AGN 012 Environmental Rating Factors

Similar documents
AGN Alternator Ratings and Overload

AGN 041 Alternator Operating Speed

AGN Single Phase Loading for Re- Connectable 3-Phase Windings

AGN 065 Air Inlet Filters

AGN 021 Alternator Life Expectancy

HCM534F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCM274C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224G - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

UCI224D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

UCI274D - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534E/544E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCI 534C/544C - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

HCM534D - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

PI044D - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144G - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044H - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI044E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

PI144F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

UCDI274J - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

PI044G - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

HCM634K - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

PI144J - Winding 05 APPROVED DOCUMENT. Technical Data Sheet

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

HCM434E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM274E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCM224D - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 25. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 14. Technical Data Sheet APPROVED DOCUMENT

UCI274E - Winding 06 APPROVED DOCUMENT. Technical Data Sheet

PI734G - Winding 312. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 06. Technical Data Sheet APPROVED DOCUMENT

UCI224E - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI224F - Winding 311 Single Phase. Technical Data Sheet APPROVED DOCUMENT

UCI224C - Winding 06. Technical Data Sheet APPROVED DOCUMENT

PI736F - Winding 312. Technical Data Sheet

PM734E - Winding 28. Technical Data Sheet APPROVED DOCUMENT

HCI434E/444E - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI534F/544F - Winding 311 Single Phase APPROVED DOCUMENT. Technical Data Sheet

HCI634H - Winding 311 and 312. Technical Data Sheet

HCI434C/444C - Winding 17 APPROVED DOCUMENT. Technical Data Sheet

UCI274E - Winding 14 APPROVED DOCUMENT. Technical Data Sheet

PI144D - Winding 17. Technical Data Sheet APPROVED DOCUMENT

UCDI224E - Technical Data Sheet

EUROPEAN HIGH VOLTAGE FUSES

3.2. Current Limiting Fuses. Contents

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

S5L1D-G4 Wdg Technical Data Sheet

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

Customer presentation, PG Service, BU Motors and Generators ABB LEAP Stator Winding-Condition & Lifetime assessment

P734H - Technical Data Sheet

ALTERNATOR DE-EXCITATION WITH K1 AND K2 ON ANALOGUE

AGN 230 S0/S1 Alternators

AF series contactors (9 2650)

AGN Unbalanced Loads

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

tests Partial discharge level from day 1 10 pc Insulation 24 kv : impulse tested at 125 kv Insulation 36 kv : impulse tested at 170 kv, 200 kv indeed.

Transformer Installation, Operation, and Maintenance Manual

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

HCI634J - Winding 311 and 312 APPROVED DOCUMENT. Technical Data Sheet

AF series contactors (9 2650)

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

DC in the LV network: cable challenges. Antonios Tzimas Dimitris Antoniou Simon Rowland

INSTALLATION MANUAL. Instructions, precautions, suggestions for installing and servicing resin transformers in full compliance with safety rules

Generating Set considerations. AGN Motor Starting and Generating Set Considerations

User manual. Active neutralizing electrode JO96/1/L

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

RVS-AX Instruction Manual

Low Voltage Alternators - 4 pole LSA 44.3

HCI634V - Technical Data Sheet

Power Factor Correction

the ultimate alternator range

Welcome VA School Bus Technicians From

PhaseCap Premium PFC Capacitors Gas-impregnated n Dry type n Concentric winding n Wavy cut n Triple safety system

Preparing the Site. Information About the Site Requirements CHAPTER

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

Generating unit functional document submission form

Volume 2 Charts, Formulas, and Other Useful Information

Small wonder. Station service voltage transformers for small power requirements

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

UCM274C - Technical Data Sheet

UCM274H - Technical Data Sheet

Why Ni-Cd batteries are superior to VRLA batteries. Statements and facts

DATA SHEET. Three Phase Induction Motor - Squirrel Cage. Customer : Product code : : W22 NEMA Premium Efficiency Three-Phase

Remy HVH250 Application Manual Remy HVH250 Application Manual

HCI 534E/544E - Technical Data Sheet

Modifiable TITAN Horizontal Motors Accessories and Modifications

UCI224F - Technical Data Sheet

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

CHAPTER 1C PREPARING FOR INSTALLATION

Transcription:

