DESCRIPTION The Bridge LED recessed offers a traditional yet modern design with the latest in solid-state lighting technology. High performing WaveStream optics allow for maximum energy savings and optimal illumination in a ultra-minimalistic shallow recessed fixture. Two WaveStream optic options are available; a fully uniform pattern and a square pattern that provides a unique translucent appearance without sacrificing performance. Additional shielding options are also available including rectangular perf, round perf, and nano-prism inlays. Available in 2x2, 2x4, 1x4 sizes along with several popular metric sizes, the Bridge is highly configurable with well-thought-out options and a number of architectural styles for application versatility. SPECIFICATION FEATURES Construction Shallow 3-7/8 deep housing is a 22 gauge steel reflector with injection molded high-reflectance polycarbonate end plates securely attached with integral snaps and screws for strength, rigidity and the elimination of gaps. WaveStream light engine with extruded aluminum heatsinks span across the bottom of the luminaire. Drivers can be accessed via plenum. Large access plate for supply connection. weight: 2. lbs. Optics Optical grade acrylic embedded with patented WaveStream Accu-Aim optics for optimal distribution, excellent uniformity, and high performance. Center light engine becomes virtually clear in the off-state. 23-5/8 [6mm] Shielding Perf pattern and nano-prismatic inlays are available as additional aesthetic options. Perf inlay available in round or rectangular pattern. Nano-prism inlay is a high light transmission material offering additional brightness mitigation. Finish housing and back reflector are high reflectance white using electrostatically applied polyester powder coat paint for durability and luminous uniformity. Electrical Long-life LED system coupled with electrical driver to deliver optimal performance. Projected life is 1, at 75 lumen output. LEDs are available in 3K, 35K or 4K with a typical CRI 85. Catalog # Project Comments Prepared by Standard drivers are -1 volt continuous dimming that work with any -1V control/dimmer. Or, specify Digital Addressable Lighting Interface (DALI) drivers; for use with Fifth Light controls. See ordering information for details. Mounting Universal flange design works with most lay-in ceiling types. Integral pry-out tabs secure luminaire to ceiling grid from above. offers tie-in locations for tiewire on all corners. Consult local code for appropriate tie-wire recommendations. See Technical Notes section for drywall frame kit and surface mount kit options. Compliance Components are UL recognized and luminaires are culus listed for 25 C ambient environments, damp location listed, and RoHS compliant. DesignLights Consortium Qualified and classified for DLC Standard, refer to www.designlights.org for details. Warranty Five-year warranty. Corelite Type Date BRIDGE - BRG Fully Uniform WaveStream LED 2 x 4 Recessed 3-7/8 Depth CERTIFICATION DATA culus - 1598 Damp Location Listed IC Rated LM79/LM8 Compliant ROHS Compliant DesignLights Consortium Qualified 47-3/8 [12m] 3-7/8 [99mm] 23-5/8 [6mm] ORDERING INFORMATION Sample Number: BRG-WS-3L35-LD2-UNV-24-T1-STD-SWPD1-EL14W-AR Series (1) Optics/Shielding 3-3/4 (2x4 Nominal [96mm] delivered lumens) Color Temperature LED Version Input Voltage BRG Bridge Recessed WS WaveStream Fully Uniform WD WaveStream with Round Perf Inlay WG WaveStream with Rectangular Perf Inlay WN WaveStream 11-5/8 with [296mm] Nano-Prism Perf Inlay 1 1 (3 Lms, 27W) 2 2 (4 Lms, 39W) 3 3 (5 Lms, 47W) 4 4 (6 Lms, 58W) 5 5 (7 Lms, 7W) L3 LED 3K