updated 09/2010 Series 100 Valves

Similar documents
Series 500 Valves. Product Catalogue. Series 500 Valves. Series 500 Valves. Catalogue. Edition 10/2012

DOROT CONTROL VALVES CATALOGUE

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

SMART SOLUTIONS FOR WATER 600 Series Hydraulic Control Valves Waterworks Irrigation

CATALOGUE AUTOMATIC CONTROL VALVES

Super Gal. Super Gal. Model 75 - High Capacity Plastic Control Valve. Product Catalogue. Super Gal Catalogue. Model 75.

updated 08/2010 SOLENOID VALVES

Pilot Valves Catalogue

Pneumatics, Automation & Control Solutions

Series 95/96 upvc Valves

CAST IRON VALVES PRESSURE REDUCING VALVES SERIES

Product Catalogue. Series 75 Valves. Valves. Catalogue. Series 75. Edition 09/2017

ELECTRIC & HYDRAULIC VALVES

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

BERMAD Waterworks. Booster Pump Control Valve Active Check Valve. 700 Series. Model 740. Features and Benefits. Major Additional Features

Structural Simplicity and Superior Hydraulic Performance. Valve Operation Guide

Valve Operation Guide

Dorot Fire Protection Control Valves

BERMAD BERMAD BERMAD WW M

WATERWORKS. Reach Optimum Efficiency with OCV Control Valves.

Deluge Pressure Reducing Valves. Model 68 DE\ EL\ PORV\ PR. Electrically and Pneumatically Actuated, Pressure Reducing, Remote-Reset, Deluge Valve

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

BERMAD. Hydraulic Control Valves. 700 Series

Piston Actuated Valve Type G

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

Deluge Pressure Reducing Valves. Model 68 DE\ RCL\ PR. Electrically Actuated, Manual-Reset, Pressure Reducing, Deluge Valve

DSF Series Irrigation Valves from IrriRich

Deep Well Pump Control Valve

PRESSURE REDUCING CONTROL VALVE

PRESSURE REDUCING VALVE

HYDRAULIC CONTROL VALVES

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

HYDRAULIC CONTROL VALVES

PRESSURE REDUCING VALVE

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

PRESSURE REDUCING VALVE

700 LARGE SIZE SERIES

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Automatic Control Valves

SMART SOLUTIONS FOR WATER Product Brochure Waterworks Fire Protection Irrigation Filtration

Deluge Valves. Model 68 DE\ HM-MR. Hydraulically Actuated Manual-Reset Deluge Valve. Dorot Fire Protection Division

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Electronic Control Valves

BERMAD Waterworks. BERMAD 700 Large Size Series. 700 Series. Features and Options. Model: 700-M5, 700-M6, 700-M5L

PRESSURE RELIEF VALVE CONTROL VALVE

INTERNATIONAL REPORT...24

Deluge Valves. Model 68 DE\ HRV-MR. Hydraulically Actuated, Anti-Columning, Manual-Reset Deluge Valve. Dorot Fire Protection Division

T he -A900 series of automatic control

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

Automatic control valves XLC 300 and 400 series

Solenoid Valves. Product Catalogue. Solenoid Valves. (Product Catalogue) Solenoid Valves

Check Valve MODEL. Schematic Diagram. Product Dimensions Data:

800 Series Control Valves

Series 758 FireLock Actuated System Valve

Differential Piston Control Valves Pressure, Level and Flow Control

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

BERMAD Irrigation. IR-300 Basic Valve. 300 Series. ??????? Basic Valve

Series 800 AWWA Butterfly Valves

AUTOMATIC CONTROL VALVES

AUTOMATIC CONTROL VALVES. TIS asia

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

SECTION MISCELLANEOUS VALVES

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

SINGER VALVE CONDENSED PRODUCT CATALOGUE INDUSTRIAL

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

AVIATION FUELING CONTROL VALVES

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

AUTOMATIC CONTROL VALVES BY RAPHAEL

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Valve Selection. 1. Function and service considerations

Instructions for Installation, Operation, Care and Maintenance

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions

Automatic control valves XLC 400 series

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

30.85 FireLock NXT Actuated Valve with LPCB Approved Preaction Trim

Bermad with Flow Control 100 Series. Code Dimensions Coil Type Z7721B 2 24VAC S390 Z7721C 3 24VAC S390. Pressure Reducing ( bz) 100 Series

Titan Check Valves. Call. Fax. . Visit. Titan Flow Control. Your Pipeline to the Future

FireLock NXT Deluge Valve. With Deluge Trim Grooved x Grooved. System No. Submitted By Spec Sect Para Location Date Approved Date

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

Ordering Guide. Ordering Guide. May Water Control Solutions

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

BERMAD Irrigation. 300 Series. Basic Valve. ??????? IR-300 Basic Valve.

