Failure to install product as instructed, use of hardware other than that which is provided with the product, or failure to comply with all instructions can result in product failure and/or personal injury and/or property damage. Illustration 1. Connection Guidelines: Illustration 1a. Method 1: Illustration 1b. Method 2: 12' Maximum 48" Minimum 20% of parent run length (Min.) 12' Maximum 48" Minimum WARNING IMPORTANT FOR ADEQUATE STABILITY of the HON Company s Initiate panel freestanding wall partitions, one of two methods of stabilization must be adhered to: Y A parent panel run must be a minimum of 48" and a maximum of 12 feet, and must have a minimum of two return panels totaling 20% of the length of parent run extended in opposing directions on each side of the parent run. DEFINITIONS: PARENT PANEL RUN - s (or a single panel) configured in a straight line intended to divide space. It is usually longer than the panels used to stabilize it. RETURN PANELS - s attached to a parent run for the purpose of stabilizing it. Return panels may also have the effect of dividing space. A parent panel run must be a minimum of 48" and a maximum of 12 feet, and must have at least two return panels each with a minimum length of 36". DEFINITIONS: PARENT PANEL RUN - s (or a single panel) configured in a straight line intended to divide space. It is usually longer than the panels used to stabilize it. RETURN PANELS - s attached to a parent run for the purpose of stabilizing it. Return panels may also have the effect of dividing space. INSTALLATION INSTRUCTIONS X X plus Y must total 72" or greater. SIDE 1 OF 5 (7/01)
Illustration 2. Overhead Storage Unit Guidelines: Illustration 2a. Guideline 1: Overhead storage unit Units must be suspended on panels of a corresponding width, or suspended across two panels with a combined width equal to the storage unit width. ~ s Illustration 2b. Guideline 2: Overhead storage unit WARNING Excessive or concentrated loads can cause a shelf or panel to collapse causing injury. Do not install more than 10 shelves onto a panel and do not put more than 300 lb. of evenly distributed load onto each shelf. More than two storage units can be suspended from a single panel only if return panels are positioned at each end of the storage units. ~ s SIDE 2 OF 5 (7/01)
Illustration 3. Inline Connection: Illustration 3a. Vertical Connector Installation: Vertical connector - insert into panel channels (3 per 42" panel, 4 per 55" panel, or 5 per 68" panel). Illustration 3b. Top Bracket Installation: T27 star socket head screw Top bracket Illustration 3c. Top Cap Installation: End Top - insert spring clips (attached to bottom of top ) into holes along Top and transition (shown installed) Illustration 3d. Base Rail End Cap Installation: Plastic fastener - insert through holes in end and base rail cover and press down on top button to lock into place. end panel run cover - use a utility knife to trim away light seal from end of base rail cover. SIDE 3 OF 5 (7/01)
Illustration 4. Corner, Tee, and Cross Connection: Illustration 4a. Universal Connector Installation: Universal connector Vertical connector - insert into each panel and universal connector channels (3 per 42" panel, 4 per 55" panel, or 5 per 68" panel). Illustration 4b. Universal Connector Bracket Installation: T27 star socket head screw Universal connector bracket Illustration 4c. Top Cap Installation: Transition Corner Top - insert spring clips (attached to bottom of top ) into holes along Detail 4a. Corner Cap: End Use a pair of pliers to remove knock-outs from side of facing panel connections. Bend knock-outs toward interior of corner Note: Refer to Illustration 3d for base rail end installation. panel run Illustration 4d. Corner Base Cap Installation: Illustration 4e. Extended Straight Base Cap Installation: cover Corner base Plastic fastener - insert through holes in corner base and base rail cover and press down on top button to lock into place. cover Plastic fastener - insert through holes in extended straight base and base rail cover and press down on top button to lock into place. Extended straight base SIDE 4 OF 5 (7/01)
Illustration 5. Variable Height Connection: Illustration 5a. Universal Connector Installation: Vertical connector - insert into each panel and universal connector channels (3 per 42" panel, 4 per 55" panel, or 5 per 68" panel). Vertical connector Universal connector - same height as tallest panel. Taller panel Shorter panel Illustration 5b. Universal Connector and Variable Height Bracket Installation: T27 star socket head screw Variable height bracket - insert into universal connector channel and position flat against top of shorter panel. T27 star socket head screw Universal connector bracket Taller panel Shorter panel Illustration 5c. Top Cap Installation: Corner Top - insert spring clips (attached to bottom of top ) into holes along Detail 5a. Corner Cap: End Top Use a pair of pliers to remove knock-out(s) from side(s) of facing taller panel(s). Note: Refer to Illustration 3d for base rail end installation. panel run SIDE 5 OF 5 (7/01)