Application Guidance Notes: Technical Information from Cummins Generator Technologies AGN 012 Environmental Rating Factors There are certain environmental conditions that must be considered when determining the correct alternator and alternator s output rating for a particular application. It is often necessary to adjust the published output rating to achieve the expected life and performance of an alternator. The following factors must be applied to the selected published output rating. AMBIENT TEMPERATURE Ambient Temperature can be defined as the temperature of the surrounding air at a particular location. The internationally accepted standard value for all industrial applications is 40ºC. All design work and most ratings for alternators are based on this figure. The measured ambient temperature should be that of the cooling air at the air inlet openings of the alternator, with consideration that this may be higher than the Generating Set s surrounding temperature, due to heat being generated within the Generating Set housing. Contact applications@cummins.com for rating multiplying factors for Marine applications. The thermal heat transfer characteristic of the cooling air passing through an alternator is reduced as that cooling air s temperature increases. High ambient temperature results in excessive operating temperature. To maintain the thermal rating of the machine, it is necessary to de-rate the kva rating by the appropriate rating multiplier from following simple table. The maximum permissible ambient temperature is 60ºC. Contact applications@cummins.com for guidance if the cooling air temperature is above 60ºC. For cooling air temperatures below 40ºC, International Standards allow the alternator s rating to be increased by an appropriate multiplying factor from the following simple table, but no further increase is allowed for temperatures below +10ºC. The table over-page is based on a ratings adjustment of 3% for every 5ºC from 40ºC and is appropriate for STAMFORD low voltage alternators in range, S0/S1 to S7. AGN 012 ISSUE B/1/8

Rating Multiplying Factor STAMFORD S0/S1 to S7 Alternators. Temperature in F 50 64 80 104 113 Temperature in C 10 18 27 40 45 122 50 0.94 131 55 0.91 140 60 0.88 Rating Multiplier 1.09 1.06 1.03 1.00 0.97 1.15 1.1 1.05 1 0.95 0.9 0.85 0.8 STAMFORD S0/S1 to S7 Alternators. Rating multiplying factor / maximum cooling air inlet temperature 0.75 0 10 20 30 40 50 60 Maximum Ambient Air Temperature C Class H The necessary ambient temperature rating multiplying factors for STAMFORD P80 (S8 and S9) alternators have been determined to take account of the wider operating voltage ranges and are different for the various Class temperature rise ratings. The multiplying factor are also appropriate for MV7 alternators. STAMFORD MV7, P80 (S8 and S9) Alternators. Throughout the alternator manufacturing business, there are often references made to low voltage (LV), medium voltage (MV) and high voltage (HV) outputs. Generally, LV refers to nominal voltages less than 690V, MV refers to nominal voltages between 1000V and 4400V and HV refers to nominal voltages between 4400V and 13800V. Rating multiplying factors for LV and MV alternators at Base Continuous Ratings for Insulation Classes; Class H, Class F, Class B and Class E. These multiplying factors are also to be used for Class Temperature Rise Ratings for Class H, Class F, Class B and Class E. AGN 012 ISSUE B/2/8

Rating Multiplying Factor Rating multiplying factors for HV alternators at Base Continuous Ratings for Insulation Classes; Class F, Class B and Class E. These multiplying factors are also to be used for Class Temperature Rise Ratings for Class F, Class B and Class E. Utilisation Class H Class F Class B Class E T / C V TC V TC V TC V TC 15 1.095 1.113 1.146 1.155 20 1.076 1.090 1.117 1.124 25 1.057 1.068 1.088 1.093 30 1.038 1.045 1.058 1.062 35 1.019 1.023 1.029 1.031 40 1.000 1.000 1.000 1.000 45 0.970 0.965 0.955 0.952 50 0.940 0.930 0.910 0.905 55 0.910 0.895 0.865 0.857 60 0.880 0.860 0.820 0.809 1.200 1.150 1.100 1.050 1.000 0.950 0.900 0.850 0.800 STAMFORD MV7 and P80 (S8 and S9) Alternators. Rating multiplying factor / maximum cooling air inlet temperature 0.750 0 10 20 30 40 50 60 Maximum Ambient Air Temperature C Class H Class F Class B AvK Alternators. If the alternator has been configured through the CAMOS tool, to the appropriate application specification, then all environmental rating factors that are applicable to that application for cooling air inlet temperature, will have already been applied. Therefore no further rating adjustment is necessary. AGN 012 ISSUE B/3/8