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

Automatic control valves XLC 400 series

BERMAD Fire Protection

Booster Pump Control Valve

Automatic Control Valves. Providing quality, performance, dependability, and value for water control applications

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

Series 769 FireLock NXT Deluge Valve

Backflow Preventers & Accessories

T e n c a n Backflo w Specialties

Transcription:

updated 09/00 Series 00 Valves

Contents Dorot Series 00 General Technical Data Available Models 6 Design Specifications 6 Diaphragm Selection Table 7 Dimensions and Weights 8 Main Components 0 M Manually Controlled Valve EL Solenoid Controlled Valve RC Hydraulic Remote Controlled Valve PR Pressure Reducing Valve PS Pressure Sustaining & Relief Valve 6 DI Pressure Differential Sustaining Valve 7 FR Flow Control Valve 8 FE Excessive Flow Shut-off Valve 9

Contents FL Modulating Float Controlled Valve 0 FLEL Electric Float Controlled Valve FLDI Differential Float Controlled Valve AL Altitude Pilot Controlled Valve BC Booster Pump Control Valve DW Deep Well (Borehole) Pump Control Valve RE Surge Anticipating Valve 6 QR Quick Pressure-relief Valve 7 TO Two Stage Opening Addition 8 SP Surge Preventing Stepped-Closure Addition 9 EC PLC Controlled Valve 0 DE Deluge Dry-pipe and Pre-action Valves Pilots and Accessories Other Dorot Products s

General Dorot Series 00 The direct sealing diaphragm valves were introduced to the world market for the first time by DOROT CONTROL VALVES at 98. This valve is operated by the pressure of the pipeline and is used for various control applications in water supply, fire fighting, industrial, sewage and irrigation systems. The only moving component is a reinforced diaphragm, which: a. Drip tight seals the liquid passage in the closed valve b. Allows free passage in the fully open valve with minimal obstruction to the flow line c. Throttles the flow passage in the modulating valve, as dictated by the pressure in the control chamber The valve can be closed or modulated using the line pressure or an external separate pressure source that is equal or higher than the line pressure. Dorot S-00 valves are made for easy, inline maintenance, executed also by unskilled personal using basic tools. There are no shafts, bearings or seals that may corrode and there is no wear and tear by dirty abrasive water or chemicals. and benefits Structural simplicity Superb design featuring exceptionally low pressure losses at high flow rates Can be used for regulating from no-flow to maximal flow with no need for additional throttling devices or by-pass valves For natural liquids, sea water and industrial effluents A wide selection of materials, coating and diaphragm types All valve models fit a wide variety of control applications using Dorot pilot valves

General Principle of operation -way control system The main valve is controlled by a manually, electrically or pressure actuated selector that: Introduces the upstream pressure or an external pressure source to the valve s control chamber, thus pressing the valve diaphragm from top to a closed position. Openes the valve by relieving the pressure from the control chamber and enabling the internal pressure in the line to push the valve diaphragm up and creating an unrestricted, full flow passage. Shutes all passages to and from the control chamber, thus keeping the main valve in a fixed position. This position does not exist in devices used for ON/OFF control applications but is necessary in modulating valves. -way control system A control system that consist of two restrictions: a. A fixed restriction at the upstream side of the control system (nozzle or needle valve) b. ON/OFF device (valve, relay or solenoid) or a modulating pilot valve with a larger passage than restriction a that is installed at the downstream side of the control system. The main valve position is affected by the downstream pilot valve b in the following ways: When the pilot valve is closed, no water can be vented to the downstream and the main valve is closed by the upstream pressure, introduced into the valve control chamber through the restriction a. Opening the valve is enabled when the pilot b is fully open and allows the drainage of pressure in the control chamber to the down stream. At this position the pressure in the control chamber nearly equals that of the downstream. Throttling pilot valve b so the flow running through it equals the flow entering through the restriction a, keeps a fixed volume of water in the control chamber and the main valve in a fixed position. Needle valve a b Pilot valve Needle valve a b Pilot valve Needle valve a b Pilot valve

Technical Data Available Models Pattern Type 7 87 77 8 8 A 9 67 9 Connection Threaded Threaded Victaulic Flanged Flanged Flanged Flanged Threaded Victaulic Threaded Flanged Threaded Material Cast Iron Bronze Cast Iron Cast Iron Bronze Ductile Iron Cast Iron Cast Iron Cast Iron Bronze Ductile Iron Ductile Iron Max. Pressure 6bar / 0psi bar / 60psi mm inch 0 / 0 / 0 6 / 80 80 00 0 6 00 868 00 8 0 0 00 0 00 6 0 8 00 0 600 Available Sizes Design Specifications Materials Standard Optional * Body and Bonnet Cast Iron, Ductile Iron, Bronze Cast Steel, Stainless Steel Diaphragm Natural Rubber NBR,EPDM,Neoprene Connections Standard Optional * Flanges ISO 08,, 7 ANSI B6 JIS B AS 0 Spring SST 0 SST 6 Nuts And Bolts Coated Steel SST Threads F-BSP F-NPT Coating Polyester Epoxy, Nylon, Rubber * Others Upon Request Non Standard Bonnets Control Bores /8,/,/ NPT Throttling Bonnet Position Indicating Bonnet 6

