GRUNDFOS alldos product information. The digital diaphragm dosing pump for difficult liquids

Similar documents
Oxiperm 164 D for 30 to 2000 g/h

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 %

Oxiperm 164 C for 150 to 2500 g/h

DDA AR-PVC/V/C with access.

Oxiperm 164 and 166 GRUNDFOS PRODUCT GUIDE. Automated preparation of chlorine dioxide

GRUNDFOS ALLDOS DISINFECTION. ALLDOS DISINFECTION SYSTEMS with Chlorine Dioxide 1 GRUNDFOS ALLDOS DISINFECTION

GRUNDFOS DATA BOOKLET. DME and DMS DIGITAL DOSING

Diaphragm Metering Pumps

Product Information Stepper Motor-driven Diaphragm Dosing Pump MEMDOS SMART LP

GRUNDFOS PRODUCT GUIDE. DME and DMS. Digital Dosing

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ProMinent delta Solenoid Diaphragm Metering Pumps

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING

Lenntech GRUNDFOS ALLDOS DATA BOOKLET. DME and DMS DIGITAL DOSING

The Vario motor-driven pump series from ProMinent Adaptable to a wide range of applications VARIO METERING PUMP

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

GRUNDFOS DATA BOOKLET. Oxiperm OCD to 2000 g/h. Preparation of chlorine dioxide from diluted solutions

Excel AD Electromagnetic dosing pump

ProMinent g a m m a / L Solenoid Diaphragm Metering Pumps

ProMinent EXtronic Solenoid Diaphragm Metering Pumps

ProMinent Beta Solenoid Diaphragm Metering Pumps

EXCEL EXCEL XR DATA SHEET. Metering Pump. Manual, Enhanced, and Communications Models. Applications. Performance Specifications. Features and Benefits

Our vision is to be the first choice in the needs of our customers that we see as business partners and to serve without sacrificing quality.

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE DIGITAL DOSING. pumps and accessories

ELADOS EMP-KKS Diaphragm Piston Pump Type

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

ProMinent EXtronic Solenoid Diaphragm Metering Pumps

BATCHING UNITS - PUMPS SERIES ACL - AXL - DPZ INSTRUCTIONS MANUAL WARNING!

ProMinent Sigma/ 2 Motor Diaphragm Metering Pumps

ProMinent Pro M inent Sigma/ 3 Diaphragm Meter ing Pu mps. Diaphragm Rupture Warning System

GRUNDFOS PRODUCT GUIDE DME, DMS, DMM. Digital Dosing

ELADOS EMP III Diaphragm Pump type

Pro M i n e nt Sigma/ 2 Diaphragm Meter i ng Pu mps

ELADOS EMP III Diaphragm Pump type

ELADOS EMP III Diaphragm Pump type electronically controlled

Admiss. counterpressure. Admiss. pressure at pump inlet 115 S

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual

GRUNDFOS DATA BOOKLET. SMART Digital DDA, DDC, DDE. DIGITAL DOSING pumps and accessories

EXCEL EXCEL XR DATA SHEET. Metering Pump. Manual, Enhanced, and Communications Models. Applications. Performance Specifications. Features and Benefits

Admiss. counterpressure. stroke

ELADOS EMP II Diaphragm Pump Type V

CHEMICAL PUMP ACCESSORIES

GRUNDFOS DOSING ALL PRODUCT

Dosing pump series G A

Air Inlet/ Discharge Port

Product Information Motor-driven Diaphragm Dosing Pumps MEMDOS E/DX

DOSING UNIT WITH TIME CONTROL INSTRUCTIONS MANUAL WARNING!

Materials of Construction Head materials in PVDF, 316 SS, and PP Ball Valves - Ceramic, and 316 SS Diaphragm - PTFE faced Hypalon.

Kompact. Solenoid driven dosing pumps. Your Choice, Our Commitment

INSERTION flow sensor for continuous flow measurement

CALL GRIFFCO CHEMICAL PUMP ACCESSORIES

Maxima. Base mounted solenoid driven dosing pumps. Your Choice, Our Commitment

Tekna. Solenoid driven dosing pumps. Your Choice, Our Commitment

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Mechanical Diaphragm Metering Pump

ProMinent Hydro Hydraulic Diaphragm Metering Pumps

ProMinent. ProMinent D4a Metering Pumps with built-in proportional controllers

Electronic Metering Pump

An IDEX Water & Wastewater Business. pulsafeeder.com. Mechanical Diaphragm Metering Pump

An IDEX Water & Wastewater Business. pulsafeeder.com. Electronic Metering Pump

Positive displacement batch controller

PKX MA/A. Characteristics

M E T E R I N G P U M P S

SOLENOID DRIVEN DOSING PUMPS MX series

Instruction Manual. Dosing Pump type /150l/h

S300 L series positive displacement metering pump

An IDEX Water & Wastewater Business. pulsafeeder.com. PL Series Plunger Metering & Process Pumps

Diaphragm Type Control Version (S2Ca HM)

Inductive conductivity meter

Piston Metering Pump REKOS KR

Pacific Service & Supply Co., Inc.

