TECH SPECS CONTACTS 2 HOUSE 2 STAGE 2 STAGE HOUSE 2 ELECTRICS 4 SOUND 5 UNION AFFILIATIONS 6 ANIMALS 6 SMOKING 6

Similar documents
HOMBURG THEATRE STAGE TECH INFO STAGE DIMENSIONS:

RIGGING SPECIFICATIONS:

James H. Whiting Auditorium (dba The Whiting)

BARBARA B. MANN PAH Tech Information Table of Contents

2209 S. Knoxville Russellville, AR (479)

Loading Dock: Two covered truck berths with a 100 long interior holding and storage area that enters onto stage left.

Facility Technical Package. Bert Church Live Theatre Address 1000 East Lake Blvd NE, Airdrie, AB Canada. Bert Church. LIVE Theatre

LOEB PLAYHOUSE TECHICAL SPECIFICATIONS PRE SHOW SHIPPING ADDRESS LARGE FREIGHT AND DAY OF SHOW SHIPPING ADDRESS TECHNICAL SPECIFICATIONS

P L A Y H O U S E Please confirm all critical measurements on site.

LYRIC THEATRE Please confirm all critical measurements on site.

ADDRESSES CONTACTS UNIONS

TECHNICAL INFORMATION SPARTANBURG MEMORIAL AUDITORIUM GENERAL INFORMATION

TECHNICAL INFORMATION SPARTANBURG MEMORIAL AUDITORIUM 385 North Church Street, Spartanburg, SC Office: , Fax:

Lydia Mendelssohn Technical Specifications

Travel Operation From SL or Guillotine. Permanent Raceway. DS Ceiling Shell -Do Not Move. MS Ceiling Shell - Do Not Move

300 West Water Street Jacksonville, Florida 32202

FOX TUCSON THEATRE AUDIO INVENTORY

Technical Information

MAIN STAGE - TECHNICAL INFORMATION

CONTACTS. Orpheum Theatre 910 Hennepin Avenue Minneapolis, MN 55403

Concert Hall Alsion. Address Alsion Concert Hall Address: Alsion 2. Capacity. Telephone:

Technical Director: Mike Hessler Ext 315

THÉÂTRE JEAN-DUCEPPE

POWERHOUSE THEATRE TECHNICAL SPECIFICATIONS /2013. Auditorium Seating. Page 1 of 5 STAGE CONFIGURATIONS

Stag Theatre & Stag Plaza Technical Specifications and General Constraints

Mead Theatre. Technical Summary

Technical Specifications Lyric Theatre Belfast Danske Bank Stage

Technical Information

Welcome to SYMPHONY HALL

TECHNICAL INFORMATION. Rabobank Arena Capacities. End stage - 9,000. End stage ,225. Center stage - 10,225. Half-house - 6,400.

Rickshaw Theatre Front of House Specs

RBC THEATRE TECHNICAL INFORMATION

Decidedly Jazz Danceworks Technical Specifications Updated: Jan 5, 2017

Technical Information Packet

Theatre Royal Windsor TECHNICAL SPECIFICANTION INFORMATION

HIRE AND TECHNICAL INFORMATION

GENERAL INFORMATION & TECHNICAL PACKAGE

Main House Technical Specifications Updated 16/10/2011. Stage

Technical Specifications Updated January 2018

TECHNICAL RECHARGES All recharges must be agreed with the Theatre Management before the first day of hire

Venue Specification. Concerts and Entertainments. Technical services supplied by: Harrogate International Centre Kings Road, Harrogate, HG1 5LA

BURDEKIN THEATRE BURDEKIN THEATRE. Technical Specifications

PRODUCTION SPECIFICATIONS

Technical Information

Technical Specifications

Technical Details And Contacts. (Last Updated 19 th September 2013)

Please contact Brisbane Powerhouse for further capacity and configuration break downs.

Wim Bagein T M

SALLE WILFRID-PELLETIER

ILLAWARRA PERFORMING ARTS CENTRE IMB THEATRE TECHNICAL SPECIFICATIONS

715 Locust St Evansville IN (812) (812) (fax#)

TECHNICAL SPECIFICATIONS MEDFORD, OREGON

All technical/logistical aspects of an event must be confirmed with the facility as part of the reservation process.