Technical Data Diaphragm Selection Table* Diameter Type No. Pressure Range mm inch mwc psi 0, /, Standard 8-60 7-0 Low Pressure 8-00 7-0 0 / Standard -60 7-0 S. Low Pressure 8-0 7-70 Standard 0-60 -0 0, 6, /, Low Pressure 0 7-00 0-0 S. Low Pressure -0 6-70 Extreme 60 0-60 8-0 0HP HP High Pressure 69 0-0 -60 Standard -60 7-0 80, 00, Low Pressure 0-00 6-0 Extreme 6 0-60 8-0 80HP HP High Pressure 70 0-0 -60 00HP HP High Pressure 7 0-0 -60 Standard 6 0-60 8-0 0 6, 868 Low Pressure 09-00 7-0 S. Low Pressure 9-60 -8 0HP 6 HP High Pressure 7 0-0 -60 Standard 6 7-60 0-0 00, 00, 0 8,, Low Pressure 7-00 -0 Extreme 6 0-60 8-0 00HP 8 HP High Pressure 7 0-0 -60 0 0 Standard 0 7-60 0-0 Low Pressure 0-00 -0 0HP, 00HP, 0 HP, 6 HP, High Pressure 78 0-0 -60 00HP, 600HP 0 HP, HP Low Pressure 9-00 -0 * Standard Diaphragm: Nylon Reinforced Natural Rubber. Optional Materials: Nitrile, EPDM, Neoprene Available Upon Request. ** HP = High Pressure Pressure Rating Pressure rating of series 00 valves is body strength, connection standard and diaphragm type. Pressure rating of valve body of standard models: 6 Bar / 0 psi. Pressure rating of valve body of high pressure models: Bar / 60 psi. Connection standard is marked on the identification plate, assembled on the valve body. Diaphragms operation pressure range is presented at the above table. 7

Technical Data Dimensions and Weights Straight Flow, Threaded Connection Valve Size L H Weight D W Cast Iron Bronze Cast Iron Bronze Cast Iron Bronze mm inch mm inch mm inch mm inch mm inch mm inch mm inch kg lbs kg lbs 0 / 7 / / / 6 / 6 0 / 68 / 6.. 0 / 9 / 6 / 6 / 6 / 6 68 / 6.. 0 / 70 6 / 6 9 / 6 9 / 86 / 8 9 / 6 9 /..9.8 0 88 7 / 8 7 / 6 7 / 0 / / 6 /. 7.6.7 6 / 9 8 / 8 8 / 8 / 6 09 9 / 6 / 6 /.6 7.9. 7. 80LF * 8 / 6 8 / 6 6 / 6 6 9 / 6 / 8 /. 9.9.9 8. 80 6 / 6 6 / 6 / 6 / 6 / 6 00 7 7 / 8 L L D D H H w * LF = Low Flow L w D H Straight Flow, Grooved Connection (Vic.) Valve Size L H D W Weight mm inch mm inch mm inch mm inch mm inch kg lbs 0 / 77 6 / 8 / 6 6 / 6 9 /.8 0 90 7 / 6 00 / 6 9 / 6 /.6.7 80 0 7 9 / 0 / 7 7 / 6 / 6.6 80LF 86 / 7 / 8 7 7 / 6 00 7 7 / 8. 00 7 / / 6 60 / 6 9 7 / 6 6. 0 6 9 7 / 6 0 9 7 / 8 7 / 00 / 6 68. L D H w Angle Flow, Grooved Connection (Vic.) Valve Size H D W Weight mm inch mm inch mm inch mm inch kg lbs 80 0 9 7 / 6 70 6 / 6 00 7 7 / 8 0.. 00 0 9 7 / 8 7 9 / 00 7 7 / 8.. Angle Flow, Threaded Connection Valve Size H D W Weight mm inch mm inch mm inch mm inch kg lbs 0 / 0 / 6 7 6 / 6 9 /.7.7 0 6 / 90 / 6 /.. 80LF 6 6 / / 6 /.6 7.9 80 9 9 / / 6 00 7 7 / 8 0.8.8 D H w Angle Flow, Flanged Connection Valve Size H D W Weight mm inch mm inch mm inch mm inch kg lbs 80 78 9 / 6 7 8 7 / 00 7 7 / 8 8 9.7 00 00 / 6 8 7 9 / 0 9 / 6 6. 0 6 80 6 / 6 0 9 / 6 00 / 6 99. H w D w L L D D H H w w D H H D w w D H H D w w 8

Technical Data Dimensions and Weights Straight Flow, Flanged Connection - Standard Models 6 Bar / 0 psi Valve Size L H D W Weight Cast Iron Duct. Iron Bronze mm inch mm inch mm inch mm inch mm inch kg lbs kg lbs kg lbs 0 00 7 7 / 8 66 6 7 / 8 / 66 6 7 / 7..8 7.7 7 8 7.6 80LF 00 7 7 / 8 0 7 6 / 6 0 / 8 00 7 7 / 8..8 6 80 8 7 / 00 7 7 / 8 0 / 8 00 7 7 / 8 7 7. 8. 0. 9 00 0 0 9 / 6 0 / 6 0 9 / 6 8. 0 6 90 / / 6 / 6 00 / 6 6 0 9 08 00LF 868 8 / 0 / 70 6 / 6 6 / 8 0 0 9 00 8 60 8 7 / 6 00 / 70 6 / 6 6 / 8 80 76 86 90 89 96 0 0 / 6 7 / 6 0 8 / 6 0 7 / 6 7 8 76 89 00 80 / 6 9 9 7 / 6 0 9 7 / 6 90 9 9 / 6 67 68 7 0 80 / 6 9 9 7 / 6 70 0 / 8 0 / 8 0 7 79 80 97 L w L w D D H H Straight Flow, Flanged Connection - High Pressure Models Bar / 60 psi Valve Size L H D W Weight mm inch mm inch mm inch mm inch mm inch kg lbs 0 8 8 / 69 6 / 8 / 7 6 7 / 6 0 0TH TH 0 9 7 / 0 / / 7 6 7 / 6 6 80 0 / 6 7 9 / 6 0 / 8 00 7 7 / 8 0 66. 00 6 / 6 6 0 / 0 / 60 0 / 6 8 8.8 0 6 6 7 / 78 7 / 8 0 7 / 6 0 9 / 7 6. 00 8 0 0 / 6 8 8 / 6 80 7 / 00 / 7 0 0 66 / 6 / 8 / 9 9 7 / 6 90 9 00 6 709 7 9 / 80 / 6 0 / 6 80 / 6 9 0 8 7 8 / 80 / 6 0 / 6 80 / 6 60 0 00 0 900 7 / 6 970 8 / 6 90 9 9 / 980 8 7 / 6 67 86 600 900 7 / 6 970 8 / 6 90 9 9 / 980 8 7 / 6 696 * TH = Threaded L w L w D D H H 9

