The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector

Similar documents
Liquefied Gas Injector. Solution for the Sampling and Analysis of Liquefied Gases

Refinery Gas. Analysis by Gas Chromatography WASSON - ECE INSTRUMENTATION. Engineered Solutions, Guaranteed Results.

C2, C3, C4 Monomer Analysis

Fast and Reliable Trace Gas Analysis Improved Detection Limits for the Agilent 490 Micro GC

Application Note. Determination of Oxygenates in C2, C3, C4 and C5 hydrocarbon Matrices according ASTM D using AC OXYTRACER

DANI Transformer Oil Gas Analyzer

Gas Chromatographic Analysis of Diesel Fuel Dilution for In-Service Motor Oil Using ASTM Method D7593

Beverage Grade Carbon Dioxide

High Throughput Mineral Oil Analysis (Hydrocarbon Oil Index) by GC-FID Using the Agilent Low Thermal Mass (LTM) System

High Temperature Simulated Distillation Performance Using the Agilent 8890 Gas Chromatograph

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers. Versa HT3. Application Note. Abstract.

Detection of Sulfur Compounds in Natural Gas According to ASTM D5504 with an Agilent Dual Plasma Sulfur Chemiluminescence Detector

Operation and Applications of Differential Flow Modulation

ANALYSIS AND MANAGEMENT OF GAS PROCESSES FROM REMOTE

Alternative Carrier Gases for ASTM D7213 Simulated Distillation Analysis

Achieving Higher Sensitivities Using GC-FID with the Agilent Multimode Inlet (MMI)

Application Note. Abstract. Authors. Environmental Analysis

Analysis of Petroleum Fractions by ASTM D2887

Sulfur Detection at ppb Levels in Light Hydrocarbon Streams

Antek Gas Chromatography Products: A Guided Tour Through Industry

TURN-KEY ANALYZERS SUPERIOR PETROCHEMICAL SOLUTIONS SOLUTIONS SPECIAL APPLICATIONS

Fast Simulated Distillation Based on Agilent 6890N Gas Chromatograph Application

Live Crude Oil Volatility

Experience the Difference

Live Crude Oil Volatility

Impact of GC Parameters on The Separation Part 2: Choice of Column Internal Diameter

Technical Procedure for Gas Chromatography (GC-FID)

Oxygenates in Fuels Analysis Solutions From Trace Levels to Ethanol Fuels

gc applications Hydrocarbons C1-C5 Paraffins Hydrocarbons, Sulfur Gases C1-C2 Hydrocarbons Gases

performance productivity reliability

White Paper. Improving Accuracy and Precision in Crude Oil Boiling Point Distribution Analysis. Introduction. Background Information

Using a New Gas Phase Micro-Fluidic Deans Switch for the 2-D GC Analysis of Trace Methanol in Crude Oil by ASTM Method D7059 Application

GC Method Compliance and Large Valve Oven Application

PRODUCT SPECIFICATION. Product Specification Crystal 9000 Gas Chromatograph. Chromatec Crystal Laboratory Gas Chromatography System

Agilent Multimode Inlet for Gas Chromatography

Setting up SilFlow for BackFlush in your GC

Application. Gas Chromatography June 1995

Free and Total Glycerol in B100 Biodiesel by Gas Chromatography According to Methods EN and ASTM D6584

Application Note. Author. Introduction. Energy and Fuels

Rapid Qualitative GC-TOFMS Analysis of a Petroleum Refinery Reformate Standard

Stability, Linearity and Repeatability of Nitrogen Determination by Flash Combustion using Argon as Carrier Gas

S-PRO 3200 GC System for Sulfur Analysis

Siemens AG, 2008 MAXUM II

Increased sensitivity and reproducibility in the analysis of trace fatty acid methyl esters in jet fuel

Using the PSD for Backflushing on the Agilent 8890 GC System

Dual Channel Simulated Distillation of Carbon and Sulfur with the Agilent 7890A GC and 355 Sulfur Chemiluminescence Detector

DETERMINATION OF N-BUTANOL AND ISOBUTANOL IN GASOLINE USING GAS CHROMATOGRAPHY (GC-FID)

GAS CHROMATOGRAPHY: INJECTION TECHNIQUES CAPILLARY COLUMNS

MET-Biodiesel Capillary GC Columns

Technical Procedure for Gas Chromatography-Mass Spectrometry (GC-MS)

