PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

Similar documents
PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET FEATURES

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

Specifications. 3406C Generator Set Electric Power

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

220 to Volts or 1800 RPM

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

220 to Volts or 1800 RPM

STANDBY 400 ekw 500 kva

Voltage 220 to or 1800 RPM

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

Specifications. C13 Generator Set Electric Power

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

Generator Set Specifications 100 ekw (125 kva)

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

Standby 1500 ekw 1875 kva 60 Hz 1800 rpm 480 Volts

DIESEL FEATURES GENERATOR SET

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

Prime 455 ekw kva 60 Hz 1800 rpm 480 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 350 ekw 438 kva 60 Hz 1800 rpm 480 Volts

Transcription:

DIESEL GENERATOR SET PRIME 508 ekw 635 kva Image shown may not reflect actual package. Caterpillar å is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. FEATURES FULL RANGE OF ATTACHMENTS Ç Wide range of bolt-on system expansion attachments, factory designed and tested ENCLOSURES (optional) Ç Weather protective and sound attenuated SINGLE-SOURCE SUPPLIER Ç Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Ç Worldwide parts availability through the Caterpillar dealer network Ç With over 1844 dealer branch stores operating in 166 countries, you re never far from the Caterpillar part you need Ç 99.7% of parts orders filled within 24 hours. The best product support record in the industry Ç Caterpillar dealer service technicians are trained to service every aspect of your electric power generation system Ç Preventive maintenance agreements Ç The Cat Scheduled Oil Sampling (SÇOÇS SM ) program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT å 3412C TA DIESEL ENGINE Ç Reliable, rugged, durable design Ç Field-proven in thousands of applications worldwide Ç Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight Ç UL 2200 Listed packages are available. Certain restrictions may apply. Consult with you Caterpillar  dealer CAT å SR4B GENERATOR Ç Designed to match performance and output characteristics of Caterpillar diesel engines Ç Optimum winding pitch for minimum total harmonic distortion and maximum efficiency Ç Segregated low voltage, AC/DC accessory box provides single point access to accessory connections Ç UL 1446 Recognized Class H insulation system CAT  CONTROL PANELS Ç Two levels of controls, designed to meet individual customer needs: - EMCP II provides digital monitoring, metering, and protection - EMCP II+ provides EMCP II features along with full-featured power metering and protective relaying WHERE THE WORLD TURNS FOR POWER

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single element canister type air cleaner Service indicator Dual element air cleaner Heavy-duty air cleaner Cooling Radiator with guard and duct flange Coolant drain line with valve Fan and belt guards Caterpillar Extended Life Coolant Low coolant level alarm or shutdown Jacket water heater with shutoff valves Heat exchanger and expansion tank Exhaust Stainless steel exhaust flex and ANSI outlet flange Mufflers (20, 25, or 30 dba) Elbow kit and through-wall installation kit Manifold and turbocharger guards All mufflers have side/end inlet options Fuel Generator Primary and secondary fuel filters Water separator Fuel priming pump Flexible fuel lines Fuel pressure gauge Permanent magnet excited Class H insulation Class F temperature rise (105 C prime/130 C standby) VR6 Voltage Regulator, 3-phase sensing, 2:1 Volts/Hz Reactive droop Extension box Bus bar connection Manual transfer pump Choice of three Automatic Transfer Systems Low fuel level alarm Self excited Digital Voltage Regulator Digital Voltage Regulator with KVAR/PF control Anti-condensation space heater Oversize and premium generators (648 ekw Prime/720 ekw Standby) Circuit breakers, UL Listed, 3-pole with shunt trip Circuit breakers, IEC Compliant, 3-pole or 4-pole with shunt trip Multiple breaker capability Governor PEEC - Cat Electronic Electronic isochronous Electronic load sharing Control Panels EMCP II EMCP II+ Switchgear conversion Customer Communication Module Local alarm and remote annunciator modules Lube Lubricating oil and filter Oil drain line with valves Fumes disposal Manual sump pump Mounting Starting/Charging General Note Formed steel base Linear vibration isolators between base and enginegenerator 45 amp charging alternator Energized to run (ETR) fuel shutoff solenoid 24 volt starting motor Batteries with rack and cables Battery disconnect switch Standard and optional equipment may vary for UL 2200 Listed packages. UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Integral fuel tank base Sub base fuel tank Wide base Skid base Heavy-duty starting system 5 or 10 amp battery charger Oversize batteries Ether starting aid Enclosures - sound attenuated, weather protective Automatic transfer switches (ATS) Floor standing circuit breakers CSA Certification 2