Technical Notes and Information. Lighting

COLORADO CONVENTION CENTER BELLCO THEATRE TECHNICAL SPECIFICATIONS REVISED AS OF 4/1/2016

ILLAWARRA PERFORMING ARTS CENTRE

TECHNICAL INFORMATION R.R. JONES THEATRE DAGGY HALL 1060 NE COLLEGE AVE. PULLMAN, WA 99164

THÉÂTRE CAPITOLE GENERAL INFORMATION ADDRESS MANAGEMENT TELEPHONE AND FAX NUMBERS TECHNICAL DATA. 972, rue Saint-Jean Québec (Québec) G1R 1R5 Canada

Wharton Center for Performing Arts Technical Information

TECHNICAL SPECIFICATIONS

TECHNICAL SPECIFICATIONS

MESA COMMUNITY COLLEGE MAIN HALL TECHNICAL INFORMATION PACKAGE

The Music Hall 28 Chestnut Street Portsmouth, New Hampshire. 1. Stage and Technical Notes for The Music Hall

GENERAL FACILITY INFORMATION - KANBAR HALL (REVISED AUGUST 2017)

Lighting Inventory. (2) 120/208V; 3 phase 400 Amp with lug connections, stage left at mezzanine No Shore Power available

Marine Hall Fleetwood Stage Side Elevation 2003.

CESSNOCK PERFORMING ARTS CENTRE (CPAC) VENUE TECHNICAL SPECS DRAFT #9. Contents 1. Stage Plan (Not to scale) 2

Seating Configurations & Stage Dimensions

Royal Theatre Northampton TECHNICAL INFORMATION Updated: August 2017

Full House Configuration View from the Stage

Technical Information

CIVIC THEATRE TECHNICAL SERVICES INVENTORY CIVIC THEATRE - MAIN AUDITORIUM

NST Campus- Main House

Seating Configurations & Stage Dimensions

1532 Technical Specification

Technical Information

The Kings Theatre Trust Limited Albert Road, Southsea, Hampshire, PO5 2QJ Fax: (023)

CESSNOCK PERFORMING ARTS CENTRE (CPAC) VENUE TECHNICAL SPECS DRAFT #8. Contents 1. Stage Plan (Not to scale) 2

Updated September 2016

TECHNICAL SPECIFICATIONS

NORTH CHARLESTON COLISEUM

Theatre Royal Nelson Technical Specifications

TECHNICAL INFORMATION 2018

Event Center. Welcome to the Event Center at San Jose State University. This multi-million

Theatre Royal Nelson Technical Specifications

TECHNICAL RIDER UPDATE

UNION IATSE Local #14 Business Agent Jim Anziano (518) Musician Contractor Nat Fossner (518)

Technical Rider v2.0 mar 'Going to the farm'

The St. Augustine Amphitheatre 1340C A1A South, St. Augustine, Florida 32080

PRODUCTION MANUAL 2016

General Information & Tech Packet

ELECTRICAL POWER AND HVAC LOAD REQUIREMENTS FOR PRODUCTION LIGHTING AND PERFORMANCE EQUIPMENT

LES ROIS VAGABONDS «Concerto for two clowns» by Igor SELLEM and Julia Moa CAPREZ

PRODUCTION MANUAL Welcome to Big Top Sydney, Sydney's state-of-the-art, multi-purpose, entertainment venue.

Technical Specifications

The St. Augustine Amphitheatre 1340C A1A South, St. Augustine, Florida 32080

HEAR THE DIFFERENCE!

Union Bank & Trust Pavilion 16 Crawford Circle Portsmouth, Virginia (fax)

TECHNICAL SPECS. PORTSMOUTH PAVILION 16 Crawford Circle Portsmouth, VA (Fax)

of our pianos. r) Any production

Transcription:

TECH SPECS CONTACTS 2 HOUSE 2 STAGE 2 STAGE HOUSE 2 ELECTRICS 4 SOUND 5 UNION AFFILIATIONS 6 ANIMALS 6 SMOKING 6 1 Front Street East, Toronto, Ontario, Canada, M5E 1B2 Tel:416.393.7469 Fax:416.393.7454

CONTACTS Howard Thornley (416) 393-7451 Manager, Stage & Facilities Services howard@hummingbirdcentre.com Roger Read (416) 393-7441 Property Master roger@hummingbirdcentre.com Richard Karwat (416) 393-7440 Head Electrician richard@hummingbirdcentre.com Rupert de Gruchy (416) 393-7468 Head Carpenter rupert@hummingbirdcentre.com Ross Tuskey (416) 393-7439 Head Sound Operator ross@hummingbirdcentre.com HOUSE SEATING CAPACITY: Orchestra 2,124 Mezzanine 256 Front Balcony 339 Middle Balcony 322 Rear Balcony 126 TOTAL 3,167 Pit Seating 56 TOTAL 3,223 Please note: If an event requires full seating, pit seating can be installed on request. Companies making such requests will incur costs for a seat installation call and removal call. STAGE Proscenium: 59-10 wide, 30 high Stage depth from curtain line to last available line set: 50 There is crossover space upstage of the last available line set. PLEASE SEE NOT TO SCALE GROUND PLAN ON SEPARATE PAGE. STAGE HOUSE FLY SYSTEM AND EQUIPMENT: House Curtain: Violet velour Operates as guillotine from stage left deck, motorized. RIGGING SYSTEM: Single purchase counter weight 40,000 lbs. available 74 sets at 6" o.c. with 6 lift lines per set 1200 lbs. capacity House Pipes: 60' long, 75' of travel from deck Five (5) hydraulic sets 1250 pounds capacity 130 spot wheels; 30,000' of hemp available PLEASE SEE HANGING PLOT ON SEPARATE PAGE 2