L35 LED 35K L4 LED 4K LD2 LED 2. UNV Universal (12V-277V) 347 347V (2) (9) Size Ceiling Type Driver Type Integral Sensor (Optional) Emergency (Optional) Options 24 2 x 4 T1 1 T-Bar, Slot Grid, and 9/16 Tegular (3) T9 9/16 T-Bar (Flush) STD Standard -1V (1-1) HCD -1V (1-1) (6) STP Step Dimming (Bi-Level, 4) 5LT Fifth Light DALI (1-1) (4) 5LTHD Fifth Light DALI (1-1) SR Sensor Ready (5-1) (5) (7) (4) (8) SVPD1 Integrated upancy/daylight Sensor for Local Control (1) SWPD1 WaveLinx Wireless Integral Sensor (11) LWIPD1 Lumawatt Pro Wireless Integral Sensor (12) EL14W 14-watt 12V-277V Integral EM Battery Pack (13) GTD2 Bodine Generator Transfer Device (14) AR Air Return CP Chicago Plenum (15) W6 6 Whip Flex W12 12 Whip Flex See page 3 for technical notes 7/17/217 1 of 4
Bridge - BRG 2x4 PHOTOMETRICS 381 762 1143 1525 9 6 3 º (II) ----- 9º ( I ) -------------------------- FILE NAME: BRG-WS-3L35-LD2- LAMP: (LD2) LED 35K LUMENS: 5175 Lm EFFICACY: 11 Lm/W TEST NO.: P189656 SC: (II) 1.31, ( l ) 1.37 ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M 2 ) Angle º 45º 9º º-3º 1215 23.5 45º 2415 2528 2698 º-4º 235 39.3 55º 2435 2663 2932 º-6º 3835 74.1 65º 2434 2775 324 º-9º 5175 1 75º 2315 2742 2713 85º 1682 1594 1446 363 726 188 1451 9 6 3 º (II) ----- 9º ( I ) -------------------------- FILE NAME: BRG-WG-3L35-LD2- LAMP: (LD2) LED 35K LUMENS: 4669 Lm EFFICACY: 99 Lm/W TEST NO.: P189671 SC: (II) 1.24, ( l ) 1.32 ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M 2 ) Angle º 45º 9º º-3º 1129 24.2 45º 215 223 2452 º-4º 1863 39.9 55º 1915 2368 2731 º-6º 3446 73.8 65º 1789 2599 2921 º-9º 4669 1 75º 163 273 264 85º 1387 1446 1299 393 786 1179 1572 9 6 3 º (II) ----- 9º ( I ) -------------------------- FILE NAME: BRG-WN-3L35-LD2- LAMP: (LD2) LED 35K LUMENS: 4829 Lm EFFICACY: 12 Lm/W TEST NO.: P18971 SC: (II) 1.29, ( l ) 1.29 ZONAL LUMENS SUMMARY LUMINANCE DATA (CD/M 2 ) Angle º 45º 9º º-3º 1214 25.1 45º 2168 2324 251 º-4º 1994 41.3 55º 249 248 278 º-6º 3629 75.1 65º 1929 2556 2824 º-9º 4829 1 75º 1739 2554 2425 85º 1476 1416 129 Note: Round Perf (WD) photometric performance is similar to Rectangular Perf (WG). Reference IES-format photometry online for more detail. 181 E. Colfax Avenue Aurora, CO 811 P: 33-393-1522 7/17/217 2 of 4
Bridge - BRG 2x4 LUMEN MAINTENANCE ENERGY AND PERFORMANCE DATA Ambient Temperature INLAY OPTIONS TM-21 Lumen Maintenance (1, hours) Theoretical L7 (Hours) 25 C >75 125, Round Perf Inlay (WD) Rectangular Perf Inlay (WG) Nano-Prism Inlay (WN) 2x4 Bridge Outputs and Distributions (35K) Series BRG-WS BRG-WD BRG-WG BRG-WN Light Level Delivered Wattage Efficacy (LPW) 1 3145 27.1 116 2 4148 38.5 18 3 5175 47.2 11 4 616 58.5 15 5 7164 7.2 12 1 284 27.1 15 2 3746 38.5 97 3 467 47.2 99 4 5559 58.5 95 5 6469 7.2 92 1 2838 27.1 15 2 3743 38.5 97 3 4669 47.2 99 4 5559 58.5 95 5 6465 7.2 92 1 2935 27.1 18 2 3871 38.5 1 3 4829 47.2 12 4 5749 58.5 98 5 6686 7.2 95 Stock Catalog Number Product Description Stock Delivered Wattage BRG-WS-4L35-LD2-UNV-24-T1-STD 2x4 Bridge, 4 lm (LL2), 35K, -1V 4148 38.5 18 BRG-WS-4L4-LD2-UNV-24-T1-STD 2x4 Bridge, 4 lm (LL2), 4K, -1V 4235 38.5 11 BRG-WS-5L35-LD2-UNV-24-T1-STD 2x4 Bridge, 5 lm (LL3), 35K, -1V 5175 47.2 11 BRG-WS-5L4-LD2-UNV-24-T1-STD 2x4 Bridge, 5 lm (LL3), 4K, -1V 5283 47.2 112 Efficacy (LPW) TECHNICAL NOTES 1. Dimming wires come standard in all LED fixtures but can be capped in the field for standard switched operation. 2. Integral 347V electronic driver with STD -1V option only. Factory supplied remote transformer for all other driver/dimming options. 