6. Lone Star NGL Mont Belvieu LP E/P Mix November 16, Lone Star NGL Mont Belvieu LP Refinery Grade Butane November 29, 2012

SELERITY TECHNOLOGIES SOLUTIONS FOR YOUR SUPERCRITICAL FLUID NEEDS

Fausto Munari e Andrea Cadoppi ThermoFisher - Italy

Agilent and ASTM. Update on Recent Activities. Page 1

IGS-M-CH-058(0) Mar Approved مصوب IGS. Propane, Buthane and LPG Specifications. Fax:(9821)

Irving Oil Whitegate Refinery Limited

CHEVRON PHILLIPS CHEMICAL PIPELINE COMPANY LLC PETROCHEMICAL PRODUCTS (AS DEFINED HEREIN)

Analytical and Testing Instruments for the HPI Market Shimadzu s Total Solutions for the Hydrocarbon Processing Industry

Module8:Engine Fuels and Their Effects on Emissions Lecture 36:Hydrocarbon Fuels and Quality Requirements FUELS AND EFFECTS ON ENGINE EMISSIONS

Page 1. Alternate Carrier Gas Considerations and Faster GC Analysis

Method Detection Limits for EPA Method 8015 Diesel Range Organics using Fully Automated Extraction and Concentration

Technical Procedure for Pyrolysis-Gas Chromatography/Mass Spectrometry (Py-GC-MS)

High-Temperature Simulated Distillation System Based on the 6890N GC Application

Agilent 7693A Automated Liquid Sampler

Agilent Solutions for the Analysis of Ethanol- Based Fuels Derived From Biomass. James D. McCurry, Ph.D. Senior Scientist

GC/MS Analysis of Trace Fatty Acid Methyl Esters (FAME) in Jet Fuel Using Energy Institute Method IP585

ASTM D2887 Simulated Distillation Calibration Mixture Analysis Using a Differential Acceleration Column

Agilent Portfolio. Luca Godina. Technical Marketing Specialist GC-GCMS

ASTM D 6730 Detailed Hydrocarbon Analysis

Large Volume Injection of Polycyclic Aromatic Hydrocarbons

Mineral Turpentine Adulterant in Lubricating Oil

Refinery Support from the R&D Laboratory Perspective using Fast & Micro Gas Chromatography

Determination of Free and Total Glycerin in Pure Biodiesel (B100) by GC in Compliance with EN 14105

High Sensitivity UHPLC-DAD Analysis of Azo Dyes using the Agilent 1290 Infinity LC System and the 60 mm Max-Light High Sensitivity Flow Cell

Model 8610C Gas Chromatograph. GC Chassis Types ECD PID FID / DELCD FPD. Mounts up to Six Detectors and Five Injectors

Analysis and. Separation of Oxygenates in Hydrocarbon Matrices. Simon Jones Application Engineer Folsom, CA

Agilent 7693A Automated Liquid Sampler

Performing ASTM 6584 free and total glycerin in BioDiesel using an SRI Gas Chromatograph and PeakSimple software

Optimizing Ultra Fast Simulated Distillation with a Low Thermal Mass (LTM) GC System. Jim McCurry Roger Firor Agilent Technologies Wilmington, DE

Oil & Gas. From exploration to distribution. Week 3 V19 Refining Processes (Part 1) Jean-Luc Monsavoir. W3V19 - Refining Processes1 p.

Phillips 66 Pipeline LLC. Blue Pipeline Natural Gas Liquids Specifications

ANALYSIS OF GASOLINE RANGE HYDROCARBONS ON BP1-PONA

Detection of Volatile Organic Compounds in Gasoline and Diesel Using the znose Edward J. Staples, Electronic Sensor Technology

Application Note. Author. Abstract. Energy & Chemicals - Petrochemicals. Edgar Naegele, Agilent Technologies, Inc. Waldbronn, Germany

Group-Type Analysis (PiPNA) in Diesel and Jet Fuel by Flow Modulated GCxGC FID.

One-Minute Essential Oils Characterization by Gas Chromatography through Nanovolume Injection

Supply of Services for Detailed OEB Crude Assay Analysis

SPECIFIC ADDITIVE FOR PROTECTING AND CLEANING LPG FUEL SYSTEMS. The deposits observed on certain elastomeric parts are particularly crucial.

