (4... 20 ma) for remote Excitation current indication Voltage setpoint For more information please contact: Siemens Ltda. Rua Werner Siemens, 111 05069-900 Lapa São Paulo, SP Tel: (11) 3833-4052 / 4106 / 4098 FAX: (11) 3833-4189 Internet: www.siemens.com.br/excitacao E-mails: sebastiao.carpi@siemens.com jorge.humberto@siemens.com Issue: July 2006 8