Rating Multiplying Factor Rating multiplying factors for AvK DSG (LV) alternators at Base Continuous Ratings for Insulation Classes; Class H, Class F and Class B. These multiplying factors are also to be used for Class Temperature Rise Ratings for Class H, Class F and Class B. Rating multiplying factors for AvK DIG (MV & HV) alternators at Base Continuous Ratings for Insulation Classes; Class F and Class B. These multiplying factors are also to be used for Class Temperature Rise Ratings for Class F and Class B. Utilisation Class H Class F Class B T / C V TC V TC V TC 15 1.090 1.110 1.130 20 1.072 1.088 1.104 25 1.054 1.066 1.078 30 1.036 1.044 1.052 35 1.018 1.022 1.026 40 1.000 1.000 1.000 45 0.968 0.963 0.955 50 0.935 0.925 0.910 55 0.903 0.888 0.865 60 0.870 0.850 0.820 1.150 1.100 1.050 1.000 0.950 0.900 0.850 0.800 AvK DIG & DSG Rating multiplying factor / maximum ambient air temperature 0.750 0 10 20 30 40 50 60 Maximum Ambient Air Temperature C Class H Class F Class B Further Information on Temperature Rise Changes with Increased Ambient Temperature. A mathematical relationship has been established and is shown below as a general guide for considering changes to cooling air temperatures as measured at the alternator s air inlet. The AGN 012 ISSUE B/4/8

following formula may be used if the alternator is to be relocated to a location with a different ambient temperature. Formula; Predicted temperature rise at a proposed new location where there is a higher ambient temperature. = Temperature rise measured under a known air inlet temperature X (160 + Ambient temp for new location) --------------------------------------------------------- ( 160 + Ambient temp during test ) Example; A Generating Set has been tested at its Class H temperature rise rating under a condition where the air inlet temperature is 26 C and the measured temperature rise is 112 C. The Generating Set is now to be relocated to an area where the ambient temperature is 40 C. Predicted Temperature rise at a proposed new location where there is a higher ambient temp = 112 C X (160 + 40) ---------------- (160 + 26) = 121 C ALTITUDE The density of air decreases at higher altitudes. Air at lower density decreases the heat transfer properties in an alternator, resulting in an increased temperature. To maintain the designed thermal rating of the machine, it is necessary to limit the alternator rating. Up to 1000 metres above sea level (3300ft) the change in air density is insufficient to radically alter the thermal transfer properties of air. Above 1000masl, the effectiveness of the lower density air in cooling the internals of the alternator reduces sufficiently. To prevent excessive temperature rise due to reduced cooling, the output rating must be derated. The internationally accepted de-ration factor is based on a 3% de-rate for every 500m over 1000masl, up to an altitude of 4000masl. For operating at altitudes above 4000masl (13123ft) contact applications@cummins.com for guidance. AGN 012 ISSUE B/5/8

Unlike ambient temperature, the converse is not permitted. No greater output is allowed from an alternator operating at an altitude below 1000masl. Altitude in Feet Altitude in metres De-rate multiplier 3,380 1000 1.00 4,921 1500 0.97 6,562 2000 0.94 8,202 2500 0.91 9,842 3000 0.88 11,487 3500 0.85 13,123 4000 0.82 14,763 4500 0.79 When a Generating Set is operated at high altitude, one of the first considerations applied by a Generating Set manufacturer is the potential loss of mechanical power. This is a real consideration and a true phenomenon, due to the lower density atmosphere, resulting in less engine Horsepower capability and so less mechanical kilowatt output. In most cases, the power reduction, due to reduced engine power is a greater factor than the deration required on the alternator. Regardless; the alternator rating must always be verified. It is important to understand; de-rates apply only to the alternator s Class temperature rise rating, not the complete Generating Set s rating. If the de-rated alternator kw capability remains equal to or greater than the Generating Set s de-rated kw capability, then there is no concern about operating at the Generating Set s capacity. If it is less, then the alternator will operate at a higher temperature rise and thus may require a change to a larger alternator. Note that this does not take into account, any other de-rate factors that need to be applied, such as for harmonic currents in non-linear loads. High Voltage Generators at High Altitude Despite the application of a de-rate factor, it is necessary to consider further, the use of HV Generating Sets at high altitudes, between 1000 and 4000masl. The reduced air density also means the dielectric strength of the air is reduced, which affects characteristics of the insulation materials in a winding insulation system. This effect can be particularly damaging on a high voltage alternator. Specifically on high voltage alternators operating at high altitude, there is the potential for a condition called Corona Discharge. There is sometimes an option to manufacture the alternator with a special insulation system, designed for high altitude. The insulation system would normally have thicker main wall insulation. The isolation/sensing transformer on an alternator may also be adversely affected at high altitude, so a special design isolation/sensing transformer may be required. Contact applications@cummins.com for further information. Corona Discharge. The reduced atmospheric pressure at high altitude has the effect of increasing the potential for Visible Corona, in essence reducing air insulation characteristics. This phenomenon is described by Paschen s Law. It is not important to understand the all the details of Paschen s Law, but rather to realise that within the range of altitudes applicable for Generating Sets, there is a change in Visible Corona field characteristics. As altitude AGN 012 ISSUE B/6/8

