Directional valves Pneumatically operated, according to standard Brochure
2 Directional valves Pneumatically operated, according to standard 5/2-directional valve, Series CD02-AL Qn = 450 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 3 5/3-directional valve, Series CD02-AL Qn = 250-400 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 5 Single subbase, thread connections on the side standard: ISO 15407-1 Frame size: 18 mm compressed air connection output: G 1/8 standard: ISO 15407-1 Frame size: 18 mm compressed air connection output: G 1/8 Can be assembled into blocks 7 8 End plate left, End plate right standard: ISO 15407-1 Frame size: 18 mm Can be assembled into blocks 9 Supply module standard: ISO 15407-1 Frame size: 18 mm Single base plate principle 10 Transition plate, 26 mm / 18 mm standard: ISO 15407-1 Frame size: 18 mm - ISO 2 Can be assembled into blocks Reversed pressure supply permissible 11 Blanking plate standard: ISO 15407-1 Frame size: 18 mm 12 Sealing kit standard: ISO 15407-1 Frame size: 18 mm 13
Directional valves Pneumatically operated, according to standard 5/2-directional valve, Series CD02-AL Qn = 450 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 3 00108712 Version Spool valve, zero overlap Pilot external Sealing principle Soft sealing Blocking principle principle, multiple See table below temperature min./max. Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Pneumatic ports VDMA 02 base plate Mounting screw M3 Housing Seals Front plate Aluminum, anodized Acrylonitrile Butadiene Rubber; Hydrogenated nitrile butadiene rubber Polyamide Qn Working pressure min./max. Control pressure min./max. Weight Note Part No. [l/min] [bar] [bar] [kg] 450 2 / 10 -- / 10 0.08 1) 0820238103 450-0.9 / 10 1.5 / 10 0.08-0820238104 1) See diagram Control pressure for spring/air spring return valves Pe = external control pressure, min. P B = Working pressure 00108710_a
4 Directional valves Pneumatically operated, according to standard 5/2-directional valve, Series CD02-AL Qn = 450 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 00108713
Directional valves Pneumatically operated, according to standard 5/3-directional valve, Series CD02-AL Qn = 250-400 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 5 00108716 Version Spool valve, zero overlap Pilot external Sealing principle Soft sealing Blocking principle principle, multiple -0.9 bar / 10 bar temperature min./max. Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ Pneumatic ports VDMA 02 base plate Mounting screw M3 Housing Seals Front plate Aluminum, anodized Acrylonitrile Butadiene Rubber; Hydrogenated nitrile butadiene rubber Polyamide Qn Control pressure min./max. Weight Part No. [l/min] [bar] [kg] 400 2.2 / 10 0.11 0820239104 250 2.2 / 10 0.11 0820239105 250 2.2 / 10 0.11 0820239106
6 Directional valves Pneumatically operated, according to standard 5/3-directional valve, Series CD02-AL Qn = 250-400 l/min plate connection compressed air connection output: VDMA 02 base plate Can be assembled into blocks 00108717
Directional valves Pneumatically operated, according to standard 7 Single subbase, thread connections on the side standard: ISO 15407-1 Frame size: 18 mm compressed air connection output: G 1/8 00108719-15 C / +70 C temperature min./max. -15 C / +70 C 0 bar / 16 bar Direction of pneumatic port (1) Direction of pneumatic port (3,5) Direction of pneumatic port (2,4) Direction of pneumatic port (12) Direction of pneumatic port (14) Exhaust (3,5) With directional exhaust (3/5) Die cast zinc Frame size connection Weight Part No. Input Output Exhaust Pilot control exhaust Pilot connection [1] [2 / 4] [3 / 5] [12] [14] [kg] 18 mm G 1/8 G 1/8 G 1/8 M5 M5 0.135 1825503890 Ports 82 and 84: pilot exhaust air Connection 12 and 14: external pilot 00108732
8 Directional valves Pneumatically operated, according to standard standard: ISO 15407-1 Frame size: 18 mm compressed air connection output: G 1/8 Can be assembled into blocks temperature min./max. Direction of pneumatic port (2,4) -15 C / +70 C -15 C / +80 C 0 bar / 16 bar 00112338_b Seals Die cast zinc Acrylonitrile Butadiene Rubber Intermediate plate with gasket Frame size connection Weight Part No. Output [2 / 4] [kg] 18 mm G 1/8 0.15 1825503891 00108723_a