STAGE DRAPERIES: Teaser Black velour, 25 oz., 16 x 70 Portal Legs 2 pc. 16' x 32' Black Legs 4 pair, 25 oz. 20' x 36' 4 pair, 25 oz. 20' x 40' Black Borders 2-25 oz., 20' x 70' 5-25 oz., 16' x 70 Black Backing 2-25 oz., 35' x 40' SCRIMS 1 White 36' x 60' sharkstooth 1 Black 36' x 60' sharkstooth STAGE AND RELATED EQUIPMENT: Stage Floor: 3/8" Recycled plastic composite polyboard surface, sprung. No stage traps or stage elevators with the exception of the orchestra pit. Orchestra Pit: Adjustable to 20' below stage level by electric motor turnscrew. Apron overhangs US wall of pit 12'. Pit Equipment: Stands, chairs and lights. Risers: Risers Riser Tops 2 4' x 8' x 12" 11 5' x 8' 8 4' x 8' x 16" 11 4' x 8' 2 4' x 8' x 18" 5 4' x 8' x 36" 4 5' x 8' x 12" 4 5' x 8' x 24" 4 5' x 8' x 48" 29 TOTAL 22 TOTAL LOADING DOCKS: STAGE RIGHT DIRECTLY OFF SCOTT ST. TO STAGE One level loading. Load bars aresuggested as dock slopes down from street to doors. One street level. These docks are side by side, each with a door 13-6 high and 12-6 wide. There is freight elevator access off the loading dock for any goods being taken to the lower level. Freight elevator access must be maintained at all times for non-stage-related deliveries and pickups. STAGE LEFT DIRECTLY OFF THE ESPLANADE INTO THE STAGE DOOR LOBBY One - level loading. Doors are 6-8 high by 4-8 wide; dock opens into the stage door lobby. There is elevator access off the lobby to the second floor dressing rooms and wardrobe and lower level musicians lounge and pit. Access to stage left and the rehearsal hall by standard double doors. Forklift available in house. PARKING: There is no parking available at the Centre for any vehicles. There is a large, municipally owned parking lot on the Esplanade across from the Centre. This lot does not accommodate either buses or trucks. The Centre is located in the downtown core in a mixed commercial residential area just off the Gardiner Expressway. The streets on the west and north sides of the building are major traffic arteries into the city and to the expressways. Streets on the east and south sides, both of which access loading docks, are narrow with heavy vehicular and pedestrian traffic. City bus routes run along the north and east side streets adjacent to the Centre. Off site parking must be arranged for all trucks and buses once unloaded. 3

WARDROBE: Location: Access: Facilities: Stage left on 2nd floor. Elevator off stage door lobby. 2 washers, 2 dryers. WIG ROOM: The Centre does not have a wig room. DRESSING ROOMS: Dressing Rooms: 8 rooms Off stage left at stage level Chorus Rooms: 6 rooms Off stage left on 2nd floor Facilities: Mirrors, make-up lights, showers, toilets, sinks. Rolling costume racks available and built in racks in each dressing room. PLEASE SEE SEPARATE PAGE FOR LAYOUT. REHEARSAL HALL: Dimensions: 40' x 60', high ceiling. Location: Off stage left at stage level Facilities: Mirrors, wall mounted, on east wall. Piano available, tunings at client expense. Floor: Sprung floor with battleship linoleum surface. The Centre does not have a vinyl dance floor. The rehearsal hall is included with the theatre rental. STORAGE SPACE: None OTHER AVAILABLE SPACE: Two production offices off stage left, stage level with one fax/data line and two direct dial in lines installed. Additional telephones and fax lines must be ordered through the Centre at the client s expense. Musicians lounge in lower level off the pit. Male and female musicians locker rooms with toilets, sinks and showers adjacent to lounge. Small lock up room for musicians adjacent to the pit. Conductor s room with attached washroom (sink, toilet and shower) adjacent to musicians lounge in lower level. GREEN ROOM: There is a green room with a small kitchen attached off the stage door lobby on the main level. The green room must remain available for use by all backstage personnel. ELECTRICS ROAD SERVICE POWER: Panel Phase Amp Circuit Use Location Protection A to E 3 /panel 400 / panel Breaker Dimmers DSR pros. wall F 1 100 Breaker Sound DSL pros. wall G 3 100 Breaker Winches DSR pros. wall H 3 100 Breaker Extra DSR pros. wall I 3 100 Breaker Extra DSR pros. wall Recommended location for dimmer racks is stage right. FRONT OF HOUSE (box boom values are per side): Position Pipe Width Distance House FOH Transfer To Pros. Circuits Circuits 1st Balc. Rail 60 90 28 26 1st Cove 70 35 24 22 2nd Cove 70 48 24 24 Box Boom 1 2 9 6 Box Boom 2 7 9 6 Box Boom 3 11 9 6 All connectors are 20 amp, old style twistlock. Transfer circuits: ground 20 amp stage pin located on DSR proscenium wall. 4

EQUIPMENT - F.O.H. (box boom values are per side): Position Quantity Wattage Instrument Removable 1st Balc Rail 28 1,000 8 x 13 Lekos no 1st Cove 32 575 SL 15/320 no 2nd Cove 48 1,000 8 x 13 Lekos no Box Boom 1 6 575 SL 15/320 no Box Boom 2 9 575 SL 15/320 no Box Boom 3 9 575 SL 15/320 no PLEASE SEE SEPARATE SHEETS FOR LIGHTING PLOT. FOLLOWSPOTS: Followspots: Spot Booth: 4 Lycian 1290, 2000 watts; moveable 1 booth, maximum of 4 spots 145' throw to proscenium Booth Power: 4 three phase, 60 amp breakers The Centre does not provide the option of using non-house followspots in the booth without written agreement of the Centre. DMX: There is DMX capability depending on the location of road equipment. Please contact the house electrician to review show s requirements. LIGHTING BOARD: Strand 550I with Lightpallete operating system. Board is located in the rear balcony control room. Remote board at stage level Strand 520I. Capable of 2000 channels and 2000 attributes. Ethernet between the two consoles, full tracking back-up, production table SN100 and handheld remote. SOUND MAIN SYSTEM: Mix Position: Rear of orchestra Console: CADAC "F" 72 input Outboard: 1 T.C. Electronics M5000 Reverb, twin DSP engine 1 Yamaha SPX 900 effects processor 1 DBX-160 Limiter/Compressor 1 Drawmer M500 dynamics processor 1 Drawmer DL441 compressor There is a LARES Acoustic Enhancement System installed in the Auditorium. PLAYBACK/RECORDING: P.C. Based, digital audio workstation with various record and edit software programs. 1 TASCAM DA30 MK II DAT machine 1 TASCAM 122 MK III cassette deck 1 Denon CD player SPEAKER SYSTEM: Centre Cluster: Pros. L & R: 4 L-Acoustic ARC s 3 L-Acoustic ARC s 3 L-Acoustic SB 115 Sub woofers 2 Meyer R650 Sub woofers Front Fill: 4 L-Acoustic MTD 108 s Under Balcony: 8 L-Acoustic MTD 108 s MONITOR SYSTEM: Console: D.D.A. 24 x 8 Outboard: 3 Ashley G.Q. 231 Stereo Graphics 1 Ashley G.Q. 131 Graphic 5

Speakers: 2 Meyer U.M. 1 2 Meyer U.P.A. 4 L-Acoustic MTD 108 s Power: 4 Ashley F.E.T. 500 MICROPHONES: 6 Neumann KM 84 4 Neumann KM 84i 4 Neumann KM 140 7 Shoeps CMC5 4 Beyer M88 TG 8 A.K.G. 452 EB 4 Crown LM 301 3 SM 57 3 SM 58 4 Sennheiser KH 416 P48 4 Crown PCC 160 6 Sennheiser 521 MISCELLANEOUS: 1 Clear Com 4 channel base station 12 Clear Com Belt Pacs and Headsets (single channel) HEARING ASSISTANCE: Sennheiser infrared sound system for the hearing impaired. PROGRAM/PAGING: Comprehensive backstage paging and program sound system. UNION AFFILIATIONS IATSE Local 58 Stage Business Agent: William Hamilton 5 Lower Sherbourne St., Suite 201 Toronto M5A 2P3 Telephone 416-364-5565 Fax 416-364-5987 IATSE Local 822 Wardrobe Business Agent: Cheryl Batulis Telephone 905-726-8668 Wigs The Centre does not have an agreement with IATSE Local 800 Wigs. Arrangements for IATSE wig personnel must be made directly between the show and the Local. The Centre cannot provide payroll service for wig personnel. American Federation of Musicians, Local 149 (Toronto Musicians Association) ANIMALS Animals are not permitted in the Centre unless they are required by the show/event. SMOKING The Centre is a smoke free building. 6