MityFlex Peristaltic Pump

Similar documents
BASIC SYSTEM ASSEMBLY INSTRUCTIONS

Horizontal Tissue Bath BASIC SYSTEM ASSEMBLY INSTRUCTIONS

MPM-20 INSTRUCTION MANUAL

MMP/DMP Manual Microsyringe Pumps

Mini-Star Miniature DC Peristaltic Pump

Peri-Star TM PRO High Performance digital peristaltic pump

MMP & DMP. Manual Microsyringe Pumps INSTRUCTION MANUAL. Serial No. World Precision Instruments

MPM-20. Piezo translator for M3301 and DC3001 micromanipulators INSTRUCTION MANUAL. Serial No. World Precision Instruments

PUL-1000 Microprocessor-controlled 4-Step Micropipette Puller

BASIC SYSTEM ASSEMBLY INSTRUCTIONS

MF200 Microforge with 40 long working distance objective

D2H and D2H-2. Deuterium-Halogen Light Sources. INSTRUCTION MANUAL. Serial No. World Precision Instruments

SP101i Syringe Pump INSTRUCTION MANUAL. World Precision Instruments, Inc. SP101i Syringe Pump. Digital Infusion Syringe Pump. Serial No.

UV PROCESS SUPPLY, INC. CON-TROL-CURE

EndOhm Tissue resistance measurement chambers for tissue culture cups

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

PERISTALTIC DOSING PUMP OPERATING MANUAL. MODEL: FS SERIES Fixed Speed Peristaltic Pump

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

PUL Microprocessor-controlled 4-Step micropipette puller INSTRUCTION MANUAL. Serial No. World Precision Instruments

Installation & Operation Manual Chef Base

Raydot LLC 24 Actuator (115 VOLT)

MITYFLEX PERISTALTIC PUMPS

ADI-125/750 ADI-125/1500 ADI-125/2500

DC to AC Power Inverters

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

DC to AC Power Inverters

OWNERS MANUAL JANUARY 2007 ISO

HA/HAB Fiberglass Wall Mount Ventilators

Operator s Manual Version 1.21 TR-200. Peristaltic Pump. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

Installation & Operators Manual

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

24 Linear Actuator 115 Volts A.C. (Cat. # C430A)

OWNERS MANUAL JANUARY 2007 ISO

STC 2L Series Solenoid Valves

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Users Guide for Ac-sync

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

MIL-24/2600Q MIL-24/3200DQ

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Float Level Control Kits

2V1-3V1 SERIES SOLENOID VALVE

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Junior Sandblaster. Model #51 WARNING! FOR YOUR SAFETY PLEASE READ INSTRUCTIONS BEFORE OPERATING TOOL & WEAR EYE PROTECTION

AirTherm. Heater controller for bioscience laboratories. INSTRUCTION MANUAL. Serial No. World Precision Instruments


Operations and Parts Manual

STC 2W Series Solenoid Valves

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

Thermaltake Warranty / Support Information

Air Curtain. Installation, Operating and Maintenance Instructions

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

PVI 60KW, PVI 82KW, PVI 95KW

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Car Vacuum Cleaner #CarVac

Instruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:

Heavy Duty Four Wheeled Walker

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Model C230 Pump Controller

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

NEUTRALIZATION SYSTEM FOR OPA & GLUTARALDEHYDE MEDI-NEWT. User Manual. Endoscope reprocessing the the way way it it should be be

STC 2DS Series Anti-Hammering Slow Closing Pilot Solenoid Valves

Thermo Fisher Scientific (U.S. and Canada only) 11 (847) (Outside U.S.) (847) (Local)

STC 2P025 Series Solenoid Valve

3V SERIES SOLENOID VALVE

BroadBand PowerShield. 20 AHr Battery. User Manual

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

FD Conveyor for FD 260 Tabber

ProFlo FatBoy

STEEL PIPE NIPPLES - WELDED Price Sheet PNW-7.18 Effective: July 16, 2018 Cancels Price Sheet PNW-3.18 of March 5, 2018

PARTS MANUAL 360 ROTATOR MODEL NUMBER R Industrial Way Lebanon, Oregon FORKLIFT ATTACHMENTS

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

ST-70 CONTROL OPERATING MANUAL REVISION DATE: PART#:

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

SUBMERSIBLE MINI-PUMP

EQUIPMENT OPERATION MANUAL. Loctite ZETA 7401 UV Chamber

TL-105-D COLUMN HEATER

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

HP190SL Series Slimline Radon Fans

4-SIDED HOCKEY SCOREBOARD LED BAR DIGIT INSTRUCTION MANUAL REVISION DATE: PART#:

INW Panel Meter Reading an INW PT12 Sensor

Cable Length Meter INSTRUCTION MANUAL

4V130P-430P SERIES AIR PILOT VALVE

In-Line Linear Actuator

Parts Manual Vermeer/ McLaughlin Mud System 230P

STC E-Series Electrically Actuated Ball Valves 316 Stainless Steel, 2-Way or 3-Way

BCFS Belt Driven Centrifugal Filtered Supply Fans

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

PORTABLE TUBING PUMP MANUAL

Parts Manual V100G Vacuum Machine Part #E (SERIAL #1G G )

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

CRD400 Fitting Inserter OPERATIONS MANUAL

Loctite Spray Valve Controller Part Number EQUIPMENT Operation Manual

INSTALLATION INSTRUCTIONS

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

User s Manual and Operating Instructions

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

"WHERE TUBING AND FITTINGS COME TOGETHER"

Transcription:

WORLD PRECISION INSTRUMENTS Instrumenting scientific ideas INSTRUCTION MANUAL MityFlex Peristaltic Pump Serial No. www.wpiinc.com 0536

MityFlex CONTENTS ABOUT THIS MANUAL... INTRODUCTION... SPECIFICATIONS... 2 OPERATING INSTRUCTIONS... 3 Installation... 3 Roller/Tubing Selection... 3 Variable Speed... 3 Tubing Installation... 4 Alternate Tubing Installation Procedure... 4 Fuse Installation... 5 Motor Brush Replacement... 5 DECLARATION OF CONFORMITY... 6 WARRANTY... 7 Claims and Returns... 7 Repairs... 7 Copyright 206 by World Precision Instruments, Inc. All rights reserved. No part of this publication may be reproduced or translated into any language, in any form, without prior written permission of World Precision Instruments, Inc. World Precision Instruments i

ii World Precision Instruments

MityFlex ABOUT THIS MANUAL The following symbols are used in this guide: This symbol indicates a CAUTION. Cautions warn against actions that can cause damage to equipment. Please read these carefully. This symbol indicates a WARNING. Warnings alert you to actions that can cause personal injury or pose a physical threat. Please read these carefully. NOTES and TIPS contain helpful information. INTRODUCTION MITYFLEX variable speed drive is powered by DC gearmotors. A specially designed electronic speed control system provides smooth acceleration control over the entire flow range. The three position on/off switch allows the user to maintain speed setting when unit is turned off or reversed. This unit is designed for continuous operation at any speed. World Precision Instruments

SPECIFICATIONS ELECTRICAL: 5 VAC, 60 Hz PRIMING: Unit is self priming and will hold vacuum when off. OPERATION: Pump can run dry without damaging the motor or drive unit, however the tubing life will be reduced. CONSTRUCTION: High impact plastic and long lasting alloy metals housed in a steel enclosure. MAX. HEAD PRESSURE: 40 PSI. Normal pressure 8 PSI varies depending on tubing used. MAX. SUCTION LIFT: 29 feet (8.8m) with H 2 O. RATING: 00% continuous operation at maximum of 40 C ambient. FLOW RATE: Variable speed drive system - reversible. FUSE: Located in the inlet receptacle. Uses 5 X 20mm -.0 amp. (See page 4 for replacement procedure.) DC MOTOR BRUSHES: Replaceable (See page 4 for replacement procedure.) WEIGHT: 3 lb Included with MityFlex are four short lengths of Norprene tubing to fit into the roller mechanism / 6, / 8, 3 / 6, / 4 and black rollers for use with 3 / 6 to / 4 tubing. The optional MITY-KIT includes replacement tubing and a set of red rollers for use with / 6 and / 8 tubing. FLOW RANGE: Tubing ID Flow (ml/min) / 6 (0.062 /.6mm).7-48.0 / 8 (0.25 /3.mm) 7.0-90.0 3 / 6 (0.87 /4.8mm) 6.0-456.0 / 4 (0.250 /6.4mm) 28.0-800.0 Flow range based on pumping water at 25 C and 0 PSI using 60 durometer thermoplastic elastomer tubing. 2 World Precision Instruments

MityFlex OPERATING INSTRUCTIONS Installation POWER REQUIREMENTS: Voltage and frequency of power supply must be the same as shown on unit. WIRING CONNECTIONS: All wiring and electrical connections must comply with local and national electrical codes. MOUNTING: Place on any flat surface. Ensure that space is provided at the back of the case for air circulation through ventilation holes. Do not allow tubing to be crimped. MOUNTING LOCATION: Pump should be placed in a dry location with adequate cooling provided. The ambient temperature should not exceed 40 C. This unit should not be used outdoors or in hazardous locations. Roller/Tubing Selection Use the following color coded rollers with the appropriate tubing I.D. Your unit is assembled with black rollers. Red rollers are included in the optional MITY-KIT. See separate instructions for roller replacement enclosed in your tube kit. Roller Tubing ID Tubing OD ml/revolution Black Black Red Red / 4 (0.250) 3 / 6 (0.87) / 8 (0.25) * / 6 (0.062)* 7 / 6 (0.438 /.mm) 3.5 3 / 8 (0.375 /9.5mm) 2. 3 / 8 (0.375 /9.5mm) 0.8 3 / 8 (0.375 /9.5mm) 0.2 * Red rollers for use with / 8 and / 6 tubing are included in the optional MITY-KIT. NOTE: The / 6 ID tubing is actually a small piece of tubing inside a larger piece. Variable Speed Variable speed control may be set at any level before turning unit on. Unit is designed for continuous operation at any speed. CAUTION: Avoid prolonged operation in the stalled position to ensure longer motor life. World Precision Instruments 3

Tubing Installation Inspect all tubing regularly and replace if any sign of deterioration occurs. Always wear safety glasses and protective clothing when working with chemicals.. Disconnect power to the pump. 2. Disconnect the suction and discharge tubing from the pump tubing. 3. Remove four thumb screws and pump cover. 4. Pull out old pump tubing and discard. 5. Clean roller race, removing any particles that could damage tubing. 6. Using extra bracket (Fig. ), rotate roller bracket assembly until it is in position as in Fig. 2. (Be sure power is disconnected.) 7. Push new tubing into inlet port, anchoring the tubing in grippers (see Fig. 3). If using 9 piece of tube, / 2 should be extended outside of inlet port. 8. Continue to rotate the roller bracket assembly using the extra bracket, while pushing the tubing into the roller race (Fig. 4). 9. Insert the tubing into the outer port (Fig. 5) and replace the cover and screws. Alternate Tubing Installation Procedure INLET PORT Without removing the pump cover, run the unit at high RPM. Pull the old tubing out from outlet port of pump. Install new tube by inserting into inlet port; continue feeding tube / 4 in at a time allowing the roller assembly to push tubing OUTLET PORT through. When tubing is half way around the race, Fig. 6 put your finger over the inlet hole of the tube and continue to feed tubing / 4 at a time; this should make installation easier. Continue until desired tubing extension is obtained. Run unit one minute. 4 World Precision Instruments

MityFlex Fuse Installation. Disconnect power to pump. 2. Find the power socket on the back of the case. 3. Pull the power cord out. 4. Slide the drawer below the receptacle out toward you. 5. Remove old fuse and replace with new fuse. 6. Push drawer in until it locks in place. Motor Brush Replacement. Disconnect power to pump. 2. Remove case cover by removing 8 screws. 3. With a flat head screw driver, remove the brush caps on both sides of the DC motor. 4. Remove old brush and replace with new brush. (Slide in horizontally) 5. Push metal plate on the end of the brush inside. Hold it while replacing brush cap. 6. Replace case cover. World Precision Instruments 5

DECLARATION OF CONFORMITY 6 World Precision Instruments

MityFlex WARRANTY WPI (World Precision Instruments, Inc.) warrants to the original purchaser that this equipment, including its components and parts, shall be free from defects in material and workmanship for a period of one year* from the date of receipt. WPI s obligation under this warranty shall be limited to repair or replacement, at WPI s option, of the equipment or defective components or parts upon receipt thereof f.o.b. WPI, Sarasota, Florida U.S.A. Return of a repaired instrument shall be f.o.b. Sarasota. The above warranty is contingent upon normal usage and does not cover products which have been modified without WPI s approval or which have been subjected to unusual physical or electrical stress or on which the original identification marks have been removed or altered. The above warranty will not apply if adjustment, repair or parts replacement is required because of accident, neglect, misuse, failure of electric power, air conditioning, humidity control, or causes other than normal and ordinary usage. To the extent that any of its equipment is furnished by a manufacturer other than WPI, the foregoing warranty shall be applicable only to the extent of the warranty furnished by such other manufacturer. This warranty will not apply to appearance terms, such as knobs, handles, dials or the like. WPI makes no warranty of any kind, express or implied or statutory, including without limitation any warranties of merchantability and/or fitness for a particular purpose. WPI shall not be liable for any damages, whether direct, indirect, special or consequential arising from a failure of this product to operate in the manner desired by the user. WPI shall not be liable for any damage to data or property that may be caused directly or indirectly by use of this product. Claims and Returns Inspect all shipments upon receipt. Missing cartons or obvious damage to cartons should be noted on the delivery receipt before signing. Concealed loss or damage should be reported at once to the carrier and an inspection requested. All claims for shortage or damage must be made within ten (0) days after receipt of shipment. Claims for lost shipments must be made within thirty (30) days of receipt of invoice or other notification of shipment. Please save damaged or pilfered cartons until claim is settled. In some instances, photographic documentation may be required. Some items are time-sensitive; WPI assumes no extended warranty or any liability for use beyond the date specified on the container Do not return any goods to us without obtaining prior approval and instructions from our Returns Department. Goods returned (unauthorized) by collect freight may be refused. Goods accepted for restocking will be exchanged or credited to your WPI account. Goods returned which were ordered by customers in error are subject to a 25% restocking charge. Equipment which was built as a special order cannot be returned. Repairs Contact our Customer Service Department for assistance in the repair of apparatus. Do not return goods until instructions have been received. Returned items must be securely packed to prevent further damage in transit. The Customer is responsible for paying shipping expenses, including adequate insurance on all items returned for repairs. Identification of the item(s) by model number, name, as well as complete description of the difficulties experienced should be written on the repair purchase order and on a tag attached to the item. * Electrodes, batteries and other consumable parts are warranted for 30 days only from the date on which the customer receives these items. World Precision Instruments 7

USA International Trade Center, 75 Sarasota Center Blvd., Sarasota FL 34240-9258 Tel: 94-37-003 Fax: 94-377-5428 E-mail: sales@wpiinc.com UK Hunting Gate, Hitchin, Hertfordshire SG4 0TJ Tel: 44 (0)462 424700 Fax: 44 (0)462 42470 E-mail: wpiuk@wpi-europe.com Germany Zossener Str. 55, 096 Berlin Tel: 030-688845 Fax: 030-688670 E-mail: wpide@wpi-europe.com China & Hong Kong WPI Shanghai Trading Co., Ltd. Rm 29a, No8 Dongfang Rd., Pudong District, Shanghai, 20020 PR China Tel: +86 2 6888 557 E-mail:chinasales@china.wpiinc.com Brazil Av. Conselheiro Nébias, 756 sala 26, Santos-CEP: 045-002, São Paulo Brazil Tel: (03) 406-29703 E-mail: info@brazil.wpiinc.com Internet www.wpiinc.com www.wpi-europe.com www.wpiinc.cn