Medo GA, GC, GE Product Data Sheet POE_CT0401. Dosing Pumps.

Ball valve C 200 PROP / C 200 DOS

motor driven metering pumps

The Metering Evolution

Metering Pumps DPL_GB_0909 The Metering Evolution

motor driven metering pumps

GRUNDFOS DATA BOOKLET DME. Digital dosing pumps

Accessories for ProMinent Beta, Gamma, Concept and Pneumados - Foot Valves. Valve body of PP, seals of EPDM.

Series PZ and PZi Pulse Metering Pumps

ProMinent gamma/l Metering Pumps

GRUNDFOS ALLDOS INSTRUCTIONS. DMB dosing pump. Installation and operating instructions (basic version)

ELADOS EMP IV E00 Diaphragm Pump type

PROTEUS Series Metering Pumps

GRUNDFOS DATA BOOKLET. Self-priming multistage pumps 50 Hz

GRUNDFOS INSTRUCTIONS. SMART Digital - DDC. Installation and operating instructions

GRUNDFOS DOSING SYSTEMS

solenoid driven diaphragm type metering pump

FLEX-PRO TM PERISTALTIC PUMPS

DSD Technology Reinventing metering pumps Dynamic Stiffness Diaphragm - High hydraulic performance

motor driven metering pumps

Continuous level measuring system NB 3000 Selection list. Overview

Series PZ Pulse Metering Pumps

DLX MA/AD. Characteristics

S OLENOID DIAPHRAGM DOSING PUMP GAMMA/ L FROM P ROM INENT. M ORE CONTROL, MORE DISPLAY, MORE APPLICATION VERSATILITY. NEW ROUTE.

1. General description CONTENTS. 1.1 Applications. The Buerkert 7800 dosing pump is a self-priming diaphragm

DLX MA/MB. Characteristics

Continuous level measuring system NB 3000 Selection list

Transcription:

GRUNDFOS alldos product information The digital diaphragm dosing pump for difficult liquids

Digital Dosing The Highlights Easy input and display of the dosing rate in l/h or gal/h with perfect calibration for optimum operating convenience and unparallelled levels of precision Smooth, nearly continuous dosing ensures a high process quality and optimal mixing of liquids For especially viscous liquids, there are 2 Slow Mode steps and special valve combinations Hotkey for easy query of the dosed quantity allowing optimal control of the consumption of chemicals Low energy costs thanks to the EC motor technology with imum efficiency Pump excess pressure control by digital input of the imum backpressure allowed before the pump stops High process reliability thanks to the double diaphragm system Radical reduction in variants and spare parts: 1 motor, 1 gearing and 2 dosing head sizes fit the complete pump series Adjustment range 1:800 Various possibilities for individual customer applications, e.g. contact or analogue signal control, batch or timer dosing Analogue and digital interfaces without extra charge DDI model 222-60 D display on the side Double diaphragm system with diaphragm control for protection of the pump in case of diaphragm leakage Standard: DDI model 222 with double diaphragm technology If there is a working diaphragm defect, the pump continues to dose with the robust protective diaphragm. Option: with diaphragm control For applications where the process must not be interrupted in the event of a diaphragm leakage, a differential pressure sensor is optionally available. In the event of a working diaphragm leakage, the sensor immediately sends out a signal, while the pump continues to dose with the protective diaphragm. DDI model 222-60 D with Flow Monitor for control of the dosing head pressure and the dosing flow DDI model 222-60 D with Profibus DP

