Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

Similar documents
Cast resin transformers

Product catalogue. Power Resistors. variable and fixed resistors wirewound resistor elements steel grid resistors. Power resistors

OLIVER ONLINE VOLTAGE REGULATION

AC/DC Arc Furnace and Ladle Furnace Transformers

ELECTRICAL TEST SOLUTIONS. Continuously variable control of voltage, current and power

Product presentation CPT tech Jason Evershed, ABB Transformer Components, May 21st Dry-type transformers Innovative Technology

Company Overview. Since 1975 in the sector, solid experience of design and production of dry type electric transformers and inductances

The construction features of EdM transformers

HARMONIC FILTER REACTOR

Pantograph disconnector type GW54, up to 550 kv Maximum reliability and minimal maintenance

YOUR KEY ENERGY EFFICIENCY PARTNER CAST RESIN DRY-TYPE TRANSFORMERS

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

3TM Vacuum Contactors

Motors Automation Energy Transmission & Distribution Coatings. UMBW UL489 and UL1077 Thermal-Magnetic MCB

Transforming Energy.. For Advanced Technology

Application Mini Contactors for Motors and Resistive Loads

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Components for EEx e Panels

Isolating transformer DS0107. Three-phase isolating transformers for the supply of three-phase loads in medical locations

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

CWM_N NEMA Rated Contactors

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Isolating transformer ES710

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

CAST RESIN TRANSFORMERS

AF series contactors (9 2650)

Limitor -G General Purpose Fuses

DRY TYPE TRANSFORMERS

NH DIN Dual Indication Fuse Links

Thermal-magnetic Miniature Circuit Breaker 4230-T...

EMPAC Metal enclosed capacitor bank for wind applications

Power & Distribution Transformers

Power Factor Correction

DISTRIBUTION TRANSFORMERS CATALOGUE

Power and Distribution Transformers

2 SLR Series Line Reactors... 50

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

CAST RESIN TRANSFORMERS CRT ED.: DEC.13 REV.00

INDUKTIVE SYSTEME. Green core Inductive Systems in action INDUKTIVE SYSTEME INDUKTIVE SYSTEME INDUKTIVE SYSTEME. topologies.

Guideline No.: E-07(201501) E-07 TRANSFORMERS. Issued date: October 20,2015. China Classification Society

Certified for best-in-class performance, reliability, and safety. Trihal sets a new standard for dry-type cast resin transformers

MODEL PC-252 Transformer Temperature Indicator Oil & Winding Temperature Indicator (with Micro Switches)

ROLF JANSSEN GMBH ELEKTROTECHNISCHE WERKE LOW VOLTAGE SWITCH PANEL

Mini contactors B6, BC6 with 3 pole

AF series contactors (9 2650)

Guideline No.: E-07(201610) E-07 TRANSFORMERS. Issued date: October 28,2016. China Classification Society

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

ZREW Transformers Perfection in Detail. a company of Rauscher & Stoecklin SERW ZREW Tesar

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Vacuum Cast Coil Dry Type Distribution Transformers. The reliability in your hands.

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

Accident, Maryland, USA

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Lenze. Drives with worm gearboxes 52.

EUROFUSE MULTIBLOC MULTIVERT D/D0-FUSE-SYSTEM BSL NH-FUSE-MATERIAL MULTIFIX 60 CYLINDRICAL FUSE-SYSTEM MINIATURE FUSE LINKS HIGH VOLTAGE FUSE LINKS

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

INESING GROUP. Power System Solution

Modulating control valves with magnetic actuators, PN 16

AIR CORE REACTORS. Phoenix Electric Corporation

Floor and fine adjustment switches

YOUR WISHES ARE OUR BENCHMARK. Transformers. Catalogue

MODULAR DEVICES. 21. Isolator Switches. Low Voltage (Bell) Transformers. Time Switches (electromechanical)

Thermal-magnetic Miniature Circuit Breaker 4230-T...

MULTIBLOC 3.ST8 Size 3, 630A, 690VAC, Design for Bottom Fitting, 3-,4-pole

Solenoid System FLANGE MOUNTING VERSION

HIGH POWER RECTIFIER SYSTEMS

CP Automatic capacitor bank

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

132/11 kv, 25 MVA MOBILE SUBSTATION

Motors and Gearboxes for Warehouse Logistics. Energy efficient Compact Sustainable

Customised drive solutions

Three Phase Capacitors KNK

3EP1 Surge Arrester. Metal-oxide surge arrester without series gaps for high-voltage systems up to U m. = 170 kv

SINAMICS GM150 IGCT version

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

MULTIBLOC 000.ST8 Size 000, 100A, 690VAC, Design for Bottom Fitting, Triple Pole

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Power Conversion Systems. SCHAEFER International. Switchmode Power Supplies, Chargers & Inverters. Thyristor-controlled Power Supplies & Chargers

Power Voltage Transformers for Air Insulated Substations

Horizontal center break disconnector Type SDF, up to 550 kv Maximum reliability and minimal maintenance

Modulating control valve PN16 with magnetic actuator

Suppression Technology Valve Suppressors - special function

Guideline No.: E-07(201712) E-07 TRANSFORMERS. Issued date: December 26, China Classification Society

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

Our Global Solutions CAPABILITIES

DYNACOMP. The top-class reactive power compensator

1.0 Installation Wiring

3RG4 BERO Inductive Proximity Switches

Actuators for air dampers and control valves of oil burners

Thermal Overcurrent Circuit Breaker 3120-F...