Technical Data Hydraulic Performance Valve Size Max. Flow Continuance Max. Flow Intermittent mm 0 0 0 6 80 80LF 00 0 00LF 00 0 00 0 00 0 00 600 inch / / / 6 868 8 0 6 8 0 m /hr 6 0 0 0 0 00 60 0 0 60 970 00 00 00 00 890 00 gpm 6. 0 76 76 76 0 700 0 0 70 68 660 660 000 000 76 00 m /hr 6 7 68 09 09 09 7 9 9 09 6 88 88 688 688 0609 0609 gpm 7 0 00 80 80 80 080 00 00 00 760 60 6800 6800 0000 0000 6680 6680 Minimal Flow m /hr < gpm < Kv m /hr @ bar 7 7 6 9 9 9 70 0 600 670 800 0 900 900 600 600 600 600 Cv gpm @ psi 0 0 7 0 0 0 00 60 700 780 90 60 0 0 00 00 70 70 Kv* m /hr @ bar - - - 78 - - 0 00 0-800 00 - - 600 600 600 600 Cv* gpm @ psi - - - 9 - - 0 0 60-90 0 - - 00 00 70 70 * High pressure models m Q[ ] P (Bar)= ( hr Kv ) P (Psi)= ( Q[gpm] Cv ) Headloss Chart 0 9 8 7 6 psi mwc 0 9 8 7 6 0 9 8 7 6 0 9 8 7 6 / / 0 00 000 000 psi mwc 0 00 / /, /,, /, 000 6, 868 8 6, 868 0 8, 0 0000 6, 8, 0, 6, 8 m /hr 0, gpm m Q[ ] P (Bar)= ( hr Kv ) P (Psi)= ( Q[gpm] Cv ) 0 00 000 000 0 00 000 0000 m /hr gpm Cavitation Data Upstream Pressure psi bar 0 00 0 0 00 0 0 00 0 Cavitation zone Safe zone for Bronze valves Safe operation zone 0 0 6 7 8 0 0 0 0 0 60 70 80 90 00 0 Downstream Pressure bar psi 0

Technical Data Main Components Pilot valves for superb regulation at high reliability Unique Design Creating low losses at high flow rates Internal SST spring: allows the use of wide range of diaphragm rubber types Flexible reinforoed diaphragm-no bearing, guides or internal seals used Polymeric coating, UV and corrosion resistant Wide materials variety Components 0 8 7 9 6 Component No. Body Bonnet Diaphragm Spring Spring Disc 6 Bolt 7 Short Bolt 8 Washer 9 Nut 0 Suspension Ring (Hook) 9 8 6 9 8 6

M Manually Controlled Valve The valve is controlled manually by a three port selector that allows the user to select the closed, opened or remotecontrolled position of the valve. The control is effected effortlessly and quickly, even under high pressure conditions Effortless open/close activation Fast response Clog-free operation Can be added as manual over-ride to any other control function Main Valve Self-flushing filter Cock valve* -way selector valve Accelerator relay (optional for valves larger than 0mm/6 ) The valve will be a direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by a hand operated selector valve. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Preferred selection of low pressure diaphragms when the valve is expected to stay in open position for long periods Dorot Manually controlled valve installed in an underground, flooded pit. Manual activation is enabled from top by the selector valve.

EL Solenoid Controlled Valve A -way solenoid valve, activated by an electric current or an electric pulse, opens or closes the main valve. The standard valve is supplied in the normally closed position. The normally open position is optional. Electric activation can be added to other control applications on request. Low power electric activation Fast response Can be added as electric over-ride to any other control function Main Valve Self-flushing filter Cock valve* / Solenoid valve Accelerator relay (optional for valves larger than 0mm/6 ) The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by an electric solenoid valve. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Prefer selection low pressure diaphragms when the valve is expected to stay in open position for long periods The valve can be opened by the electric command (NC) or closed by it (NO). The definition refers to the main valve operation and not the solenoid s characteristics Dorot Solenoid Controlled valve, controlled by a local controller.

RC Hydraulic Remote Controlled Valve Remote pressure command A -way relay valve, activated by hydraulic or pneumatic pressure command, opens or closes the main valve. The standard valve is supplied in the normally closed position. The normally open position is optional. Hydraulic activation can be added to other control applications on request. Fast response even for long control lines Can be added as pressure command over-ride to any other control function Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* Accelerator relay (other types are optional) The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by a hydraulic relay. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Prefer selection low pressure diaphragms when the valve is expected to stay in open position for long periods The valve can be opened by the pressure command (NC) or closed by it (NO). The definition refers to the main valve operation and not the relay s characteristics Dorot Hydraulic Remote Controlled Valve, activated by a remote pressure command.