Measurements Pump types Connections, cable and Euro plug included Strokes per minute: imal 180 in normal operation or imal 120 in Slow Mode 1 or 74 in Slow Mode 2 Q [l/h] Normal operation Slow Mode step 1 Slow Mode step 2 V stroke DDI model p [ml] [bar] [USg/h] [psi] [l/h] [bar] [USg/h] [psi] [l/h] [bar] [USg/h] [psi] (p = 3 bar) 60 10 15.87 145 40 10 10.58 145 24.7 10 6.53 145 6.63 222-60D 150 4 39.68 58 100 4 26.46 58 62 4 16.40 58 13.9 222-150D Measurements A4 A3 H2 H3 D1 175 230 C4 C1 61.5 Drilling scheme 105 123 B3 B4 7 9.7 A5 Ø7 (159) 16.5 172.5 207 All measurements in mm! Version for high-viscosity liquids (HV) DDI models A3 A4 B3 B4 C1 C4 D1 H2 H3 C1 C4 D1 H2 H3 222-60D 272 326 137 58 26 G 5/8 252 153 90 39 G 1 ¼ 246 143 222-150D 315 372 137 139 90 39 G 1 ¼ 265 179 90 39 G 1 ¼ 265 179

Technical data Technical data Input of the dosing capacity Connections Digital by regulation of the dosing stroke speed adjustment range: from 0.125% to 100% of the imum dosing capacity Material of connection DDI model 222-60D (DN 8) DDI model 222-150D (DN 20) PVC PVC hose 6/12 (pressure side) PE hose 9/12 (suction side) *) or PVC tube 10/12 or PE hose/2 (USA) PP PE hose 9/12 *) PP tube 12/16 PVDF PTFE hose 9/12 PVDF tube 12/16 Stainless steel Stainless steel tube R 1/4 1/4 NPT (USA) Accuracy Dosing flow < ± 1.5%, linearity < ± 1.5 % Noise level 65 ± 5 db (A), tested according to DIN 45635-01-KL3 Max. suction height 6 m Water Column for liquids with viscosity similar to water Max. viscosity (HV version) at operating temperature DDI model 222-60D 222-150D 2 bar on the suction side Normal operation 200 mpa s 500 mpa s Slow Mode 1 1000 mpa s 800 mpa s PVC hose 13/20 PVC tube 20/25 PVC hose 19/27 PVC tube 3/4 NPT (USA) PP tube 20/25 PVDF tube 20/25 Max. admission pressure Min. backpressure 1 bar (pressure difference with the suction side) Max. temperature. ambient and operating temperature + 40 C storage temperature - 10 C up to + 50 C Max. relative air humidity up to 92 %, no condensation Motor, motor voltage AC 110 240 V ±10%, 50/60 Hz, power consumption 50 W (including all sensors) Material of enclosure Pump and electronics, PPE/PS 20% glass-fiber reinforced Option: flame-proof enclosure Protection IP 65 Weight DDI model 222-60D PVC, PP, PVDF: 5 kg / stainless steel: 7 kg DDI model 222-150D PVC, PP, PVDF: 7.5 kg / stainless steel: 12 kg (*). backpressure 9 bars Dosing head and valve versions Dosing head Valve body Material of Gasket Valve seat Valve ball Special valves Springloaded pressure valve Valve sets for viscous liquids (**) DN 20 Stainless steel tube R 3/4 3/4 NPT (USA) Slow Mode 2 2600 mpa s 2000 mpa s Dosing head options Integrated control Diaphragm control Flow Monitor (***) Diaphragm control + Flow Monitor PVC PVC Viton Viton Glass PVC (*) PVC EPDM EPDM Stainl. steel PP PP Viton Viton Glass PP PP EPDM EPDM PTFE PVDF PVDF PTFE PTFE PTFE Stainl. steel Stainl. steel Viton Stainl. steel Stainl. steel Stainl. steel Stainl. steel PTFE Stainl. steel Stainl. steel (*) Valve version for caustic soda NaOH (**) suction side: valve with steel ball, pressure side: spring-loaded valve with steel ball 4