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Design specifications

MULTIBLOC 1.RST8 Size 1, 250A, 690VAC, Design for bus bar installation, Triple Pole

FUSES. Safety through quality

CAST RESIN TRANSFORMERS

Transcription:

Proficient. Innovative. Customer-orientated Transformers up to 8MVA AC/DC Reactors up to 3000A Power Transformers Cast Resin Transformers High-Current Transformers AC/DC Reactors Variable Transformers Voltage Stabilizers Toroidal Core Transformers

Quality knows no alternatives Ruhstrat GmbH has decades of experience in developing and manufacturing electrical winding products. We offer more than innovative technology, for we are a reliable partner and assist our customers by optimal solutions, customized to their needs. Many Branches Trust in Ruhstrat Transformers and Reactors. The key aspects of our activities are: In this context it is above all essential, that we are not only carrying through the development, design, and delivery and creating systems solutions, but furthermore we offer service performances reaching from the maintenance and technical support up to the supply with spare parts. Beside the entire standard programme, Ruhstrat s strong point is the design and manufacturing of plants and systems made to customers specifications. test engineering drive technology electrical engineering renewable engergy sources mains quality energy efficiency : Variable Transformers from 20 VA to 2 MVA varaible toroidal core transformers variable column transformers Voltage Stabilizers from 60 VA to 2 MVA magnetic voltage stabilizers transformer-type voltage stabilizers Power Transformers from 50 VA to 8 MVA low voltage dry-type transformers cast resin transformers railroad engineering AC/DC Reactors as line reactors, smoothing reactors, compensation reactors, harmonic circuit filter reactors, and motor reactors Toroidal Core Transformers up to 400 kva High-Current Transformers up to 30 ka machinery and plant engineering and construction shipbuilding

Power Transformers Power Transformers n single-phase and three-phase design n galvanically isolated winding or autowinding n according to IEC/EN 61558, VDE 0570 n power: up to 2.000 kva n voltage: up to 10.000 V n current: up to 30.000 A n frequencies: 16 2⅔/3 Hz, 50 Hz until 400 Hz n types of protection: from IP00 until IP54 n with rectifier as DC power supply n as energy-saving tranformer with a power efficiency > 99 %

Cast Resin Transformers AC/DC Reactors Cast Resin Transformers n according IEC/EN 60076-11, VDE 0532, DIN 42523 n single-phase and three-phase design n power: up to 8 MVA n voltage: up to 36 KV n types of protection: from IP00 to IP43 n winding material: aluminium or copper n environmental testing E2, climatic testing C2 and testing with regard to fire behaviour F1, according to IEC/EN 60076-11 n flash light test and short-circuit test according to IC/EN 60076-1-2-3. n application fields among others as: - power transformer - distribution transformer - transformer for 6-, 12-, 18- or 24-pulse rectifier operation - converter transformer as double-stack construction - step-up transformer - starting tansformer - test tansformer AC/DC Reactors according to IEC/EN 61558, VDE 0570 single-phase and three-phase with freely selectable inductivity up to 3.000 A frequencies: from 16 as - line reactor Hz up to 400 Hz - smoothing reactor - three-phase compensation reactor - three-phase harmonic circuit filter reactor - motor reactor - test reactor 2/ 3

Power Supplies Toroidal Core Transformers Power Supplies voltage and current supplies for industry and building management systems, individually made to customers specifications combined with industrial electronics, all switching and protection devices, electronical assembly groups, etc., which are required beside the transformer, are integrated Toroidal Core Transformers n according to IEC/EN 61558, VDE 0570 single-phase and three-phase design galvanically isolated winding or autowinding power: up to 400 kva as high-current transformer (actuator coil) up to 30.000 A

Variable Transformers Variable Transformers as variable toroidal tranformers as variable column transformers according to VDE 0552, IEC/EN 61558-2-14 single-phase and three-phase design construction for normal or heavy-duty operation according to VDE 0552 5 power: up to 2.000 kva voltage: from 0 to 10.000 V n current: up to 30.000 A frequencies: 16 2 3 Hz, 50 Hz to 400 Hz types of protection: from IP00 to IP54 as test engineering plant including electronical control for the application as - AC/DC voltage supply - AC/DC high-voltage supply - high-current test source - Test and equivalent current source for the test and development bay For test engineering plants Ruhstrat offers the entire range of test engineering by variable transformers, electronic controll systems (SIEMENS S7) included. For laboratory application, test fields, or mobile application Ruhstrat develops and manufactures custom-made voltage and current supply for the continuously variable adjustment from 0 to 10.000 V and currents up to 30.000 A.

Voltage Stabilizers Transformer-type Voltage Stabilizers according to IEC 60439-1, IEC/EN 61558, VDE 0552 single-phase and three-phase design power: up to 2.000 kva voltage: up to 10.000 V control range: ± 30% control speed: max. 60V/s types of protection: from IP00 to IP54 Certified according to KTA 1401 for application in nuclear power plants optionally as earthquake-proof version Magnetic Voltage Stabilizers according to EN 61558, VDE 0570 single-phase design power: up to 10 kva control speed from 40 to 60 ms types of protection: from IP00 to IP65

Industrial Furnaces Transformers Reactors Power Resistors