increases and so air density decreases, the potential for Visible Corona (purple glow) increases. Several factors influence the performance of insulation systems when operating at high altitudes. Invariably, however, they result in reduced insulation life and include: Environment conditions - humidity, ambient temperature, air cleanliness, etc. Application. Temperature rise. Manufacturing variance - inadequate space between phase coils, poor impregnation, loose fibres and/or poorly cut tape ends, poor insertion of the coils in the stator slots, etc. The Partial Discharge problem occurs in air-cooled machines rated at 6 kv or higher. Since discharges usually occur in air, ozone is created. Apart from its ability to destroy tissues, ozone, in the presence of nitrogen from the atmosphere, and water, creates nitric acid - HNO3, causing further erosion of insulation materials. The following general rules must be applied for alternators at altitudes above 1000masl: STAMFORD MV7 Alternators (1kV to 4.4 kv) Up to 3000masl, the thermal derate factor only is to be applied: 3% de-rate for every 500m over 1000masl. No alternative insulation system is offered as an option. At 3000masl and above, the MV7 is not offered. STAMFORD MV P80 (S8 and S9) Alternators (1kV to 4.4 kv) Up to 3000masl,the thermal de-rate factor only is to be applied: 3% de-rate for every 500m over 1000masl. At 3000masl and above, refer to applications@cummins.com for guidance, as a special insulation system design may be available. STAMFORD HV P80 (S8 and S9) Alternators (4.4 kv to 13.8kV) Up to 1500masl, the thermal de-rate factor only is to be applied: 3% de-rate for every 500m over 1000masl. At 1500masl to 3000masl elevation, only alternators with an output voltage of up to 11 kv are permitted, with the appropriate de-rate factor. Refer to applications@cummins.com as a special insulation system may be available.* At 3000masl to 4000masl elevation, only alternators with an output voltage of up to 6.6kV are permitted, with the appropriate de-rate factor. Refer to applications@cummins.com as a special insulation system may be available to increase the permitted output voltage to 7.2kV.* *These alternators will have special insulation needs and require special sensing transformers. This is not an industry standard, but derived from Paschen s Curve and the compactness of our design for satisfactory operation at normal elevations. The thermal rating of alternators with special insulation systems must be determined by design. Please refer to applications@cummins.com for thermal ratings. AvK DSG (LV) and DIG (MV & HV) Alternators. Up to 4000masl, a de-rate of 1% for every 100m above 1000masl is to be applied to the alternator s output rating. At 4000masl and above, refer to applications@cummins.com for guidance, as a special insulation system design may be available. AGN 012 ISSUE B/7/8

Environment. Alternators are designed to provide trouble free operation in clean dry conditions. The installation of the Generating Set is to be such that contamination by airborne dust, dirt, debris, water or other contaminants is prevented from reaching the alternator cooling air inlets. This is accomplished through proper design of the room or housing, possibly requiring air inlet filtration or alternator air filters. If optional alternator air filters are fitted, there is a minimum 5% thermal de-rate required to the output rating, in addition to the altitude-derived thermal de-rate factor. Application Guidance Notes are for information purposes only. Cummins Generator Technologies reserves the right to change the contents of Application Guidance Notes without notice and shall not be held responsible for any subsequent claims in relation to the content. AGN 012 ISSUE B/8/8