PR Pressure Reducing Valve The valve maintains a preset downstream pressure, regardless of upstream pressure or flow rate fluctuation. The main valve is controlled by either a -way pilot valve (allowing full opening when upstream pressure drops below the pressure set-point), or by a -way pilot valve (creating a minimal differential in open position). Accurate, stable control from no-flow to full flow Exceptionally low losses at high flow WRAS Approval no. 0 Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* -way pilot valve (other types are optional) The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure reducing pilot valve to achieve constant outlet pressure, regardless of upstream pressure or flow variations. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and In case upstream pressure may drop to the required set pressure, select -way control pilot Large pressure differentials may cause cavitation damage. Consult Dorot for solutions if such conditions are expected Dorot Pressure Reducing Valve reduces varying supply pressure to a stabilized downstream pressure.

PS Pressure Sustaining & Relief Valve The valve maintains upstream pressure, regardless of flow rate variations. The valve will be in the closed position if the upstream pressure drops below the set-point and will fully open when the upstream pressure exceeds the set-point. Accurate, stable control from no-flow to full flow Exceptionally low losses at high flow Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* -way pilot valve (other types are optional) The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure sustaining pilot valve to maintain constant inlet pressure, regardless of flow variations. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) The valve should be suited for the maximal flow and allowed headloss Check for possible cavitation conditions and consult Dorot in case such conditions are expected Dorot Pressure Relief Valve relieving pump surplus flow from the system, thus preventing high pressure at low demand conditions. 6

DI Pressure Differential Sustaining Valve The valve maintains a preset pressure differential between its upstream and downstream sides. The valve can control booster pump discharge, heating and cooling systems, bypass configurations, filters and other similar systems. Accurate, stable control from no-flow to full flow Exceptionally low losses at high flow The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure sustaining differential pilot valve so to maintain a minimal pressure differential, regardless of flow variations. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* -way pilot valve (other types are optional) Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Check for possible cavitation conditions and consult Dorot in case such conditions are expected The connection points of the sensing tubes must be selected in locations free of turbulence and local interferences Dorot Pressure Differential Sustaining Valve controls the flow at the discharge of a booster pump whose suction pressure varies. 7

FR Flow Control Valve 6 The valve limits the flow rate in the network to a preset, value regardless of upstream pressure variations. The valve fully opens when the flow rate drops below the set point. Accurate, stable control Low losses when the demand is lower than the set flow Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* -way differential pilot valve (other types are optional) 6 Orifice plate The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure reducing differential pilot valve for controlling the flow through the main valve, regardless of pressure variations. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) of the valve A / pressure sensing port should be provided, upstream Check for possible cavitation conditions and consult Dorot in case such conditions are expected An additional pressure loss of about. mwc is created by the orifice plate (at the set flow) Dorot Flow Control Valve limits the flow to a specific customer. 8

FE Excessive Flow Shut-off Valve 6 The valve closes drip tight when the flow rate exceeds the normal value (due to pipe rupture). The valve will manually re-set open after fixing the break. used Hydraulic burst protection.no electronic controllers are Low losses The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure reducing differential pilot valve for closing when the flow through the main valve exceeds the safe level, regardless of pressure variations. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* -way differential pilot valve (other types are optional) 6 Orifice plate Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) of the valve A / pressure sensing port should be provided, upstream The valve is adjusted to close when the flow rate exceeds the maximal design flow by 0%-0% An additional pressure loss of about mwc is created by the orifice plate (at the normal flow) Dorot excessive flow shutoff valve installed to prevent flood damages caused by pipe rupture. 9

FL Modulating Float Controlled Valve The main valve is controlled by a float valve, located in the tank or reservoir and set at the required maximum water level. The valve maintains the maximum level continuously. Accurate and repeatable level control Easy installation and maintenance Adjusts the inlet flow to the reservoir s outlet flow WRAS Approval no. 000909 Main Valve Self-flushing filter Cock valve* Needle valve Modulating float pilot valve The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure and be operated by a modulating, -way float activated pilot valve. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as the fill line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) The valve should be suited for the maximal flow Upstream pressure at closed position should be at least 0m (psi) higher than the hydrostatic water pressure at the downstream Large pressure differentials may cause cavitation damage. Consult Dorot for solutions if such cases are expected Prefer use of differential level control in case excessive noise should be avoided (residential areas) Dorot Modulating Float Controlled valve prevents tank overflow. 0

FLEL Electric Float Controlled Valve An electric sensor float, located in the tank/reservoir, sends a command to a solenoid controlled valve. The main valve will fully open when the solenoid activated and will close drip tight when the solenoid de-energized, thus enabling accurate and reliable differential level control. Optional Addition: Stepped Surge-Preventing Closure. Accurate and repeatable differential level control Low power electric activation Fast response Easy installation and maintenance Main Valve Self-flushing filter Cock valve* / Solenoid valve Accelerator relay (optional for valves larger than 0mm/6 ) 6 Electric float switch The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by an electric solenoid valve activated from a float in the tank/reservoir. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and The valve can be opened by the electric command (NC) or closed by it (NO). The definition refers to the main valve operation and not to the solenoid s characteristics Dorot Electric Float Controlled Valve controlling the water volume in a tank.

FLDI Differential Float Controlled Valve 6 A float valve controls the main valve, closing it when the water reaches maximum level, and opening it when the water drops to its preset minimum level. The differential between the maximum and the minimum levels is adjustable. Optional Addition: Stepped Surge-Preventing Closure. Accurate and repeatable differential level control Adjustable differential Fast response Easy installation and maintenance Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* Accelerator relay (optional for valves larger than 0mm/6 ) 6 -way differential pilot valve (other types are optional) The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic pressure. The valve position will be controlled by a -way float pilot located at the top of the tank/ reservoir. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) The valve should be suited for the maximal flow Upstream pressure at closed position should be at least 0m (psi) higher than the static water pressure at the downstream Fast stream and waves may cause mechanical damage to the float levers. It is advisable to install the pilot in a still part of the reservoir Dorot Differential Float Pilot Controlled Valve controlling the water volume in a filling or emptying tank.

AL Altitude Pilot Controlled Valve Tank/Reservior connection The main valve is controlled by a highly sensitive pilot, located outside the tank. The pilot opens or closes the valve in response to the static pressure of the water. The pilot allows for differential adjustments between the maximum and minimum level. Optional Addition: Stepped Surge-Preventing Closure. Accurate and repeatable differential level control Fast response Easy access - no float is located in the tank/reservoir Easy installation and maintenance Main Valve Self-flushing filter Cock valve* Manual over-ride selector valve* High sensitivity altitude control pilot valve The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by a hydrostatic pressure sensing pilot valve. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) the closing level in the tank The valve should be suited for the maximal flow The pilot valve must be located at least meters below When water-hammer/surge expected during closure - add stepped surge preventing closure function to the altitude control pilot Dorot Altitude Pilot Controlled Valve controlling the water volume in an elevated tank.

BC Booster Pump Control Valve 6 7 6 8 7 The valve eliminates damaging surges caused by pump start-up and shut-off. The electrically activated valve gradually opens on pump start up, and slowly closes before the pump is switched off. The valve will automatically close drip tight in case of power failure. Optional Additions: Flow Rate Limitation, Extended Closure, Two Stage Operating, Pressure Reducing and Pressure Sustaining. No slam operation Exceptionally low losses at high flow conditions Easy installation and maintenance The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by an electric solenoid valve with adjustable open close speed control valves. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Main Valve Self-flushing filter Cock valve* / Solenoid valve Accelerator relay (optional for valves larger than 0mm/6 ) 6 Open/close speed adjustment needle valve 7 Check valve 8 Limit switch assembly Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) extended for longer pipe The valve should be suited for the maximal flow Closure time is related to the pipe length and should be For power failure situations, add a fast reacting checkvalve in series and a surge anticipating valve to relief possible surges Dorot Booster Pump Control Valve preventing surges caused by pump startup and shutoff and drainage of main pipe.

DW Deep Well (Borehole) Pump Control Valve 6 7 6 8 The valve eliminates surges caused by the start-up and shut-off of vertical or submersible pumps. It is a relief valve, assembled on a T-junction of the main pipeline. When the pump starts, the valve slowly closes, gradually increasing network pressure. Before pump shut-off, the valve slowly opens, gradually reducing network pressure. No slam operation Easy installation and maintenance Low Resistance and high flow capacity The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be controlled by an electric solenoid valve with adjustable open/ close speed control valves. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Main Valve Self-flushing filter Cock valve* / Solenoid valve Accelerator relay (optional for valves larger than 0mm/6 ) 6 Open/close speed adjustment needle valve 7 Check valve 8 Limit switch assembly The valve should be sized to match the well flow at mwc/8 psi in the valve site (pump head water table depth): D[mm] 70 x Flow [m/hr] D[inch] 0. x Flow [gpm] extended for longer pipe The valve should be suited for the maximal flow Closure time is related to the pipe length and should be For power failure situations, add a fast reacting checkvalve in series and a surge anticipating valve to relief possible surges Dorot Deep Well Pump Control Valve preventing surges caused by pump start-up or shut-off.

RE Surge Anticipating Valve 7 6 6 The valve protects the pumping system from water hammer, caused by sudden pump shut-off (case of power failure, for example). The valve is assembled on a T-junction of the main pipeline, instantly opens when the pump stops, relieving the returning high pressure wave. The valve slowly closes once the pressure returns to the static level. The valve also functions as a pressure relief valve. No slam operation Easy installation and maintenance Low Resistance and high flow capacity Protection for sewage as well as clean water pumping systems Main Valve Self-flushing filter Cock valve* Low-pressure relief pilot valve High-pressure relief pilot valve 6 Needle valve 7 Pressure gauge The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by pressure relief pilot valve for opening at a low pressure set point and another pilot for pressure relief at a high pressure set-point. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. The valve should be sized to match the 80% of the normal flow at static head in the valve site: D[mm] (0 x Flow[m/hr] / Pressure[mwc]) D[inch] (0.09 x Flow[gpm] / Pressure[psi]) the valve position extended for longer pipe Install a manual separation/throttling valve, upstream of Closure time is related to the pipe length and should be The valve sensor tube must be connected to the main line Dorot Surge Anticipating Valve prevents water-hammer surges caused by an un-expected pump shut-off. 6