Options / Electronics Options: Profibus, display Please indicate when ordering the pump: Profibus: Display: Profibus DP-VO incl. GSD file and address decoder document on the side or on the back of the pump Display Electronic functions and electronic data Continuous operation: Start/Stop, function check, dosing head deaeration Memory function saves up to 65 000 pulses Two-step tank empty signal: Reed contact for empty signal/pre-alert Flow Monitor, as an option Diaphragm leakage control, as an option Stroke signal (pre-adjusted) or pre-alert (adjustable) Code protection against unauthorized access Calibrating function (on-site operating conditions) Pressure limitation Dosing quantity counter, with reset to 0 Tamper-proof service hours counter Remote On/Off Profibus DP interface, as an option Operating modes Input / Display Manual operation Input / Display of the dosing capacity in l/h or gal/h with calibrating function Contact signal control for smooth dosing Current signal control 0(4)-20 ma with manual weighting function Batch dosing (contact signal/manual) Input / Display of the dosing capacity in ml/contact DDI model V min (ml) V (ml) 222-60D 0.111 22.2 222-150D 0.278 55.5 Display of dosing capacity in l/h or gal/h (weighting function for the manual assignment of the volume flow in proportion to the current signal values (current input / current output) Input / Display of the dosing capacity in l/h or gal/h (per batch) Batch dosing with timer function > Input / Display of the dosing flow (1 ml to 9999 l) > Input / Display of the dosing capacity (l/h or gal/h) > Input starting time of first batch: t1 = 1 min. up to. 999 h > Input starting time of subsequent batches: t2 = 1 min. up to. 999 h Slow Mode (longer suction stroke) for dosing viscous liquids Two-step reduction of the suction speed and the imal dosing capacity down to 66% (Slow Mode 1) or 41% (Slow Mode 2) Inputs and outputs Inputs and outputs Pre-adjustment With software adjustable to Technical data Input Output Contact signal - - Load < 12 V, 5 ma, min. pulse lenght: 10 ms, min. pause time: 25 ms Current signal 0(4) - 20 ma - - Load < 22 Ohm Remote On/Off NO NC Load < 12 V, 5 ma Tank empty signal NO NC Load < 12 V, 5 ma Flow Monitor - - - Diaphragm leakage signal - - - Current signal 0(4) - 20 ma - - Load < 350 Ohm Error signal NO NC ohmic load < 50 V DC / 75 V AC, 0.5 A Stroke signal or empty pre-alert NO NC, empty pre-alert Contact time 200 ms/stroke ohmic load < 50 V DC / 75 V AC, 0.5 A 5

Accessories / Spare parts Accessories for electronics and Profibus Signal transmission cable including circular connector Please indicate the cable length: 2 or 5 m Straight plug Order Number Angled plug for input: control contact or 0/4-20 ma current input and remote On/Off, 4-wire cable 321-205 321-204 for output: empty pre-alert or individual stroke signal and error signal, 4-wire cable 321-206 321-286 for output: current signal, 5-wire cable 321-215 321-271 Accessories Profibus DP T-splitter with M 12 connection technology One needed for evey pump! 321-225 Terminating resistor M 12 Necessary for every pump connected at the last position in the bus system! Order Number 321-224 Accessories and fittings (see separate Data Booklet Accessories) 8 Flow scheme of a complete dosing installation 1 Dosing tank 502 2 Electric agitator 509 3 Extraction device 521 4 Suction pulsation damper 516 5 Dosing pump DDI 6 Pressure relief valve 525 7 Pressure loading valve 525 8 Pulsation damper 517 9 Calibration tube 10 Injection unit 522 11 Deaeration and drain valve 12 Check back valve 13 Filter 1 2 3 13 11 4 6 12 7 5 9 10 Spare parts sets Gaskets for dosing head, 1 dosing diaphragm Complete valves for 222-60D (plastic version) Inner valve parts for stainless steel version and for 222-150D (plastic version) Valve material for DN 8 : body / seat / gasket / ball without DLS Order number with DLS PVC / Viton / Viton / glass 553-1684-01 553-1684-10 PVC / EPDM / EPDM / stainl. steel 553-1684-02 553-1684-12 PP / Viton / Viton / glass 553-1686-01 553-1686-10 PP / EPDM / EPDM / PTFE 553-1686-02 553-1686-12 PVDF / PTFE / PTFE / PTFE 553-1687-05 553-1687-15 Stainl. steel / PTFE / PTFE / st. steel 553-1685-05 553-1685-15 for DN 20: valve seat / gasket / ball for PVC and PP: without DLS with DLS Viton / Viton / glass 553-1688-01 553-1688-10 EPDM / EPDM / st. steel 553-1688-02 553-1688-12 for PVDF: PTFE / PTFE / PTFE 553-1691-05 553-1691-15 for st. steel: PTFE / PTFE / st. steel 553-1689-05 553-1689-15 Console Description Wall console for DDI model 222, PP, with fastening material Order No. 539-029 6

222-60 D 222-150 D Diagrams Capacity diagram Viscosity diagram 222-150 D Normal mode 222-150 D Slow Mode 1 222-60 D Normal mode 222-60 D Slow Mode 1 222-150 D Slow Mode 2 222-60 D Slow Mode 2 Viscosity [cp or mpa/s] 7

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence 91834793 0307 15.820052 V3.0 EN Subject to change. Grundfos Alldos Dosing & Disinfection ALLDOS Eichler GmbH www.grundfosalldos.com