ANNEX 2, REFERENCE FUELS

Achieving Lower Detection Limits Easily with the Agilent Multimode Inlet (MMI)

Determination of fuel system icing inhibitor content of aviation turbine kerosine by HPLC

Agilent 7696A Sample Prep WorkBench Automated Sample Preparation for the GC Analysis of Biodiesel Using Method EN14105:2011

Agilent 6850 Series II Network GC System G2630A Performance Specifications

Characterization of Tiki Torch Fuels

Dual Plasma Sulfur and Nitrogen Chemiluminescence Detectors. Unsurpassed Stability, Selectivity, and Sensitivity for your GC Analysis

GC Analysis of Total Fatty Acid Methyl Esters (FAME) and Methyl Linolenate in Biodiesel Using the Revised EN14103:2011 Method

Application Note. Authors. Abstract. Energy & Chemicals

Sampling Methods for Dissolved Gases

Optimized Supercritical Fluid Chromatographic Instrumentation for the Analysis of Petroleum Fractions

ANNEX 3 REFERENCE FUELS. Parameter Unit Limits (1) Test method Minimum Maximum Research octane number, RON

Transcription:

Authors: The Analysis of Hydrocarbon Composition in LPG by Gas Chromatography using the DVLS Liquefied Gas Injector Introduction Specification of the hydrocarbon composition of LPG is required as traces of hydrocarbon impurities in LPG can negatively effect the fuel quality and processing. The compound distribution data of the hydrocarbons can also be used to calculate properties including relative density, vapor pressure, and motor octane number. This application note describes the gas chromatographic analysis of the hydrocarbon composition of LPG using the DVLS Liquefied Gas Injector (LGI). Application Note Anita Ruissen PhD, Application Specialist of Da Vinci Laboratory Solutions Analysis of LPG Various standard test methods for determining the hydrocarbon composition of liquefied petroleum gases are available, such as ASTM D2163 and ISO 7941. Both of these methods use gas chromatography as the analysis technique. Introduction of the liquefied gas sample into the GC inlet is most commonly performed by means of a liquid sampling valve. Da Vinci Laboratory Solutions developed the Liquefied Gas Injector, a closed system for the direct injection of liquefied petroleum gases into the GC inlet. The LGI instrument was introduced in 2010. It was originally developed for the analysis of oily residue (range C10-C40) in LPG. This method has been approved as ASTM D7756 and EN 16423. In the current study the LGI injector is applied for determining the hydrocarbon composition of LPG samples with various compositions. Application Description The LGI consists of an Injector, a Pressure Station and a Controller. The Injector is configured on top of the GC inlet as displayed in Figure One. The Pressure Station is installed next to the GC and ensures that the Injector is filled with the sample in liquid phase. The Controller box drives the injection cycling. The Injector includes the proven fuel direct injection technique used by the automotive industry to inject fuel into the automotive engine combustion chamber. The liquid sample is injected directly with a needle into the inlet similar as with an automatic liquid sampler. This avoids contact of the sample with transfer lines, vaporizers or valves and allows a good sample transfer into the heated zone of the inlet. Analytical Results For each sample the Normalized Volume percentages (Norm. Vol. %) of the individual compounds are calculated according to ASTM D2163. The Theoretical Volume Response factors (RRFis) as specified in D2163 are used. For certain compounds these values are not mentioned in this method. In these instances the RRFis are calculated using the sources D2163 refers to. Boosting Laboratory Efficiency