QR Quick Pressure-relief Valve The valve opens instantly when the pressure in the pipeline exceeds the safe level, thus relieving excessive pressure from the network. When the pressure returns to normal, the valve closes slowly, at an adjustable pace. No slam operation Easy installation and maintenance Low Resistance and high flow capacity Protection for sewage as well as clean water pumping systems Main Valve Self-flushing filter Cock valve* Pressure relief pilot valve Needle valve The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve will be operated by a pressure relief pilot valve for fast opening at a high pressure set-point. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. The valve should be sized to match the expected relief flow at the set opening pressure: D[mm] (0 x Flow[m/hr] / Pressure[mwc]) D[inch] (0.09 x Flow[gpm] / Pressure[psi]) position extended for longer pipe Install a manual separation valve, upstream of the valve Closure time is related to the pipe length and should be The valve opens instantly at the set pressure. For regulating the system pressure use a Pressure Sustaining Relief Valve and not a Quick Relief valve Dorot Quick Pressure-relief Valve protects a system against pressure surges caused by pump start-up or valves closure. 7

TO Two Stage Opening Addition The device can be added to any control function and will prevent damage caused by too fast filling of a drained pipeline. The flow rate will be restricted, until the network, downstream of the valve is full and than a full opening of the valve is enabled. Please consult DOROT for more details. Can be added to any pipe-filling control function User adjusted filling pace Completely hydraulic no electronic controllers, batteries or relays are used Main Valve Self-flushing filter Cock valve* Pilot valve -way selector valve* The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve s opening will be restricted by a two-stage opening control that limits the filling flow until the downstream system is full. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Prefer selection low pressure diaphragms when the valve is expected to stay in open position for long periods Dorot two-stage function prevents water-hammer/surges caused by fast drained pipe filling. 8

SP Surge Preventing Stepped-Closure Addition The device can be added to any control function and automatically adjusts the closing speed of a valve that is located at the end of a long pipeline. This ensures a moderate flow change pace that prevents pressure surges from evolving. Please consult DOROT for more details Can be added to any fast closing control function Automatically self-adjusted closing pace Completely hydraulic no electronic controllers, batteries or relays are used Main Valve Self-flushing filter Cock valve* Stepped closure adjusting pilot valve -way selector valve* The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve s closure pace will be controlled by a stepped closure control pilot that stops the closing procedure whenever surge waterhammer conditions evolve. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Prefer selection low pressure diaphragms when the valve is expected to stay in open position for long periods Should be used whenever the supply pipe is longer than km/. mile and the flow speed exceeds. m/sec Dorot stepped closure function prevents water-hammer surges caused by fast closing level control valve. 9

EC PLC Controlled Valve The valve is controlled by a PLC controller that enables local or remote control of various functions such as, time related operation, the batching of liquid, and conditional (automatically modified) control parameters, in various applications. A recommended option is using the Dorot ConDor controller that enables the selection from a vast range of pre-programmed control functions and their combinations. Can perform any control function Highly accurate and reliable electronic control Low power actuation Controlled by Dorot ConDor valve controller or by a third party controller Main Valve Self-flushing filter Cock valve* /, NC solenoid valve -way selector valve* The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located within the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve position will be determined by a set of two solenoid valves controlled by a PLC controller. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for continuous operation. m/sec (8 ft/sec) allowed headloss The valve should be suited for the maximal flow and Solenoid wiring diameter should be selected so that the activation voltage - losses will equal the rated value ±0% Dorot PLC Controlled Valve adjusts the flow rate following a set-point signal sent from a remote center. 0

DE Deluge Dry-pipe and Pre-action Valves 6 The valve prevents flow of water into fire extinguishing sprinklers system until it is activated by the activation devices. Different valve and control system configurations are available to meet the customer and relevant standards demands. Please check Dorot Fire-Fighting publications for further information. Fast opening Automatic reset Wide range of applications UL Approval no. VLFT EX.6 Main Valve Self-flushing filter Manual activation valve Solenoid activation* Pilot activation (by detection line)* 6 Drain valve The valve will be hydraulic, direct sealing diaphragm type, which allows inline maintenance. No stem, shaft or guide bearing will be located with in the water passage. The valve will be activated by the line pressure or by an external hydraulic or pneumatic pressure. The valve and the controls will be a Dorot Series 00 valve or similar in all aspects. Valve size same as line or one size smaller Maximum flow speed for intermittent operation 8 m/sec (6 ft/sec) allowed headloss The valve should be suited for the maximal flow and Check Dorot catalogue for Fire Fighting Valves for more information with regards to valve and applications types Dorot valve, activated by a splinker detection line.

Pilots and Accessories Plastic Mini Pilots For valve sizes 0mm to 00mm - / to Pressure rating: 0 bar / psi 9-00 -way pressure reducing pilot valve 9-00 -way multi purpose (pressure reducing and sustaining) pilot valve 9-00 way differential multi purpose (flow control, differential pressure sustaining) Metal Mini Pilots For valve sizes 0mm to 0mm - / to 6 Pressure rating: bar / 60 psi 68-0 -way pressure reducing pilot valve 68-00 -way pressure sustaining pilot valve 68-0 -0 R/F/S -way (pressure rating 6bar / 0psi) pressure reducing pilot valve -way multi purpose (pressure reducing and sustaining, flow-control) pilot valve Metal Pilots For valve sizes 0mm to 600mm - / to Pressure rating: bar / 60 psi CXPR -way pressure reducing pilot valve (CXRS - remote sensing, CXRD differential pressure reducing) CXPS -way pressure sustaining pilot valve (CXSD differential pressure sustaining) -0 -way multi purpose (pressure reducing and sustaining) pilot valve 76-00 way differential multi purpose (flow control, differential pressure sustaining) 68-70 -way pressure sustaining pilot valve High Sensitivity Metal Pilots For valve sizes 0mm to 600mm - / to Pressure rating: bar / 60 psi way differential multi purpose (flow control, altitude 70-0 control and differential pressure sustaining) with adjustable differential -way differential pressure reducing mini pilot valve 70-0 (flow control and altitude control) -0H -way pressure reducing and differential control 9-00 9-00 9-00 68-0 68-00 68-0 -0R -0F CXPR CXPS -0 76-00 68-70 70-0 70-0 -0H Float Pilots For valve sizes 0mm to 600mm - / to Pressure rating: bar / 60 psi 70-00 Electric float 70-0 Vertical, differential, and -way metal float pilot 70-00 Modulating, -way plastic float pilot for irrigation use (pressure rating: 8 bar / psi) 70-00 Modulating, -way metal float pilot 70-60 Horizontal, differential, -way metal float pilot 70-00 70-0 70-00 70-00 70-60