Directional valves Pneumatically operated, according to standard 9 End plate left, End plate right standard: ISO 15407-1 Frame size: 18 mm Can be assembled into blocks 00112338_a -15 C / +70 C temperature min./max. -15 C / +70 C 0 bar / 16 bar Mounting screw with hexagon socket Direction of pneumatic port (1) Direction of pneumatic port (3,5) Direction of pneumatic port (2,4) Direction of pneumatic port (12) Direction of pneumatic port (14) Exhaust (3,5) With directional exhaust (3/5) Ports separated Seals Screws Die cast zinc Acrylonitrile Butadiene Rubber Steel, galvanized Frame size connection Weight Part No. Input Exhaust Pilot control Pilot connection exhaust [1] [3 / 5] [12] [14] [kg] 18 mm G 1/4 G 1/4 G 1/8 M5 0.335 1825503892 Scope of delivery incl. seal and mounting screws
10 Directional valves Pneumatically operated, according to standard 00108723_b Supply module standard: ISO 15407-1 Frame size: 18 mm Single base plate principle 00108751 temperature min./max. Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ -0.9 bar / 10 bar Number of valve positions 1 Grid dimension 19 mm Mounting screw with hexagon socket Direction of pneumatic port (1) Exhaust (3,5) With directional exhaust (3/5) Ports separated Aluminum
Directional valves Pneumatically operated, according to standard 11 Scope of delivery incl. seal and mounting screws Frame size connection Weight Part No. Input [1] [kg] 18 mm G 1/8 0.0195 1827009938 00108726 Transition plate, 26 mm / 18 mm standard: ISO 15407-1 Frame size: 18 mm - ISO 2 Can be assembled into blocks Reversed pressure supply permissible 00106829 ISO 15407-1 -15 C / +70 C temperature min./max. -15 C / +80 C -0.95 bar / 16 bar Mounting screw with hexagon socket Exhaust (3,5) uncollected exhaust Ports separated Seals Aluminum Acrylonitrile Butadiene Rubber
12 Directional valves Pneumatically operated, according to standard Scope of delivery incl. seal and mounting screws Frame size Weight Part No. [kg] 18 mm, 26 mm 0.311 1825504036 ISO 2, 26 mm 0.389 1825504037 00106798 Blanking plate standard: ISO 15407-1 Frame size: 18 mm 00108748 temperature min./max. Max. particle size 5 µm Oil content of compressed air 0 mg/m³ - 5 mg/m³ -0.9 bar / 10 bar Mounting screw with hexagon socket Seals Aluminum Acrylonitrile Butadiene Rubber
Directional valves Pneumatically operated, according to standard 13 Scope of delivery incl. seal and mounting screws Frame size Weight Part No. [kg] 18 mm 0.019 1825503933 00108724 Sealing kit standard: ISO 15407-1 Frame size: 18 mm -15 C / +70 C 00128803
14 Directional valves Pneumatically operated, according to standard Part No. Type Weight [kg] 1823051991 Threaded rods for the assembly of 2 intermediate plates 1823051992 Threaded rods for the assembly of 3 intermediate plates 1823051993 Threaded rods for the assembly of 5 intermediate plates 1821015812 Intermediate plate valve molded seal 1821015815 Gasket for intermediate plates, 1 closed, 3 and 5 open 1821015817 Gasket for intermediate plates, 1, 3, and 5 open 1827003825 Separator for channel 3 + 5 1) 2 intermediate plates 2) 3 intermediate plates 3) 5 intermediate plates Delivery quantity [Piece] Fig. Note 0.014 5-1) 0.022 5-2) 0.038 5-3) 0.005 10 - - 0.001 5 Fig. 2-0.001 10 - - 0.06 2 Fig. 1 - Fig. 1 Separator for channel 3 + 5 Fig. 2 Separating seal for channel 1 00131763
AVENTICS GmbH Ulmer Straße 4 30880 Laatzen, GERMANY Phone +49 511 2136-0 Fax +49 511 2136-269 www.aventics.com info@aventics.com Find more contact information at www.aventics.com/contact Only use the AVENTICS products shown in industrial applications. Read the product documentation completely and carefully before using the product. Observe the applicable regulations and laws of the respective country. When integrating the product into applications, note the system manufacturer s specifications for safe use of the product. The data specified only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that the products are subject to a natural process of wear and aging. 26-07-2016 An example configuration is depicted on the title page. The delivered product may thus vary from that in the illustration. Subject to change. AVENTICS S.à r.l. This document, as well as the data, specifications and other information set forth in it, are the exclusive property of AVENTICS S.à r.l.. It may not be reproduced or given to third parties without its consent. PDF online