Sample cylinder Injector Injector Controller Instrument Configuration and Settings LGI Inject pulse 15 ms GC Inlet Inlet temperature Oven SSL 240 C Propane, Propylene & Butane: 40 C (8 min) 200 C, 8 C/min Pentane: 50 C (3 min) 270 C,10 C/min Split ratio 1:1 Pressure Station Figure One: DVLS Liquefied Gas Injector installed on the GC Column Carrier Column flow Alumina Plot Helium 5 ml/min ASTM D2163 applies to compound concentrations in the range of 0.01 to 100 volume percent (Vol %). ISO 7941 applies to concentrations > 0.1 mass percent. Based on the reported chromatograms the Limits of Detection (LOD) are calculated. The LOD is defined as 10 times the standard deviation of the noise. The LODs of all compounds detected in the LPG samples are at least 10 times lower than the lower value D2163 applies to. Most values were even 50 to 300 times lower. This indicates that the current technique offers an excellent sensitivity for determination of hydrocarbons in LPG. Repeatability is determined by performing seven analyses of the automotive LPG sample. For the major compounds; Propane, i-butane and n-butane, the Relative Standard Deviation (RSD) varies between 0.2 and 0.6 %. For the trace compounds with concentrations > 0.01 Vol. % the RSD varies between 0.2 to 2.5 %. Detector FID Table One: Instrument Configuration and Settings References: 1. ASTM D7756-13 :Standard Test Method for Residues in Liquefied Petroleum (LP) Gases by Gas Chromatography with Liquid, On-Column Injection 2. Application note: The Analysis of Liquid Ethane by Oncolumn Gas Chromatography with the DVLS LGI Injector 3. Application note: The Analysis of Di-Iso-Propanol- Amine (DIPA) in Liquefied Petroleum Gas (LPG) with the DVLS LGI Injector 4. Application note: Dual Analysis of Oily Residues in LPG (ASTM D7756/EN 16423) and Hydrocarbon Composition of LPG (ASTM D2163 & ISO 7941) Conclusion In the current study the LGI-GC technique has been applied for the analysis of the hydrocarbon composition of LPG samples. The analytical results demonstrate an excellent sensitivity.

Figure Two: Chromatogram of the LGI analysis of automative LPG Average RSD LOD Norm. Vol. % Norm. Vol% Methane 0.0001 13.9 0.00006 Ethane 0.0166 0.9 0.00004 Propane 71.8904 0.2 0.00055 Propylene 0.0712 0.2 0.00005 i-butane 3.8319 0.4 0.00012 n-butane 23.7136 0.6 0.00030 tr-butene 0.0414 1.2 0.00004 Butene-1 0.0219 1.1 0.00004 i-butene 0.0131 1.8 0.00004 c-2-butene 0.0287 1.3 0.00004 i-pentane 0.1005 1.7 0.00005 n-pentane 0.2359 1.4 0.00006 1,3-Butadiene 0.0347 2.5 0.00004 Table Two: Results of 7 LGI analyses of automative LPG

Figure Three: Chromatogram of the LGI analysis of liquefied Propylene LOD Methane 0.0001 0.00010 Ethane 0.0126 0.00004 Ethylene 0.0004 0.00006 Propane 5.7348 0.00019 Propylene 94.2447 0.00054 i-butane 0.0013 0.00006 n-butane 0.0019 0.00005 tr-butane 0.0005 0.00003 Butene-1 0.0004 0.00004 i-butene 0.0005 0.00003 c-2-butene 0.0003 0.00003 n-pentane 0.0007 0.00004 1,3 Butadiene 0.0018 0.00004 Table Three: Results of the LGI analysis of liquefied Propylene

Figure Four: Chromatogram of the LGI analysis of liquefied Propane LOD Methane 0.0107 0.00006 Ethane 0.0795 0.00005 Propane 97.6246 0.00085 Cyclo-Propane 0.1907 0.00008 Propylene 0.9730 0.00016 i-butane 1.0182 0.00014 n-butane 0.0573 0.00007 tr-butane 0.0001 0.00005 Butene-1 0.0001 0.00005 i-butene 0.0008 0.00005 c-2-butene 0.0448 0.00006 n-pentane 0.0000 0.00006 1,3-Butadiene 0.0003 0.00005 Table Four: Results of the LGI analysis of liquefied Propane

Figure Five: Chromatogram of the LGI analysis of liquefied Butane LOD Methane 0.0019 0.00004 Ethane 0.0063 0.00004 Propane 1.0238 0.00011 Propylene 0.0014 0.00003 i-butane 31.7849 0.00028 n-butane 66.3553 0.00045 tr-butane 0.0120 0.00004 Butene-1 0.0111 0.00004 i-butene 0.0218 0.00004 c-2-butene 0.0068 0.00003 i-pentane 0.1928 0.00006 n-pentane 0.5196 0.00007 1,3-Butadiene 0.0623 0.00004 Table Five: Results of the LGI analysis of liquefied Butane DA VINCI LABORATORY SOLUTIONS B.V. P.O. Box 12103, 3004 GC Rotterdam - The Netherlands T: +31 (0)10 258 1870 - F: +31 (0)10 258 1879 - E-mail: solutions@davinci-ls.com www.davinci-ls.com