SPECIFICATIONS CAT SR4B GENERATOR Frame Size........................................595 Excitation............................Permanent Magnet Pitch..........................................0.7333 Number of poles.....................................4 Number of bearings.......................single Bearing Insulation.UL 1446 Recognized Class H with tropicalization and antiabrasion IP Rating................................Drip Proof IP22 Alignment...................................Pilot Shaft Overspeed capability - % of rated......................125 Wave form........................less than 5% deviation Paralleling kit/droop transformer.................standard Voltage regulator.....3 Phase sensing with selectible volts/hz Voltage regulation...........less than +/- 1/2% (steady state) Less than +/- 1% (no load to full load) Telephone Influence Factor...................Less than 50 Harmonic distortion.........................less than 5% CAT DIESEL ENGINE 3412C TA V-12, 4-stroke-cycle watercooled diesel Bore - mm......................................137.20 Stroke - mm....................................152.40 Displacement - L..................................27.02 Compression Ratio............................14.5 TO 1 Aspiration.........................................TA Fuel system....................mechanical pump and line Governor type.......................peec - Cat Electronic CAT CONTROL PANELS EMCP II 24 Volt CD Control NEMA 1, IP22 enclosure Electronically dead front Lockable hinged door Generator instruments meet ANSI C-39-1 Generator terminal box mounted Single location customer connection point UL508A Listed Panel illuminating lights Auto start/stop control Voltage adjust potentiometer True RMS AC metering Digital indications for: - rpm - Operating hours - Oil pressure - Coolant Temperature - System DC volts - AC volts, phase amps, Hz Shutdowns with indicating lights for: - Low oil pressure - High coolant temperature - Overspeed - Emergency Stop - Failure to start (overcrank) 3

TECHNICAL DATA Open Generator Set - 1500 rpm/50 Hz/400 Volts PRIME DM0625 Package Performance Power rating @ 0.8 pf 635 kva Power rating 508 ekw Fuel Consumption 100% load with fan 139.8 L/hr 36.9 Gal/hr 75% load with fan 108.1 L/hr 28.6 Gal/hr 50% load with fan 76.4 L/hr 20.2 Gal/hr Cooling System * Ambient air temperature 51 Deg C 124 Deg F Air flow restriction (system).12 kpa 0.48 in. water Air flow (max @ rated speed for radiator 988 m3/min 34,891 cfm arrangement) Engine coolant capacity 59.0 L 15.6 Gal Exhaust System Combustion air inlet flow rate 34.0 m3/min 1,200.7 cfm Exhaust stack gas temperature 605.9 Deg C 1,123 Deg F Exhaust gas flow rate 106.8 m3/min 3,771.6 cfm Exhaust flange size (internal diameter) 203.2 mm 8.0 in Exhaust system backpressure (maximum allowable) 6.7 kpa 26.9 in. water Heat rejection Heat rejection to coolant (total) 319 kw 18,141 Btu/min Heat rejection to exhaust (total) 516 kw 29,345 Btu/min Heat rejection to atmosphere from engine 115 kw 6,540 Btu/min Heat rejection to atmosphere from generator 28.38 kw 1,613.97 Btu/min Alternator ** Motor starting capability @ 30% voltage dip 1247 skva Frame 595 Temperature Rise 105 Deg C Lube System Lube oil refill volume with filter change for 60.0 L 15.9 Gal standard sump * Ambient capability at 200 m (660 ft) above sea level. For ambient capability at other altitudes, consult your Caterpillar dealer. ** UL 2200 Listed packages may have oversized generators with a different temperature rise and motor starting characteristics. Generator temperature rise is based on a 40 degree C ambient per NEMA MG1-32. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: ABGSM TM3, AS1359, AS2789, BS4999, BS5000, BS5514, DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, ISO8528, JEM1359, NEMA MG 1-22, VDE0530, 89/392/EEC, 89/336/EEC Prime - Output available with varying load for an unlimited time. Prime power in accordance with ISO8528. 10% overload power in accordance with ISO3046/1, AS2789, DIN6271, and BS5514 available on request. Prime power ambients shown indicate ambient at 100 percent load which results in a coolant top tank temperature just below the alarm temperature. Ratings are based on SAE J1995 standard conditions. These ratings also apply at ISO3046/1, DIN6271, and BS5514 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º C or 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal). Additional Ratings may be available for specific customer requirements. Consult your Caterpillar representative for details. 5

Package Dimensions Length 4523.9 mm 178.11 in Width 1821.5 mm 71.71 in Height 1960.4 mm 77.18 in Weight 6672 kg 14,709 lb Note: Do not use for installation design. See general dimension drawings for detail (Drawing #1863618). TMI Reference No.: DM0625 PL Reference No.: 412DE0Z U.S. Sourced LEHE2389 26 February 2002 28006 www.cat-electricpower.com 2002 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication.