Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Similar documents
Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

CP900EPFCLCD User s Manual K

PR1000ELCD / PR1500ELCD User s Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

General Precautions. Personnel Precautions

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation and Operation Manual Back-UPS BR1000-CH

Installation and Operation Manual Back-UPS BR800/1100CI-IN

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

3000VA 120/208/230VAC

MM-AVR UPS Series User s Manual

BRAVER UPS. (Uninterruptible Power System) User s Manual

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

Uninterruptible Power System

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User Manual 1KVA-5KVA INVERTER / CHARGER

User Manual 1.5KVA-3KVA INVERTER / CHARGER

User manual. Solar Hybrid 1-5KVA. Uninterruptible Power Supply / Charger

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

User Manual 5KVA/5KW INVERTER / CHARGER. Version: 1.3

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

Solar Hybrid Inverter SP Brilliant Series

MPPT Controller PVTS Series User Manual. User Manual. 800W-4000W Hybrid solar inverter. Version: 1.4

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

1KVA/ 2KVA/ 3KVA/ 4KVA/ 5KVA MS, LV MPPT INVERTER / CHARGER. User Manual. Version: 2.3

400 Watt Backup Power System Owner s Manual

Solar Hybrid Inverter SP Efecto Series

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

User Manual. Axpert King 3.2KW/5.2KW 48V MPPT SOLAR INVERTER. Version: 1.0

User Manual 1KVA-5KVA INVERTER / CHARGER

Informer Compact Series

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

User Manual 1KVA-5KVA (PF1) INVERTER / CHARGER. Version: 1.0

SCC-MPPT Solar Charge Controller

User Manual 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual LV 3KVA-24V INVERTER / CHARGER. Version: 1.1

Solar Hybrid Inverter SP Efecto Series

SCC-MPPT Solar Charge Controller

SCC-MPPT Solar Charge Controller

Sine Wave Solar UPS. Owner s Manual. Thank you for choosing the intelligent NON STOP Solar UPS with state of art technology.

User Manual SOLARMAX 1KVA/ 2KVA/ 3KVA INVERTER / CHARGER

User Manual 4KVA/ 5KVA INVERTER / CHARGER. With MPPT Controller

U P S. Uninterruptible Power System Unterbrechungsfreie Stromversorgung

USER MANUAL. PSC Plus3K Series Hybrid Inverter

1. Important Safety Warning

Solar Charge Controller

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Phoenix Inverter

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

User s Manual Legend SB825 UPS K

12VDC TO 230VAC INVERTERS

Solar Hybrid Inverter SP Brilliant Grid Series

User Manual 1KVA-5KVA INVERTER / CHARGER. Version: 2.1

UTILITY INPUT MAINS OUTLET

USER MANUAL ONLINE UPS

1. INTRODUCTION. Features:

Installation and user manual 5SC 500 5SC 750 5SC SC SC 500G 5SC 750G 5SC 1500G ENGLISH. Copyright 2013 EATON All rights reserved.

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Allen-Bradley. User Manual for 3000/5000 VA UPS. Tower/Rack-Mount 3U Uninterruptible Power Supply

FlinSlim Lite Solar Hybrid Inverter 1KVA-5KVA USER MANUAL. Version: 1.3

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

UPS USER MANUAL F-11 LINE INTERACTIVE UPS GENERAL PURPOSE UPS 650VA/1200VA/2200VA

Uninterruptible Power System

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

Pulsar EXtreme CLA 1500C

SOLAR INVERTER/CHARGER SOLAR INVERTER/CHARGER MPPT 2KVA- 3KVA. Appliances. Airconditioning Fridge. Washing machine

Installation and user manual. 5SC 500i 5SC 750i 5SC 1000i 5SC 1500i ENGLISH. Copyright 2013 EATON All rights reserved.

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

Pulsar EXtreme 2200C / 3200C

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Solar inverter with MPPT AX II - M series: 4 / 5 kva, AX II - P series: 3 kva. With integrated star point grounding* according to VDE AR-E 2510-

Low Frequency Inverter. User Manual

User Manual 3KW/5KW INVERTER / CHARGER. Version: 1.0

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

Solar Hybrid Inverter SP Initial Series

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

User Manual 1KW-5KW SOLAR INVERTER / CHARGER. Version: 1.2

9.1.4 Troubleshooting of Faults in LCD Screen

3 Uninterruptible Power Systems

Transcription:

Power Inverter Diamond Series CPD1200EILCD User s Manual

2

TABLE OF CONTENTS 1 IMPORTANT SAFETY INSTRUCTIONS..4 2 INSTALLATION....5 2-1 Unpacking...5 2-2 Product Overview & Outlook..5 2-3 Power Requirements of Your Equipment.....7 2-4 Hardware Installation Guide...7 3 DEFINITIONS FOR ILLUMINATED LCD INDICATORS...9 4 OPERATION & CONFIGURATION.11 Power On/Off.....11 Function Setup..........11 Audible Alarm.......11 Function Setup Guide......11 5 TROUBLESHOOTING..14 6 TECHNICAL SPECIFICATIONS..16 3

1 IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS) Before attempting to unpack, install, or operate the product, please read and follow all instructions carefully. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (Please see Technical Specifications section for acceptable temperature and humidity range.) CAUTION! The product must be installed in a protected environment away from heat-emitting appliances such as a radiator or heat register. The location should provide adequate air flow around the product for proper ventilation. CAUTION! To reduce the risk of injury, use cables come with the product. Use appropriate and certified external battery cables. CAUTION! To reduce risk of damage and injury, use batteries with good quality. CAUTION! Risk of electric shock. DO NOT remove the cover. No user serviceable parts inside. CAUTION! Provide adequate ventilation for the battery compartment. The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the compartment. CAUTION! A battery can present a risk of electrical shock and high short circuit current. When working on batteries, remove watches, rings, or other metal objects. Use tools with insulated handles. CAUTION! Hazardous live parts inside can be energized by the battery even when the AC input power is disconnected. CAUTION! To avoid electrical shock, turn off the unit and unplug it from the AC power source before installing equipment or servicing the battery. Servicing the battery can only be performed by trained personnel. DO NOT USE FOR MEDICAL OR LIFE SUPPORT EQUIPMENT! Do not use in any circumstance that would affect the operation and safety of life support equipment, medical applications, or patient care. DO NOT USE WITH OR NEAR AQUARIUMS! To reduce the risk of fire or electric shock, do not use with or near an aquarium. Condensation from the aquarium can cause the unit to short out. DO NOT USE THE PRODUCT ON ANY TRANSPORTATION! To reduce the risk of fire or electric shock, do not use the unit on any transportation such as airplanes or ships. The effect of shock or vibration caused during transit and the damp environment can cause the unit to short out. 4

2 INSTALLATION 2-1 Unpacking Inspect the product upon receipt. The box should contain the following: (a) This product; (b) User Manual; (c) Input Power Cord Power Inverter User Manual Input Power Cord 2-2 Product Overview & Outlook CyberPower Power Inverter ensures home/office users the always-on power supply with the exceptional power performance. Featuring the high-efficiency conversion design, the Power Inverter supplies long-lasting and reliable power to various appliances and provide longer backup for equipment. These units can be installed in either a horizontal or wall-mounted placement to make the most of your space. 5

CPD1200EILCD 1. Multifunction LCD Readout 2. Power On/off Switch 3. Function Buttons 4. AC Inlet 5. DC Input Cable(Red + ) 6. DC Input Cable(Black - ) 7. AC Outlet Application Diagram 6

2-3 Power Requirements of Your Equipment 1. Ensure that the equipment plugged into the AC outlet does not exceed the product s rated capacity (1200VA/900W for CPD1200EILCD). If rated unit capacities are exceeded, an overload condition may occur and cause the unit to shut down or the circuit breaker trip. 2. There are many factors that can affect the amount of power that your appliances will require. For optimal system performance keep the load below 80% of the unit s rated capacity. 2-4 Hardware Installation Guide Step 1 Connect the Battery For optimal battery life and reasonable recharging time, make sure the batteries capacity no less than 100Ah. Use batteries with same brand, type, and capacity. Connect DC input cables of this product to external batteries: Red + cable to the battery s Positive + polarity Black - cable to the battery s Negative - polarity Single Battery Connection Single battery voltage must be equal to DC voltage of the unit. Multiple Batteries Connection in Series Connect two batteries in series can double the voltage. Sum of voltages must be equal to DC voltage of the unit. 7

Multiple Batteries Connection in Parallel Connect multiple batteries in parallel can increase total battery capacity but still keep terminal voltage as single battery voltage. Step 2 Connect the Product to Utility Connect the product to a wall outlet. Charging the battery for at least 8 hours is recommended to ensure that the battery s maximum charge capacity is achieved. To recharge the battery and maintain optimal battery charge, simply leave the unit plugged into a wall outlet at all times. The battery can be charged whether the unit is turned on or off. DO NOT connect Neutral of the Power Distribution Box to (a) the OUTPUT Neutral of this product, or (b) the INPUT Neutral of connected equipment. Otherwise, reversed polarity will damage the product and connected equipment. Step 4 Connect the Load Connect the load to the unit s outlet. Make sure that the total loads of your appliances are below 80% of the unit s rated capacity. 8

3 DEFINITIONS FOR ILLUMINATED LCD INDICATORS LCD Display The left half of the LCD screen displays the energy flow direction and the status of the Power Inverter. The right half of the LCD screen displays the input, output, and battery information. Icon Description Normal Mode (Power On) The Power Inverter is turned on. Standby Mode (Power Off) The Power Inverter is off while the LCD display remains on. Utility Power Utility power source supplies AC power. Load Capacity The approximate load capacity of the unit s outlet. (in 25% increments) Battery Capacity The approximate battery capacity and charging status. (in 25% increments) Fault This icon appears if there is a problem with the unit. Overload This icon appears and an alarm sounds to indicate the outlet is overloaded. 9

Mute This icon appears whenever the unit is in silent mode. However, when there is a problem with the unit, the alarm will still beep even in silent mode. Setup Mode This icon appears whenever the unit is in Setup Mode. Input / Output / Battery Information It indicates input, output, and battery information. Operation Modes There are three types of modes regarding to the operation of the Power Inverter. The corresbonding LCD displays are as shown below. LCD Display Operation Mode Standby Mode In Standby Mode, the Power Inverter is off and the Utility power bypasses to output and in the meantime charges the battery. The LCD is on to show battery status. Line Mode The Power Inverter is turned on and AC input power is normal. It supplies power to the load (connected equipment). Battery Mode During a severe brownout or blackout, the Utility Power is absent and the Power Inverter switches to Battery Mode. The battery will supply power to the load (connected equipment). 10

4 OPERATION & CONFIGURATION Power On/Off Power On: Press the POWER button to turn on the unit. Power Off: Press the POWER button again to turn off the unit. Function Setup Press the SETUP button for 4 seconds to access the setup mode s 9 functions: Audible Alarm, Input Voltage Range, Utility Charging Current, Auto Restart Voltage, Low Battery Shutdown Voltage, LCD Auto Sleep, Cycling Display, Back to Default, and Return to Status Display. Short press the SELECT button to view the functions. When a function is selected, short press the SETUP button to access the function s options. Short press SELECT button to view the options. When the desired option is selected, short press SETUP button to confirm the setting. The unit will leave Setup Mode if there is no operation in 60 seconds. Audible Alarm Press SELECT button for 2 seconds to enable the audible alarm (beeps once) or disable (beeps twice) the audible alarm. The MUTE icon will appear on the LCD display when the audible alarm is disabled. Function Setup Guide Function Options Default Description Page 1 - Audible Alarm On Off On If Off is selected, the unit will mute alarms and the Mute icon will appear on the LCD display. Page 2 Input Voltage Range Hi (Wide): (90-280Vac) Lo (Narrow): (170-280Vac) Hi For connected equipments that are less sensitive to the fluctuation of voltage range, set the input voltage range wider and the output voltage will follow. For connected equipments that are sensitive to the fluctuation of voltage range, narrow the input voltage 11

range. Note: The transfer time will increase while the input voltage gets lower. If the connected equipment is sensitive to the transfer time, power interruption condition may occur. Page 3 Utility Charging Current 10/15/20A 20A With different battery capacity, adjust utility charging current to provide optimal recharging time. Recommended setting: 10A for 100Ah battery 15A for 150Ah battery 20A for 200Ah battery Page 4 Auto Restart Voltage Any/10.5/11.0/ /11.5/12.0/12.5/13. 0/FUL Any When the utility power comes back and starts to charge the battery, the Power Inverter will auto restart at the setting battery voltage. Page 5 Low Battery Shutdown Voltage 10.0/10.2/10.4 /10.6/10.8/11.0V 10.0V The Power Inverter will shut off if the battery voltage is decreasing to the setting value. Page 6 LCD Auto Sleep Off 0.5/1/2 Min 1 Min If Auto Sleep is selected, the LCD display will shut off after 0.5/1/2 minutes if no activity. 12

Page 7 Cycling Display Off 0.5/1 Min 0.5 Min If the buttons are not touched in 0.5/1 minute, the LCD will start cycling the Inverter information. Page 8 Back to Default Yes Select Yes to restore the factory default settings. Page 9 Return to Status Display - - Press the Setup button to go back to the status display. 13

5 TROUBLESHOOTING Problem Possible Cause Solution The product will not turn on. The unit is not connected to an The unit must be connected to a AC wall outlet. 220/230V outlet. The battery is worn out. Replace the batteries. Outlet does not provide power to connected equipment. Mechanical problem. Circuit breaker has tripped due to an overload. DC fuse is blown due to overload. Batteries are discharged. The product may require service. Contact CyberPower Systems. Turn the unit off and remove some of the connected equipment. Wait 10 seconds, reset the circuit breaker by depressing the button, and then turn the unit on. Servicing of the DC fuse should only be performed by trained personnel. For more information on DC fuse replacement, contact CyberPower Systems. Recharge the unit for at least 8 hours. Contact CyberPower Systems. The product is not turned on. Press the power button. There is no LCD display. Utility power is normal but the unit is in Battery Mode. The audible alarm beeps continuously. Batteries are discharged. The LCD is defective. AC input is missing. Input protector is tripped. The unit is in Fault Mode. Recharge the unit for at least 8 hours. Contact CyberPower Systems. Make sure the AC input is well-connected. Reset the input protector. Refer to Fault Code Table for further information. Contact CyberPower Systems. 14

Fault Code Table Fault Code Event Audible Alarm A64 Overload Rapid beeping every 1/2 second E07 Output Voltage High Constant tone E09 Output Short Constant tone E14 Overload Fault Constant tone E18 Fan Fail Constant tone E13 Over Charge Constant tone E25 Output Voltage Unbalance Constant tone 15

6 TECHNICAL SPECIFICATIONS Model Power Rating (VA/Watt) CPD1200EILCD 1200VA/900W Input Input Voltage Range Input Frequency Narrow Mode: 170-280Vac Wide Mode: 90-280Vac 50/60Hz (Auto-sensing) Output Output Voltage Output Frequency Outlet Type Transfer Time 230Vac 50/60Hz (1) UN < 8ms (Typical Narrow Mode) Battery Battery Voltage Charging Current 12V 10A / 15A / 20A (Adjustable) Environmental Operating Temperature ( C) 0 C to 40 C Operating Relative Humidity 0 to 90% (non-condensing) Physical Dimensions (WxHxD) (mm.) 266 x 92 x 273 Weight (kg.) 2.5 For more information, visit www.cyberpower.com All rights reserved. Reproduction without permission is prohibited. 16