3. T1 ceiling type is compatible with Metalux DF Series Drywall Frame Kits and Metalux Universal Surface Mount Kits, ordered separately from Metalux. For 2x2 drywall frame kit, order part #DF-24-W. For 2x2 surface mount kit, order part #SK-24-WS. Refer to the surface mount kit specification sheet for more information. 4. Must be used in conjunction with a DALI control system. For a complete listing of Fifth Light Technology products and other solutions from Cooper Controls, visit systems. 5. 2x4: STP driver not available in s 1. 6. 2x4: Two HCD drivers required for s 4 and 5. 7. 2x4: Two STP drivers required for 5. 8. 2x4: Two 5LTHD drivers required for s 4 and 5. 9. 2x4: Two 347V -1V drivers required for 5. 1. SV sensor works only with -1V drivers and is factory prewired to the driver for stand-alone control. Order #ISHH-1 for Programming Remote and #ISHH-2 for Personal Control Remote. 11. SW sensor works only with STD and HCD -1V drivers. Designed for use with the WaveLinx Wireless Connected Lighting system. For complete WaveLinx wireless solutions, visit www.eaton.com/wavelinx. 12. LWI sensor requires the use of the SR driver. Must be used in conjunction with a LumaWatt Pro control system. For complete LumaWatt Pro wireless solutions, visit www.eaton.com/lumawattpro. 13. Integral emergency battery pack is 14W maximum, 9 minute output. A test switch/indicator button can be tested safely from the ground using a laser pointer, while the patented EZ Key prevents accidental discharge of the battery during construction. For approximate delivered lumens multiply the lumens per watt of the desired fixture by the wattage of the emergency battery pack (1 lm/w x 1414 lumens). Emergency battery pack not available with two driver configurations. 14. Used to transfer fixture to secondary power source for life-safety operation. When used with a dimming fixture, two devices are required to ensure control is disabled while operating under emergency power. Product height with transfer device is 5 (126mm). 15. Chicago plenum not available with GTD. 181 E. Colfax Avenue Aurora, CO 811 P: 33-393-1522 7/17/217 3 of 4
Raise/ Lower LO SET MIN Raise/ Lower stored light levels.. SVPD1 INTEGRATED SENSOR Bridge - BRG 2x4 The Bridge with Integrated Sensor technology provides automatic energy savings without sacrificing performance. Traditionally, these types of energy savings required coordination between the luminaire and a lighting control system. The Bridge delivers superior lighting with integrated PIR occupancy and daylighting controls. Capture the benefits of traditional lighting controls, without complicated coverage planning or special wiring. Ideal for new construction or retrofit, the Bridge delivers automatic ON to an energy saving light level, while ensuring lighting is turned OFF when the space is unoccupied. The integral daylight sensor reduces the need for special daylight zone planning. The luminaire will automatically adjust the light level based on reflected light beneath the sensor in a closed loop method. upied daylight light levels and unoccupied light levels can be adjusted using the integrated sensor programming remote (Catalog Number: ISHH-1). The integrated sensor personal remote (Catalog Number: ISHH-2) provides code compliant manual raise, lower, ON, OFF control. The Bridge with Integrated Sensor is easy to install with no special wiring and ensures energy savings out-of-the-box with default control settings. How it works: As the user enters the space controlled by the integral sensor, the lighting turns ON to the daylight level (default 5 lux). Lighting will remain at the daylight level until the space is unoccupied. This will start the occupancy timeout period (default 2 minutes). If the space remains unoccupied for half of the timeout period, the lighting will automatically reduce to the Energy Saver light level. This adjustable light level is typically half of the occupied daylight level. At the end of the timeout period the lighting will go to the unoccupied light level. This adjustable light level uses the OFF default setting. 1 Energy Savings Opportunities Timeout Value (ES) Energy Saver (DU) Level upied upied Target light level default: 5 lux at 8 ft. Coverage Coverage Top View C L 3.3m [1 ft.] m [ ft.] Major Motion m [ ft.] m [ ft.] Recommended Mounting Height 8 12 ft. Optional Remote Controls Time Out SCENE 5 MAX HI 1 75 ES 15 5 75 5 2 MIN MAX To Set Output Un 1. Raise, Lower or Press Min. 5, 75, Max. 2. To save press SET 3. Select or Un ES To Select Scenes Un Press the SCENE button. The lighting will adjust to Programming Remote ISHH-1 ISHH-1 Programming Remote Personal Remote ISHH-2 ISHH-2 Personal Control Remote 181 E. Colfax Avenue Aurora, CO 811 P: 33-393-1522 7/17/217 4 of 4
LL51911EN LL5191EN LL5191EN LL5191EN LL5191EN AUTO LUMAWATT PRO SYSTEM Bridge - BRG 2x4 LumaWatt Pro with Enlighted is an integrated system of luminaires, digital sensors, and application-based software for any size project. The strengths of LumaWatt Pro with Enlighted are based on the independent, secure operation of individual sensors in every lighting fixture, combined with wireless communication to the powerful Energy Manager. The system aggregates input from the project to provide visibility to entire aspects of environmental data from the project, putting the input into easy-to-read dashboards of analytic detail. The dashboards enable you to take additional action with the system to improve energy savings, master the use of the space, interact with heating, ventilation, and air-conditioning (HVAC) systems, and report on system modes to reduce maintenance. By collecting granular, real-time data from our state-of-theart integrated sensors to provide advanced, smart building solutions, you are in control. How it works: Luminaires are factory wired to sensors, which provide control based on digital occupancy and daylight dimming as independent, fault-proof, resilient networks of powerful end-points. Sensors communicate to each other, and gateways using easy wireless installation with secure set up. Gateways communicate using industry-standard wired technology to the Energy Manager, for powerful, familiar dashboards of useful information tailored for easy use on a connected computer. Energy Managers connect to cloud-based applications, maximizing the dense, data-rich sensing within the footprint of the luminaire for management of the building environment. 1 Energy Savings Opportunities Energy Manager Software Energy Dashboard Timeout Value (ES) Energy Saver (DU) Level upied upied Coverage, LWI Option Target light level and occupancy time are configurable Space Analysis Application AIRE Integration Application 2.7m [8.5 ft.] 3m [1 ft.] 3m [1 ft.] 1.5m [5 ft.] 1.5m 3m 3.3m [5 ft.] [1 ft.] [11 ft.] 1.65m [5.5 ft.] 1.65m 3.3m [5.5 ft.] [11 ft.] System Configurations LWP-EM-1 Connects up to1 LWP-GW-1 (1, Sensors Maximum) Local Computer or Building LAN Optional System Components Indoor Plug Load Controller LWP-POE8 Connects up to four LWP-GW-1 12V AC Optional System Components DRI-WS-3L35-UNV-22-T1-SR-LWI LWP-PC-1-2 Wall Station 12V AC LWP-GW-1 Connects up to 3 Sensors max. Outdoor CAT5 Cable (33' maximum), 2 per run Optional Components 12V AC GLEON-AE-4-LED-E1-T3-GM-LWR-LN LWP-WS-2-181 E. Colfax Avenue Aurora, CO 811 P: 33-393-1522 7/17/217 5 of 5