Pilots and Accessories Plastic Relays For valve sizes 0mm to 0mm - / to 6 Pressure rating: 0 bar / psi -00 -way / positions NO w. /8" ports hydraulic relay Galit -way / positions NC or NO, small hydraulic relay -00 Galit Metal Relays For valve sizes 0mm to 600mm - / to Pressure rating: bar / 60 psi 66-0 -way / positions NO (66-: NC) hydraulic relay 66-00 -way adjustable hydraulic relay 8-00 -way / positions hydraulic relay 8-00 -way / positions hydraulic relay 66-0 66-0 8-00 8-00 Mini Solenoids For irrigation valve sizes 0mm to 0mm - / to 6 Pressure rating: 0 bar / psi Operating Voltage: AC: V DC: V or V Latch 7.-0V D -way NC solenoid valve D -way NC or NO solenoid valve D D Heavy-duty Solenoids For valve sizes 0mm to 600mm - / to Pressure rating: According to the selected orifice and solenoid type Operating Voltage (others available upon request): AC: V, 0V or 0V DC: V or V Latch 9V, V, V B -way NC or NO solenoid valve B -way NC or NO solenoid valve B B Control Filters Self-Flushing, Inline - Stainless steel screen filter, located within the main valve, and rinsed continuously by the stream Sizes: /, / External, Y type - Stainless steel screen installed in a Y shaped body on the pressure source. Sizes: / 8, / External, large - A large volume external filter Y Filter Self-Flushing Filter

Other Dorot Products Automatic Control Valves Series 00 - Disc seal, Globe type valve. Very accurate regulations at near zero flow conditions. Minimum head-loss while fully open. Available in sizes:. (0mm) - (800mm). Glass Reinforced Nylon Valves - Diaphragm sealing valves made of reinforced Polyamide used in Greenhouses, Field Crops, Irrigation, Landscaping, Water Treatment (non corrosive). Available in sizes: / (0mm) - (80mm). Series 00 - Disc seal, Y type valve. This valve is compact, partially made of new composite materials. Wide range of flow and pressure regulation. Available in sizes:. (0mm) - 8 (00mm). Back Flushing Valves - Specially designed valves for back flow flushing of filtration systems. Available in Cast Iron or Glass Reinforced Nylon, Single or Double chamber operation. Available in sizes: (0mm) - (00mm). upvc Valves - Diaphragm sealing valves made of upvc. For use with aggressive water and with underground (PVC) piping. Available in sizes: (80mm) - 6 (0mm). Manual Valves Air Release Valves Butterfly Valves - Soft sealing valves (Wafer type) with options of gear, lever (or other) operation. Available in sizes: (0mm) - (600mm). Non Metal Air Release Valves - Kinetic, Automatic and Combination Air Release Valves made of Polypropylene materials. Available in sizes: / (mm) - (0mm). Non Return Valves - Swing check valves, tilting disc check valves, double flap check valves. Ductile Iron Air Release Valves - Kinetic, Combination and Sewage Air Release Valves made of ductile iron. Option for surge arrestor feature. Available in sizes: (0mm) - (00mm). Gate Valves - Valves with soft and resilient or rigid sealing. Water Meters Water Meters - Multi-Jet, Single-Jet, Irrigation Meters (pelton wheel type), Woltman Meters and Volumetric Meters. Available in sizes: / (mm) - (600mm).

s

DOROT AUTOMATIC CONTROL VALVES Founded in 96, DOROT is a leading developer, manufacturer and marketer of a wide range of superior quality automatic control valves. DOROT s experienced Research & Development Dept. has a long tradition of generating innovative solutions for the application of water control systems. These include, waterworks distribution networks, sewage and effluent disposal, fire protection, mining and irrigation systems. DOROT s commitment to excellence begins with using the highest quality materials. The company s engineering experts are constantly working to provide customers with a broad range of valve patterns and sizes in a wide variety of metals and grades including: Cast Iron, Ductile Iron, Cast Steel, SST, Bronze, Marine Bronze, Polyamide and P.V.C. The experts at DOROT custom-design each valve application according to specific control requirements. Most of the production process, which includes machining and coating, takes place in modern in-house facilities. Before leaving the factory, each product is hydraulically tested. An advanced testing laboratory simulates the anticipated field conditions. With distribution in more than 70 countries world-wide, a key component of the DOROT difference is its outstanding customer service. This includes field assistance, technical advice, training programs and follow-up consultations. It is all of these factors that make DOROT a leader in fluid control technology and customer satisfaction. www.dorot.com E-mail: info_d@dorot.com